Laserfiche WebLink
MOUNT CAP LEVEL <br />ANCHOR W/ <br />CADMIUM PLATED <br />SCREWS 12" O.C. <br />FLASHING <br />BY ROOFER <br />1 1/2" EXTERNAL <br />INSULATION <br />SEAL WATERTIG­ <br />2Gravity Roof Vent Detail <br />Scale: None <br />BIRD SCREEN <br />ni Inni v n! !nT OMLI u! r11-ruIn <br />ROUND METAL DUCT - <br />(EXTERNAL INSULATION) <br />CEILING <br />CAULKING BEAD OR <br />GASKET FULL PERIMETER <br />0.25 D (4" MIN. <br />OF CURB BY HVAC. <br />PER SMACNA) <br />MAX. 200 TRANSITION <br />TREATED WOOD NAILER <br />RECTANGULAR <br />13-1/2" PREFABRICATED <br />r. <br />DUCT <br />CURB FURNISHED & <br />INSTALLED BY CONTRACTOR <br />LO <br />ROOF <br />CONICAL FITTING WITH <br />SUPPORT ANGLES AS <br />LOCKING TYPE VOLUME <br />VOLUME <br />REQUIRED BY GENERAL <br />DAMPER. <br />DAMPER <br />CONTRACTOR <br />FLEX DUCT OR ROUND SHEET METAL <br />DUCT. FLEX DUCT MAX. 8'-0" LONG, <br />USE CLAMP TO ATTACH FLEX DUCTS <br />2" <br />AND SEAL. SUPPORT DUCT EVERY <br />FOUR FEET FROM STRUCTURE <br />4 Ceiling Diffuser Runout Detail <br />Scale: None <br />NOTE: <br />HANGER STRAP <br />SIZE PER SMACNA. <br />-MIN. BAND OF SAME SIZE J <br />AS HANGER STRAP -/ <br />vvr��rry <br />Rectangular/Round Duct Hanger Detail <br />6 <br />INSULATED ROUND <br />FLEXIBLE DUCT <br />(MAX. V-0" LONG) <br />SIZE TO MATCH <br />DIFFUSER NECK. <br />INSULATION <br />DIFFUSER <br />STRAP <br />EXISTING SUPPLY & <br />RETURN DUCTWORK, <br />DIFFUSERS, AND <br />GRILLES, TO REMAIN. <br />SHIFT DISTRIBUTION <br />SYSTEM AS NEEDED TO <br />MATCH REVISED CEILING <br />LAYOUT. <br />1 Mechanical Floor Plan <br />SCALE: 1/8" = V-0" <br />1 `0 <br />12` a <br />d <br />I iA f <br />170 RTU D3 <br />r EXISTING 5 <br />I TON RTU TO <br />��4rs REMAIN. <br />• -..0 <br />TENANT SPACE D3 -1,400 SF <br />3 Branch Duct Detail <br />Scale: None <br />4'-0" MAXIMUM <br />MAXIMUM SAG 1/2" PER FOOT - <br />OF SUPPORT SPACING. i <br />FLEXIBLE DUCT <br />NOTES: <br />1. DUCT SHOULD EXTEND STRAIGHT FOR <br />SEVERAL INCHES FROM A CONNECTION <br />BEFORE BENDING. <br />2. SUPPORT SYSTEM MUST NOT DAMAGE DUCT <br />OR CAUSE OUT OF ROUND SHAPE. <br />5 Flex Duct Support Detail <br />Scale: None <br />EXISTING EXHAUST <br />is <br />SYSTEM IN EXISTING <br />RESTROOMS TO REMAIN. <br />VERIFY EXISTING <br />UNDERCUTS AFTER NEW <br />FINISHES ARE <br />I <br />INSTALLED. REMOVE, <br />O <br />RE -CUT, AND RE -INSTALL <br />DOORS IF NECESSARY. <br />!