Laserfiche WebLink
`qij►' � IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIINII ' � ' IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII —��— <br />II I I 'IIII IIII! IIII IIIII IIII IIII IIII IIII I IIII IIII IIII III IIII IIII IIII IIII I �� _ ___- _ _ <br />'� t f� I IiIIIIIIIIIIII IIIIIIII IIIIHIIIIII1IIIiII1,IlI IIIIII�;,,,; �!;, .............. <br />ra 5��,►► �, = 9��11� II1II <br />--- ����► � �•� 1—=L jllr �I� I <br />,III = -= /!�! =_==-111`,'1,,�1.��• a;moRr�I� <br />fi�:E;?}:�3�. ° �,`°h4�'��'S>�.`V �P� 5�3�'�cig'�+,�<.e;$ . � �• � �� �;i�. • �....r <br />• • � IIII,■I�Il�llll[4]■�•I , . •��� « — <br />NEW FREEZER <br />CONDENSER ROOF TOP <br />REMOTE CAPSULE PAK <br />� <br />a ow <br />^• �����a,,����������i�i�i�i�i�i�ii� ��i":L�i�i+��i�i►i�L�i�t���r�r�►►►► �" ��� I . <br />Ash <br />.ii •� '� ,,• ��IR <br />I '�I�, � �=_= IIIIIIIIIIIIIIIIU!!ull� <br />• �=== IIIIIIIIIIIIIIIIN!!�!l � � � %r. <br />ON1=a-a.:: 3:rk'and =arPi D�2�*g>'MI11—I`ra140 <br />'I�� <br />NEW RTU #1 <br />- <br />lox <br />.. <br />• ' • "av, 1I,, "1 1:., I S <br />P <br />�,oil NII r <br />I <br />�• �� �• <br />rrrr� � • • '� �, ' 11' • • I • . as <br />%'�IIT II � •► <br />I.11� <br />erg • • OEMI/�J • • C�a), <br />MIA <br />a� s. .. ■.�1 • • <br />/ 1OX6 SWD 10 X e AWMD <br />E3�,�� <br />COPE OF WORK: <br />HVAC CONTRACTOR TO FIELD VARIFY <br />LOCATION OF PROPOSED NEW & EXISINTG <br />EQUIPMENT AND PLACEMENT,PRIOR TO BID & <br />TO START OF WORK. ALL WORK IS SUBJECT <br />TO EXISTING FIELD CONDITIONS THAT MAY <br />ALTER THE DESIGN OF THIS PROJECT. <br />NE WALK IN COOLER <br />CO DENSER ROOF TOP UNIT <br />RE OTE CAPSULE PAK <br />VT EXHAUST FAN <br />-1 0 CFM <br />A PROX. LOCATION OF <br />H AT HOOD EXHAUST <br />—562 CFM <br />NEW RTU #1 <br />6 TON <br />40 CFM <br />241AY <br />X 24 <br />4 <br />A PROX. LOCATION OF <br />A SUL HOOD EXHAUST <br />—10 0 CFM <br />-401AY <br />CFM <br />24X 24 <br />4 <br />APPROX. LOCATION OF <br />AN UL HOOD FRESH —AIR <br />SUPPLY +800 CFM <br />-40 CFM <br />24 X 24 <br />4 AY <br />HVAC DESIGN VALUES <br />1 TON / 150 S.F. <br />AREA — 1,600 S.F. <br />1,405 S.F./1TON PER 150 S.F. <br />REQUIRED HVAC — 10.7 TONS <br />PROVIDED HVAC — 12.0 TONS <br />GENERAL HVAC NOTES ARE IN COMPLIANCE WITH 2O10 F.B.C. <br />1. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, <br />A MIN. OF 4 INCHES ON EACH SIDE IS SUFFICIENT. 