My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7050 Gall Blvd (116)
Zephyrhills
>
Building Department
>
Building Plans
>
7050 Gall Blvd (116)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 12:54:38 PM
Creation date
2/19/2025 11:44:30 AM
Metadata
Fields
Template:
Building Plans
Street #
7050
Location
Gall Blvd
Contractor
Sealander Contr
Building Plans - Permit #
10705
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
VOLUME <br />DAMPER <br />BEARING <br />o <br />U- o <br />J <br />w W <br />EA, RA FLOW f --► <br />SA FLOW <br />BRANCH DUCT <br />QUADRANT LOCKING LEVER <br />45 ° EXIT <br />PROVIDE CORNER PIECES <br />TO CLOSE OPENINGS <br />TRUNK DUCT <br />EXHAUST/ RETURN/ SUPPLYAIR <br />DUCT BRANCH DETAIL <br />NO SCALE <br />SQUARE THROAT KADIUS ELbUW t <br />ELBOW WITH <br />VANES <br />(CENTERLINE R = 32 = STD RADIUS) <br />NOTE: DUCTWORK HAS BEEN SHOWN USING SQUARE ELBOWS. RADIUS OR RADIUS <br />WITH VANES MAY BE USED AT CONTRACTOR'S OPTION. <br />NOTE: PROVIDE REQUIRED ELBOWS AND <br />TRANSITIONS TO CONNECT TO <br />BRANCHES. MINIMUM DUCT WIDTH SHALL <br />NOT BE LESS THAN 4". <br />SUPPLY DUCT INSULATED FLEXIBLE <br />_ METAL DUCT DIAMETER'D' <br />AS INDICATED ON <br />DRAWINGS <br />ti <br />TRANSITION T I <br />TO ROUND <br />FILTER FAN MODULE <br />FILTER <br />FAN HANGER. <br />SUSPEND <br />INDEPENDENTLY <br />grow"'manowNi <br />PROVIDE ADJUSTABLE <br />CLAMP TO PERMIT <br />REMOVAL OF DUCT FOR <br />FILTER MAINTENANCE <br />TYPICAL FLEXIBLE <br />METAL DUCT TO <br />FILTER FAN MODULE <br />2 <br />NO SCALE <br />MAXIMUM DIAMETER <br />OF TAP LESS THAN <br />OR EQUAL TO AIR WAY <br />SUPPLY TRUNK <br />RADIUS ELBOW <br />WITH VANES TAP DIAMETER <br />EXCEEDS AIR WAY <br />SUPPLY TRUNK <br />VOLUME DAMPERS <br />TYPICAL ELBOWS AND SPLITTER DETAIL <br />NO SCALE <br />TAP AT END OF <br />RECTANGULAR <br />DUCT RUN <br />SUPPLY TRUNK <br />45° ENTRY <br />RECTANGULAR TAP <br />EXHAUST DUCT STACK <br />1" ANNULAR AIR GAP <br />GUIDE WIRE SUPPORT <br />(3 POINTS) <br />WEATHERPROOF <br />FLEXIBLE CONNECTION <br />EXHAUST DUCT <br />DUCT CURB <br />EQUIPMENT SUPPORTS <br />ANCHORED TO ROOF DECK <br />SIMILAR TO AHU ANCHOR <br />SPIN -IN TAP <br />DAMPER <br />SOLID OR FLEXIBLE <br />DUCT AS APPLICABLE <br />RECTANGULAR TAP SIZE SHALL <br />BE THE EQUIVALENT DUCT SIZE <br />OF ROUND DUCT <br />TRANSITION TO ROUND <br />SOLID OR <br />FLEXIBLE <br />DUCT AS <br />DAMPER APPLICABLE <br />TRANSITION FITTING <br />DAMPER <br />DUCT LINING WHERE <br />APPLICABLE <br />NOTES: <br />1. DETAILS APPLY TO TAPS FOR INDIVIDUAL VARIABLE VOLUME BOXES (OF ALL TYPES), <br />SINGLE AIR TERMINAL DEVICES & OTHER BRANCH RUNS USING ROUND DUCT. <br />2. FOR TAPS SERVING INDIVIDUAL VARIABLE VOLUME BOXES (ALL TYPES), THE DAMPER <br />SHALL BE OMITTED. <br />3. FOR TAPS SERVING INDIVIDUAL AIR TERMINAL DEVICES