4 <br />3 <br />2 1 1 <br />SUPPLY/ RETURN / EXHAUST DUCT <br />ATTACH HANGERS TO STRUCTURE. <br />E 1" WIDE GALVANIZED STRAP <br />FLEXIBLE DUCT INSTALLED 48" O.C. MAX <br />48" LONG MAX RIGID HARD PIPE <br />RIGID 90 DEGREE FITTING AND RISER. <br />ADJUST HEIGHT TO MEET TAKE -OFF <br />ELEVATION. NO FLEX IN DROP ALLOWED. <br />WRAP ALL UNINSULATED PORTIONS <br />OF AIR DEVICE AND NECK PER <br />ADJUST HEIGHT OF RISER TO SPECIFICATIONS ON M-901. <br />MEET TAKE -OFF ELEVATION OVERLAP ALL JOINTS BY 3". DO NOT <br />TAPE INSULATION TO THE GRID. <br />'GALVANIZED STRAP `-SEE SPIN -IN COLLAR <br />INSTALLED PER SMACNA DETAIL THIS SHEET <br />SAG/RAG/GRILLE TAKE -OFF <br />NOT TO SCALE <br />FABRICATE 18 GA STAINLESS NOZZLE. NOZZLE <br />INLET FULL SIZE OF FAN DISCHARGE. MINIMUM <br />NOZZLE HEIGHT 1'4'. EXTEND NOZZLE AS NEEDED <br />TO TERMINATE 0'-2" ABOVE TOP OF ALL CONDENSING <br />UNITS, RTUS, AND PARAPETS WITHIN 10'-0". <br />10 DEGREES <br />BOLTED <br />AND <br />GASKETED <br />FACTORY NEMA 3R <br />DISCONNECT <br />INSIDE HOUSING - <br />CONTRACTOR IS RESPONSIBLE <br />FOR DESIGN AND SUPPLY OF <br />ALL CURB ATTACHMENT o <br />C DETAILS IN ACCORDANCE WITH o <br />APPLICABLE BUILDING CODES, o <br />AND TO SUBMIT CURB AND <br />ATTACHMENT INFORMATION AS <br />NOTED ON 'G' SHEET <br />SUBMITTAL SCHEDULE. <br />B <br />EQUIPMENT RAIL 10 <br />INSTALL ROOFTOP SOLUTIONS G2 \-- PROVIDE 1.5 PCF <br />DRIP GUARD AS CLOSE AS POSSIBLE BATT INSULATION, <br />TO FAN SCROLL DRAIN. EXTEND MINIMUM 4" THICK. <br />DRAIN TO CENTER OF DRIP GUARD. <br />KITCHEN HOOD EXHAUST FANS <br />NOT TO SCALE <br />SECURE FAN TO CURB WITH HEX WASHER HEAD SELF - <br />DRILLING SCREW (#12 x 2"). THE FASTENERS SHALL BE 2" <br />FROM EACH CORNER OF THE FAN BASE AND THE <br />DISTANCE BETWEEN FASTENERS SHALL BE 4" OR LESS. <br />MINIMUM 5 FASTENERS PER SIDE OF CURB. ALL <br />FASTENERS ARE TO BE HIGH QUALITY CORROSION <br />RESISTANT STEEL OR STAINLESS STEEL. <br />SECURE CURB TO WOOD ROOF STRUCTURE WITH STEEL <br />LAG BOLTS NOMINAL SIZE OF 5/16" DIA. OR LARGER. <br />WOOD IS TO BE 4" NOMINAL SIZE OR GREATER. THE BOLT <br />SHALL HAVE A MINIMUM OF 3" THREAD ENGAGEMENT AND <br />SHALL BE AT LEAST 1-1/2" FROM MATERIAL EDGE. <br />MINIMUM 5 FASTENERS EACH SIDE OF CURB. <br />ELECTRICAL <br />DISCONNECT <br />LOCATED <br />INSIDE MOTOR <br />COMPARTMENT <br />BIRDSCREEN ' <br />PRE -FABRICATED 1'-0" MIN. <br />CURB l <br />TRANSITION OUT <br />TO ALLOW <br />BACKDRAFT <br />CLEAR ACCESS <br />DAMPER BY <br />TO ELECTRICAL <br />MECHANICAL. <br />RACEWAY IN FAN <br />COORDINATE <br />LOCATION <br />FLEXIBLE CONDUIT THRU <br />DUCT UP TO FACTORY <br />WITH CONDUIT. <br />RACEWAY IN FAN <br />RESTROOM EXHAUST <br />FAN <br />NOT TO SCALE <br />CHICK-FIL-A HAS A NATIONAL ACCOUNT WITH TOM BARROW COMPANY FOR THE ROYAL <br />METAL PRODUCTS START COLLARS FOR BOTH WITH AND WITHOUT A MANUAL BALANCING <br />DAMPER. THE MECHANICAL CONTRACTOR IS REQUIRED TO PURCHASE THE ROYAL METAL <br />PRODUCTS START COLLARS DIRECTLY FROM TOM BARROW COMPANY. CONTACT MR. SCOTT <br />GEORGE AT 404-351-1010 FOR PRICING AND AVAILABILITY. ROYAL METAL PRODUCTS START <br />COLLARS NOT PURCHASED THRU TOM BARROW COMPANY WILL NOT BE ACCEPTED, <br />DAMPER CONTROL HANDLE MUST BE <br />EXPOSED, LOCATED ON THE LEFT OR RIGHT <br />(9 OR 3 O'CLOCK) SIDE WHEN INSTALLED ON <br />HORIZONTAL DUCTS, AND LOCATED ON THE <br />BOTTOM (6 O'CLOCK) WHEN INSTALLED ON <br />VERTICAL DUCTS. DAMPER CONTROL <br />HANDLES NOT INSTALLED IN THE CORRECT <br />ORIENTATION AS SPECIFIED ABOVE WILL <br />NOT BE ACCEPTED. ATTACH YELLOW <br />FLUORESCENT CONSTRUCTION RIBBON TO <br />THE HANDLE. RIBBON MUST BE 12" LONG <br />AND BE EASILY IDENTIFIABLE FOR TEST AND <br />BALANCE CONTRACTOR. <br />ROYAL METAL PRODUCTS <br />STICK -ON START COLLAR. <br />START COLLAR <br />NOT TO SCALE <br />ALL DUCTWORK AND UNFINISHED METAL ON ROOF EXCEPT STAINLESS SHALL BE PREPARED <br />WITH TWO COATS OF SHERWIN WILLIAMS B66-200 SERIES DTM WHITE ACRYLIC SEMI -GLOSS <br />INDUSTRIAL MAINTENANCE COATING. DEGREASE AND PRIME BARE METAL SURFACE WITH <br />ONE COAT OF SHERWIN WILLIAMS DTM ACRYLIC PRIMER PRIOR TO PAINTING. <br />KEYED NOTES: <br />O EQUIPMENT CURB/RAILS AND CURB CAP (WHERE APPLICABLE) SHALL BE PROVIDED <br />BY GENERAL CONTRACTOR. WHERE CURB IS USED: WIDTH OF CURB SHALL BE 4" <br />WIDER THAN FAN FOOTPRINT IN BOTH DIRECTIONS. HEIGHT OF CURB/RAILS SHALL <br />BE SUCH THAT NO PART OF ANY DUCT SHALL BE WITHIN 18" OF ROOF SURFACE. <br />O2 ALL DUCT ON ROOF TO BE SUPPORTED WITH MIRO STANCHIONED DUCT SUPPORT <br />SYSTEM FOR SEISMIC APPLICATIONS AT 6'-0" INTERVALS MAXIMUM. SECURE <br />STANCHION BASE TO ROOF WITH MIN. (4) 3/8" LAG BOLTS. BOLT LENGTH SHALL BE <br />SUCH TO PROVIDE MINIMUM 3" PENETRATION IN BLOCKING BELOW THE PLYWOOD <br />ROOF DECK. PROVIDE