My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7490 Gall Blvd (2)
Zephyrhills
>
Building Department
>
Building Plans
>
7490 Gall Blvd (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 11:02:41 AM
Creation date
2/19/2025 11:46:42 AM
Metadata
Fields
Template:
Building Plans
Street #
7490
Location
Gall Blvd
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4 <br />3 <br />2 <br />1 <br />L# <br />A <br />F <br />B <br />N. <br />I <br />NT <br />4 <br />cy') <br />T_ <br />D <br />g um, <br />A <br />CD <br />'4 <br />CID <br />CD <br />LL <br />04 <br />r") <br />f <br />C7 <br />DAMPER <br />ACTUATOR 8 <br />CONTROL <br />BOARD EH <br />1 <br />1J_ <br />3 <br />4 <br />LED 6 <br />7 <br />- <br />M DAMPER MOTOR <br />24/120V 50VA <br />TRANSFORMER BY <br />XFMR MECHANICAL. <br />120 VAC TO <br />- - - TRANSFORM <br />R BY E.C. <br />D==E: DUCT TEMP <br />PROBE <br />FACTORY <br />INSTALLED. <br />I <br />I t <br />LEGEND <br />M.C. MECHANICAL CONTRACTOR <br />E.C. ELECTRICAL CONTRACTOR <br />- - - 18 AWG MIN WIRING BY M.C. <br />- — 18 AWG MIN LOW VOLTAGE <br />FACTORY WIRING <br />HIGH VOLTAGE BY E.C. <br />Q <br />YOUNG <br />REGULATOR <br />T-312CE <br />THERMOSTAT. <br />NOTES <br />1. SEE DWG M-201 FOR COMPONENT MODEL <br />NUMBERS AND ORDERING INFORMATION. <br />2. 120V POWER FOR TRANSFORMER TO BE NON - <br />SWITCHED AND LIVE 24 HOURS EACH DAY. <br />3. PROVIDE ALL NECESSARY WIRING AND <br />COMPONENTS TO MAKE CONTROL AND <br />POWER CONNECTIONS TO TRANSFORMER, <br />ZONE DAMPER, AND THERMOSTAT PER <br />MANUFACTURER'S IOM. <br />4. PROVIDE MYLAR LABEL AT ALL NEW <br />THERMOSTATS WITH 1/4" HIGH WHITE <br />LETTERING ON BLACK BACKGROUND, I.E. <br />"OFFICE THERMOSTAT". PLACE LABELS ON <br />WALL ADJACENT TO DEVICE. DO NOT APPLY <br />DIRECTLY ON DEVICE. <br />SEQUENCE OF OPERATION <br />1. WHEN THE SUPPLY AIR TEMPERATURE IS <br />LESS THAN 72F THE DAMPER WILL OPEN <br />FULLY ON A RISE IN SPACE TEMPERATURE <br />ABOVE THE SETPOINT. <br />2. WHEN THE SUPPLY AIR TEMPERATURE IS <br />GREATER THAN 71F THE DAMPER WILL OPEN <br />FULLY ON A FALL IN SPACE TEMPERATURE <br />BELOW THE SETPOINT. <br />VAV DAMPER AND TSTAT - MGRS OFFICE <br />NOT TO SCALE <br />LEGEND <br />S.E.C. SUNCOAST ENVIRONMENTAL CONTROLS <br />CFA-500 ENERGY MGT PANEL <br />M.C. MECHANICAL CONTRACTOR <br />- - — 18 AWG MIN UNSHIELDED LOW <br />VOLTAGE WIRING BY MC, U.N.O. <br />GENERALNOTES <br />1. THE SUNCOAST H.E.S. SYSTEM HAS BEEN <br />INTEGRATED INTO THE SUNCOAST <br />ENVIRONMENTAL CONTROLS CFA-500 <br />ENERGY MGT PANEL. <br />F - - - - - - - - - - - - - - - - - - - - - - - - - - - - -]-*_ SUNCOAST <br />ENVIRONMENTAL <br />CONTROLS CFA-500 <br />1 2 3 4 5 6 7 8 9 10 S.E.C. PANEL TB#8 ENERGY MGT <br />PANEL. <br />L------- - - - - - <br />J <br />DO NOT ROUTE ALONG OR NEAR HIGH VOLTAGE <br />WIRING. <br />NOTES: <br />1. MECHANICAL CONTRACTOR SHALL MAKE PLASTIC <br />LAMINATE OF THIS DETAIL AND INSTALL PERMANENTLY <br />ON INSIDE DOOR OF ROOFTOP UNIT CONTROL <br />COMPARTMENT. <br />2. SEE DETAILS THIS SHEET FOR SMOKE DETECTOR AND <br />ANNUNICIATOR WIRING. <br />3. SET ALL THERMOSTATS FOR AUTO CHANGEOVER. <br />4. PROVIDE PLASTIC ENGRAVED LABEL AT ALL NEW <br />SENSORS WITH 1/4" HIGH WHITE LETTERING ON BLACK <br />BACKGROUND, I.E. "AC#2 HUMIDITY SENSOR" OR "AC#2 <br />TEMP SENSOR". PLACE LABELS ON WALL ADJACENT <br />TO DEVICE, DO NOT APPLY DIRECTLY TO DEVICE. <br />KEYED NOTES: <br />1O LOW VOLTAGE WIRING TO RTU TO BE ROUTED TO <br />UNIT THRU FACTORY WIREWAY. <br />0 HUMIDITROL UNITS ONLY: WIRING TO HUMIDITY <br />SENSOR TO BE MADE WITH TWO SEPARATE RUNS <br />OF SHIELDED TWISTED PAIR. TERMINATE SHIELD <br />WIRES AT TBA, LEAVE OPEN AT SENSOR. <br />O3 NETWORK TSTAT REMOTE TEMP SENSOR PROVIDED <br />BY SUNCOAST AND INSTALLED BY MC. FIELD <br />CALIBRATE EACH SENSOR. <br />LEGEND <br />S.E.C. <br />SUNCOAST ENVIRONMENTAL CONTROLS <br />(SUPPLIER OF TEMP/FAN CONTROL PANEL) <br />LOCATED IN KITCHEN <br />OKEY <br />NOTE REFERENCE <br />MC <br />MECHANICAL CONTRACTOR <br />AC <br />SUNCOAST RELAY FACTORY INSTALLED AND <br />WIRED IN CFA-500 PANEL, ENERGIZED BY <br />PUTTING STORE SWITCH IN "STORE <br />OCCUPIED" POSITION. <br />AN <br />SUNCOAST RELAY FACTORY INSTALLED AND <br />WIRED IN CFA-500 PANEL, DENERGIZED <br />WHEN ANSUL FIRE SUPPRESSION SYSTEM IS <br />ACTIVATED, AS NOTED. <br />- - - <br />- 18 AWG MIN LOW VOLTAGE WIRING BY MC, <br />U.N.O. USE BELDEN OR SOUTHWIRE SINGLE <br />PAIR TWISTED WITH FOIL SHIELD AND DRAIN <br />WIRE FOR TEMPERATURE SENSORS (NOT <br />HUMIDITY SENSORS). <br />- <br />LOW VOLTAGE WIRING BY S.E.C. <br />LINE VOLTAGE BY ELECTRICIAN OR S.E.C. <br />AC#3 AVERAGING SENSORS <br />(WHERE SHOWN ON PLANS) <br />S.E.C. TERMINAL INDOOR TEMP INDOOR TEMP <br />INDOOR TEMP NOTES: <br />BOARD <br />SENSOR #1 SENSOR #2 <br />SENSOR #3 1. SEE DWG M-201 <br />FOR LOCATION AND <br />L!!2j- <br />- RS2 - - RS2 - - <br />RS2 ARRANGEMENT OF <br />SENSORS. <br />�+v <br />fl RS+V - - <br />RS+V1 <br />NoNETWORK TSTAT <br />RS1 - <br />- RS1 RS1 F- <br />RS1 REMOTE TEMP <br />J <br />SENSOR PROVIDED <br />SHIELDED <br />AVG AVG <br />AVG BY SUNCOAST AND <br />WIRING BY <br />INSTALLED BY MC. <br />MECHANICA <br />FIELD CALIBRATE <br />CONTRACTOR <br />EACH SENSOR, TYP. <br />RTU LVTB 10 <br />OCPI -------- - - - - -- <br />Y-2 - - - - - - - - - - - - - - - <br />SUNCOAST FACTORY <br />WIRING, TYPICAL. <br />S.E.C. <br />TERMINAL BOARD <br />R- <br />- - - - - - - - - - - - - <br />. <br />FDI- <br />W-2 <br />-------- - - - - -- <br />FW-" <br />— — — — — — — — — <br />C <br />2O LENNOX HUMIDITY <br />SENSOR <br />11 <br />L BELDEN VIN <br />— — — — — <br />RS' <br />fh <br />88761 <br />GND <br />RS+ <br />HUM <br />— BELDEN — — VOUT <br />88761 <br />RSA <br />DRAIN WIRE <br />DRAIN WIRE. DOUBLE WIRE OVER AT <br />TERMINAL CONNECTIONS BUT DO NOT TWIST. <br />ROOFTOP UNIT CONTROL WIRING - LENNOX <br />NOT TO SCALE <br />S.E.C. H.E.S. OPERATION <br />IN THE EVENT THAT ANY <br />COOKING EQUIPMENT ITEM <br />BENEATH ANY HOOD IS <br />STARTED WITHOUT THE <br />'STORE SWITCH' BEING IN THE <br />'OCCUPIED' POSITION, THE <br />H.E.S. CONTROLLER WILL <br />SENSE THE HEAT RISE WITHIN <br />THE HOOD CANOPY AND <br />ENERGIZE THE EXHAUST FANS. <br />W <br />AIR TEMP SENSOR PROVIDED BY S.E.C. AND INSTALLED IN BLACK IRON DUCT <br />00 <br />J <br />m <br />m <br />m <br />m <br />RISER ABOVE HOOD BY MECHANICAL CONTRACTOR. S.E.C. TO PROVIDE <br />W <br />NIX <br />M W <br />Ix <br />TEMPERATURE WELLS FOR INSTALLATION BY MC. SENSORS PROVIDED <br />a <br />a <br />a <br />a <br />a <br />WITH 10LF OF WIRING TO BE EXTENDED BY MC AS REQUIRED. SPLICES <br />02 <br />02 <br />O M <br />O M <br />O g <br />SHALL BE JOINED WITH CRIMP ON FITTINGS AND HEAT SHRINK JACKETS. <br />Oz W <br />O W <br />O W <br />O W <br />O W <br />SECURE WIRING TO DUCT OR STRUCTURE WITH RUBBER COATED CLAMPS. <br />PROTECT ALL WIRING PENETRATIONS IN WITH RUBBER GROMMETS. <br />HOOD FAN/EQUIPMENT INTERLOCK - 4 Hood (5 Collars) - CFA500 Integrated <br />1/4" = 1'-0" <br />N.O. <br />PROVIDE A PROFESSIONALLY LAMINATED COPY OF THESE DETAILS TO BE <br />INSTALLED INSIDE THE ROOFTOP UNIT CONTROL CABINENT. USE A SETON <br />CHART FRAME STYLE #68624, TELEPHONE NUMBER 800-243-6624, FOR <br />MOUNTING THE DETAIL. ATTACH THE FRAME TO THE INTERIOR OF THE <br />UNIT IN PLAIN AND EASY VIEW OF THE CONTROLS SECTION. CONTACT <br />ENGINEER OF RECORD FOR A REPRODUCIBLE COPY OF THE DETAIL. <br />SUNCOAST <br />FACTORY WIRED <br />RELAY SHOWN r <br />IN "STORE <br />UNOCCUPIED" <br />CONDITION, <br />TYPICAL. <br />AC <br />N.O. <br />RTU <br />THERMOSTAT <br />RS 1 AC <br />CLK2 - <br />RS+V LLU <br />N.C. <br />NETWORK <br />RS2 THERMOSTAT 0 <br />TEMP SENSOR <br />SHIELDED WIRING BY MC. BELDEN OR <br />SOUTHWIRE SINGLE PAIR TWISTED <br />WITH FOIL SHIELD AND DRAIN WIRE. <br />SUPPLY SIDE DETECTORS: <br />IF SUPPLY SIDE SMOKE DETECTORS ARE SHOWN ON DWG M-201, <br />AND CALLED FOR ON RTU SCHEDULE, THE CONTRACTOR IS TO <br />RELOCATE FACTORY INSTALLED SUPPLY SMOKE DETECTOR FROM <br />BLOWER SECTION TO DUCTWORK. SEE NOTES ON DWG M-201. <br />LEGEND <br />- - - - 18 AWG MIN WIRING BY <br />MECH CONTRACTOR <br />FACTORY ANNUNCIATOR <br />DETECTOR WIRING <br />FACTORY LENNOX <br />WIRING <br />PRODIGY <br />CONTROL <br />BOARD <br />LENNOX PRODIGY CONTROLLER SETTINGS: <br />1. FOR ALL RTU'S EXCEPT AT AC#1, CHANGE <br />PRODIGY-M3 BOARD CONTROL PARAMETER #65 <br />TO ZERO (#58 ON LCH UNITS). THIS WILL CAUSE <br />THE