2010 F.B.C.M. CHAPTER 13 SEC. 410.AB.3.0.3 & F.B.C.M. SEC. 603.1.3 <br />2. ALL DUCT SYSTEMS INSTALLED IN "NON -CONDITIONED" AREAS SHALL BE CONSTRUCTED WITH APPROVED MATERIAL AND <br />OF A VALUE OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB & MASTIC "OR" <br />APPROVED TAPES THAT EXTEND NOT LESS THAN 1 INCH AND LABELED IN ACCORDANCE WITH THE UL-181A, PART 1 FOR DUCT BOARD <br />OR UL 181B, PART 1 FOR FLEX. ALL CLOSURES 100% AND INSTALLATIONS SHALL BE INSTALLED AS PER 2007 F.M.C.M. CHAPTER 6, SEC. 603 <br />ALL THRU—WALL, FLOOR & CEILING PENETRATIONS INTO THE DUCT SECTION SHALL CONTAIN A BRANCH DUCT FABRICATED OF RIGID FIBROUS GLASS DUCT BOARD <br />OR RIGID METAL AND IS SEALED TO BOTH DUCT SECTION AND GRILLE SIDE WALL SURFACE. THE BRANCH DUCT SHALL BE FABED. AND ATTACHED <br />IN ACCORDANCE WITH M603.3 OR M603.4.2 RESPECTIVE TO THE DUCT TAPE USED. " DRAFT 2007 F.S.R.S. MECHANICAL VOLUME". <br />3. ALL DUCT TRUNK 90 DEGREE TURNS OR TEES, SHALL HAVE TURNING VANES. 3 PIECE OR 45 DEGREE TURNS CAN BE USED IN <br />PLACE OF 90 DEGREE TURNS AND DO NOT NEED TURNING VANES. <br />4. ALL REGISTERS, GRILLES & DIFFUSERS MUST BE TESTED IN ACCORDANCE WITH ASTM E 84, AND VOLUME DAMPERS OR <br />OTHER MEANS OF SUPPLY AIR ADJUSTMENT SHALL BE PROVIDED IN DUCTS OR AT EACH INDIVIDUAL REGISTER, GRILLE OR DIFFUSER. <br />5. AIR DISTRIBUTION SYSTEMS SHALL BE TESTED, ADJUSTED, AND BALANCED BY A LICENSED ENGINEER OF THIS STATE OR A CURRENT CERTIFIED ORGANIZATION. <br />EXCEPTION: 1) BUILDINGS WITH CAPACITIES OF 15 TONS OR LESS "PER SYSTEM" MAY BE TESTED AND BALANCED BY THE LICENSED MECH. CONTRACTOR. <br />EXCEPTION: 2) BUILDINGS WITH CAPACITIES OF 65,000 BTU/H OR LESS "PER SYSTEM" ARE "EXEMPT". F.B.C. 2007 CHAPTER 13, SEC. 410.1.ABC.4.1 <br />DOCUMENTS SHALL REQUIRE THAT ALL HVAC SYSTEMS BE BALANCED SERVING ZONES EXCEEDING 5000 SQ.FT. F.B.C. 2007 CHAP. 13, SEC. 410.AB.4.1 <br />6. AIR HANDLERS (OVER 2000 CFM) SHALL HAVE A SMOKE DETECTOR INSTALLED IN THE SUPPLY. F.B.C.M. 2007 CHAPTER 6, SEC. 606.2.1. <br />WHEN TWO AIR HANDLERS SHARE A COMMON SUPPLY OR RETURN "AIR DUCT" OR "PLEMUN" AND THE TOTAL CFM'S ARE GREATER THAN 2000, <br />A SMOKE DETECTOR SHALL BE INSTALLED IN THE SUPPLY AND RETURN AS PER F.B.C.M. 2007 SEC. 606.2.3 AND BE IN ACCORDANCE WITH NFPA 72 <br />SMOKE DETECTOR TEST STATIONS SHALL HAVE A TROUBLE INDICATOR LIGHT, INUNDATING ANY AIR DUCT TROUBLE. NFPA 90A 2002, CHAPTER 6 <br />NOTE: A "PLEMUN" CAN NOT BE USED AS AN OCCUPANCY SPACE OR STORAGE AREAS. AS PER. NFPA-90A, SEC. 4.3.10.1.1 <br />7. FIRE DAMPERS, SMOKE DAMPERS, COMBINATION FIRE/SMOKE DAMPERS AND CEILING DAMPERS LOCATED WITHIN AIR DUCTS <br />MUST BE INSTALLED BY MANUFACTURERS SPECS. AND BE TESTED IN ACCORDANCE WITH UL 555, AND THE F.B.C.M. 2007 CHAPTER 6, SEC. 607 <br />ALL DAMPERS LOCATED AT CEILING OR WALL PENETRATIONS MUST HAVE ACCESS DOORS TO RESET DAMPER. <br />UNLESS THE DAMPER IS IN THE DIFFUSER THAN IT CAN BE RESET THRU THE DIFFUSER. <br />SMOKE DAMPERS IN A DUCT MUST HAVE A DETECTOR WITHIN 5 FT. OF THE DAMPER WITH NO AIR INLETS OR OUTLETS BETWEEN THEM. <br />FOR FIRE AND SMOKE DAMPER ACTUATION METHODS REFER TO F.B.C.M. 2007 CHAPTER 6, SEC. 607.3.1.1 AND 607.3.2.1 <br />8. