sommomwmm <br />Notes: <br />ROOFTOP UNIT <br />EXTEND TO NEAREST <br />OUTSIDE AIR INTAKE <br />ROOF DRAIN <br />SECURE CAP TO <br />FLEXIBLE <br />CURB WITH SHEET <br />CONNECTIO <br />METAL SCREWS 12" <br />CURB —MOUNTED ROOF CAP <br />O.C. AROUND <br />COOK MODEL PR SERIES. <br />PERIMETER <br />PREFABRICATED <br />PRESSURE TREATED <br />DEEP SEAL <br />ROOF CURB <br />BASE <br />FLASHING <br />WOOD NAILER <br />P—TRAP <br />PREFABRICATED, INSULATED <br />ROOF CURB. MOUNT AND <br />SECURE ON WOOD NAILER. <br />ti <br />ROOFING <br />72"0 THRU—BOLT W/ <br />MATERIAL <br />AND <br />= <br />SEAL PENETRATION <br />WITH <br />8 <br />ROOF INSULATION <br />DOUBLEWASHERSNUT AT EACH <br />MASTIC' <br />AA <br />CORNER OF ROOF I <br />TOP UNIT. <br />(2) X-0 <br />SCREW ATTACH CURB <br />THRU—BOLT W/ <br />TO ROOF PANEL W/ <br />WASHERS AND <br />MIN. )i SCREWS AT SUPPLY <br />DOUBLE NUT AT <br />6" ON CENTER. <br />RETURN <br />EACH CURB CAP <br />�2x4x1'-0" <br />SEAL ALL DUCTWORK OPENINGS <br />SCREW ATTACH CURB <br />WITH NONHARDING MASTICS. <br />TO ROOF PANEL W/ <br />MIN. )ie"O SCREWS AT <br />EXHAUST <br />TRANSITION DUCT AS REQ'D. TO MAIN SUPPLY AND RETURN. <br />6" ON CENTER. <br />DUCT, SEE <br />SHEET M 1.1 <br />PRESSURE TREATED <br />FOR DUCT <br />WOOD NAILER <br />SIZES. <br />CEILING <br />ROOF TOP UNIT DETAIL <br />1 <br />EXHAUST FAN DISCHARGE DETAIL 2 <br />SCALE: NONE <br />SCALE: NONE <br />TRUNK DUCT <br />FLEXIBLE DUCT (CLASS 1 AS <br />LISTED—U.L 181) <br />MAX. LENGTH <br />I <br />W <br />12" MINIMUM <br />((— <br />ROUND BRANCH <br />TAKEOFF FITTING W/ <br />VOLUME DAMPER <br />EQUAL <br />WIDTH <br />CEILING <br />DOUBLE THICKNESS <br />— <br />RADIUS WIDTH <br />TURNING VANES <br />SUPPLY AIR DIFFUSER OR RETURN <br />GRILLE TO MATCH CEILING TYPE. SUPPLY <br />AIR DIFFUSERS SHALL HAVE OPPOSED <br />BLADE DAMPER. <br />CEILING DIFFUSER DETAIL <br />3 <br />ELBOW DETAIL <br />4 <br />SCALE: NONE <br />SCALE: NONE <br />ROOFTOP UNIT <br />LOCATE S.P. PROBE <br />2" MERV 13 FILTER <br />BETWEEN FILTER AND COIL <br />TRUNK DUCT <br />FLEXIBLE DUCT (CLASS 1 AS <br />Opv <br />OUTSIDE AIR :NTAKE <br />LISTED—U.L. 181) <br />=p <br />MAXIMUM LENGTH 6'-0" <br />p� <br />FACTIORY INSULATED <br />PLENUM <br />Up <br />STATIC PRESSURE SENSOR <br />DWYER MODEL A-302. <br />POSITION AS RECOMMENDED <br />BY MANUFACTURER TO READ <br />STATIC PRESSURE. <br />VINYL TUBING IN t" EMT. <br />MAXIMUM LENGTH=10 FT. <br />ROUND BRANCH <br />TAKEOFF FITTING W/ <br />VOLUME DAMPER <br />UNISTRUT <br />CEILING <br />SUPPLY AIR SLOT DIFFUSER <br />on <br />FILTER MONITOR i <br />CONTROLLER) PANEL <br />DIFFERENTIAL PRESSURE <br />SEE DETAIL) / <br />TRANSMITTER PANEL <br />WALL MOUNT �--18 GA. PLENUM RATED <br />(SEE DETAIL) <br />@ 60" A.F.F. SHIELDED, TWISTED PAIR <br />CEILING <br />NOTES: <br />1. WIRE CONTROLLER IN ACCORDANCE WITH MANUFACTURER'S <br />INSTRUCTIONS. <br />2. CALIBRATE 4-20 mA SIGNAL TO CORRESPOND TO A READING OF <br />0.000 TO 2.000" W.C. <br />AND ADJUST DECIMAL POINT LOCATION. <br />3. SET ALARM POINT 1 (SP 1) AT 0.80" W.C. <br />4. SET ALARM POINT 2 (SP 2) AT 1.00" W.C. <br />ELECT. 