_ i " `4 <br />(IYPCF ) <br />5 <br />=mm=- <br />1 s <br />`- SD <br />t <br />I _ <br />C' RTU D4 <br />r - EXISTING 5 <br />r�. `F_'�' TON RTU TO <br />REMAIN. <br />TENANT SPACE D4 -1,400 SF <br />EXISTING SUPPLY & <br />RETURN DUCTWORK, <br />DIFFUSERS, AND <br />GRILLES, TO REMAIN. <br />SHIFT DISTRIBUTION <br />SYSTEM AS NEEDED TO <br />MATCH REVISED CEILING <br />LAYOUT. <br />Mechanical General Notes <br />1. CONTRACTOR TO VISIT SITE AND VERIFY ALL CLEARANCES BEFORE FABRICATION OF DUCTWORK AND PROVIDE ADDITIONAL <br />16. VERIFY VOLTAGE WITH ELECTRICAL CONTRACTOR BEFORE ORDERING EQUIPMENT. <br />OFFSET AND/OR CHANGES IN DUCT SIZES TO MEET FIELD CONDITIONS AND COORDINATE WITH ELECTRICAL, PLUMBING AND FIRE <br />PROTECTION SUBCONTRACTOR BEFORE ANY CONSTRUCTION WORK. <br />17. VERIFY EXISTING TRAP IN ALL CONDENSATE PIPING LOCATED AT AIR HANDLING UNITS. SLOPE CONDENSATE LINES 1/8" PER <br />FOOT. CONDENSATE LINES SHALL BE PVC SCH. 40. ALL CONDENSATE DRAIN PIPING SHALL BE PROPERLY SUPPORTED. <br />2. SUPPLY, RETURN AND OUTSIDE AIR DUCTWORK SHALL BE EXTERNALLY INSULATED SHEET METAL CONSTRUCTION IN <br />ACCORDANCE WITH LATEST SMACNA STANDARDS. INSULATION SHALL HAVE VAPOR BARRIER AND AN INSTALLED MINIMUM THERMAL <br />18. ALL MECHANICAL WORK SHALL MEET ALL THE REQUIREMENTS OF THE 2007 FLORIDA BUILDING CODE, MECHANICAL AND 2009 <br />RESISTANCE (R) VALUE OF 6.0. ALL EXHAUST DUCTWORK SHALL BE UNINSULATED SHEET METAL CONSTRUCTION IN ACCORDANCE <br />SUPPLEMENT. <br />WITH LATEST SMACNA STANDARDS. ALL JOINTS SHALL BE SECURELY TAPED WITH 3" WIDE GLASS FABRIC TAPE WITH FOSTER 30/35 <br />MASTIC OR EQUAL. <br />19. GUARANTEE; FOR ONE YEAR AFTER DATE OF ACCEPTANCE BY THE OWNER, ALL EQUIPMENT, MATERIALS AND WORKMANSHIP <br />TO BE FREE FROM DEFECT. <br />3. DUCT SHALL BE SECURELY SUPPORTED, HUNG OR SUSPENDED IN ACCORDANCE WITH THE LATEST SMACNA EDITION AND <br />SECTION 603 OF THE 2007 FLORIDA BUILDING CODE, MECHANICAL WITH 2O09 SUPPLEMENT. <br />20. DO NOT CUT STRUCTURAL MEMBERS WITHOUT PRIOR WRITTEN APPROVAL OF THE STRUCTURAL ENGINEER OR ARCHITECT. <br />ARRANGE FOR REPAIRS REQUIRED TO RESTORE OTHER WORK, BECAUSE OF DAMAGE CAUSED AS A RESULT OF MECHANICAL <br />4. ROOFTOP UNIT OUTSIDE AIR INTAKE SHALL MAINTAIN A MINIMUM OF 10'-0" FROM ANY EXHAUST OR SANITARY VENT THROUGH <br />INSTALLATIONS. <br />ROOF PIPING. ALL TRANSFER DUCTWORK LEADING TO REST ROOMS SHALL HAVE A ZERO LEAKAGE BACK DRAFT DAMPER AS SHOWN <br />ON MECHANICAL DRAWINGS. <br />21. FLEXIBLE AND RIGID ROUND DUCT TAKE -OFFS FOR DIFFUSERS SHALL BE THE