A DUCT SUPPORT STAND AT EACH ROOF PENETRATION. <br />O MINIMUM 12" HIGH INSULATED CURB PROVIDED BY GENERAL CONTRACTOR. <br />CONTRACTOR TO PROVIDE 16 GA MINIMUM CURB CAP. <br />BOLTED AND GASKETED <br />TO FAN. 150OF RATED. <br />0/1 <br />a JD <br />24" MIN. FROM ROOF DECK. <br />ROOF ROOF <br />DECK-\ SURFACE -� <br />DO NOT APPLY START <br />COLLAR OVER DUCT WRAP <br />MINIMUM 1'-0" OF RIGID <br />DUCT AFTER SPIN -IN. <br />2" STANDOFF BRACKET <br />*--DAMPER CONTROL HANDLE <br />MAIN OR BRANCH MAIN <br />STICK -ON FITTINGS MUST <br />AIR FLOW BE SECURED WITH A <br />SCREW AT EVERY <br />PREPUNCHED HOLE. <br />SEE M-250 FOR GREASE SEE ROOF PLAN FOR <br />EXHAUST DUCT SIZE. GREASE ACCESS DOOR <br />QUANTITY AND TYPE, TYP. <br />4 D SEE ROOF PLAN FOR GREASE <br />ACCESS DOOR QUANTITY AND <br />TYPE, TYP. <br />FULL PERIMETER LIQUID TIGHT WELD <br />BETWEEN CURB CAP AND DUCT. <br />GREASE EXHAUST DUCT IS <br />CONTINUOUS THRU CURB CAP. <br />BLOCKING BY GENERAL CONTRACTOR <br />SUPPORT DUCT FROM STRUCTURE WITH <br />1-1/2"X1/8" STEEL ANGLE OR B-LINE B24 <br />STRUT AND 3/8" ATR ON 6'-0" CENTERS, TYP. <br />TURNING VANE SCHEDULE <br />R <br />SP <br />GA <br />2" <br />1.5" <br />24 <br />1. NO TRAILING EDGE. <br />2. SINGLE THICKNESS <br />CONSTRUCTION. <br />CE <br />i <br />450 FITTING 900 FITTING <br />TURNING VANES <br />NOT TO SCALE <br />CURB FOR DUCTS SERVING EF#1: <br />22.5" SQ. INSIDE CLEAR MINIMUM <br />CURB FOR DUCTS SERVING EF#2: <br />19.5" SQ. INSIDE CLEAR MINIMUM <br />CONTACT <br />CLOSUF <br />WHEN C <br />OPENS. <br />ROOF SEE PLAN FOR <br />DECK-� DUCT SIZE <br />GAS FIRED ROOFTOP UNIT SCHEDULE <br />TOTAL <br />SENSIBLE <br />HEATING <br />HEATING <br />COOLING <br />COOLING <br />INPUT <br />OUTPUT <br />MODEL <br />MARK <br />MBH <br />MBH <br />MBH <br />MBH <br />STAGES <br />SUPPLY <br />O.A. <br />HP <br />ESP <br />R-410A <br />MANUFACTURER <br />REMARKS <br />AC#1 <br />288.4 <br />219.2 <br />480 <br />384 <br />1 2 3 <br />9500 <br />1180 <br />10 <br />0.80 <br />LG H 300S4 B <br />LENNOX <br />1, 3,4, 5, 7, 8, 9,10,11,12,13,14,15,16 <br />AC#2 <br />208.9 <br />160.9 <br />240 <br />192 <br />1 2 <br />1 5300 <br />1152513 <br />0.65 <br />LG H210 H4B <br />LENNOX <br />1, 3, 4, 5, 7, 8, 9,10,11,12,13,14,15,16 <br />AC#3 <br />247.3 <br />192.9 <br />480 <br />384 <br />1 2 <br />1 6000 <br />1175015 <br />0.65 <br />LG H240 H4B <br />LENNOX <br />1, 3, 4, 5, 7, 8, 9,10,11,12,13,14,15,16 <br />NOTES <br />0 <br />COOLING CAPACITIES ARE GROSS, BASED ON ENTERING: 80FDB/67FWB, OUTDOOR: 95FDB, AND 400 CFM PER TON. <br />• <br />CHICK-FIL-A MAINTAINS A NATIONAL ACCOUNT FOR EQUIPMENT WITH LENNOX CORPORATION. CONTACT LENNOX <br />NATIONAL ACCOUNTS AT 800-367-6285 (OR BY FAX AT 972-497-5112) FOR PRICING, ORDERING AND AVAILABILITY. <br />• <br />MECHANICAL CONTRACTOR TO VERIFY LENNOX SUBMITTAL WITH CONSTRUCTION DOCUMENTS. <br />REMARKS <br />1. <br />PROVIDE DIFFERENTIAL ENTHALPY ECONOMIZER WITH POWER EXHAUST. <br />2. <br />NOT USED. <br />3. <br />PROVIDE 14" HIGH ROOF CURB.PROVIDE CURBS PLUS RESTRAINT CLIP KIT. <br />4. <br />SEE DETAIL 2/M-501 FOR SETTING OF PRODIGY M3 BOARD CONTROL PARAMETERS BY MC. <br />5. <br />PROVIDE FACTORY INSTALLED AND UNIT POWERED 115V GFI SERVICE OUTLET. <br />6. <br />NOT USED. <br />7. <br />PROVIDE FACTORY INSTALLED RETURN SIDE SMOKE DETECTOR. <br />8. <br />PROVIDE FACTORY INSTALLED NON -FUSED DISCONNECT. <br />9. <br />PROVIDE 2" MERV 8 THROW AWAY FILTERS. <br />10. <br />PROVIDE HINGED PANELS FOR FILTER ACCESS, FAN MOTOR ACCESS, COMPRESSOR ACCESS AND CONTROL <br />COMPARTMENT ACCESS. <br />11. <br />ADJUST GAS MANIFOLD PRESSURE AT LOCATIONS WHERE ELEVATION EXCEEDS 2000' ABOVE SEA LEVEL AS <br />RECOMMENDED BY MANUFACTURER. <br />12. <br />PROVIDE FACTORY COIL HAIL GUARD, FIELD INSTALLED. <br />13. <br />PROVIDE FACTORY INSTALLED CONDENSATE PAN DRAIN OVERFLOW SWITCH. <br />14. <br />PROVIDE HUMIDITROL OPTION WITH FACTORY WALL MOUNTED HUMIDITY SENSOR. <br />15. <br />PROVIDE FACTORY INSTALLED BELT TENSIONER. <br />16. <br />PROVIDE FACTORY CONFIGURED PHASE LOSS PROTECTION. <br />EXHAUST FAN SCHEDULE <br />MARK <br />CFM <br />ESP <br />RPM <br />Tip Speed <br />HP <br />Area Served <br />MODEL <br />MANUFACTURER <br />REMARKS <br />EF#1 <br />1912 <br />0.75 <br />1,331 <br />5,231 <br />3/4 <br />HOOD#1L & HOOD#1R <br />150 CPS <br />LOREN COOK <br />1,2,3,4,5,6,7,8,9,10,11,17 <br />EF#2 <br />1091 <br />0.85 <br />1,311 <br />4,637 <br />1/2 <br />HOOD#2 & HOOD#3 <br />135 CPS <br />LOREN COOK <br />1,2,3,4,5,6,7,8,9,10,11,17 <br />EF#3 <br />300 <br />0.375 <br />1 1,294 <br />3,091 <br />1/8 <br />RESTROOMS <br />ACED-90C 15DH <br />I LOREN COOK <br />3,11,12,13,14,15,16 <br />NOTES <br />0 <br />GREASE EXHAUST FAN RPM BASED ON 80 DEGREE F AIR AT 1000 FEET ABOVE SEA