GENERAL ELECTRICAL NOTES (ALL "E" DRAWINGS): <br />1 A. REGULATORY REQUIREMENTS: PROVIDE ALL WORK TO MEET OR EXCEED MINIMUM REGULATORY REQUIREMENTS <br />INCLUDING: <br />FLORIDA BUILDING CODE: 2004 EDITION WITH 2O06 SUPPLEMENT <br />FLORIDA FIRE PREVENTION CODE: 2006 EDITION <br />ADVISE THE PROJECT A/E OF ANY CHANGES IN THE CONTRACT DOCUMENTS THAT MAY BE REQUIRED IN ORDER TO <br />MEET CODE, PRIOR TO WORK (ORDERING, ROUGHING, OR INSTALLATION). <br />B. COORDINATION: COORDINATE WITH OTHER WORK FOR AVAILABLE SPACE, SEQUENCE OF INSTALLATION, AND <br />INSTALLATION REQUIREMENTS, PRIOR TO COMMENCING CONSTRUCTION. ADVISE THE PROJECT A/E OF ANY <br />CHANGES IN THE CONTRACT DOCUMENTS THAT MAY BE REQUIRED FOR THE WORK TO BE PERFORMED. <br />C. EXISTING FIELD CONDITIONS: THE CONTRACT DOCUMENTS INDICATE THE DESIGN INTENT USING AVAILABLE <br />INFORMATION. THE CONTRACTOR IS TO ADVISE THE PROJECT A/E IF EXISTING CONDITIONS DIFFER FROM THOSE <br />SHOWN. ALSO ADVISE THE PROJECT A/E IF CODE OR SAFETY CONFLICTS EXIST. THE CONTRACTOR IS REQUIRED <br />TO VISIT THE SITE (PRIOR TO THE BID) TO BECOME FAMILIAR WITH CONDITIONS AND INSTALLATION DETAILS THAT <br />WILL AFFECT HIS WORK. CHANGES IN THE CONTRACT SUM AND CONTRACT TIME WILL NOT BE ALLOWED FOR <br />FAILURE TO INVESTIGATE FIELD CONDITIONS. ALL WORK IS NEW, UNLESS NOTED OTHERWISE. <br />D. DEVICE LOCATIONS: COORDINATE THE LOCATIONS OF EXISTING LIGHTING FIXTURES, AND OTHER CEILING ITEMS IN <br />THE FIELD. ALSO COORDINATE LOCATIONS OF NEW DEVICES AND OTHER EXISTING WALL ITEMS IN THE FIELD. <br />LOCATE ALL CONDUITS AND WIRING IN FINISHED ROOMS OR SPACES WITHIN CONCEALED LOCATIONS (FURRED <br />CHASES OR SUSPENDED CEILINGS, AS AVAILABLE), UNLESS SPECIFICALLY NOTED OTHERWISE. <br />E. SIZES: WHEN A CONDUIT OR CONDUCTOR SIZE IS NOT INDICATED, SIZE THAT CONDUIT OR CONDUCTOR. USING <br />THE LARGER ADJACENT UPSTREAM SIZE (IN ACCORDANCE WITH THE NEC), UNLESS A SMALLER SIZE HAS BEEN <br />APPROVED BY THE PROJECT A/E. PROVIDE 1 /2 INCH MINIMUM CONDUIT SIZE, UNLESS SPECIFICALLY NOTED <br />OTHERWISE. FOR SIZES NOT INDICATED ON PLANS, REFER TO RISER DIAGRAMS AND OTHER LOCATIONS IN THE <br />CONTRACT DOCUMENTS (DRAWINGS AND SPECIFICATIONS) FOR INFORMATION. <br />2 THE ELECTRICAL CONTRACTOR SHALL OBTAIN ALL PERMITS AND PAY SUCH FEES, AS MAY BE NECESSARY FOR <br />INSPECTIONS, TESTS, AND OTHER SERVICES