7810 and 7850 Gall Blvd
Zephyrhills
>
Building Department
>
Building Plans
>
7810 and 7850 Gall Blvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 4:42:30 AM
Creation date
2/19/2025 11:48:39 AM
Metadata
Fields
Template:
Building Plans
Street #
7810 and 7850
Location
Gall Blvd
Contractor
Hawkins Construction
Building Plans - Permit #
8060 and 8061
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL LEGEND <br />NOT ALL DEVICES SHOWN IN LEGEND ARE REQUIRED. <br />REVIEW POWER & LIGHTING PLANS AND DETAILS <br />FOR ITEMS WHICH APPLY TO THIS PROJECT. <br />X <br />EXIT LIGHT (SHADE AREA INDICATES DIRECTION) LETTER INDICATES TYPE <br />SEE LIGHT FIXTURE SCHEDULE TO CONFIRM TYPE AND MOUNTING. <br />BATTERY POWERED EMERGENCY LIGHT <br />TELEPHONE WALL OUTLET, PROVIDE SINGLE GANG BOX WITH 3/4" <br />♦ <br />CONDUIT WITH PULL WIRE AND INSULATING BUSHING STUBBED INTO <br />CEILING SPACE. MOUNT BOX 18" A.F.F. U.O.N. <br />(�X: <br />DUPLEX RECEPTACLE, MOUNT 18" A.F.F. U.O.N. <br />@ <br />DUPLEX RECEPTACLE MOUNTED ABOVE COUNTER HEIGHT U.O.N. <br />cm <br />GROUND FAULT INTERRUPTER RECEPTACLE, LEVITON #6898-I, MOUNT <br />ABOVE COUNTER HEIGHT U.O.N. <br />I.G. <br />DUPLEX RECEPTACLE, ISOLATED GROUND TYPE, LEVITON #5362-IGI <br />MOUNTED ABOVE COUNTER HEIGHT. U.O.N. <br />TAMPER -RESISTANT DUPLEX RECEPTACLE PASS&SEYMOUR (TR63-HW) <br />i.G. <br />DUPLEX RECEPTACLE, ISOLATED GROUND TYPE, LEVITON #5362-IGI <br />MOUNT AT 18" A.F.F. U.O.N. <br />wPG <br />DUPLEX RECEPTACLE, WEATHERPROOF GROUND FAULT INTERRUPTER <br />TYPE, LEVITON, MOUNT AT 18" A.F.G., U.O.N. <br />$ <br />DUPLEX RECEPTACLE, MOUNTED ABOVE STOREFRONT WINDOWS <br />0-- <br />QUADRIPLEX RECEPTACLE, MOUNT AT 18" A.F.F. U.O.N. <br />JUNCTION BOX (FLUSH MOUNT IN FINISHED AREAS U.O.N.) <br />LIGHTING, POWER, OR SYSTEMS PANELBOARDS. <br />MSB/MDP <br />MAIN SWITCHBOARD OR MAIN DISTRIBUTION PANEL <br />CONDUIT CONCEALED IN WALL, BELOW SLAB, OR ABOVE CEILING. <br />A-1,3 <br />CONDUIT RUN CONCEALED IN WALLS BELOW SLAB, OR CEILING SPACES. <br />ARROWS INDICATE HOMERUN. SMALL HASHMARKS INDICATE NUMBER OF <br />HOT CONDUCTORS, AND LARGE HASHMARK INDICATES NEUTRAL. <br />SUBSCRIPT INDICATES PANEL AND CIRCUIT NUMBERS. GROUND <br />CONDUCTOR REQUIRED IN ALL CONDUITS BUT NOT INDICATED. <br />A-37:39:41 <br />SUBSCRIPT INDICATES PANEL -AND NUMBERS WITH COLONS <br />INDICATE 2 OR 3 POLE CIRCUITS. <br />Lo <br />DISCONNECT SWITCH <br />100/3/60 <br />DISCONNECT DESIGNATION (SIZE/POLES/FUSE) "NF" INDICATES <br />"DE" <br />NON -FUSED; D3CATFS DUz,L ELEMENT FUSES. <br />EF <br />MOTOR PERMANENTLY CONNECTED WITH FLEXIBLE CONDUIT <br />(HORSEPOWER OR EQUIPMENT INDICATED) <br />THERMOSTAT. PROVIDE SINGLE GANG BOX WITH 1/2" C. STUBBED <br />TD <br />INTO CEILING SPACE, MOUNT 60" A.F.F. U.O.N. (COORDINATE WITH <br />MECHANICAL DRAWINGS PRIOR TO ROUGH -IN) <br />❑F <br />FIRE ALARM PULL SWITCH <br />FD <br />HORN/STROBE <br />2O OR Z SMOKE DETECTOR: EDWARDS #ISIGA-PS <br />\&EF <br />BATH ROOM FAN LIGHT (BROAN S150L) <br />x� <br />FIRE ALARM SPRINKLER TAMPER SWITCH <br />FIRE ALARM SPRINKLER FLOW SWITCH <br />® <br />OCCUPANCY SENSOR BY WATT STOPPER. <br />ABBREVIATIONS <br />EG <br />EQUIPMENT GROUND NIL NIGHT LIGHT <br />IG <br />ISOLATED GROUND PC PULL CHAIN <br />WP <br />WEATHERPROOF C/T CURRENT TRANSFORMER <br />EC <br />EMPTY CONDUIT EX EXISTING DEVICE TO REMAIN <br />EWH <br />ELECTRIC WATER HEATER AFF ABOVE FINISH FLOOR <br />EWC <br />ELECTRIC WATER COOLER AFG ABOVE FINISH GRADE <br />E/F—EF <br />EXHAUST FAN U.O.N. UNLESS OTHERWISE NOTED <br />A/H—AHU <br />AIR HANDLING UNIT N.T.S. NOT TO SCALE <br />ACC—CU <br />CONDENSING UNIT NIC NOT IN CONTRACT <br />RTU <br />ROOF TOP UNIT TYP. TYPICAL <br />FRCP <br />FIRE ALARM CONTROL PANEL VTC VIA TIME CLOCK <br />LB <br />LOCK BREAKER <br />GFI <br />GROUND FAULT INTERRUPTER <br />TTC <br />TELEPHONE TERMINAL CABINET <br />NOTE: MOUNTING HEIGHTS NOTED ARE TO BOTTOM OF DEVICE SHOWN. U.O.N. <br />ELECTRICAL PLAN NOTES: <br />O J-BOX FOR FUTURE TENANT SIGN. PROVIDE 3/4 " CONDUIT WITH PULL CORD TO REAR <br />OF SPACE AND STUB IN CEILING NEAR FUTURE PANEL LOCATION. CORRD. LOCATION <br />OF J-BOX WITH ARCHITECTURAL. <br />O2 1" CONDUIT WITH PULL CORD TO TELEPHONE TERMINAL CABINET. STUB -UP 2'-0" <br />A.F.F., CAP AND LABEL. <br />O3 TO SERVE SOUTHERN -MOST SPACE VIA STUB -UPS (REF: NOTE 12). <br />O FACTORY INSTALLED POWERED CONVENIENCE OUTLET. INSTALLATION SHALL BE PER <br />SECTION 210.63 OF THE 2005 NEC. PROVIDE 3/4" CONDUIT WITH PULL -CORD TO REAR <br />OF SPACE AND STUB IN CEILING NEAR FUTURE PANEL LOCATION. COORDINATE WITH <br />MECHANICAL. <br />O INSTALL TTC PER DETAIL (REF: E401D-F). PROVIDE (2) 3" CONDUITS FROM <br />TELEPHONE COMPANY NETWORK TO THIS LOCATION. STUB -UP 2'-0" CAP AND LABEL. <br />O PROVIDE 4" CONDUIT WITH PULL CORD FROM WIREWAY TO THIS LOCATION. STUB -UP <br />7-0" AFF CAP AND LABEL. <br />O7 KNOX BOX. FINAL LOCATION TO BE DETERMINED BYAHJ. <br />O8 TEMP CIRCUIT EMER & EXIT LIGHTS TO HOUSE PANEL. DURING TENANT <br />IMPROVEMENT, EMER & EXIT LIGHTS WILL BE RECIRCUITED TO CORRESPONDING <br />TENANT PANELS. <br />O9 INSTALL LIGHT FIXTURE AND STUB CONDUIT WITH PULL CORD INTO SPACE FOR <br />CONNECTION TO FUTURE TENANT PANEL. <br />10 TAMPER AND FLOW MONITORING FOR FIRE ALARM SYSTEM. (REF: E401D-F) <br />11 DISCONNECT FOR RTU. PROVIDE V CONDUIT WITH PULL -CORD TO REAR OF SPACE <br />AND STUB IN CEILING NEAR FUTURE PANEL LOCATION. FOR POWER REQUIREMENTS <br />TO RTU'S SEE MECHANICAL EQUIPMENT RISER DIAGRAM ON DRAWING E401DF. <br />COORD. WITH MECHANICAL. <br />12 PROVIDE TWO 4" CONDUITS WITH PULL -CORDS FROM WIREWAY TO THIS LOCATION. <br />STUB UP 2'-0" A.F.F., CAP AND LABEL. <br />LIGHTING NOTES <br />1. VENDOR SHALL VERIFY ALL FIXTURE QUANTITIES. <br />2. VERIFY FIXTURE LOCATION, SEE REFLECTED CEILING PLAN. <br />3. NOT USED. <br />4. MOUNTING HEIGHTS INDICATED ARE TO