LEVEL. <br />• <br />GREASE EXHAUST FANS TO BE U.L. 762 LISTED. <br />• <br />CHICK-FIL-A HAS A NATIONAL ACCOUNT WITH TOM BARROW COMPANY FOR THE FAN/CURB PACKAGE. THE MECHANICAL <br />CONTRACTOR IS REQUIRED TO PURCHASE THE FAN/CURB PACKAGE DIRECTLY FROM TOM BARROW COMPANY. CONTACT MR. <br />SCOTT GEORGE AT 404-351-1010 FOR PRICING AND AVAILABILITY. FANS AND CURBS NOT PURCHASED THRU TOM BARROW <br />COMPANY WILL NOT BE ACCEPTED. <br />REMARKS <br />1. <br />UPBLAST, ARRANGEMENT 10, CCW ROTATION. SEE PLANS TO CONFIRM CONFIGURATION. <br />2. <br />PROVIDE FACTORY STEEL FAN WHEEL. <br />3. <br />PROVIDE FACTORY INSTALLED, PRE -WIRED, NEMA 3 NON -FUSED DISCONNECT. <br />4. <br />PROVIDE FACTORY STEEL INLET FLANGE AND INLET COMPANION FLANGE. <br />5. <br />PROVIDE AND INSTALL ROOFTOP SOLUTIONS G2 DRIP GUARD. MECHANICAL CONTRACTOR TO CONTACT <br />ROOFTOP SOLUTIONS AT 800-913-7034. <br />6. <br />PROVIDE FACTORY WEATHER HOUSING W/ HINGED ACCESS DOOR. <br />7. <br />PROVIDE FACTORY DRAIN CONNECTION. <br />8. <br />PROVIDE FACTORY BOLTED ACCESS DOOR ON SCROLL. <br />9. <br />PROVIDE FACTORY INSTALLED BELT DRIVE WITH ADJUSTABLE MOTOR SHEAVE AND SPARE BELT.. <br />10. <br />PROVIDE FACTORY STEEL OUTLET COMPANION FLANGE. <br />11. <br />INTEGRAL THERMAL OVERLOAD WITH AUTOMATIC RESET. <br />12. <br />PROVIDE BIRDSCREEN. <br />13. <br />BACKDRAFT DAMPER IN DUCT BY MECHANICAL CONTRACTOR AS SHOWN ON 4/M401. <br />14. <br />STARTER BY ELECTRICAL CONTRACTOR. INTERLOCK WITH LIGHTS BY ELECTRICAL CONTRACTOR. <br />15. <br />PROVIDE 12" HIGH CURB. <br />16. <br />PROVIDE FACTORY INSTALLED AND WIRED SPEED CONTROLLER. <br />17. <br />UTILITY SET FAN CURB AND ASSOCIATED EXHAUST DUCT CURB PROVIDED BY TOM BARROW COMPANY. <br />30.00 MINA\ '�4 /30.00 MIN. <br />SEE PLAN FOR PLENUM SIZE <br />0 0 <br />co <br />CEILING APPROX.10" <br />TAKE -OFF, <br />TYP. <br />RETURN DROP GEOMETRY <br />NOT TO SCALE <br />LEGEND <br />18 AWG MIN LOW VOLTAGE WIRING BY MC, U.N.O. <br />22 AWG LOW VOLTAGE WIRING PROVIDED BY <br />TORMAX. WIRING INSTALLED BY MC. <br />- - - - - - - - - 7 <br />POWERED AIRE REMOTE AUTO I <br />FAN ON/AUTO SWITCH L 1 <br />MOUNTED ON WALL BY MC P I <br />- - - - - <br />r ON 1 <br />L - - - - <br />_ -- I I <br />TORMAX DOOR AIR CURTAIN <br />LOW VOLTAGE CONTROL _ <br />CIRCUIT MICRO SWITCH I- <br />Z L <br />w - - <br />o E_ <br />N.O. O <br />o ED - - BLACK - - <br />N.C. r _ <br />CAP WHITE WIRE I <br />I <br />POWERED AIRE REMOTE <br />HEAT ON/OFF SWITCH - J <br />MOUNTED ON WALL BY MC. �L----- <br />AIR CURTAIN WIRING DIAGRAM <br />NOT TO SCALE <br />POWERED AIR TERMINAL BOARD <br />- <br />1 <br />FAN ON/AUTO (AUTO)'. <br />® <br />2 <br />DOOR SWITCH <br />- <br />3 <br />FAN ON/AUTO (ON) <br />4 <br />FAN ON/AUTO (COM) I,I <br />6 <br />DOOR SWITCH <br />- <br />7 <br />HEAT ON/OFF <br />- <br />8 <br />HEAT ON/OFF <br />AIR DOOR SCHEDULE <br />MARK <br />CFM <br />VELOCITY <br />HEATING CAP <br />HP <br />AREA SERVED <br />MODEL <br />MANUFACTURER <br />REMARKS <br />AD#1 <br />1543 <br />2240 FPM <br />10 KW <br />3/4 HP <br />DRIVE THRU <br />CHA 1-48 <br />Powered Aire <br />1,2,3 <br />AD#2 <br />3867 <br />4220 FPM <br />N/A <br />3/4 HP <br />REAR DOOR <br />RBT-1-48 <br />Powered Aire <br />4 <br />NOTES <br />CHICK-FIL-A HAS A NATIONAL ACCOUNT WITH TOM BARROW COMPANY FOR THE AIR DOORS. THE <br />MECHANICAL CONTRACTOR SHALL PURCHASE THE AIR DOORS DIRECTLY FROM TOM BARROW <br />COMPANY. CONTACT MR. SCOTT GEORGE AT 404-351-1010, FOR PRICING AND AVAILABILITY. AIR <br />DOORS NOT PURCHASED THRU TOM BARROW COMPANY WILL NOT BE ACCEPTED. <br />REMARKS <br />1. FACTORY PROVIDED, WIRED, AND UNIT MOUNTED SPEED CONTROLLER LOCATED ABOVE <br />CEILING. <br />2. FACTORY WIRED DISCONNECT. <br />3. FACTORY PROVIDED, FIELD INSTALLED BY MC, REMOTE WALL SWITCHES FOR HEATING ON/OFF <br />AND FAN ON/AUTO SWITCH. SEE DETAIL, AIR CURTAIN WIRING DIAGRAM, THIS SHEET. <br />4. FACTORY PROVIDED MAGNETIC DOOR CONTACT WITH FACTORY INSTALLED LOW VOLTAGE <br />CONTROLS LOCATED IN AIR DOOR CABINET. <br />AIR DEVICE SCHEDULE <br />NECK <br />FACE <br />FRAME <br />MARK <br />DESCRIPTION <br />LOCATION <br />SIZE <br />SIZE <br />TYPE <br />REMARKS <br />A <br />PRICE MODEL APDC ALUMINUM SUPPLY AIR <br />DINING/ <br />VARIES <br />24"x24" <br />LAY -IN <br />1,7 <br />DIFFUSER WITH INDIVIDUALLY ADJUSTABLE <br />OFFICE/ <br />CURVED AIR PATTERN CONTROLLERS. <br />KITCHEN <br />C <br />PRICE MODEL SMCD STEEL SUPPLY AIR <br />ENTRY <br />14"x14" <br />19"x19" <br />BEVELLED <br />1,3,5,E <br />DIFFUSER FIELD ADJUSTABLE AIR PATTERN <br />CONTROLLERS. <br />F <br />PRICE MODEL 80 EGGCRATE RETURN AIR GRILLE <br />DINING/ <br />VARIES <br />24"x24" <br />LAY -IN <br />1,7 <br />WITH REMOVABLE WHITE CORE, FACTORY FLAT <br />OFFICE/ <br />BLACK BACKPAN AND ROUND NECK. <br />KITCHEN <br />J <br />PRICE MODEL SMCD STEEL SUPPLY AIR <br />RESTROOMS <br />10"x10" <br />15"x15" <br />BEVELLED <br />1,2,3,5,E <br />DIFFUSER FIELD ADJUSTABLE AIR PATTERN <br />CONTROLLERS. <br />K <br />PRICE MODEL APDDR ALUMINUM PERFORATED <br />RESTROOMS/ <br />14"x14" <br />16"x16" <br />SURFACE <br />1,4,5,E <br />FACE RETURN AIR GRILLE. <br />ENTRY <br />NOTES <br />CHICK-FIL-A HAS A NATIONAL ACCOUNT WITH TOM BARROW COMPANY FOR THE AIR <br />DEVICES. THE MECHANICAL CONTRACTOR SHALL PURCHASE THE AIR DEVICES DIRECTLY <br />FROM TOM BARROW COMPANY. CONTACT MR. SCOTT GEORGE AT 404-351-1010, FOR <br />PRICING AND AVAILABILITY. AIR DEVICES NOT PURCHASED THRU TOM BARROW COMPANY <br />WILL NOT BE ACCEPTED. <br />REMARKS <br />1. STANDARD OFF WHITE FINISH. <br />2. PROVIDE MODEL VCS3 NECK DAMPER. <br />3. SEE DRAWING M-201 FOR THROW. <br />4. PROVIDE MODEL VCR7 NECK DAMPER ON GRILLES IN RESTROOMS SERVING EXHAUST <br />FAN. <br />5. PROVIDE BACKPAN. MC TO SEAL JOINTS WITH MASTIC AND INSULATE EXTERNALLY. <br />6. FIELD INSULATE BACKPAN AS SHOWN ON DETAIL 1/M-401. <br />7. FACTORY INSULATED R-6 BACKPAN. <br />L <br />J <br />C <br />B <br />:> o <br />f e <br />Chick-fil-A <br />5200 Buffington Road <br />Atlanta, Georgia <br />30349-2998 <br />Kurzynske <br />& Associates <br />2900 Lebanon Pike, Ste 201 <br />Nashville, Tennessee 37214 <br />Telephone: (615) 255-5203 <br />Fax: (615) 255-5207 <br />Email: mail@kurzynske.com <br />MARK T. KURZYNSKE <br />FLORIDA LICENSE # 53568 <br />KU `�10111111'�f�1,F <br />• r <br />Auz <br />0 STATE • �.; <br />I. <br />�Baleeeettl% <br />03/29/2 1 <br />Q M <br />> M <br />W J <br />J LL <br />0 co <br />inJ <br />J J <br />J = <br />Q� <br />a� <br />O = <br />a, a <br />W <br />t` N <br />FSR#04040 <br />BUILDING TYPE / SIZE: P13 LC ALL <br />RELEASE: v2.20.02 <br />REVISION SCHEDULE <br />NO. DATE DESCRIPTION <br />Z <br />O <br />V <br />CONSULTANT PROJECT# 20090.CC.S <br />A /A <br />PRINTED FOR FOR CONSTRUCTION <br />z <br />DATE <br />07/29/2020 <br />ODRAWN <br />BY BLM <br />Information contained on this drawing and in all digital files <br />produced for above named project may not be reproduced in <br />any manner without express written or verbal consent from <br />authorized project representatives. <br />SHEET <br />HVAC DETAILS AND <br />LL <br />SCHEDULES <br />SHEET NUMBER <br />M=401 <br />4 I 3 I 2 <br />1 <br />