NECESSARY FOR THE COMPLETION OF THIS WORK. <br />3 CONTRACTOR SHALL VISIT THE SITE AND EXAMINE CONDITIONS OF THE PREMISES AND THE CHARACTER AND EXTENT OF <br />WORK REQUIRED PRIOR TO SUBMISSION OF BIDS. ANY DIFFICULTIES IN COMPLYING WITH THE DRAWINGS AND <br />SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT / ENGINEER BEFORE BIDDING. <br />4 IT IS THE INTENT OF THESE DRAWINGS AND OTHER RELATED DOCUMENTS TO PRODUCE A COMPLETE AND FUNCTIONING <br />ELECTRICAL SYSTEM. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIAL AND OTHER SERVICES AS <br />MAY BE NECESSARY TO ACHIEVE THIS PRODUCT. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO BRING TO <br />THE ATTENTION OF THE ARCHITECT ANY DISCREPANCIES IN THE PLANS AND SPECIFICATIONS THAT WILL AFFECT THE <br />WORK, PRIOR TO SUBMISSION OF HIS BID PRICE. <br />5 IF, DURING THE COURSE OF THE WORK, THE CONTRACTOR EXPERIENCES A PROBLEM WITH THE PERFORMANCE OF THE <br />INSTALLATION RELATIVE TO THE PLANS AND SPECIFICATIONS, THE NATIONAL ELECTRICAL CODE, OTHER APPLICABLE <br />CODES AND GOVERNING DOCUMENTS, THE CONTRACTOR SHALL BRING THE PROBLEM TO THE ATTENTION OF THE <br />ARCHITECT AND / OR THE ENGINEER FOR RESOLUTION PRIOR TO EXECUTION OF THE WORK. <br />6 ALL MATERIAL SHALL BE NEW AND BEAR THE U.L. LABEL LISTED APPROVAL FOR ITS INSTALLED APPLICATION. <br />7 ALL MAJOR COMPONENTS OF THE ELECTRICAL SYSTEMS, SUCH AS SAFETY DISCONNECT SWITCHES AND PANELBOARDS, <br />SHALL BE BY THE SAME MANUFACTURER AND SHALL BE ONE OF THE FOLLOWING: SQUARE "D" COMPANY, GENERAL <br />ELECTRIC, OR CUTLER —HAMMER. <br />8 CIRCUIT BREAKERS USED FOR SWITCHING OF LIGHTING OR SIGN CIRCUITS SHALL BE APPROVED FOR SWITCHING DUTY <br />AND SHALL BE MARKED "SWD" IN ACCORDANCE WITH N.E.C. ART. 240.83 (D). <br />9 PROVIDE "LOCKING" TYPE DEVICES ON ALL CIRCUIT BREAKERS CONNECTED TO EMERGENCY AND NIGHT LIGHTING, SIGNS, <br />FIRE ALARM, SECURITY SYSTEMS, AFTER HOUR DEPOSIT AND AUTOMATIC TELLER MACHINES. <br />10 ALL SWITCHES, DUPLEX RECEPTACLES, AND TELEPHONE OUTLETS TO BE FLUSH MOUNTED, THROUGHOUT. <br />11 ALL SERVICE EQUIPMENT SHALL BE GROUNDED IN ACCORDANCE WITH N.E.C. ARTICLE 250. <br />12 ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL CONTRACTOR FOR EXACT LOCATIONS OF HVAC <br />EQUIPMENT. <br />13 SEE REFLECTED CEILING PLAN FOR EXACT LOCATION OF LIGHT FIXTURES. <br />14 ELECTRICAL