Laserfiche WebLink
4 <br />3 <br />2 <br />1 <br />E <br />A <br />C« <br />B <br />VALVE TAG LEGEND <br />VALVE <br />VALVE POSITION <br />1) <br />MAIN WATER SHUT-OFF <br />NORMALLY OPEN <br />2O <br />MAIN DRAIN <br />NORMALLY CLOSED <br />3O <br />ACCESSORY SHUT-OFF <br />NORMALLY OPEN <br />® <br />WATER FILTER INLET <br />NORMALLY OPEN <br />0 <br />RECIRC PUMP ISOLATION VALVE <br />NORMALLY OPEN <br />© <br />WATER HEATER INLET <br />NORMALLY OPEN <br />7ORESTROOM <br />& KITCHEN COLD WATER <br />NORMALLY OPEN <br />® <br />POST HYDRANT COLD WATER <br />NORMALLY OPEN <br />O <br />GAS TO WATER HEATER <br />NORMALLY OPEN <br />10 <br />WATER HEATER OUTLET <br />NORMALLY OPEN <br />NOTE: HANDLE IN -LINE WITH PIPING = VALVE OPEN <br />LAMINATE VALVE TAG LEGEND <br />AND MOUNT PERMANENTLY <br />WHERE SHOWN ON WATER <br />HEATER DETAIL IN AN ALUMINUM <br />FRAME EQUAL TO SETON #68624. <br />VALVE TAG <br />2Q� VALVE TAG SYMBOL AS SHOWN ON DETAIL 6/P-303. PROVIDE 1-1/2" ROUND BRASS VALVE TAG <br />WITH 1/2" HIGH BLACK FILLED LETTERING. EACH TAG SHALL INDICATE VALVE NUMBER AND <br />WILL ALSO HAVE "PLBG" STAMPED ON THE TAG IN 1/4" HIGH BLACK FILLED LETTERING EQUAL <br />TO SETON #M4506. HANG WITH BRASS JACK CHAIN ON VALVE HANDLE. <br />VALVE TAGS AND LEGEND <br />NOT TO SCALE <br />WATER FILTRATION SYSTEM NOTES: <br />1. CHICK-FIL-A CONTRACTOR IS RESPONSIBLE FOR 3/4" CAPPED WATER LINE <br />FOR RO SYSTEM. SEE DETAIL #7 BELOW. <br />2. CHICK-FIL-A CONTRACTOR IS RESPONSIBLE FOR WATER FILTER <br />CONNECTIONS FROM PROTOTYPICAL T1 FILTRATION SYSTEM (#350). SEE <br />DETAIL #5 THIS SHEET. <br />3. CONTRACTOR SHALL REVIEW DESIGNOTE 2020-017 AND SYSTEMS TYPE <br />GUIDE DEVELOPED BY CFA & KINECTICO. <br />120 <br />*Plumbing in Red to be done by CFA Contractors <br />KINETICO INSTALLATION DRAWINGS <br />NOT TO SCALE <br />Please note: All dimensions are approx. - Not an <br />official drawing - Not for construction <br />TI <br />D <br />m <br />0 <br />I <br />0 <br />rD <br />rD <br />A <br />�v <br />0 <br />lk <br />2. <br />KITCHEN EQUIPMENT SCHEDULE <br />TAG <br />DESCRIPTION <br />FW <br />FW2 <br />CW <br />HW <br />WASTE <br />ROUGH -IN <br />305 <br />TEA BREWER <br />1/2" <br />X <br />X <br />X <br />X <br />P-24, SEE K-611 & 6/P-211 <br />308 <br />COFFEE MAKER <br />1/2" <br />X <br />X <br />X <br />X <br />P-24, SEE K-611 & 6/P-211 <br />318A <br />CARBONATOR BFP PANEL <br />3/4" <br />X <br />X <br />X <br />X <br />P-28, SEE K-611 <br />350 <br />WATER FILTER PANEL <br />(3) 3/4" <br />3/4" <br />3/4" <br />X <br />X <br />SEE DET 5/P-303 <br />360E <br />EMERGENCY EYEWASH STATION <br />X <br />X <br />1/2"* <br />1/211* <br />X <br />*1/2" TEPID WATER FROM P-42, SEE K-611 & 1/P-201 <br />363 <br />DISHWASHER <br />X <br />X <br />1/2" <br />X <br />INDIRECT TO P-13A <br />P-41, SEE