THE CEf TER LINE Cr i7EVICE OR FIXTURE <br />UNLESS OTHERWISE NOTED. <br />5. NOT USED. <br />6. ALL FIXTURES TO BE PROVIDED BY, RECEIVED, STORED & INSTALLED BY <br />ELECTRICAL CONTRACTOR. <br />7. ELECTRICAL CONTRACTOR SHALL SUPPLY 10% ADDITIONAL SPARE OF ALL LAMP <br />TYPES TO BE LEFT AT JOB SITE AT END OF JOB. <br />ELECTRICAL PLAN <br />Scale 1/8"=1'-0" <br />REAR <br />LEFT FN' RIGHT <br />FRONT <br />LIGHT FIXTURE SCHEDULE <br />SYMBOL <br />MANUFACTURER <br />CATALOG NO. <br />VOLT <br />LAMPS <br />MOUNTING <br />IB <br />THOMAS <br />SL9421-7 <br />120 <br />(1) 60 W INCAND CLEAR GLASS <br />WALL MOUNT/FROSTED GLASS <br />® <br />DAYBRITE <br />WB232-CP-UNV-EB10R <br />120 <br />(2) 32 W T8 <br />WALL MOUNT <br />C <br />CAPRI <br />CMQ10H70V1-S56P <br />120 <br />(1) 70 W MH <br />RECESSED <br />D <br />Q <br />NITE BRITES <br />WCR-050-M-MT <br />120 <br />(1) 50 W <br />WALL MOUNT <br />EM <br />BEGHILLI <br />XLP-SI <br />120 <br />(INCLUDED) <br />WALL t7a F-0" A.F.F. <br />X <br />C� <br />BEGHILLI <br />VA4R-SA <br />120 <br />LED (INCLUDED) <br />UNIVERSAL <br />ALTERNATE FIXTURES SHALL BE BY "COOPER INDUSTRY", "LITHDNIA", <br />— <br />"GENLYTE", "HUBBELL" AND "THOMAS INDUSTRY". ALL FIXTURE <br />SUBSTITUTIONS MUST BE SUBMITTED FOR APPROVAL (SEE SPECIFICATIONS). <br />GENERAL NOTES: <br />1. ALL FLUORESCENT LIGHTING FIXTURES SHALL HAVE <br />4. <br />ALL EMERGENCY, EXIT AND NIGHT LIGHT FIXTURES SHALL BE <br />ENERGY SAVING LAMPS AND ELECTRONIC BALLASTS. <br />CONNECTED AHEAD OF LOCAL SWITCHES. UNLESS <br />OTHERWISE NOTED. <br />2. PROVIDE NECESSARY MOUNTING HARDWARE AND <br />5. <br />ALL ALTERNATE FIXTURES SHALL BE SUBMITTED FOR PRIOR <br />ACCESSORIES FOR ALL FIXTURES. <br />APPROVAL, SEE SPECIFICATIONS. <br />3. PROVIDE. 125 MIN. THICK LENSES FOR FLUORESCENT <br />FIXTURES. <br />irrtiEjs�i.' 3ElW .lyJlE <br />Ci�1y . 5n-10LI)ING 0FYI 1 kL—P( <br />Co <br />—US HWY 301 KEY PLAN <br />:N' <br />RE L RETAIL <br />F <br />m <br />IN <br />0 o <br />o <br />0 <br />0 <br />G <br />F <br />•� <br />o <br />0 <br />do0 <br />w <br />`V U <br />o I <br />� � U <br />�-,t 3 <br />U <br />u <br />U - <br />r� <br />V <br />(� 00 <br />c <br />U_3( <br />—CoCo <br />W J '� <br />w <br />cc <br />E 2 d LL <br />w <br />n CD to <br />J <br />�+MHU) <br />U <br />Cn <br />C <br />0 <br />E <br />E <br />0 <br />L <br />Cu <br />fI <br />06 <br />® U) c <br />LU <br />0 <br />w�co <br />o <br />mYN0- <br />Of <br />Q <br />.. <br />I <br />ZZ <br />0 <br />��0 <br />m <br />i <br />= <br />- <br />- <br />� <br />U) <br />J <br />N <br />U <br />ILL, <br />= <br />z <br />a_ <br />d <br />0 <br />- <br />w <br />^I <br />0 <br />O <br />C5 <br />Co <br />0 <br />O <br />O <br />�I <br />0 <br />N <br />uj <br />I <br />d <br />Z� <br />o <br />o <br />- <br />U <br />CoZ <br />w <br />cn <br />3 <br />N <br />w <br />o <br />LJL <br />U <br />R <br />Q <br />S <br />E1101D <br />