PLANS ARE DIAGRAMMATIC. DO NOT SCALE DRAWINGS. <br />15 CONSULT PLANS OF ALL OTHER TRADES FOR COORDINATION AND FOR RELATED AND ADJOINING WORK. <br />16 CONSULT ARCHITECTURAL AND STRUCTURAL PLANS AND DETAILS FOR CONSTRUCTION TYPE, HEADROOM, ROOM FINISHES, <br />CEILINGS, ETC. <br />17 ALL WORK SHALL BE DONE AT SUCH TIMES AND IN SUCH A MANNER AS WILL LEAST INTERFERE WITH THE <br />MAINTENANCE AND OPERATION OF ALL RELATED OR AFFECTED SYSTEMS. ALL POWER OUTAGES SHALL BE COORDINATED <br />WITH OWNER. <br />18 THE CORRECT NUMBER OF WIRES MAY NOT BE INDICATED FOR ALL CIRCUITS, ONLY THOSE WHERE CLARIFICATION IS <br />NECESSARY. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL WIRES NECESSARY FOR THE PROPER FUNCTION OF <br />THE SYSTEM. <br />19 ALL EMPTY CONDUIT RUNS IN EXCESS OF 10 FT. SHALL BE PROVIDED WITH A PULL WIRE OR FISH TAPE / CORD. <br />20 ALL BRANCH CIRCUIT CONDUCTORS FROM THE PANEL TO THE FIRST OUTLET SHALL BE INCREASED TO THE NEXT <br />LARGER SIZE WHERE THE LENGTH OF THE HOME RUN EXCEEDS 100 FT. ON 120/208V CIRCUITS. <br />21 CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER SIZING OF ALL MOTOR OVERLOAD DEVICES (HEATERS) IN <br />STARTERS BASED ON ACTUAL NAMEPLATE RATINGS ON THE MOTORS BEING INSTALLED. <br />22 CONTRACTOR SHALL NOTE U.L. LABELS ON PACKAGE TYPE MECHANICAL EQUIPMENT. IF U.L. LABEL ON MECHANICAL <br />EQUIPMENT CALLS FOR THE OVERCURRENT PROTECTIVE DEVICE TO BE FUSES, THE ELECTRICAL CONTRACTOR SHALL <br />PROVIDE A FUSED DISCONNECT SWITCH WITH PROPER SIZE FUSES AT THE SWITCH LOCATION INDICATED ON DRAWINGS. <br />23 CONTRACTOR SHALL VERIFY WIRE SIZES, C/B AND FUSE RATINGS FOR ALL HVAC EQUIPMENT, AND BRING TO THE <br />ATTENTION OF THE ARCHITECT AND / OR THE ENGINEER ANY DISCREPANCIES AFFECTING THE WORK PRIOR TO <br />PROCEEDING. <br />24 HORSEPOWER RATINGS INDICATED ON DRAWING MAY DIFFER FROM ACTUAL EQUIPMENT FURNISHED. IF FURNISHED <br />EQUIPMENT DIFFERS FROM RATINGS ON DRAWINGS, CONTRACTOR SHALL NOTIFY ARCHITECT AND / OR THE ENGINEER <br />FOR APPROPRIATE ACTION TO BE TAKEN. <br />25 PROVIDE APPROVED "HACR" TYPE CIRCUIT BREAKERS FOR ALL HEATING, AIR CONDITIONING, AND REFRIGERATION <br />EQUIPMENT INDICATED FOR CONNECTION ON ELECTRICAL DRAWINGS. <br />26 ALL DEVICES AND COVER PLATES SHALL BE CONSTRUCTED OF MOLDED NYLON MATERIALS. COLOR OF DEVICES AND <br />MATCHING COVER PLATES SHALL BE AS