SAME SIZE AS DIFFUSER NECK. MAXIMUM <br />FLEXIBLE DUCT LENGTH SHALL BE 8'-0". FLEXIBLE DUCT SHALL BE THERMAFLEX TYPE M-KC OR EQUAL.FLEXABLE DUCT SHALL BE <br />5. PROVIDE ALL MECHANICAL EQUIPMENT WITH MANUFACTURER'S RECOMMENDED SERVICE AREA CLEARANCES. <br />INSULATED FIBERGLASS, R-6, CLASS 1, UL181 LISTED AND COMPLY WITH NFPA 90A AND NFPA 90B. <br />6. ALL ROOF TOP UNITS SHALL BE REINFORCED TO WITHSTAND LOCAL WIND LOAD DESIGN. SEE STRUCTURAL DRAWING(S) FOR <br />22. ALL WALL MOUNTED THERMOSTATS SHALL BE INSTALLED AT AN ELEVATION OF 54" ABOVE FINISHED FLOOR TO THE TOP <br />DETAIL(S) /CONSULT WITH BUILDING STRUCTURAL ENGINEER. <br />UNLESS OTHERWISE NOTED ON DRAWINGS. LOCATION OF THE WALL MOUNTED THERMOSTAT SHALL BE COORDINATED WITH <br />OTHER TRADES FOR A NEAT APPEARANCE. FINAL LOCATION OF THERMOSTAT SHALL BE SUBJECT TO THE APPROVAL OF THE <br />7. DUCT SMOKE DETECTORS SHALL BE FURNISHED BY THE FIRE ALARM CONTRACTOR, INSTALLED INDUCT BY THE MECHANICAL <br />ENGINEER OR HIS REPRESENTATIVE IN THE FIELD. <br />CONTRACTOR AND WIRED BY THE FIRE ALARM CONTRACTOR. SMOKE DETECTORS SHALL BE INSTALLED IN ACCORDANCE WITH NFPA <br />72, NATIONAL FIRE ALARM CODE; NFPA 90A, STANDARD FOR INSTALLATION OF AIR-CONDITIONING AND VENTILATING SYSTEMS, 2007 <br />23. ALL UNITS SHALL BE BALANCED TO WITHIN 10 PERCENT OF THE DESIGN AIR QUANTITY. BALANCE DIFFUSERS AND <br />FLORIDA BUILDING CODE, MECHANICAL WITH 2O09 SUPPLEMENT AND THE MANUFACTURER'S INSTALLATION IN STRUCTIONS. <br />REGISTERS TO WITHIN 10 PERCENT OF QUANTITIES SHOWN ON DRAWINGS. <br />COORDINATE LOCATION OF SMOKE DETECTORS WITH FIRE ALARM CONTRACTOR. PROVIDE A VISIBLE/AUDIBLE NOTIFICATION PANEL. <br />MAKE: SYSTEM SENSOR SSK451 OR EQUAL, COMPATIBLE WITH BUILDING FIRE ALARM SYSTEM. <br />24. PROVIDE FLEXIBLE NEOPRENE DUCT CONNECTORS ON THE DISCHARGE AND ENTERING SIDES OF ALL VIBRATING EQUIPMENT <br />TO WHICH DUCTWORK IS ATTACHED. <br />8. IN GENERAL, PLANS AND DIAGRAMS ARE SCHEMATIC ONLY AND SHOULD NOT BE SCALED. <br />25. CONTRACTOR SHALL PROVIDE 3 COPIES OF A TEST AND BALANCE REPORT. AIR BALANCING SHALL BE PERFORMED BY AN <br />9. HVAC CONTRACTOR IS RESPONSIBLE FOR ANY ADDED ELECTRICAL COSTS WHICH MAY RESULT FROM SUBSTITUTED EQUIPMENT. <br />INDEPENDENT TESTING AND BALANCING CONTRACTOR WHICH SHALL BE QUALIFIED AND CERTIFIED BY EITHER ASSOCIATED AIR <br />BALANCE COUNCIL (AABC) OR NATIONAL ENVIRONMENTAL BALANCING BUREAU (NEBB). THIS REPORT MUST BE REVIEWED AND <br />10. DUCTWORK INSULATION SHALL BE FOIL FACED FIBERGLASS DUCT WRAP WITH A MINIMUM THERMAL RESISTANCE (R) OF 6.0. <br />APPROVED BY THE ENGINEER PRIOR TO THE FINAL INSPECTION. <br />INSULATION SHALL HAVE VAPOR BARRIER. INSTALL PER MFR. REQUIREMENTS. <br />26. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL TRADES' INSTALLATION SCHEDULES. COORDINATE WORK SCHEDULE <br />11. COORDINATE AIR DEVICE LOCATIONS WITH LIGHTING FIXTURES. <br />WITH GENERAL CONTRACTOR. <br />12. TURNING VANES SHALL BE PROVIDED IN ALL SUPPLY DUCT RECTANGULAR ELBOWS WITH ANGLES BETWEEN 15 DEGREES AND <br />27. WHEN THE INTENT OF THE DRAWINGS AND SPECIFICATIONS IS NOT CLEAR, OR IS CAPABLE OF MORE THAN ONE <br />LESS THAN 90 DEGREES PER FIG. 2-5 OF THE SMACNA MANUAL. <br />INTERPRETATION, SUCH MATTERS WILL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER IN WRITING BEFORE THE <br />SUBMISSION OF BIDS. THE ARCHITECTIENGINEER SHALL MAKE CORRECTION OR EXPLANATION IN WRITING. <br />13. DUCT DIMENSIONS SHOWN ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS. DUCTWORK, DIFFUSERS, REGISTERS, GRILLES, AND <br />OTHER ITEMS OF THE AIR HANDLING SYSTEM SHALL NOT BE SUPPORTED BY THE CEILING OR CEILING SUSPENSION SYSTEM. <br />28. PLANS AND SPECIFICATIONS ARE INTENDED AS A GENERAL DESCRIPTION OF THE WORK TO BE PERFORMED. ALL ITEMS NOT <br />SPECIFICALLY MENTIONED OR SHOWN, BUT NECESSARY FOR THE COMPLETION OF THE INSTALLATION, SHALL BE FURNISHED <br />14. UNLESS OTHERWISE NOTED, INSTALL DUCTWORK AS HIGH AS POSSIBLE, TIGHT TO BOTTOM OF STRUCTURE. COORDINATE DUCT <br />AND INSTALLED BY THIS CONTRACTOR. THIS CONTRACTOR SHALL THOROUGHLY ACQUAINT HIMSELF WITH THE MECHANICAL, <br />ELEVATION WITH STORM LEADERS, WATER PIPING, SANITARY DRAINS AND MAJOR ELECTRICAL CONDUITS. <br />ARCHITECTURAL, STRUCTURAL AND ELECTRICAL PLANS BEFORE SUBMITTING HIS FINAL BID. NO ADDITIONAL COMPENSATION <br />WILL BE ALLOWED DUE TO THE CONTRACTOR'S FAILURE TO FAMILIARIZE HIMSELF/ HERSELF WITH THE PLANS. <br />15. CONTRACTOR TO PROVIDE ALL SUPPLEMENTARY STEEL REQUIRED TO SUSPEND MECHANICAL EQUIPMENT & MATERIALS. <br />INSTALLATION OF EQUIPMENT SHALL COMPLY WITH MANUFACTURER'S SPECIFICATIONS AND CLEARANCE REQUIREMENTS FOR <br />SERVICING OF EQUIPMENT. <br />Scope Of Work Notes: <br />1. PRIOR TO SUBMITTING BIDS, CONTRACTOR SHALL <br />VISIT THE SITE TO VERIFY ALL EXISTING <br />CONDITIONS INCLUDING LOCATIONS OF ALL ROOF <br />PENETRATIONS OF ADJACENT TENANTS. <br />CONTRACTOR SHALL CONFIRM THAT THERE IS AT <br />LEAST 10' BETWEEN ANY NEW OR EXISTING <br />OUTSIDE AIR