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO F.B.C.M. 2004 CHAPTER 6, SEC. 603.10 <br />9. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT OUTLET, OR SANITARY SEWER VENT OUTLET. <br />10. ALL EXHAUST DUCTS, SHALL BE CONSTRUCTED OF GALV. METAL F.B.C.M. 2007 CHAPTER 5, SEC. 501.4 <br />11. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE MECHANICALLY VENTILATED. <br />"EXCEPTION" RESIDENTIAL BATHROOMS HAVING NO LEES THAN 4 PERCENT OF FLOOR SPACE. F.B.C.M. 2007 CHAPTER 4, SEC. 402.3 <br />12. ALL EXHAUSTED BATHROOMS, CLOSETS & STORAGE ROOMS SHALL HAVE UNDER CUT DOORS OR A METHOD <br />FOR MAKE UP AIR TO BE RETURNED EQUAL TO THE AMOUNT OF CFM'S EXHAUSTED. F.B.C.M. 2007 CHAPTER 6, SEC. 601.4 <br />13. CONDENSATE FROM ALL COOLING COILS AND EVAPORATORS SHALL BE CONVEYED FROM THE DRAIN PAN OUTLET TO AN APPROVED PLACE OF DISPOSAL. <br />CONDENSATE SHALL NOT DISCHARGE INTO A STREET, ALLEY OR OTHER AREA AS TO CAUSE A NUISANCE. MUST TERMINATE A MIN. OF 18" FROM EXT. WALL. <br />PER AUTHORITY OVER JURISDICTION CONDENSATE DRAIN MAY DRAIN TO A STORM SYSTEM, UTILITY SINK, OR SEWER BY APPROVED MEANS. <br />CONDENSATE DRAIN LINE SHALL NOT BE LESS THAN 3/4 INCH DIAMETER AND SHALL NOT DECREASE IN SIZE. 2007 F.B.C.M. CHAPTER 3, SEC. 307.2.2 <br />ALL HORIZONTAL PRIMARY DRAIN LINE WITHIN UNCONDITIONAL AREA SHALL BE INSULATED. AS PER F.B.C.M. 2007 CHAPTER 3, SEC. 307.2.5 <br />AUXILIARY DRAIN PAN OR SECONDARY DRAIN LINE MAY BE REQUIRED WHERE DAMAGE TO ANY BUILDING MAY RESULT FROM OVERFLOW OR ANY STOPPAGE, <br />AUXILIARY DRAIN PAN MUST HAVE A MIN. DEPTH OF 1.5 INCHES AND BE A MIN. 3 INCHES LARGER THAN UNIT OR COIL AND HAVE SEPARATE DRAIN LINE <br />AN AUXILIARY PAN WITHOUT SEPARATE DRAIN LINE SHALL BE EQUIPPED WITH WATER LEVEL DETECTION DEVICE FOR SHUT OFF PRIOR TO OVERFLOW <br />METALLIC PAN MUST HAVE A MIN. THICKNESS 0.0276-INCH, NONMETALLIC 0.0625-INCHES. AS PER F.B.C.M. 2007 CHAPTER 3, SEC. 307.2.3 <br />ALTERNATIVE TO SEPARATE DRAIN LINE: A WATER LEVEL DETECTION DEVICE THAT WILL SHUT EQUIPMENT PRIOR TO OVERFLOW OF PAN. <br />WATER LEVEL DETECTION DEVICE SHALL CONNECT TO DRAIN PAN AT A HIGHER LEVEL THAN THE PRIMARY DRAIN CONNECTION. <br />CONDENSATE DRAIN LINE CAN BE STRAPPED WITH 2" NYLON STRAP AND SUPPORTED EVERY 10' VERTICAL AND 3' HORIZONTAL <br />14. REFRIGERANT PIPING FOR REFRIGERANT LINES SHALL BE INSULATED TO A THERMAL RESISTIVELY OF AT LEAST R=4HR. <br />SUCTION LINE MUST BE INSULATED IN ACCORDANCE WITH ASTM E96. AS PER THE F.B.C.R. 2007 CHAPTER 14, SEC. M1411.4 <br />15. IF HVAC EQUIPMENT OTHER THAN SPECIFIED BY DESIGNER IS SUBSTITUTED, IT'S CAPABILITIES OF SENSIBLE HEAT REMOVAL <br />MUST BE EQUAL TO THE EQUIPMENT SPECIFIED BY THE HVAC DESIGNER. <br />THE HVAC