SELECTED BY THE ARCHITECT. <br />27 THE CONTRACTOR SHALL GUARANTEE ALL HIS WORK AND MATERIALS FOR A PERIOD OF ONE YEAR AFTER ACCEPTANCE <br />BY OWNER. <br />28 IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO COORDINATE SERVICE REQUIREMENTS FOR <br />POWER AND TELEPHONE UTILITIES. <br />29 PROVIDE A #10 NEUTRAL CONDUCTOR FOR ALL MULTIWIRE RECEPTACLE BRANCH CIRCUITS. <br />30 FOR ALL EQUIPMENT RATED 100 AMPS OR LESS, E.C. SHALL PROVIDE TERMINATIONS WHICH ARE LISTED FOR USE AT <br />75 DEGREES C OR PROVIDE WIRING SIZED USING THE 60 DEGREE C AMPACITY. <br />31 RECEPTACLES ON SEPARATE CIRCUITS SHALL BE RATED 20 AMP, 120 VOLT. <br />32 WIRE AND CABLE SHALL BE COPPER, TYPE THHN/THWN, MINIMUM #12 AWG. <br />33 PANELBOARD DIRECTORIES SHALL BE UPDATED TO REFLECT ALL WORK DONE AS PART OF THIS PROJECT. <br />34 ALL NEW BRANCH CIRCUITS SHALL BE EQUIPPED WITH A MINIMUM #12 AWG GREEN EQUIPMENT GROUND CONDUCTOR. <br />35 CONDUIT RUN UNDERGROUND SHALL BE PVC SCHEDULE 40. ALL BUILDING WIRING SHALL BE RUN IN METALLIC <br />CONDUIT. INTERIOR CONDUIT SHALL BE EMT. EXTERIOR CONDUIT SHALL BE IMC OR RMC. <br />36 FOR IG RECEPTACLES, PROVIDE 2#12 GREEN GROUND WIRES IN BRANCH CIRCUIT BACK TO PANELBOARD. <br />37 — 49 NOT USED. <br />50 OPEN / CLOSED LANE SIGNS ARE CONTROLLED BY SWITCHES AT THE DRIVE / THRU TELLER LOCATION. THE ATM <br />SIGN STAYS ON CONTINUOUSLY. <br />51 SEE SWITCHING STATION DETAIL THIS SHEET. <br />52 4#12, 1/2"C TO LIGHTING TERMINAL BLOCK LTB. <br />53 LIGHTING TROUGH T-1 WITH LIGHTING CONTACTORS AND TIME CLOCK. SEE TROUGH T-1 DETAIL THIS SHEET. <br />54 LABEL SWITCH "LOBBY LIGHTING". PROVIDE 2#12, 1/2"C TO LIGHTING TERMINAL BLOCK LTB. <br />SPROVIDE J—BOX WITH BLANK COVER ABOVE THE HUNG CEILING (13'8" AFF) FOR CONNECTION TO SIGN BY OTHERS. <br />56 CONNECT BATTERY CHARGE CIRCUIT AHEAD OF SWITCHING. <br />57 MOUNT PHOTOCELL ON NORTH FACING PARAPET WALL. <br />58 PROVIDE CONNECTION TO SIGN. COORDINATE CONNECTION WITH SIGN SUPPLIER. <br />59 — S NOT USED. <br />70 FOR AHD POWER, MOUNT 70" AFF TO BOTTOM OF BOX. <br />71 PROVIDE CONNECTION (USE FLEXIBLE CONDUIT) TO MECHANICAL FAN (WITH PLUG—IN MOTOR USED AS DISCONNECT). <br />ROUTE POWER TO TIME CLOCK. <br />72 PROVIDE CONNECTION (USE FLEXIBLE CONDUIT) TO MECHANICAL FAN (WITH PLUG—IN MOTOR USED AS DISCONNECT). <br />ROUTE POWER THROUGH MECHANICAL WALL DEVICE (THERMOSTAT OR WALL