INTAKE AND ANY NEW OR EXISTING <br />EXHAUST OR VENT. IF THE CLEARANCES ARE <br />NOT AT LEAST 10', CONTRACTOR SHALL NOTIFY <br />THE ARCHITECT / ENGINEER IMMEDIATELY. <br />2. THE SCOPE COVERED IN THIS SET OF DRAWINGS <br />DOES NOT INCLUDE ANY WORK RELATED TO THE <br />EXISTING CONDENSATE SYSTEM. ALL EXISTING <br />CONDENSATE PIPING AND ROUTING SHALL <br />REMAIN AS IS. <br />3. THE DUCT ROUTING SHOWN ON THE PLAN IS <br />DIAGRAMMATIC. CONTRACTOR SHALL ROUTE <br />DUCTWORK SO AS TO MINIMIZE THE AMOUNT OF <br />MATERIAL USED. DUCT ROUTING SHALL BE <br />COORDINATED WITH ALL OTHER TRADES AND <br />ELEMENTS ABOVE THE CEILING. <br />4. CONTRACTOR SHALL TEST THE SYSTEM TO <br />CONFIRM THE EXISTING CFM VALUES ARE AS <br />SHOWN ON THE PLAN. IF THE EXISTING CFM <br />VALUES ARE NOT AS SHOWN, CONTRACTOR <br />SHALL RE -BALANCE THE SYSTEM. <br />Mechanical Key Plan Notes: <br />1� VERIFY THAT THERE IS AN EXISTING SMOKE <br />DUCT DETECTOR IN THE SUPPLY DUCT. IF THE <br />SMOKE DETECTOR 1S NOT INSTALLED, REFER <br />TO MECHANICAL GENERAL NOTE # 7. THE GC <br />SHALL BE RESPONSIBLE FOR COORDINATING <br />THE EXACT SCOPE OF WORK REQUIRED <br />BETWEEN THE MECHANICAL SUB AND THE <br />ELECTRICAL SUB PRIOR TO BIDDING. NO <br />CHANGE ORDERS WILL BE APPROVED FOR <br />FAILURE TO VERIFY EXISTING CONDITIONS OR <br />COORDINATE BETWEEN SUBS. <br />0 RELOCATE EXISTING THERMOSTAT FOR RTU D3 <br />TO THE LOCATION SHOWN. IF THERE IS NO <br />EXISTING THERMOSTAT, PROVIDE A NEW ONE. <br />O UNDERCUT DOOR 1" TO ALLOW FOR TRANSFER <br />OF AIR TO BATHROOM. <br />CEILING MOUNTED BATHROOM EXHAUST FAN. <br />COORDINATE EXACT LOCATION OF <br />PENETRATION WITH ARCHITECTURAL PLAN. <br />INSTALL GALVANIZED DUCT WORK DOWN FROM <br />GRAVITY ROOF VENT. SIZE OF DUCT TO MATCH <br />SIZE OF GRAVITY ROOF VENT OPENING. RUN <br />DUCT IN CEILING / JOIST SPACE AND CONNECT <br />TO CEILING MOUNTED EXHAUST FAN PER <br />MANUFACTURER'S RECOMMENDATIONS. <br />05 CONTRACTOR SHALL VERIFY THE LOCATION OF <br />THE EXISTING THERMOSTAT FOR RTU D4. IF <br />THE THERMOSTAT IS LOCATED ON AN EXISTING <br />WALL IN SPACE D4 THAT IS NOT BEING <br />REMOVED, IT SHALL REMAIN IN ITS EXISTING <br />LOCATION. IF IT IS LOCATED IN SPACE D3 OR IF <br />IT IS LOCATED ON A WALL THAT IS BEING <br />REMOVED, IT SHALL BE RELOCATED TO THE <br />LOCATION SHOWN. <br />Fan Schedule <br />EXT. STATIC <br />MARK <br />SERVICE <br />CFM <br />PRESSURE (IN. <br />FAN TYPE <br />DRIVE <br />SONES <br />WATTS <br />RPM <br />V/0 <br />MANUFACTURER <br />MODEL <br />NOTES <br />WATER) <br />EF-1 <br />EXHAUST <br />1100 <br />0.375 <br />CEILING <br />DIRECT <br />13.2 <br />198 <br />1100 <br />120/1 <br />1COOK <br />GC-144 <br />1,2 <br />NOTES: 1. WITH PLUG-IN DISCONNECT. <br />2. PROVIDE CONTROL BY MANUAL LIGHT WITH OCCUPANCY SENSOR. COORDINATE WITH ELECTRICAL DRAWINGS FOR LOCATION OF SWITCH. <br />HVAC Symbols <br />SYMBOL DESCRIPTION <br />OR DUCT WORK <br />FLEXIBLE DUCT <br />SUPPLY AIR DUCT WORK UP THRU PLAN <br />RETURN AIR OR EXHAUST <br />DUCT WORK UP THRU PLAN <br />" DUCT WORK TRANSITION <br />900 ELBOW WITH TURNING VANES <br />MANUAL AIR VOLUME CONTROL DAMPER <br />®0R® SUPPLY AIR DEVICE <br />RETURN AIR DEVICE <br />® EXHAUST AIR DEVICE <br />OT WALL MOUNTED THERMOSTAT <br />SD DUCT SMOKE DETECTOR <br />A-100 DIFFUSER DEVICE TYPE - AIR QUANTITY <br />RTU -10 EQUIPMENT DESIGNATION TAG <br />5-------- R-------- s REFRIGERATION PIPING <br />CONDENSATE PIPING <br />Outside Air Calculation <br />AREA <br />AREA <br />PEOPLE <br /># OF <br />CFM / <br />CFM / <br />CFM <br />CFM <br />SERVED <br />(SQFT) <br />11000 <br />PEOPLE <br />PERSON <br />SQFT (1) <br />REQUIRED <br />SUPPLIED <br />(SQFT) (1) <br />(1) <br />SPACE D3 <br />1,400 <br />- <br />- <br />0.3 <br />1 420 <br />420 <br />SPACE D4 <br />1,400 <br />- <br />- <br />- <br />0.3 <br />1 420 <br />420 <br />(1) PER TABLE 403.3 - FLORIDA BUILDING CODE - MECHANICAL 2007 <br />(2) VERIFY THE OUTSIDE AIR OF EACH EXISTING RTU IS 420 CFM. IF NOT, RE -BALANCE TO 420 CFM. <br />Gravity Roof Vent Schedule <br />THROAT <br />TYPE <br />CFM <br />SERVICE <br />MANUFACTURER <br />MODEL <br />NOTES <br />SIZE <br />GRV-1 <br />100 <br />EXHAUST <br />0.394 <br />COOK <br />PR 8 <br />1,2 <br />NOTES: <br />1. PROVIDE MANUFACTURER'S ROOF CURB. COORDINATE WITH ROOF TYPE. <br />2. PROVIDE INSECT SCREEN. <br />Air Device Schedule <br />TAG <br />MFG./CAT. # <br />TYPE <br />NECK <br />FRAME <br />FINISH <br />NOTES <br />0-125CFM = 6" RND <br />12x12 <br />130 -150 CFM = 6" RND <br />A <br />TITUS - TMS-AA <br />CD <br />160 - 275 CFM = 8" RND <br />BAK. WHT. ENAMEL <br />1,2,3,4,5 <br />280 - 390 CFM =10" RND <br />24 x 24 <br />400 - 600 CFM =12" RND <br />B <br />TITUS - 50F <br />RAR <br />22 x 22 (MAX 1280 CFM) <br />24 x 24 <br />BAK. WHT. ENAMEL <br />1,2,4,E <br />DEVICE TYPE LEGEND: CD = CEILING DIFFUSER <br />RAR = RETURN AIR REGISTER <br />NOTES: <br />1. PROVIDE CEILING DEVICES W/ PROPER FRAME STYLE TO MATCH CEILING