Laserfiche WebLink
I <br />4 3 2 1 <br />E <br />C <br />L� <br />N <br />CDI <br />I <br />co <br />0- <br />z <br />U_4 <br />€13 <br />I <br />A <br />UJ <br />N <br />00 <br />a <br />CD <br />ro <br />c� <br />LOCATE AIR CURTAIN <br />APPROX. 4" OFF EXTERIOR <br />WALL, CENTERED ON DRIVE <br />THRU DOOR. PROVIDE WITH <br />CFA DIVERTER BOX. <br />z1\ <br />FROM FACE OF PASS- <br />THRU WALL FRAMING <br />18'-8" <br />HOOD#2 <br />A-16"-915 A-16"-915-CJ#2 6 _ <br />�,. 9 <br />A-14"-825 �\ <br />18"x8" <br />UP �. �_._ A-14 -825 <br />i <br />'KITCHEN-- <br />18 A-14 -825 <br />CJ#3 <br />1 ^� <br />/ h f <br />8"x8" A-14"-825 <br />r, <br />MOUNT AC#1 MAIN TRUNK <br />LINE AS TIGHT AS <br />POSSIBLE TO STRUCTURE. <br />6 CJ#1 L <br />AAKI <br />MEAL DELIVERY CANOPY. <br />SEE ARCHITECTURAL. <br />U P ,� I <br />A-14"-510 <br />C-10"-355 <br />J� MECHANICAL FLOOR PLAN <br />K-10"-300 <br />DROP 18"x16" DUCT FROM PLENUM <br />TAP ABOVE BOTTOM OF TRUSS TO <br />nr-i r11A/ n/'1T-rf-%RA !'1r Tr11 rrIrl I ICIN l+ <br />SHEET NOTES <br />1. DUCT SIZES SERVING DIFFUSERS AND GRILLES ARE SAME SIZE AS <br />DIFFUSER OR GRILLE NECK UNLESS NOTED OTHERWISE. <br />2. FLEXIBLE DUCT NOT SHOWN FOR CLARITY. ALL TAKE -OFFS SHALL <br />INCLUDE FLEXIBLE DUCT. SEE DETAIL 1/M-401 FOR FLEXIBLE DUCT <br />INSTALLATION REQUIREMENTS. <br />3. FOR SUPPLY AND RETURN OPENINGS, CUT OPENING AROUND DUCT <br />DROPS 4" TO 8" MINIMUM (EXCEPT WHERE STRUCTURE PREVENTS <br />THIS). SEE ARCHITECTURAL AND STRUCTURAL DRAWINGS. <br />4. AT EACH PIECE OF ROOF EQUIPMENT, PROVIDE A PLASTIC <br />ENGRAVED LABEL WITH 1" HIGH WHITE LETTERS ON A BLACK <br />BACKGROUND. THE LABEL IS TO HAVE A SELF ADHESIVE BACKING. <br />5. UNLESS NOTED OTHERWISE, MC TO ADJUST ALL DIFFUSER AIR <br />PATTERN DEFLECTORS TO THROW HORIZONTALLY ALONG THE <br />CEILING. <br />6. SUPPORT ALL DUCT DROPS AT BASE OF DROP FROM STRUCTURE. <br />LEGEND <br />A-12-400 <br />TYPE - NECK SIZE - CFM <br />EF#1 <br />EXHAUST FAN #1 (TYP.) <br />SPIN -IN FITTING WITH MANUAL <br />BALANCING DAMPER, WITHOUT SCOOP <br />AC#1 <br />AIR CONDITIONING UNIT #1 (TYP.) <br />z <br />SPIN -IN HARDO FLEXIBLEO DIFFUSER <br />Z <br />RETURN/EXHAUST (TYP.) <br />SO <br />REMOTE TEMPERATURE SENSOR <br />® <br />SUPPLY DIFFUSER, SQ FACE (TYP.) <br />OH <br />HUMIDITY SENSOR <br />1 <br />PLAN NOTE REFERENCE <br />SD <br />SMOKE DETECTOR <br />MANUAL VOLUME DAMPER <br />12x18 <br />DUCT SIZE (reverse for elevation views) <br />DIRECTION OF THROW <br />ON DIFFUSER <br />1ST NUMBER - HORIZONTAL DIMENSION <br />2ND NUMBER - VERTICAL DIMENSION <br />CLOSED AIR PATTERN DEFLECTOR <br />SW <br />AIR DOOR SWITCH <br />GIH <br />GAS INFRARED HEATER (TYP.) <br />EC <br />ELECTRICAL CONTRACTOR <br />B/G <br />BELOW GRADE <br />MC <br />MECHANICAL CONTRACTOR <br />O <br />I THERMOSTAT <br />SEAL PENETRATIONS IN SMOKE DRAFT CURTAIN <br />AIR TIGHT. SEE ARCH PLANS FOR CONSTRUCTION. <br />... . <br />A-14"-450 <br />i <br />O KEY NOTES <br />13 A-14"450 <br />H.E.S. SYSTEM <br />MECHANICAL CONTRACTOR TO PROVIDE AND <br />INSTALL SUNCOAST H.E.S. SYSTEM FOR ALL HOODS. <br />SEE HOOD FAN/EQUIPMENT INTERLOCK WIRING <br />DIAGRAM ON M-501 FOR MORE INFORMATION. <br />WATER HEATER AND <br />FLUE BY PLUMBER. <br />A-14"-450 <br />7 <br />SERVICE <br />A-14"-585 <br />( �8 <br />0AD#2 <br />1 MOUNT REMOTE SENSOR ON WALL AT 5-0" AFF U.N.O. AND ROUTE WIRING BACK TO SUNCOAST TEMP CONTROL <br />PANEL. FOR SENSOR SERVING AC#1, COORDINATE EXACT LOCATION WITH KITCHEN EQUIPMENT. <br />2 MOUNT LENNOX HUMIDITY SENSOR ON WALL ABOVE SPACE TEMP SENSOR AND ROUTE WIRING TO UNIT ON <br />ROOF. <br />3 BRANCH TAKE -OFFS ARE NOT TO BE LOCATED CLOSER THAN 3'-0" FROM ANY OFFSET OR ELBOW INCLUDING THE <br />SUPPLY AIR DROP FROM CURB. <br />4 TRANSITION IN VERTICAL DROP FROM FULL SIZE OF CURB OPENING TO SIZE SHOWN. TRANSITION WITHIN CURB <br />WHERE REQUIRED TO AVOID STRUCTURE. WHERE THE DUCT IS SHOWN OFFSET HORIZONTALLY, PROVIDE <br />ELBOW WITH TURNING VANES. FOR DROPS WITH NO HORIZONTAL OFFSET, EXTEND DROP BELOW STRUCTURE <br />TO ACCOMMODATE START COLLARS. TERMINATE DROP A MINIMUM U-10" ABOVE CEILING (0'-4" ABOVE CEILING IF <br />REQUIRED TO ACCOMMODATE TAKE -OFF AND DROP IS NOT LOCATED DIRECTLY ABOVE A LIGHT). <br />5 TRANSITION IN VERTICAL DROP FROM FULL SIZE OF CURB OPENING TO SIZE SHOWN. SEE DETAIL 6/M-401 FOR <br />REQUIRED TRANSITION GEOMETRY. TRANSITION WITHIN CURB WHERE REQUIRED TO AVOID STRUCTURE. <br />WHERE THE DUCT IS SHOWN OFFSET HORIZONTALLY, PROVIDE ELBOW WITHOUT TURNING VANES. FOR DROPS <br />WITH NO HORIZONTAL OFFSET, EXTEND DROP BELOW STRUCTURE TO ACCOMMODATE START COLLARS. <br />TERMINATE DROP A MINIMUM 0'-10" ABOVE CEILING (0'-4" ABOVE CEILING IF REQUIRED TO ACCOMMODATE <br />TAKE -OFF AND DROP IS NOT LOCATED DIRECTLY ABOVE A LIGHT). <br />6 SEE ELEVATIONS ON M-301 FOR CJ FAN DUCTING REQUIREMENTS. <br />7 MECHANICAL CONTRACTOR TO ADJUST PATTERN DEFLECTORS TO THROW STRAIGHT DOWN. <br />8 AIR CURTAIN MOUNTED OVER DOOR HEADER AT T-2" AFF TO BOTTOM OF UNIT. PROVIDE BLOCKING IN WALL <br />BEHIND AIR CURTAIN. USE FACTORY PRE -PUNCHED MOUNTING HOLES ON BACK SIDE OF AIR CURTAIN ONLY. <br />ATTACH AIR CURTAIN TO WALL USING 3/8'' LAG BOLTS, LENGTH AS REQUIRED TO FULLY PENETRATE BLOCKING. <br />LOCATE MAGNETIC CONTACT TYPE MICROSWITCH IN DOOR FRAME ON STRIKE SIDE. <br />9 HALTON KBD DAMPER AT HOOD COLLAR BY MECHANICAL CONTRACTOR. SEE HOOD ELEVATIONS ON M-301 FOR <br />LOCATION. <br />10 YOUNG REGULATOR 12" MODEL 2010 ROUND ZONE DAMPER WITH MODEL T-312CE AUTOMATIC CHANGEOVER <br />THERMOSTAT. MOUNT T'STAT AT 4'-0" AFF. POWER OPEN/SPRING CLOSE. ADJUST MECHANICAL LIMIT FOR 50 <br />CFM MINIMUM AIRFLOW. CHICK-FIL-A HAS A NATIONAL ACCOUNT WITH TOM BARROW COMPANY FOR THE ZONE <br />DAMPER. THE MECHANICAL CONTRACTOR SHALL PURCHASE THE ZONE DAMPER DIRECTLY FROM TOM BARROW <br />COMPANY. CONTACT MR. SCOTT GEORGE AT 404-351-1010, FOR PRICING AND AVAILABILITY. ZONE DAMPERS NOT <br />PURCHASED THRU TOM BARROW COMPANY WILL NOT BE ACCEPTED. <br />11 PROVIDE 120V/24V 50 VA TRANSFORMER TO SERVE YOUNG REGULATOR ZONE DAMPER ACTUATOR AND <br />THERMOSTAT. POWER TRANSFORMER FROM 120V POWER CIRCUIT THAT REMAINS LIVE 24/7. PROVIDE ALL <br />NECESSARY WIRING AND COMPONENTS TO MAKE CONTROL AND POWER CONNECTIONS TO TRANSFORMER, <br />ZONE DAMPER, AND THERMOSTAT PER MANUFACTURER'S IOM. THERE IS NO INTERLOCKING OR MONITORING BY <br />WAY OF THE S.E.C. CFA-500 PANEL. SEE WIRING DIAGRAMS ON M-501. <br />12 PROVIDE 16" TO 14" TRANSITION ON COLLAR OF DIFFUSER. <br />13 RUSKIN MDRS25 MVD W/LOCKING QUADRANT HANDLE. <br />14 ROUTE DUCT WITHIN STRUCTURE. <br />15 10X10 EXHAUST DUCT DOWN. <br />16 MECHANICAL CONTRACTOR TO CLOSE THE AIR PATTERN DEFLECTORS ON SHADED SIDE. <br />17 PROVIDE 14" TO 12" TRANSITION ON COLLAR OF DIFFUSER. <br />18 CJ#3 MOUNTED INSIDE CABINETRY SERVING SCJ PLENUM, SEE DETAIL 2/M-301. <br />19 DAMPER HANDLES SHOULD BE INSTALLED SUCH THAT THE DAMPERS ROATATION AXIS IS PERPENDICULAR TO <br />THE FLOOR WITH THE HANDLE FULLY ACCESSIBLE UNDERNEATH THE DUCT IT CONTROLS. (TYPICAL OF ALL <br />DAMPERS AT THE SAME PLENUM.) <br />20 SUSPEND AIR CURTAIN FROM ROOF STRUCTURE USING THREADED ROD. FIELD WIRE REMOTE WALL SWITCH AND <br />INTERLOCK AIR CURTAIN WITH TORMAX DOOR. SEE WIRING DIAGRAM. MECHANICAL CONTRACTOR TO ADJUST <br />THE AIR PATTERN DEFLECTORS TO THROW TOWARDS THE OPENING. <br />E cQQO <br />0 <br />oC 0� �o <br />Chick-fil-A <br />5200 Buffington Road <br />Atlanta, Georgia <br />30349-2998 <br />IN <br />Kurzynske <br />& Associates <br />2900 Lebanon Pike, Ste 201 <br />Nashville, Tennessee 37214 <br />Telephone: (615) 255-5203 <br />Fax: (615) 255-5207 <br />D Email: mail@kurzynske.com <br />MARK T. KURZYNSKE <br />FLORIDA LICENSE # 53568 <br />�4tt46IIIE1,fi <br />� 4 Y U <i< <br />• .5 56 <br />• Y <br />� 1M • � +mod a� <br />0 : STATE OFa` Ri o <br />This item has been electronically signed <br />and sealed by Mark T Kurzynske. PE <br />on the date shown using a Digital <br />Signature Printed copies of this <br />document are not considered signed <br />and sealed and the signature must be <br />verified on any electronic copies. <br />Mark T <br />Kurzynske <br />Digitally signed by <br />C Mark T Kurzynske <br />Date: 2020.11.24 <br />15:10.48-06'00' <br />1 M <br />J� o� <br />LO <br />LL U) > M <br />Cn <br />LL <br />m J <br />>M <br />am o= <br />BUJ N �N <br />BUILDING TYPE / SIZE P13 LC ALL <br />RELEASE v2.20.02 <br />REVISION SCHEDULE <br />NO. DATE DESCRIPTION <br />1 11/25/2020 For Bid <br />�--' <br />CONSULTANT PROJECT# 20090.CC.S <br />A <br />PRINTED FOR FOR PERMIT <br />DATE 07/29/2020 <br />W <br />DRAWN BY BLM <br />aInformation <br />contained on this drawing and in all digital files <br />produced for above named project may not be reproduced in <br />any manner without express written or verbal consent from <br />authorized project representatives <br />O <br />SHEET <br />MECHANICAL FLOOR <br />U. <br />PLAN <br />SHEET NUMBER <br />M=201 <br />4 3 2 1 <br />