K-611 & 1/P-201 <br />365 <br />POT SINK <br />X <br />X <br />(2) 1/2" <br />(2) 1/2" <br />INDIRECT <br />TWO #365F FAUCETS, P-9 SEE K-611 <br />367 <br />VEGETABLE PREP SINK <br />X <br />X <br />1/2" <br />1/2" <br />INDIRECT <br />#367F FAUCET, P-8 SEE K-611 <br />367FW <br />FILTERED WATER FAUCET <br />(2) 1/2" <br />X <br />X <br />X <br />X <br />P-30 48" AFF. <br />370 <br />MOP SINK <br />X <br />X <br />1/2" <br />1/2" <br />3" P-35 <br />P-7 SEE K-611 <br />380 <br />ICE MAKER <br />X <br />(3) 1/2" <br />X <br />X <br />INDIRECT <br />P-23 SEE K-611 & 3/P-201 <br />381 <br />ICE BIN (1 HEAD) <br />X <br />X <br />X <br />X <br />INDIRECT <br />SEE DET 3/P-201 <br />384 <br />ICE BIN (2 HEAD) <br />X <br />X <br />X <br />X <br />INDIRECT <br />SEE DET 3/P-201 <br />592 <br />RETHERMALIZER <br />X <br />X <br />1/2" <br />X <br />INDIRECT <br />SEE DET 3/P-302 <br />3/4" FILTERED WATER (FW) <br />TO WALL MOUNT FILTERED <br />WATER FAUCET, P-30. <br />3/4" FILTERED WATER (FW) <br />TO CARBONATORS. <br />1" CW WITH FULL <br />PORT BALL VALVE. <br />RAW SAMPLE TAP <br />3/4" CW CONNECTION <br />TO FILTER SYSTEM BY <br />PLUMBER. <br />BLOCKING WITHIN WALL <br />PROVIDED BY GENERAL <br />CONTRACTOR. COORDINATE <br />LOCATION WITH GC. <br />PLUMBING CONTRACTOR TO <br />EXTEND FLEXIBLE DRAIN LINE <br />FROM FILTER PANEL DRAIN TO <br />FUNNEL DRAIN P-26 BELOW. - <br />PIPING AT WATER FILTER <br />NOT TO SCALE <br />REFER TO KINETICO <br />SHOP DRAWINGS <br />SEE 1/P-201 FOR <br />CONTINUATION. TYPICAL. <br />3/4" FILTERED WATER (FW) TO <br />COFFEE AND TEA BREWERS. <br />3/4" FILTERED WATER, (FW2), <br />TO ICE MAKERS. <br />- - - - - - T- FROM KINETICO C <br />_ FILTRATION SYSTEM. <br />COORDINATE WITH <br />KITCHEN ELEVATIONS <br />FOR WATER FILTER <br />MOUNTING HEIGHT. <br />POINT OF PLUMBING <br />CONNECTION TO FILTER <br />SYSTEM. BY PLUMBER <br />OWNER SUPPLIED WATER FILTERS. <br />PLUMBER TO MOUNT ON WALL <br />AND MAKE FINAL PIPING <br />CONNECTION TO WATER FILTER. <br />NOTES TO WATER HEATER INSTALLER: <br />1. POSITION VALVES AND TRIM IN MECH ROOM SUCH THAT VALVES AND TRIM ARE <br />UNOBSTRUCTED TO VIEW AND SO THAT ACCESS FOR OPERATION OR REPAIR IS POSSIBLE <br />WITHOUT USE OF STEP LADDERS OR NEED TO DISASSEMBLE ANY COMPONENTS. <br />2. VENT HEATER UP THRU MECH ROOM ROOF AND PROVIDE FRESH AIR PIPING PER <br />MANUFACTURER'S RECOMMENDATIONS. <br />1" HW. SEE 1/P-201 FOR <br />CONTINUATION. <br />SURFACE MOUNTED PIPING. <br />OFFSET UPWARD AS <br />NEEDED TO ACCOMMODATE <br />VALVES, EXPANSION TANK, <br />ETC. <br />VACUUM RELIEF VALVE, P-17. <br />UNION, TYPICAL. PROVIDE <br />DIELECTRIC TYPE AT DISSIMILAR <br />PIPING MATERIALS. PROVIDE <br />HEAT TRAP NIPPLES IN VERTICAL <br />DROPS NEAR TANK. 10 <br />1 <br />Elii.l�i9 <br />HARD PIPE FINAL <br />CONNECTION, NO FLEX PIPE. <br />GAS