My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7810 and 7850 Gall Blvd
Zephyrhills
>
Building Department
>
Building Plans
>
7810 and 7850 Gall Blvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 4:42:30 AM
Creation date
2/19/2025 11:48:39 AM
Metadata
Fields
Template:
Building Plans
Street #
7810 and 7850
Location
Gall Blvd
Contractor
Hawkins Construction
Building Plans - Permit #
8060 and 8061
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL LEGENDI <br />NOT ALL DEVICES SHOWN IN LEGEND ARE REQUIRED. <br />REVIEW <br />POWER & LIGHTING PLANS AND DETAILS <br />FOR ITEMS WHICH APPLY TO THIS PROJECT. <br />X <br />EXIT LIGHT (SHADE AREA INDICATES DIRECTION) LETTER INDICATES TYPE <br />SEE LIGHT FIXTURE SCHEDULE TO CONFIRM TYPE AND MOUNTING. <br />BATTERY POWERED EMERGENCY LIGHT <br />TELEPHONE WALL OUTLET, PROVIDE SINGLE GANG BOX WITH 3/4" <br />CONDUIT WITH PULL WIRE AND INSULATING BUSHING STUBBED INTO <br />CEILING SPACE. MOUNT BOX 18" A.F.F. U.O.N. <br />(�)c <br />DUPLEX RECEPTACLE, MOUNT 18" A.F.F. U.O.N. <br />DUPLEX RECEPTACLE MOUNTED ABOVE COUNTER HEIGHT U.O.N. <br />GROUND FAULT INTERRUPTER RECEPTACLE, LEVITON #6898-I, MOUNT <br />ABOVE COUNTER HEIGHT U.O.N. <br />I G. <br />DUPLEX RECEPTACLE, ISOLATED GROUND TYPE, LEVITON #5362-IGI <br />MOUNTED ABOVE COUNTER HEIGHT. U.O.N. <br />TAMPER -RESISTANT DUPLEX RECEPTACLE PASS&SEYMOUR (TR63-HW) <br />G. <br />DUPLEX RECEPTACLE, ISOLATED GROUND TYPE, LEVITON #5362-IGI <br />MOUNT AT 18" A.F.F. U.O.N. <br />WPG <br />DUPLEX RECEPTACLE, WEATHERPROOF GROUND FAULT INTERRUPTER <br />(�)z <br />TYPE, LEVITON, MOUNT AT 18" A.F.G., U.O.N. <br />DUPLEX RECEPTACLE, MOUNTED ABOVE STOREFRONT WINDOWS <br />QUADRIPLEX RECEPTACLE, MOUNT AT 18" A.F.F. U.O.N. <br />JQ <br />JUNCTION BOX (FLUSH MOUNT IN FINISHED AREAS U.O.N.) <br />LIGHTING, POWER, OR SYSTEMS PANELBOARDS. <br />MSB/MDP <br />MAIN SWITCHBOARD OR MAIN DISTRIBUTION PANEL <br />CONDUIT CONCEALED IN WALL, BELOW SLAB, OR ABOVE CEILING. <br />A-1,3 <br />CONDUIT RUN CONCEALED IN WALLS BELOW SLAB, OR CEILING SPACES. <br />ARROWS INDICATE HOMERUN. SMALL HASHMARKS INDICATE NUMBER OF <br />HOT CONDUCTORS, AND LARGE HASHMARK INDICATES NEUTRAL. <br />SUBSCRIPT INDICATES PANEL AND CIRCUIT NUMBERS. GROUND <br />CONDUCTOR REQUIRED IN ALL CONDUITS BUT NOT INDICATED. <br />A-37:39:41 <br />SUBSCRIPT INDICATES PANEL -AND NUMBERS WITH COLONS <br />INDICATE 2 OR 3 POLE CIRCUITS. <br />`o <br />DISCONNECT SWITCH <br />100/3/60 <br />DISCONNECT DESIGNATION (SIZE/POLES/FUSE) "NF" INDICATES <br />"DE" <br />NON -FUSED; INDICATES DUAL ELEMENT FUSES. <br />MOTOR PERMANENTLY CONNECTED WITH FLEXIBLE CONDUIT <br />EF <br />(HORSEPOWER OR EQUIPMENT INDICATED) <br />THERMOSTAT. PROVIDE SINGLE GANG BOX WITH 1/2" C. STUBBED <br />`D <br />INTO CEILING SPACE, MOUNT 60" A.F.F O.O.N. (COORDINATE WITH <br />MECHANICAL DRAWINGS PRIOR TO ROUGI -IN) <br />EEI <br />FIRE ALARM PULL SWITCH <br />FCC' <br />HORN/STROBE <br />OR�ZSMOKE DETECTOR: EDWARDS #ISIGA-PS <br />\.EF <br />BATH ROOM FAN LIGHT (BROAN S150L) <br />FIRE ALARM SPRINKLER TAMPER SWITCH <br />FIRE ALARM SPRINKLER FLOW SWITCH <br />OCCUPANCY SENSOR BY WATT STOPPER. <br />ABBREVIATIONS <br />EG <br />EQUIPMENT GROUND NL NIGHT LIGHT <br />IG <br />ISOLATED GROUND PC PULL CHAIN <br />WP <br />WEATHERPROOF C/T CURRENT TRANSFORMER <br />EC <br />EMPTY CONDUIT EX EXISTING DEVICE TO REMAIN <br />EWH <br />ELECTRIC WATER HEATER AFF ABOVE FINISH FLOOR <br />EWC <br />ELECTRIC WATER COOLER AFG ABOVE FINISH GRADE <br />E/F--EF <br />EXHAUST FAN U.O.N. UNLESS OTHERWISE NOTED <br />A/H-AHU <br />AIR HANDLING UNIT- N.T.S. NOT TO SCALE <br />ACC-CU <br />CONDENSING UNIT' NIC NOT IN CONTRACT <br />RTU <br />ROOF TOP UNIT TYP. TYPICAL <br />FACP <br />FIRE ALARM CONTROL PANEL VTC VIA TIME CLOCK <br />LB <br />LOCK BREAKER <br />GFI <br />GROUND FAULT INTERRUPTER <br />TTC <br />TELEPHONE TERMINAL CABINET <br />NOTE: MOUNTING HEIGHTS NOTED ARE TO BOTTOM OF DEVICE SHOWN. U.O.N. <br />ELECTRICAL PLAN NOTES: <br />O J-BOX FOR FUTURE TENANT SIGN. PROVIDE 3/4 " CONDUIT WITH PULL CORD TO REAR <br />OF SPACE AND STUB IN CEILING NEAR FUTURE PANEL LOCATION. COORD. LOCATION <br />OF J-BOX WITH ARCHITECTURAL. <br />O 1" CONDUIT WITH PULL CORD TO TELEPHONE TERMINAL CABINET. STUB -UP 2'-0" <br />A.F.F., CAP AND LABEL. <br />O3 TO SERVE NORTHERN -MOST SPACE VIA STUB -UPS (REF: NOTE 12). <br />O FACTORY INSTALLED POWERED CONVENIENCE OUTLET. INSTALLATION SHALL BE PER <br />SECTION 210.63 OF THE 2005 NEC. PROVIDE 3/4" CONDUIT WITH PULL -CORD TO REAR <br />OF SPACE AND STUB IN CEILING NEAR FUTURE PANEL LOCATION. COORDINATE WITH <br />MECHANICAL. <br />5O INSTALL TTC PER DETAIL (REF: E401 D-F). PROVIDE (2) 3" CONDUITS FROM <br />TELEPHONE COMPANY NETWORK TO THIS LOCATION. STUB -UP Z-0" CAP AND LABEL, <br />O6 PROVIDE 4" CONDUIT WITH PULL CORD FROM WIREWAY TO THIS LOCATION. STUB -UP <br />7-0" AFF CAP AND LABEL. <br />0KNOX BOX. FINAL LOCATION TO BE DETERMINED BY AHJ. <br />O TEMP CIRCUIT EMER & EXIT LIGHTS TO HOUSE PANEL. DURING TENANT <br />IMPROVEMENT, EMER & EXIT LIGHTS WILL BE RECIRCUITED TO CORRESPONDING <br />TENANT PANELS. <br />O9 INSTALL LIGHT FIXTURE AND STUB CONDUIT WITH PULL CORD INTO SPACE FOR <br />CONNECTION TO FUTURE TENANT PANEL. <br />10 TAMPER AND FLOW MONITORING FOR FIRE ALARM SYSTEM. (REF: E401D-F) <br />11 DISCONNECT FOR RTU. PROVIDE 1" CONDUIT WITH PULL -CORD TO REAR OF SPACE <br />AND STUB IN CEILING NEAR FUTURE PANEL LOCATION. FOR POWER REQUIREMENTS <br />TO RTU'S SEE MECHANICAL EQUIPMENT RISER DIAGRAM ON DRAWING E401DF. <br />CORRD. WITH MECHANICAL. <br />CONDUITS W"TH PULL -CORDS FROM WIREWAY TO THIS LOCATION. <br />STUB UP Z-0" A.F.F., CAP AND LABEL. <br />LIGHTING NOTES <br />1. VENDOR SHALL VERIFY ALL FIXTURE QUANTITIES. <br />2. VERIFY FIXTURE LOCATION, SEE REFLECTED CEILING PLAN. <br />3. VERIFY FIXTURE LOCATION PER THIS SHEET AND SHEET E002 ("SITE WIRING"), <br />WHICH DENOTES LOCATIONS OF EXTERNAL LIGHTS NOT SHOWN ON THIS SHEET. <br />4. MOUNTING HEIGHTS INDICATED ARE TO THE CENTER LINE OF DEVICE OR FIXTURE <br />UNLESS OTHERWISE NOTED. <br />5. NOT USED. <br />6. ALL FIXTURES TO BE PROVIDED BY, RECEIVED, STORED & INSTALLED BY <br />ELECTRICAL CONTRACTOR. <br />7. ELECTRICAL CONTRACTOR SHALL SUPPLY 10% ADDITIONAL SPARE OF ALL LAMP <br />TYPES TO BE LEFT AT JOB SITE AT END OF JOB. <br />Electrical Plan <br />1 Scale 1I8"=V-0" <br />REAR <br />LEFT RIGHT <br />N <br />FRONT <br />2 2 / X 2 TYP. <br />EM X- <br />LIGHT FIXTURE SCHEDULE <br />TYPE <br />SYMBOL <br />MANUFACTURER <br />CATALOG NO. <br />VOLT <br />LAMPS <br />MOUNTING <br />A <br />THOMAS <br />SL9421-7 <br />120 <br />(1) 60 W INCAND CLEAR GLASS <br />WALL MOUNTIFROSTED GLASS <br />B <br />DAYBRITE <br />WB232-CP-UNV-EB10R <br />120 <br />(2) 32 W T8 <br />WALL MOUNT <br />C <br />�❑ <br />CAPRI <br />CMQlOH70 <br />120 <br />(1) 70 W MH <br />RECESSED <br />D <br />2 <br />NITE BRITES <br />WCR-050-M-MT <br />120 <br />(1) 50 W <br />WALL MOUNT <br />EM <br />BEGHILLI <br />XLP-SI <br />120 <br />(INCLUDED) <br />WALL @ 8'-0" A.F.F. <br />X <br />® <br />BEGHILLI <br />VA4R-SA <br />120 <br />LED (INCLUDED) <br />UNIVERSAL <br />ALTERNATE FIXTURES SHALL BE BY "COOPER INDUSTRY", "LITHONIA", <br />"GENLYTE", "HUBBELL" AND "THOMAS INDUSTRY". ALL FIXTURE <br />SUBSTITUTIONS MUST BE SUBMITTED FOR APPROVAL (SEE SPECIFICATIONS). <br />GENERAL NOTES: <br />1. ALL FLUORESCENT LIGHTING FIXTURES SHALL HAVE <br />4. ALL EMERGENCY, EXIT AND NIGHT LIGHT FIXTURES SHALL BE <br />ENERGY SAVING LAMPS AND ELECTRONIC BALLASTS. <br />CONNECTED AHEAD OF LOCAL SWITCHES. UNLESS <br />OTHERWISE NOTED. <br />2. PROVIDE NECESSARY MOUNTING HARDWARE AND <br />5. ALL ALTERNATE FIXTURES SHALL BE SUBMITTED FOR PRIOR <br />ACCESSORIES FOR ALL FIXTURES. <br />APPROVAL, SEE SPECIFICATIONS. <br />3. PROVIDE .125 MIN. THICK LENSES FOR FLUORESCENT <br />FIXTURES. <br />V pub <br />CITY <br />IN- <br />1 <br />i <br />A <br />-HPF1-3 <br />VIA LTG <br />CONT. <br />� U <br />r0 <br />0 <br />U <br />C <br />W <br />C <br />0 <br />O <br />C: 00 <br />Cua) <br />UCo <br />M <br />•^�, V M C <br />W Cc--� '� <br />LU <br />Eca Co <br />� <br />z <br />�L > <br />a)w <br />z <br />MI—U) <br />U <br />C <br />0 <br />0 <br />co <br />CD <br />A -A <br />C) <br />1jL_ <br />06 <br />LIL <br />Lu <br />U) Cz (� I <br />z>`%0' <br />w�U)acvn <br />o <br />mYN0- <br />L <br />1 <br />i <br />LL <br />�i <br />I <br />Co <br />I <br />E. <br />r W <br />J <br />W <br />w <br />w <br />U) <br />Q <br />Z CN <br />Z <br />g <br />U) <br />m <br />z <br />9 <br />m <br />M. <br />U) <br />a <br />x <br />m <br />U) <br />Of <br />U <br />Lu <br />w <br />z <br />Z) <br />ai <br />w <br />al <br />of <br />w <br />Q <br />w <br />0 <br />Cl) <br />O <br />O <br />00 <br />0 <br />I- <br />O <br />O <br />00 <br />0 <br />CV <br />CV <br />V <br />O <br />J <br />w <br />o <br />z <br />rn <br />o <br />W <br />Co <br />w <br />M <br />O <br />Z <br />cn <br />Uuj <br />E?01F <br />
The URL can be used to link to this page
Your browser does not support the video tag.