TIMER). <br />73 MOUNT RECEPTACLES INSIDE CABINET. COORDINATE INSTALLATION WITH MILL WORK PROVIDER. <br />74 PROVIDE 4" SQUARE JUNCTION BOX ABOVE CEILING FOR EACH LANE. <br />75 PROVIDE CONNECTION TO DRIVE—THRU CUSTOMER UNIT. <br />76 MOUNT RECEPTACLES ON OWNER FURNISHED DATA RACK. COORDINATE LOCATION WITH OWNER. <br />77 OUTLETS TO BE MOUNTED HORIZONTALLY. COORDINATE OUTLET LOCATION WITH OWNER FURNISHED FLAT SCREEN TV <br />BRACKET. <br />78 3/4"C WITH RG-6 COAX CABLE TO SATELLITE CONTROLLER. PROVIDE 5' SLACK CABLE. <br />79 3/4"C WITH RG-6 COAX CABLE TO STB. PROVIDE 5' SLACK CABLE AT EACH END. <br />80 ALL COAX CABLE TERMINATIONS BY A/V SATELLITE EQUIPMENT INSTALLER. <br />81 PROVIDE CONNECTION (USE FLEXIBLE CONDUIT) TO MECHANICAL FAN (WITH PLUG—IN MOTOR USED AS DISCONNECT). <br />CONNECT TO LIGHTING CIRCUIT AHEAD OF _SWITCHING. ROUTE POWER THROUGH MECHANICAL WALL DEVICE <br />(THERMOSTAT OR WALL TIMER). <br />82 3" TELEPHONE SERVICE CONDUIT. SEE "MAIN TELEPHONE TERMINAL BOARD (MTB)" THIS DRAWING. <br />83 PROVIDE 6" SQ. JUNCTION BOX MOUNTED IN KNEE SPACE. <br />84 COORDINATE LOCATION WITH BANK. MOUNT ABOVE CANOPY CEILING. <br />85 PROVIDE 3/4" CONDUIT FOR VIDEO TO JUNCTION BOX AT TELLER WINDOW. <br />86 PROVIDE 3/4" CONDUIT FOR AUDIO AND CONTROL TO JB-1. Y <br />87 LOCATION OF SATELLITE DISH CONTROLLER INSIDE MILLWORK. <br />88 CONNECT TO VAULT VENTILATOR. <br />SCONNECT TO VAULT LIGHT CIRCUIT. MOUNT ABOVE VAULT DOOR. <br />90 MOUNT RECEPTACLE ABOVE CEILING FOR DYE PACK UNIT. <br />91 FOR IRRIGATION CONTROLLER, COORDINATE EXACT LOCATION WITH IRRIGATION CONTRACTOR. <br />92 PROVIDE DISCONNECT SWITCH AND MAKE CONNECTION TO ELECTRIC WATER HEATER UTILIZING LIQUIDTIGHT FLEXIBLE <br />L C N IT <br />93 PROVIDE FLUSH MOUNT JUNCTION BOX FOR POWER CONNECTION TO PREWIRED OFFICE FURNITURE. UTILIZE FLEXIBLE <br />CONDUIT. PROVIDE CONNECTION WITH 3 PHASE WIRES, 2 NEUTRALS AND 1 GROUND. COORDINATE WIRING <br />CONNECTION WITH OFFICE FURNITURE SUPPLIER PRIOR TO ROUGHING. REVERIFY WALL LOCATION FOR CONNECTION TO <br />OFFICE FURNITURE. <br />94 PROVIDE FLUSH MOUNT JUNCTION BOX FOR TELECOMMUNICATIONS CONNECTION TO PREWIRED OFFICE FURNITURE. <br />UTILIZE FLEXIBLE CONDUIT. COORDINATE CONNECTION WITH OFFICE FURNITURE SUPPLIER PRIOR TO ROUGHING. <br />REVERIFY WALL LOCATION FOR CONNECTION TO OFFICE FURNITURE. <br />95 PROVIDE CONNECTION TO