O.A. DAMPER TO OPEN ON "OCCUPIED" <br />START. AT AC#1 (LGH TYPE) LEAVE THE <br />SETTING AT THE DEFAULT VALUE SO THE O.A. <br />DAMPER WILL REMAIN CLOSED FOR THE FIRST <br />60 MINUTES AFTER "OCCUPIED" START. AT AC#1 <br />(LCH TYPE) CHANGE THE VALUE TO 5400 SO THE <br />O.A. DAMPER WILL REMAIN CLOSED FOR THE <br />FIRST 90 MINUTES AFTER "OCCUPIED" START. <br />SE PRODI Y-M3 B ARD 2. AT H`UMID`lRO`LRT�US, <br />CONTROL PARAMETER #105 FOR <br />DEHUMIDIFICATION OPERATION TO A VALUE OF <br />7. <br />3. AT HUMIDITROL RTU'S, SET PRODIGY-M3 BOARD <br />CONTROL PARAMETER #106 FOR <br />DEHUMIDIFICATION MODE SET POINT TO A <br />VALUE OF 60 (60% RH). <br />4. AT HUMIDITROL RTU'S, SET PRODIGY-M3 BOARD <br />CONTROL PARAMETER #107 FOR <br />DEHUMIDIFICATION MODE DEAD BAND TO A <br />VALUE OF 2 (2% RH). <br />5. AT M AV UNI 'SSE MS LOW PEED <br />SETTING TO THE SAME VALUE AS THE HIGH <br />SPEED SETTING AFTER TAB IS COMPLETE. <br />LENNOX FRESH AIR HEATING SETUP WHEN SPECIFIED: <br />1. INSTALL FRESH AIR TEMPERING KIT WIRING <br />HARNESS AS RECOMMENDED BY LENNOX. <br />2. LOCATE SUPPLY AIR TEMPERATURE SENSOR IN <br />SUPPLY DUCT DOWNSTREAM OF FIRST ELBOW. <br />SECURE WIRING TO DUCT OR STRUCTURE WITH <br />RUBBER COATED CLAMPS. DO NOT RUN WIRING <br />INSIDE DUCT WORK. PROTECT ALL WIRING <br />PENETRATIONS WITH RUBBER GROMMETS. <br />3. FOR PRODIGY 2.0: FIRST SET FRESH AIR HEATING <br />ENABLE TO "YES" THRU THE TAB/DAMPER MENU <br />(LEAVE FRESH AIR COOLING AS "NO"). NEXT, <br />CHANGE PRODIGY-M3 BOARD CONTROL <br />PARAMETER #156 TO A VALUE OF 66. THIS WILL <br />PREVENT THE SUPPLY AIR TEMPERATURE FROM <br />DROPPING BELOW 66F DEG DURING HEATING <br />MODE WHEN THERMOSTAT IS NOT ACTIVELY <br />CALLING FOR HEAT. <br />4. CHANGE PRODIGY-M3 BOARD CONTROL <br />PARAMETER #157 TO A VALUE OF 14. THIS WILL <br />MAKE THE DEADBAND VALUE EQUAL 14F. <br />5. CHANGE PRODIGY-M3 BOARD CONTROL <br />PARAMETER #158 TO A VALUE OF 300. THIS WILL <br />MAKE THE CYCLE TIME VALUE EQUAL 5 MINUTES. <br />FIELD INSTALLED WIRING: <br />WITHIN THE ROOFTOP UNIT, WIRING SHALL BE ROUTED BY <br />WAY OF FACTORY WIRE WAYS ONLY. WIRING ROUTED OVER <br />THE BLOWER HOUSING OR BY WAY OF OTHER ROUTES <br />DETRIMENTAL TO THE WIRING LIFE WILL NOT BE ACCEPTED. <br />' LENNOX FACTORY WIRING <br />LENNOX FACTORY INSTALLED DUCT DETECTOR <br />SYSTEM SENSOR M/N LD4120 <br />I I ' <br />® 1 POWER (24VAC) ALARM CONTACTS ARE <br />SHOWN IN STANDBY <br />® 2 POWER (COM) <br />-- - -- -- - - -- -- ICI 3 RESET <br />LABELING: <br />- - - - - - <br />® <br />4 <br />TEST <br />PROVIDE ENGRAVED LABEL WITH 1" HIGH <br />_ <br />_ _ _ _ <br />5 <br />ALARM SIGNAL <br />WHITE LETTERS ON BLACK BACKGROUND <br />IDENTIFYING UNIT SERVED. <br />6 <br />AUXILIARY POWER (-) <br />SUNCOAST CONTROLS ANNUNCIATOR <br />I <br />IF <br />A®d <br />7 <br />AUXILIARY POWER (+) <br />I <br />I <br />POWER l i <br />� — — <br />— � �- <br />�L � — <br />— — — J I <br />Rd <br />8 <br />ALARM INTIATION (COM) ALARM <br />N.O. <br />TROUBLE, <br />9 <br />ALARM INTIATION <br />l_ <br />st <br />sit <br />- <br />21 <br />TROUBLE CONTACT (N.C.) N.C. <br />TROUBLE <br />220 OHM RESISTOR <br />I <br />I <br />11 <br />TROUBLE CONTACT (COM) N.O. CONTACT <br />BY SUNCOAST. ----N <br />I AJ <br />I <br />10 <br />I <br />TROUBLE CONTACT (N.O.) <br />I I <br />® <br />12 <br />120V NEUTRAL <br />i I I <br />BUZZER O -�R\ ALARM I <br />I <br />13 <br />TROUBLE CONTACTS ARE <br />120VAC LINE SHOWN IN STANDBY STATE. <br />I I <br />® <br />15 <br />AUX RELAY (N.C.) N.C. <br />5 <br />AUX ALARM <br />(-- RESET I I <br />16 <br />AUX RELAY (COM)COM N O CONTACT A <br />- - <br />- ® <br />17 <br />AUX RELAY (N.O.) <br />J ( <br />® <br />I <br />18 <br />AUX RELAY (N.O.) <br />f -- TEST I <br />® <br />AUX ALARM <br />qN.C. <br />19 <br />AUX RELAY (COM)COMCONTACT B <br />-------� <br />® <br />20 <br />AUX RELAY (N.C.) <br />SMOKE DETECTOR AND ANNUNCIATOR WIRING <br />DIAGRAM <br />NOT TO SCALE <br />E <br />� OO 0 <br />4 <br />Chick-fil-A <br />5200 Buffington Road <br />Atlanta, Georgia <br />30349-2998 <br />Kurzynske <br />& Associates <br />2900 Lebanon Pike, Ste 201 <br />Nashville, Tennessee 37214 <br />Telephone: (615) 255-5203 <br />Fax: (615) 255-5207 <br />D Email: mail@kurzynske.com <br />MARK T. KURZYNSKE <br />FLORIDA LICENSE # 53568 <br />i C KUR <br />• 5 <br />. r <br />r <br />�0 :• STATE OF : <br />Onto <br />This item has been electronically signed <br />and sealed by Mark T. Kurzynske, PE <br />on the date shown using a Digital <br />Signature. Printed copies of this <br />document are not considered signed <br />and sealed and the signature must be <br />verified on any electronic copies. <br />Mark <br />Kurzynske <br />Digitally signed by <br />C Mark T Kurzynske <br />Date: 2020.11.24 <br />1. :13-06'00' <br />1 � <br />LL <br />Q r <br />LO <br />LLQ M <br />IIIIIIIIJ > M <br />LU 1 J J J <br />U. <br />Q co <br />J = <br />O = <br />UJ °- <br />B qq W <br />N tiN <br />FSR#04040 <br />BUILDING TYPE / SIZE: P13 LC ALL <br />RELEASE: v2.20.02 <br />REVISION SCHEDULE <br />NO. DATE DESCRIPTION <br />1 11/25/2020 For Bid <br />CONSULTANT PROJECT# 20090.CC.S <br />A <br />PRINTED FOR FOR PERMIT <br />DATE 07/29/2020 <br />W <br />DRAWN BY BLM <br />aInformation <br />contained on this drawing and in all digital files <br />produced for above named project may not be reproduced in <br />any manner without express written or verbal consent from <br />authorized project representatives. <br />SHEET <br />O <br />HVAC CONTROLS <br />LLL <br />SHEET NUMBER <br />M=501 <br />4 1 3 1 2 1 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.