LOCATED WHERE TAPS WILL <br />NOT BE ACCESSIBLE A DAMPER AT THE AIR TERMINAL SHALL BE SUBSTITUTED FOR <br />THE DAMPER AT THE TAP. <br />6 �NOUS <br />CT CTAP DETAILSALE <br />EXHAUST FAN SCHEDULE <br />MARK <br />CFM <br />FAN <br />MOTOR <br />CONTROL <br />TYPE <br />SERVICE <br />BASIS OF DESIGN <br />REMARKS <br />ESP <br />(IN. VC) <br />RPM <br />SIZE <br />HP <br />NO. <br />SPD <br />V <br />O <br />MANUFACTURER AND <br />MODEL NUMBER <br />EF-1 <br />1,100 <br />2.60 <br />2387 <br />3/4 <br />1 <br />480 <br />3 <br />BAS <br />UTILITY <br />EXHAUST <br />GREENHECK SWB-210-7 <br />SERVES CHEMO ROOM EXHUAST HOOD. <br />CONTINUOUS RUN, NO SHUTDOWN <br />AIR HANDLING UNIT SCHEDULE <br />MARK <br />EVAPORATOR FAN <br />COOLING <br />ELECTRIC HEATING <br />ELECTRICAL <br />BASIS OF DESIGN <br />REMARKS <br />SA <br />CFM <br />OA <br />CFM <br />ESP <br />(" M) <br />TOTAL <br />MBH <br />SENS <br />MBH <br />KW <br /># OF <br />_--_---_— <br />STAGES <br />LAT <br />----o.-----_ <br />(F) <br />FLA <br />MCA <br />V <br />0 <br />MANUFACTURER AND <br />MODEL NUMBER <br />RTU-1 <br />1,450 <br />600 <br />2.4 <br />97.3 <br />45.8 <br />--- <br />- <br />26.9 <br />480 <br />3 <br />TRANE MORGANIZER MODEL OHC120E <br />HIGH OA UNIT, HOT GAS BYPASS, <br />MERV 8PRE-FILTER <br />AHU-2 <br />2,500 <br />400 <br />-- <br />--- <br />-- <br />�- <br />-- <br />EXISTING TRANE AHU IN MECHANICAL ROOM <br />BALANCE TO PROJECT PARAMETERS <br />A <br />A <br />24„ <br />ROOF <br />SCREW EXHAUST STACK TO <br />CHANNEL APPROX. 5" O.C. <br />1". CHANNEL (2'-0" LONG) <br />SKIP WELD TO EXHAUST DUCT <br />A SECTION <br />NOTE: <br />PROVIDE WARNING SIGN ON FAN AS FOLLOWS: <br />CAUTION: BIO-HAZARD: <br />CHEMICAL HOOD ROOM EXHAUST. <br />TAKE PRECAUTIONS WHEN SERVICING THIS FAN. <br />EXTEND STACK <br />MIN. 7'-0" ABOVE <br />FINISHED ROOF <br />DISCHARGE DUCT, <br />FULL SIZE. <br />WEATHER HOOD <br />NOTE: PROVIDE EXHAUST FAN. <br />ANCHOR FOR HURRICANE <br />\ PROTECTION <br />VIBRATION ISOLATORS <br />MASON INDUSTRIES <br />TYPE SLF (TYPICAL) <br />3 CHEMO HOOD FAN MOUNTING DETAIL <br />NO SCALE <br />THROUGH -BOLT AHU <br />TO CURB AT WOOD <br />NAILER (TYPICAL) <br />SEE ARCHITECTURAL <br />ROOF CURB DETAIL <br />ROOF DECK <br />ANCHOR ROOF —CURB TO <br />DECK WITH THRU-BOLT <br />WITHIN 6 INCHES OF CORNER <br />THEN TWO FEET ON CENTER <br />(TYP. ALL SIDES) <br />ROOFTOP A/C UNIT <br />PREFAB CURB TO BE <br />BOLTED DIRECTLY TO <br />ROOF DECK <br />ROOFTOP A/C UNIT DETAIL <br />NO SCALE <br />DIFFUSER, REGISTER AND GRILLE SCHEDULE <br />NOTES: <br />1. UNIT SIZE IS BASED ON AIRFLOW (CFM) AS INDICATED IN THE SCHEDULE BELOW FOR EACH TYPE <br />DESIGNATION. <br />2. THE LISTING OF A PARTICULAR SIZE IN THE SCHEDULE DOES NOT MEAN THAT IT IS ACTUALLY USED <br />ON THIS PROJECT. <br />3. PROVIDE ONLY THOSE UNITS