TYPE CALLED FOR BY ARCHITECT. <br />2. DEVICES SHALL BE PROVIDED WITH FACTORY FINISH. <br />3. CEILING DIFFUSERS SHALL BE 4-WAY THROW UNLESS NOTED OTHERWISE OR SHOWN ON PLANS WITH <br />DIRECTIONAL ARROW(S). <br />4. IF NECESSARY, PROVIDE TOP HAT FOR GRILLES REGISTERS AND DIFFUSERS. <br />5. PROVIDE EQUALIZING GRID (TITUS MODEL EG). FOR DIFFUSERS TAPPED DIRECTLY FROM BOTTOM <br />OF DUCT, PROVIDE OPPOSED BLADE DAMPER (TITUS MODEL D-57). <br />6. PROVIDE OPPOSED BLADE DAMPER FOR REGISTERS. <br />Typ. Sequence of Operation <br />THE AIC UNIT SHALL BE STARTED AND STOPPED FROM A <br />ROOM THERMOSTAT. ON A CALL FOR COOLING, THE <br />THERMOSTAT SHALL ENERGIZE THE COMPRESSOR(S) TO <br />MAINTAIN SET POINT. ON A CALL FOR HEATING, THE <br />THERMOSTAT SHALL ENERGIZE THE ELECTRIC HEAT IN <br />STAGE(S) TO MAINTAIN SET POINT. SUPPLY FAN SHALL RUN <br />CONTINUOUSLY DURING OCCUPIED HOURS. <br />Drawing Index <br />SHEET # <br />TITLE <br />M101 <br />Mechanical Plan & General <br />Information <br />FBC Chapter 13 - Energy Efficiency <br />THIS BUILDING IS A PREVIOUSLY CONDITIONED SPACE THAT IS NOT UNDERGOING A CHANGE IN OCCUPANCY <br />OR A RENOVATION AS DEFINED BY SECTION 13-2 OF THE FBC. THEREFORE, PER FBC 13-101.5.1, COMPLIANCE <br />WITH THE ENERGY EFFICIENCY CODE IS NOT REQUIRED AND ENERGY CALCULATIONS ARE NOT REQUIRED. <br />0 <br />Ld <br />�a <br />00 <br />t <br />en <br />^�, <br />V/ 44 <br />w °� <br />U <br />�w <br />d c <br />U� <br />w <br />A <br />Cd�o <br />kn <br />N <br />V <br />W <br />C <br />0 <br />CL <br />0 <br />I` <br />0 II <br />W <br />CUZ� <br />UQM <br />^� M <br />• �/ 0 LL <br />Q .E�a <br />LNG <br />w � CY) <br />J <br />U <br />0 <br />E <br />E <br />0 <br />U <br />L <br />i <br />N a <br />�o <br />CU J <br />qq*. 00 <br />1 Q <br />�p <br />Q� J <br />m <br />�JLL <br />CQ <br />Cn <br />}�COJ <br />��>- <br />0 <br />co <br />LO n- <br />I- I,--N <br />a <br />0 <br />-6-0 <br />CU <br />E <br />L <br />0 <br />CU <br />L <br />CD <br />CD <br />! <br />V <br />C <br />_CU <br />CU <br />CU <br />C_ <br />w V <br />L_ <br />CD <br />U C <br />w G w <br />w <br />W N <br />Uj Y o <br />T _LU <br />c WLU <br />Cn J <br />ow <br />0 <br />W <br />H <br />w <br />a <br />O <br />C7 <br />O) <br />OI <br />W <br />Q <br />LLJ <br />o <br />N <br />J <br />W <br />N <br />0 <br />Cm <br />ZCD <br />U <br />0 <br />Z <br />� <br />W <br />� <br />N <br />N <br />W <br />C9 <br />U <br />a <br />o <br />o <br />U <br />m 1 0 1 <br />