4. PROVIDE ONE TRANSMITTER AND ONE PANEL FOR EACH RTU. <br />115 <br />SLOT DIFFUSER DETAIL <br />5 <br />FILTER MONITOR DETAIL <br />6 <br />SCALE: NONE <br />SCALE: NONE <br />PROVIDE PHENOLIC ENGRAVED <br />TO STATIC PRESSURE PROBES <br />NAMEPLATE NEAR FILTER MONITOR <br />" VINYL <br />TUBING IN t" EMT. <br />PANEL (WHITE LETTERS ON GREEN <br />FOLLOWS: <br />NAMEPLATE) READING AS <br />SP 1 INDICATOR LIGHT: APPROACHING FILTER CHANGE. <br />— <br />SP 2 INDICATOR LIGHT: DIRTY FILTER. CHANGE IMMEDIATELY. <br />18 GA. PLENUM RATED <br />18 GA. PLENUM RATED <br />SHIELDED, TWISTED PAIR <br />SHIELDED, TWISTED PAIR <br />TO CONTROLLER PANEL. <br />TO D.P. PANEL. <br />HI LO <br />DIFFERENTIAL PRESSURE <br />TRANSMITTER <br />PHENOLIC ENGRAVED <br />120v POWER WIRING & <br />120v POWER WIRING & <br />DWYER MODEL 616C-0 <br />0 0 <br />NAMEPLATE CONDUIT BY E.C. <br />RTU-X FILTER MON. <br />CONDUIT BY E.C. <br />0 TO 2" W.C. SCALE <br />ACCURACY: +/— 1 % F.S. <br />1 <br />DWYER/LOVE PROCESS FUSE IN ACCORDANCE <br />INDICATOR AND ALARM. 1. 0 <br />0 0 WITH MANUFACTURER'S <br />NEMA 1 PANEL, 8x8x6 <br />SERIES 1000 <br />INPUT: 100-240 VAC <br />INSTRUCTIONS <br />DWYER MOD. A-700 <br />AUTOMATION DIRECT <br />SP 1 <br />Sp CUT OPENING IN PANEL <br />24 VDC POWER SUPPLY. <br />0.5 AMP MAX. OUTPUT. <br />MODEL N1P0808 OR EQUAL <br />NEMA 1 SCREW COVER 0 <br />COVER. <br />0 REFER TO DWYER <br />AC INPUT: 100/200/220/230-240 VAC <br />FULL PIANO HINGE DOOR <br />PANEL <br />AUTOMATION DIRECT <br />INSTRUCTION MANUAL. <br />DC OUTPUT: 24-28 VDC <br />MOD. SC060806 OR <br />Differential Pressure Transmitter Panel <br />EQUAL. <br />Filter Monitor (Controller) Panel <br />DP TRANSMITTER PANEL DET41L % <br />FILTER MONITOR PANEL <br />DETAIL 8 <br />SCALE: NONE <br />SCALE: NONE <br />65 I <br />E <br />1 " PVC AC CONDENSATE <br />PIPING. PROVIDE MIRO <br />INDUSTRIES MODEL 1.5 <br />PIPE SUPPORTS . <br />SPACING SHALL NOT <br />EXCEED 4'-0". <br />i <br />d� <br />COORDINATE ROOF DRAIN <br />70 <br />LOCATIONS WITH <br />O _ ARCHITECTURAL DRAWINGS. <br />I <br />I III li I <br />I <br />�I <br />I <br />1" PVC AC CONDENSATE 69 <br />PIPING. PROVIDE MIRO <br />INDUSTRIES MODEL 1.5 <br />PIPE SUPPORTS . <br />SPACING SHALL NOT <br />EXCEED 4'-0". <br />I <br />COORDINATE ROOF DRAIN <br />LOCATIONS WITH <br />ARCHITECTURAL DRAWINGS. <br />ii <br />i <br />II, i� II <br />II ICI <br />i <br />� I , <br />/ <br />h' I <br />-- - -- --- — -- -mo <br />NORTH t, <br />MECHANICAL - ROOF PLAN <br />SCALE: 1 — V-0" <br />Revisions: <br />Seal: <br />Consultants: <br />0 <br />ARCHITECTURAL ENGINEERING INCORPORATED <br />3442 EAST LAKE ROAD, PALM HARBOR, FL 34685 <br />CONSULTING ENGINEERS (727) 784-1472 <br />CERTIFICATE OF AUTHORIZATION: FL 3886 <br />W. RONALD MCILVEEN FL PE 30270 <br />