ROOFTOP UNITS PACKAGED DISCONNECT USING LIQUIDTIGHT FLEXIBLE CONDUIT. ROUTE <br />CONDUIT WITHIN UNIT TO AVOID ROOF PENETRATION. <br />96 PROVIDE (2) 1" CONDUITS TO DATA RACK. <br />97 SURFACE MOUNT OUTLET. RUN SURFACE METAL RACEWAY VERTICALLY TO ABOVE CEILING. <br />98 SURFACE MOUNT OUTLET. RUN SURFACE METAL RACEWAY HORIZONTALLY TO CONDUIT UP IN WALL. <br />99 COORDINATE MOUNTING HEIGHT OF JUNCTION BOX WITH SURROUND. <br />00 CONDUIT TO ABOVE CEILING. <br />101 MOUNT OUTLET HORIZONTALLY. <br />10 MOUNT THIS RECEPTACLE AND TV OUTLET IN RECESSED ELECTRICAL BOX. LEVITON PRODUCT #4717—REB. <br />0� 2#12, 1#12 G, 1/2"C TO TIME CLOCK. <br />1 D 60" AFF TO CENTER OF BOX. <br />FAI <br />ELECTRICAL SYMBOL LEGEND <br />HOMERUN TO PANELBOARD. NUMBER OF ARROWS INDICATES NUMBER OF CIRCUITS. <br />CONDUIT RUN CONCEALED IN WALL OR ABOVE CEILING. <br />/ CONDUIT RUN CONCEALED IN OR BELOW FLOOR OR UNDERGROUND. <br />CONDUIT RUN EXPOSED <br />SERVICE OR EQUIPMENT GROUND. <br />❑ <br />JUNCTION BOX FLUSH MOUNTED UNLESS INDICATED OTHERWISE. <br />= <br />PANELBOARD (SURFACE MOUNTED). <br />° <br />TELEPHONE EQUIPMENT BACKBOARD, SEE TELEPHONE AND SATELLITE SCHEMATIC NOTES. <br />A <br />RECESSED FLUORESCENT LIGHTING FIXTURE. LETTER INDICATES TYPE. <br />DARKENED HALF IN ANY LIGHTING FIXTURE SYMBOL SHOWN HEREIN INDICATES <br />A <br />THAT FIXTURE SHALL CONTAIN A SELF—CONTAINED BATTERY PACK <br />DARKENED HALF IN ANY LIGHTING FIXTURE WITH NL SYMBOL SHOWN HEREIN INDICATES <br />Zid <br />THAT FIXTURE IS ON UNSWITCHED NIGHT LIGHTING SYSTEM, W/SELF— <br />CONTAINED BATTERY PACK AND INVERTER <br />O <br />CEILING MOUNTED INCANDESCENT OR FLUORESCENT OR HID FIXTURE. <br />® <br />CEILING MOUNTED EXIT LIGHT. SINGLE FACE, BLACKENED AREA REPRESENTS FACE. <br />WALL MOUNTED EXIT LIGHT. SINGLE FACE, BLACKENED AREA REPRESENTS FACE. <br />SINGLE POLE SWITCH IN FLUSH OUTLET BOX, 48 INCHES ABOVE FINISHED FLOOR, <br />UNLESS HEIGHT IS OTHERWISE NOTED ON PLAN. <br />3 <br />THREE—WAY SWITCH IN OUTLET BOX, 48 INCHES ABOVE FINISHED FLOOR. <br />WALL MOUNTED TYPE MOTION DETECTOR SWITCH IN FLUSH MOUNTED OUTLET BOX, <br />D1 <br />48" ABOVE FINISHED FLOOR. LITHONIA MODEL #LIRW MVOLT. <br />WALL MOUNTED TYPE MOTION DETECTOR SWITCH IN FLUSH MOUNTED OUTLET BOX, <br />D2 <br />48" ABOVE FINISHED FLOOR. LITHONIA MODEL #LIRW DS MVOLT. <br />T <br />TWIST TIMER, TORK #A506H <br />125—VOLT, 15A, 3 WIRE DUPLEX RECEPTACLE IN FLUSH OUTLET BOX, 18 INCHES ABOVE <br />FINISHED FLOOR. SEE GENERAL NOTE 31. <br />125—VOLT, 15A, 3 WIRE DOUBLE DUPLEX RECEPTACLE IN FLUSH OUTLET BOX, <br />18" ABOVE FINISHED FLOOR. SEE GENERAL NOTE 31. <br />125—VOLT, 15A, 3 WIRE DOUBLE DUPLEX RECEPTACLE IN FLUSH OUTLET BOX, 48 INCHES <br />ABOVE FINISHED FLOOR, 6 INCHES ABOVE DESK/COUNTERTOP, OR 2 INCHES ABOVE <br />COUNTERTOP BACKSPLASH AS REQUIRED BY CONDITION, OR AS NOTED. SEE GENERAL NOTE 31. <br />125—VOLT, 15A, 3 WIRE DUPLEX RECEPTACLE IN FLUSH OUTLET BOX, 48 INCHES <br />ABOVE FINISHED FLOOR, 6 INCHES ABOVE DESK/COUNTERTOP, OR 2 INCHES ABOVE <br />COUNTERTOP BACKSPLASH AS REQUIRED BY CONDITION, OR AS NOTED. SEE GENERAL NOTE 31. <br />EEC <br />125—VOLT, 30A, SIMPLEX RECEPTACLE IN FLUSH OUTLET BOX, COORDINATE MOUNTING. <br />SEE GENERAL NOTE 31. <br />125—VOLT, 15A, 3 WIRE GROUND FAULT INTERRUPTER TYPE DUPLEX RECEPTACLE IN <br />GFI <br />FLUSH OUTLET BOX, 18 INCHES ABOVE FINISHED FLOOR, OR AS NOTED. SEE GENERAL NOTE 31. <br />125—VOLT, 15A, 3 WIRE DUPLEX RECEPTACLE WITH STAINLESS STEEL WEATHERPROOF COVER, <br />WP <br />18 INCHES ABOVE FINISHED FLOOR, OR AS NOTED. SEE GENERAL NOTE 31. <br />125—VOLT, 15A, 3 WIRE ISOLATED GROUND TYPE RECEPTACLE IN <br />IG <br />FLUSH OUTLET BOX, 18 INCHES ABOVE FINISHED FLOOR, OR AS NOTED. SEE GENERAL NOTE 36. <br />125—VOLT, 15A, 3 WIRE ISOLATED GROUND TYPE RECEPTACLE IN FLUSH OUTLET BOX MOUNTED <br />EWC <br />UP IN EWC CABINET, 18 INCHES ABOVE FINISHED FLOOR, OR AS NOTED. SEE GENERAL NOTE 31.. <br />PROVIDE NEW WALKER RFB4 SERIES CAST IRON FLOOR BOX, FOR CONCRETE ON GRADE, <br />• <br />® <br />WITH S36BBT—CAL COVER PLATE. COORDINATE COLOR WITH OWNER. PROVIDE WITH TWO DUPLEX <br />N5-15R OUTLETS. STUB 1"EC FROM COMMUNICATIONS COMPARTMENTS TO ACCESSIBLE CEILING SPACE <br />OR AS INDICATED ON DRAWINGS. <br />FLUSH OUTLET BOX FOR WALL —MOUNTED TELEPHONE 48 INCHES ABOVE FINISHED <br />FLOOR, 6 INCHES ABOVE COUNTERTOP, OR AT HEIGHT INDICATED ON PLAN, WITH <br />3/4" CONDUIT TO 6" ABOVE ACCESSIBLE CEILING. <br />d <br />TELEPHONE/DATA OUTLET, 4" X 4" OUTLET BOX WITH A 1 GANG COVER WITH (1) 3/4" <br />CONDUIT TO 6" ABOVE ACCESSIBLE CEILING. DEVICE TO BE 18" AFF OR AS NOTED. <br />TELEPHONE/DATA OUTLET, 4" X 4" OUTLET BOX WITH A 1 GANG COVER WITH (1) 3/4" <br />CONDUIT TO 6" ABOVE