SMOKE COMPARTMENTS / EXIT CALCULATIONS <br />Compartment <br />Compartment <br />Area <br />Occupancy <br />Type <br />Sq./ Ft. <br />Occupant <br />Number of <br />Occupants <br />2A <br />19,737 S.F. <br />Sleep <br />120 <br />164 <br />2B <br />18,677 S.F. <br />Sleep <br />120 <br />156 <br />2C <br />4,583 S.F. <br />Sleep <br />120 <br />38 <br />2D <br />18,410 S.F. <br />Sleep <br />120 <br />154 <br />2E <br />8,781 S.F. <br />Sleep <br />120 <br />( 73 <br />2F <br />7,022 S.F. <br />Sleep <br />120 <br />59 <br />2G <br />7,206 S.F. <br />Sleep <br />120 <br />60 <br />2H <br />18.646 S.F. <br />Sleep <br />120 <br />156 <br />21 <br />17,840 S.F. <br />Sleep <br />120 <br />149 <br />TOTAL SECOND FLOOR 120.902 S.F. <br />1009 <br />EXIT UNITS REQUIRED -1009 x .3 - 303' <br />EXIT UNITS PROVIDED - 534' <br />BUILDING COVE ANALYSIS <br />1. CODES - All work shalt conform to the following codes and ordinances: <br />- 2007 Florida Building Code, with the first and second 200 amendments <br />- 2007 Florida Existing Building Code, with 2009 amendments <br />- 2007 Florida Plumbing Code, with 2009 amendments <br />- 2007 Florida Fuel Gas Code, with 2009 amendments <br />- 2007 Florida Mechanical Code, with 2009 amendments <br />- 2007 Florida Fire Prevention Code <br />-2006 NFPA /0/ Llfe Safety Plan - Chapter 18119 <br />-2006 AIA Guidelines for Design and Construction <br />- Local Codes and Ordlnorces where applicable and flood <br />damage prevention ordinances <br />2. Use and Occupancy Classification: <br />As per FBC Chapter 3 and NFPA /01 Group 1.2 <br />Project square footage 275 square feet <br />J. Type of Construction: Type 1-8,Fully Sprinklered <br />As per FBC Section 602 and NFPA 101 Table 8.1 Type 1 t3,3,21 <br />4. Building Occupancy <br />Building Occupancy per FBC Table 1004.1.2 120 <br />and NFPA /0/ table 7.3.1.2 tin SF/Occupant!: <br />Area 0 Comportment 28 18.677 SF <br />Allowed Occupancy 156 <br />5. Exit Calculations <br />Permitted <br />Proposed <br />Max. Travel Distance: <br />300, <br />127'-10' <br />Max. Dead End Corridor: <br />30, <br />30, <br />Min. Corridor Width. <br />81'0' <br />8'-0' <br />Min. Clear Opening of Exit Doors: <br />32, <br />32, <br />Min. Stair Width: <br />81-0' <br />81-0' <br />6.. Interior Finish Requirements <br />As per FBC Table 803.5 <br />and NFPA /OI Table A 10.2.2 <br />Exits. Type A <br />Exit Access Corridors: Type A <br />Rooms & Enclosed Spaces: Type A <br />Project No. 10003.00 <br />Al 00 <br />© 2009 BH/PK Architects, Inc. <br />311612010 11:05:35 AM ...\cd\AI.O Llfe Sofety,dgn <br />