INDICATED BY TYPE AND CFM ON THE PLANS. <br />4. BRANCH DUCT SIZES TO THE DIFFUSERS, GRILLES AND REGISTERS SHALL CONFORM TO THIS SCHEDULE UNLESS NOTED <br />SCHEDULE UNLESS NOTED OTHERWISE ON THE PLANS. <br />5. AT THE CONTRACTORS' OPTION, BRANCH DUCTS MAY BE ROUND OR RECTANGULAR. <br />6. FOR ROUND NECK DIFFUSERS THE BRANCH DUCT SIZE SHALL BE EITHER THE NECK SIZE INDICATED OR <br />OR THE EQUIVALENT RECTANGULAR BRANCH SIZE INDICATED. <br />7. FOR SQUARE AND RECTANGULAR DIFFUSERS, GRILLES AND REGISTERS, THE BRANCH DUCT SHALL <br />BE SIZED AS INDICATED, WITH A TRANSITION TO THE ACTUAL NECK SIZE AT THE UNIT. HOWEVER, IF <br />SPACE IS AVAILABLE, THE FULL NECK SIZE MAY BE USED FOR THE ENTIRE BRANCH RUN. <br />8. ROUND BRANCH DUCTS MAY BE USED FOR SQUARE OR RECTANGULAR DIFFUSERS, GRILLES AND REGISTERS PROVIDING A <br />REGISTERS PROVIDING A SUITABLE TAPERED TRANSITION IS USED AND THE EQUIVALENT ROUND SIZE FOR <br />FOR THE LISTED BRANCH DUCT SIZE IS USED. <br />9. DUCT SIZES INDICATED ARE THE AIR SIDE OPENING DIMENSIONS. INCREASE SHEET METAL <br />DIMENSIONS AS REQUIRED FOR LINING OR OTHER FACTORS. <br />3 +S <br />W-11-11-1 <br />SERIES:FA <br />FIXED BLADE GRILLE, 3/4" SPACING FOR RETURN, EXHAUST OR TRANSFER <br />BASED ON TITUS 350 RL <br />NECK <br />RECTANGULAR <br />MINIMUM <br />MAXIMUM <br />SIZE <br />BRUNCH DUCT <br />REMARKS <br />AIRFLOW (CFM) <br />AIRFLOW (CFM) <br />(in x in) <br />(IN x IN) <br />0 <br />120 <br />22 X 10 <br />SEE PLAN <br />125 <br />260 <br />22 X 10 <br />SEE PLAN <br />265 <br />470 <br />22 X 10 <br />SEE PLAN <br />475 <br />530 <br />22 X 22 <br />SEE PLAN <br />535 <br />730 <br />22 X 22 <br />SEE PLAN <br />735 <br />810 <br />22 X 22 <br />SEE PLAN <br />815 <br />960 <br />22 X 22 <br />SEE PLAN <br />965 <br />1100 <br />22 X 22 <br />SEE PLAN <br />- <br />- qY1��� . <br />e <br />... �i <br />>�� rA <br />T ,. <br />.v'' �.-. <br />`. "' ���-•."�.f yw-o� . .J <br />iq. ,� Via., W <br />SERIES:FF <br />FILTER FAN MODULE <br />BASED ON AMERICAN AIR FILTER MODEL FM2-LE <br />RECTANGULAR <br />MINIMUM <br />MAXIMUM <br />WIDTH <br />LENGTH <br />BRANCH DUCT <br />REMARKS <br />AIRFLOW (CFM) <br />AIRFLOW (CFM) <br />(IN.) <br />(IN.) <br />(INAN) <br />0 <br />300 <br />24 <br />24 <br />10" ROUND <br />PROVIDE OPTIONAL DUCT CONNECTION <br />301 <br />750 <br />24 <br />48 <br />12" ROUND <br />PROVIDE OPTIONAL DUCT CONNECTION <br />ROOF DECK <br />Y8"O BOLT THRU CURB <br />3"x3"xY4' FRAME <br />PROVIDE 3"x3"x/° HEADER <br />BELOW ALL CURBS <br />Project No. 10003.00 <br />NOTES: <br />1. UNIT MINIMUM SEER =13.0 <br />2. UNIT DESIGN PARAMETERS — EDB = 81, EWB = 71, LDB = 49.3, LWB = 48.0, EVAP FAN HP = 3 HP, POWERED CONVENIENCE OUTLET, OUTSIDE AIR HOOD. <br />$DATE$ $TIME$ $F/LEA$ <br />M4.0 <br />0 2009 BH/PK Architects, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.