ACCESSIBLE CEILING. DEVICE TO BE 48" AFF, 6" ABOVE <br />DESK/COUNTERTOP, OR 2" ABOVE COUNTERTOP BACKSPLASH AS REQUIRED BY CONDITION, <br />OR AS NOTED. <br />TV <br />FLUSH OUTLET BOX AND TELEVISION COVERPLATE 48 INCHES ABOVE FINISHED <br />FLOOR, 6 INCHES ABOVE COUNTERTOP, OR AT HEIGHT INDICATED ON PLAN, WITH <br />3/4" CONDUIT TO 6" ABOVE ACCESSIBLE CEILING. <br />0 <br />CONNECTION TO FRACTIONAL HORSEPOWER ELECTRIC MOTOR. <br />P <br />PHOTOELECTRIC CELL. MOUNT NORTH FACING ON PARAPET WALL. PROVIDE TORK #2101 <br />ILCI ELECTRICALLY HELD LIGHTING CONTACTOR. <br />FAI <br />S® <br />SURGE SUPPRESSOR <br />❑' <br />NON —FUSIBLE DISCONNECT SWITCH IN NEMA-1 ENCLOSURE. <br />PROVIDE NUMBER OF POLES AS REQUIRED, <br />VOLTAGE RATING AS REQUIRED. 3R INDICATES NEMA-3R ENCLOSURE. <br />FUSIBLE DISCONNECT SWITCH IN NEMA-1 ENCLOSURE. <br />PROVIDE NUMBER OF POLES AS REQUIRED, FUSE SIZE AS INDICATED, <br />VOLTAGE RATING AS REQUIRED. 3R INDICATES NEMA-3R ENCLOSURE. <br />O <br />SECURITY SYSTEM OUTLET. NUMERAL IDENTIFIES OUTLET. SEE SECURITY SYSTEM BOX LEGEND. <br />Ol <br />DRAWING NOTES SYMBOL <br />ASTB <br />ALARM SYSTEM TERMINAL BOARD <br />EC <br />EMPTY CONDUIT WITH PULLCORD <br />FPN <br />FUSE PER NAMEPLATE <br />GFI <br />GROUND FAULT INTERRUPTER <br />IG <br />ISOLATED GROUND <br />MTB <br />MAIN TELEPHONE TERMINAL BOARD <br />NF <br />NON —FUSED <br />NL <br />NIGHT LIGHTING <br />STB <br />SATELLITE TERMINAL BOARD <br />WP <br />WEATHERPROOF <br />NATIONAL SALES CONTRACT: ALL LIGHTING FIXTURES, PANELBOARDS, <br />DISCONNECT SWITCHES, CONTACTORS, AND SIMILAR EQUIPMENT SHALL <br />BE PURCHASED THROUGH WACHOVIA NATIONAL SALES CONTRACT. <br />CONTACT ERIC SWANN (704-587-4025/eric.swannOgexpro.com) OR <br />ERICA BRAWLEY (704-587-4018/Erica.Brawley®gexpro. com) AT <br />GEXPRO SUPPLY IN CHARLOTTE, NC FOR PRICING. <br />OWNER REVISIONS 07/17/09 <br />ARCHITECTURAL ENGINEERING INCORPORATED <br />3442 EAST LAKE ROAD, PALM HARBOR, FL 34685 <br />CONSULTING ENGINEERS (727) 784-1472 <br />CERTIFICATE OF AUTHORIZATION: FL 3886 <br />W. RONALD MCILVEEN FL PE 30270 <br />ELEMENTS State License #AA0002341 <br />PARCEL <br />US ROUTE 301 <br />ZEPHYRHILLS, FLORIDA <br />Droving No./Dote 02.055.0 <br />PROD NO. 0I--071 , 081: 26 <br />Drowin Titie/Scole/Drown by 'SEE <br />ELECTRICAL <br />LECEND,NOTES,SCHE.DU ._E.S <br />SCALE:I~ ONE <br />