SUPPLY PIPING <br />FROM ROOF. <br />FULL LINE 90 GAS <br />SIZE DIRT LEG COCK <br />u <br />PIPING AT WATER HEATER <br />NOT TO SCALE <br />1/2" HWR. SEE 1/P-201 FOR 1" CW. SEE 1/P-201 FOR <br />CONTINUATION. �— CONTINUATION. <br />1. FIXTURE CONNECTION SCHEDULE <br />MARK <br />FIXTURE <br />FW <br />FW2 <br />CW <br />HW <br />WASTE <br />P-1 <br />WATER CLOSET - FLOOR MOUNT (1.28 GPF) <br />X <br />X <br />1" <br />X <br />3" <br />P-2 <br />WATER CLOSET - ADA FLOOR MOUNT (1.28 GPF) <br />X <br />X <br />1" <br />X <br />3" <br />P-3 <br />URINAL - ADA WALL HUNG (0.125 GPF) <br />X <br />X <br />3/4" <br />X <br />2" <br />P-4 <br />LAVATORY - ADA COUNTERTOP (0.50 GPM) <br />X <br />X <br />1/2" <br />1/2" <br />1-1/4" <br />P-5 <br />KITCHEN HAND SINK - WALL HUNG (1.0 GPM) <br />X <br />X <br />1/2" <br />1/2" <br />1-1/2" <br />P-6 <br />SINGLE COMP SINK - COUNTERTOP (1.0 GPM) <br />X <br />X <br />1/2" <br />1/2" <br />1-1/2" <br />P-7 <br />MOP SINK <br />X <br />X <br />1/2" <br />1/2" <br />3" <br />P-8 <br />VEGETABLE PREP SINK (0.65 GPM SPRAYER) <br />X <br />X <br />1/2" <br />1/2" <br />(2) 1-1/2" <br />P-9 <br />POT SINK (0.65 GPM SPRAYER) <br />X <br />X <br />(2) 1/2" <br />(2) 1/2" <br />(4) 1-1/2" <br />P-10 <br />FLOOR DRAIN (ROUND TOP) <br />X <br />X <br />X <br />X <br />3" <br />P-11 <br />WALL HYDRANT (NON FREEZE) <br />X <br />X <br />3/4" <br />X <br />X <br />P-12 <br />FUNNEL DRAIN (3") <br />X <br />X <br />X <br />X <br />3" <br />P-13A <br />FLOOR SINK (4") 12" TOP <br />X <br />X <br />X <br />X <br />4" <br />P-13B <br />FLOOR SINK (3") 8" TOP <br />X <br />X <br />X <br />X <br />3" <br />P-14 <br />CLEANOUT INSIDE BUILDING <br />X <br />X <br />X <br />X <br />SEE PLAN <br />P-15 <br />CLEANOUT OUTSIDE BUILDING <br />X <br />X <br />X <br />X <br />SEE PLAN <br />P-16 <br />3-WAY VALVE/ VACUUM BREAKER <br />X <br />X <br />3/4" <br />3/4" <br />X <br />P-17 <br />VACUUM RELIEF VALVE <br />X <br />X <br />3/4" <br />X <br />X <br />P-18 <br />EXPANSION TANK <br />X <br />X <br />3/4" <br />X <br />X <br />P-19 <br />WATER HEATER <br />X <br />X <br />1" <br />1" <br />X <br />P-20 <br />THERMOMETER <br />X <br />X <br />X <br />1/2" <br />X <br />P-21 <br />BACKFLOW PREVENTER <br />X <br />X <br />1-1/2" <br />X <br />X <br />P-22 <br />MOP SINK CHECK VALVES <br />X <br />X <br />1/2" <br />1/2" <br />X <br />P-23 <br />UTILITY CONNECTION (ICE MAKER) <br />X <br />1/2" <br />X <br />X <br />X <br />P-24 <br />UTILITY CONNECTION (COFFEE & TEA) <br />1/2" <br />X <br />X <br />X <br />X <br />P-25 <br />SHOCK ABSORBER <br />1/2" <br />1/2" & 3/4" <br />1/2" <br />1/2" <br />X <br />P-26 <br />FUNNEL DRAIN <br />X <br />X <br />X <br />X <br />3" <br />P-26A <br />TRAP SEAL PROTECTOR <br />X <br />X <br />X <br />X <br />3" <br />P-27 <br />WATER PRESSURE GAUGE <br />X <br />X <br />1/4" <br />X <br />X <br />P-28 <br />BALL VALVE-CARBONATOR STOP/BFP PANEL <br />3/4" <br />X <br />X <br />X <br />X <br />P-29A <br />ICE MACHINE TRENCH DRAIN (18") <br />X <br />X <br />X <br />X <br />4" <br />P-29B <br />ICE MACHINE TRENCH DRAIN (36") <br />X <br />X <br />X <br />X <br />4" <br />P-30 <br />FILTERED WATER FAUCET <br />(2) 1/2" <br />X <br />X <br />X <br />X <br />P-31 <br />DUMPSTER POST HYDRANT <br />X <br />X <br />3/4" <br />X <br />X <br />P-32 <br />DUMPSTER DRAIN <br />X <br />X <br />X <br />X <br />3" <br />P-33 <br />TRAP PRIMER (MECHANICAL TYPE) <br />X <br />X <br />1/2" <br />X <br />X <br />P-34 <br />DISPENSER BACKFLOW PREVENTER <br />1/2" <br />X <br />X <br />X <br />X <br />P-35 <br />FLOOR DRAIN <br />X <br />X <br />X <br />X <br />3" <br />P-36 <br />BEVERAGE TOWER INDIRECT RECEIVER <br />X <br />X <br />X <br />X <br />3" <br />P-37 <br />FLOOR DRAIN (SQUARE TOP) <br />X <br />X <br />X <br />X <br />3" <br />P-38 <br />HOT WATER CIRCULATING PUMP <br />X <br />X <br />X <br />1/2" <br />X <br />P-39 <br />PRESSURE REDUCING VALVE <br />X <br />X <br />2" <br />X <br />X <br />P-40 <br />WYE STRAINER <br />X <br />X <br />2" <br />X <br />X <br />P-41 C <br />DISHWASHER SUPPLY VALVES - CHAMPION <br />X <br />X <br />3/4" <br />X <br />X <br />P-42 <br />EMERGENCY EYEWASH MIXING VALVE <br />X <br />X <br />1/2" <br />1/2" <br />X <br />P-43 <br />RETHERMALIZER SUPPLY VALVE <br />X <br />X <br />3/4" <br />X <br />X <br />P-44 <br />LAVATORY - ADA WALL HUNG (0.50 GPM) <br />X <br />X <br />1/2" <br />1/2" <br />1-1/4" <br />NOTES: 1) REFER TO FOOD SERVICE DRAWINGS FOR KITCHEN EQUIPMENT INSTALLATION AND HOOK-UP <br />RESPONSIBILITIES. <br />2O DO NOT MANIFOLD POT OR PREP SINK DRAINS TOGETHER UNLESS ALLOWED BY LOCAL AUTHORITY. <br />AQUASTAT. PLUMBING CONTRACTOR <br />A <br />" TO MOUNT AND WIRE. LOCATE WITHIN CW TO <br />SEE 1/P-20 <br />l'-0" OF WALL PENETRATION. SE <br />1" HWR X 8" LONG <br />MECH. <br />REQUIRED AT AQUASTAT. <br />EXTERIOR WALL <br />- - <br />P-20 THERMOMETER, <br />TYPICAL OF TWO. <br />O <br />P-38 HW RECIRC PUMP WITH <br />- <br />INTEGRAL CHECK VALVE. <br />�- <br />_ <br />1" FULL PORT BALL VALVE WITH <br />O <br />1" DIA NIBCO MODEL T-480 RING <br />O <br />CHECK VALVE OUTLINE OF 30" WII <br />© <br />CLEAR SPACE ON V <br />1/2" BOILER <br />WALL SPACE INTEN <br />1 <br />DRAIN <br />BOOSTER PUMP IF <br />EXPANSION TANK, P-18. LOCATE 2 X 6 SUPPORT BLC <br />NEAR WALL. SWING HORIZONTAL TYPICAL AT TOP, M <br />CW PIPING TO LOCATE 1" CW CLEAR SPACE. COC <br />DROP AS CLOSE TO WALL AS CONTRACTOR TO E <br />41 <br />POSSIBLE. SEE 1/P-201. PUMP PANEL SUPP, <br />T&P VALVE PIPED FULL SIZE TO DRAIN <br />WITH TYPE 'L' COPPER. ROUTE OUTSIDE <br />BLDG WHERE REQUIRED BY CODE. P-40 WYE STRAINEI <br />MESH SCREEN, STF <br />LAMINATED VALVE AND BLOW DOWN E <br />TAG LEGEND <br />1" CW <br />BALL VALVE, WITH' <br />PLACE 1/2" QUARRY TILE SPACERS SEE VALVE TAG DE <br />BENEATH WATER HEATER TO ELEVATE <br />WATER HEATER 1" OFF FLOOR. <br />NOTE OF SPECIAL IMPORTANCE: <br />1. LOCATIONS OF 2" CW RISER AND CLEAR SPACE ARE DIMENSIONED BECAUSE THEY <br />ARE CRITICAL FOR THE FUTURE PUMP PANEL INSTALLATION. <br />2. GENERAL CONTRACTOR SHALL ENSURE OTHER TRADES SHALL NOT INSTALL ANY <br />OTHER BUILDING COMPONENT WITHIN CLEAR SPACE OR WITHIN 10" OF EDGES. <br />^vvvv r- IV I FvrN <br />CONTINUATION. <br />PIPING AT WATER SERVICE ENTRANCE IN MECHANICAL ROOM <br />NOT TO SCALE <br />J-BOX LOCATION FOR FUTURE <br />BOOSTER PUMP. COORDINATE <br />LOCATION WITH GC AND <br />ELECTRICIAN PRIOR TO WALL <br />ROUGH -IN. J-BOX, CONDUIT, AND <br />CONDUCTORS BY ELECTRICAL. <br />1" CW TO WALL HYDRANT AND <br />DUMPSTER POST HYDRANT. <br />SEE 1/P-201 FOR CONTINUATION. <br />2" CW TO RESTROOMS AND <br />KITCHEN. SEE 1/P-201 FOR <br />CONTINUATION. <br />1" CW TO WATER FILTER. SEE <br />5/P-303 FOR CONTINUATION. <br />4LVE DRAIN. <br />IITH OUTLET V-0" AFF. <br />E <br />o D <br />� ° 0 C) CD <br />Chick-fil-A <br />5200 Buffington Road <br />Atlanta, Georgia <br />30349-2998 <br />Kurzynske <br />& Associates <br />2900 Lebanon Pike, Ste 201 <br />Nashville, Tennessee 37214 <br />Telephone: (615) 255-5203 <br />Fax: (615) 255-5207 <br />D Email: mail@kurzynske.com <br />{`�{{IkURZ <br />Itlttttl� <br />+`4 GE <br />No.53568 •'--.0 <br />'• STATE OF : �►s <br />�, •.��,� O R � p .• � e`er <br />',:x01VAIL {'lizoo. <br />This item has been electronically signed <br />and sealed by Mark T. Kurzynske, PE <br />on the date shown using a Digital <br />Signature. Printed copies of this <br />document are not considered signed <br />and sealed and the signature must be <br />verified on any electronic copies. <br />Digitally <br />signed by <br />Mark T <br />Mark T Kurzynske <br />KurzynskeDate: <br />2020.11.25 <br />C <br />10:40:11 <br />06'00' <br />CIO <br />U. 0 r <br />W <br />Um to a M <br />J > <br />1 J J <br />J U. <br />0 <br />to J <br />J = <br />0 <br />0 <br />B � W <br />N tiN <br />FSR#04040 <br />BUILDING TYPE / SIZE: P13 LC ALL <br />RELEASE: v2.20.02 <br />REVISION SCHEDULE <br />NO. DATE DESCRIPTION <br />1 11 /25/2020 For Bid <br />CONSULTANT PROJECT# <br />20090.CC.S <br />A <br />PRINTED FOR <br />PERMIT <br />DATE <br />07/27/2020 <br />H <br />DRAWN BY <br />DSF <br />Information contained on this drawing and in all digital files <br />produced for above named project may not be reproduced in <br />any manner without express written or verbal consent from <br />authorized project representatives. <br />W <br />SHEET <br />DETAILS AND <br />a <br />SCHEDULES <br />SHEET NUMBER <br />P=303 <br />4 <br />2 <br />1 <br />