DESIGNER WILL NOT BE RESPONSIBLE FOR ANY SYSTEM NOT INSTALLED ACCORDING TO PLANS. <br />NOT TO SCALE <br />IE�O 5 p 5CON�EGf <br />�oOD F Ea <br />Svl <br />0 <br />pIR <br />ou1yJoE <br />t✓�f <br />Ou Lj PTE I� �O� <br />O V 0 <br />R AIR R RooF �U 1CON� oo f 0 �� K V v ����� �� <br />D��.RN AIR Rg 5 ����r� <br />SEE GENERAL HVAC NOTES #6 <br />SMOKE DETECTOR FOR A/H'S OVER 2000 CFM <br />AS PER F.B.C.M. SEC. 606 & NFPA 90—A <br />ROOFTOP PACKAGED HVAC UNIT DOWNFLOW DETAIL <br />RM CLIP <br />1" X 1-1/4" <br />14 GAUGE METAL <br />1" <br />03 <br />3/4" 4 <br />@ ° <br />3/16" 1-1/4" <br />3/8" <br />5/8" r14 GAUGE <br />METAL <br />ETAL <br />DIA. <br />"NOTE: 4 CLIPS PER UNIT". <br />2 EACH 3/16" X 3/8" SHEET METAL SCREWS <br />IN THE SLOTTED HOLES THRU RM CLIP IN UNIT <br />2 EACH 3/16" X 3/8" SHEET METAL SCREWS <br />IN THE SLOTTED HOLES THRU RM CLIP IN CURB <br />FAN SCHEDULE <br />FAN# MFG. <br />TYPE <br />CFM <br />VOLTS <br />PART# <br />DUCT DIA. <br />1 <br />BROAN <br />CEILING EXH. FAN <br />50. <br />120 <br />688 <br />5 INCHES <br />2 <br />BROAN <br />CEILING EXH. FAN <br />50 <br />120 <br />688 <br />5 INCHES <br />NOTE: ELECTRIC REQUIREMENT FOR EQUIPMENT TO BE <br />H . V. A. C. EQUIPMENT SCHEDULE FIELD VERIFIED BY ELECTICTIAN/MECHANICAL CONTRACTOR. <br />A/C <br />MFG. <br />MODEL NO. <br />SENSIBLE <br />LATENT <br />TOTAL-BTUH <br />COOLING/HEATING <br />EE�R <br />SEER <br />VOLTAGE <br />RLA. <br />M.C.A. <br />BREAKER <br />CFM <br />/ <br />CFM <br />1 <br />CARRIER <br />RTU 50TM-007-501 <br />53,300 <br />6 TONS <br />74,800 <br />15 KW <br />90,000 <br />11.3 <br />3/60 <br />208/230 <br />38.1 <br />40 <br />40 <br />2400 <br />2 <br />CARRIER <br />RTU 50TM-007-501 <br />53,300 <br />6 TONS <br />74,800 <br />15 KW <br />90,000 <br />11 3 <br />3/60 <br />208/230 <br />38.1 <br />40 <br />40 <br />2400 <br />ALL REGISTERS, GRILLS & DIFFUSERS BOTH SUPPLY & RETURN SHALL HAVE A FLAME <br />SPREAD RATING NOT OVER 25 WITHOUT EVIDENCE OF CONTINUED PROGRESSIVE COMBUSTION <br />AND A SMOKE DEVELOPED RATING NOT OVER 50 WHEN TESTED IN ACCORDENCE WITH <br />ASTM 84 (UL 723) U.L. 181 EROSION AND IMPACT TEST W/-R"—VALUES OF 4.2 AND 6. <br />AS PER F.B.C.M. CHAPTER 3, SEC. 603.15 <br />E I <br />TURNING VANES <br />SUPPORTS 5 ft. MAX. DISTANCE TYPICAL SPIN -IN FITTING / OR TAP COLLAR <br />APPROVED HANGER WIRE <br />MIN. R-6, 1 1/2" FIBERGLASS DUCT DRAW BAND FOR INTERIOR LINER <br />� > OR FLEX IN ATTIC OR UNCOND. SPACE APPROVED HANGER WIRE MIN. R-6, 1 1/2" INSULATED FLEX <br />SUPPORTS 6 ft. MAX. DISTANCE IN ATTIC OR UNCOND. SPACE <br />HANGER CHANNELL 1.5 INCH WIDE (min.) <br />tZy 1 <br />TYPICAL DUCT TRUNK SUPPORT DETAIL <br />SEE GENERAL HVAC NOTE # 2 DUCT TRUNK <br />FOR 100% CLOSURES AND INSTALLATIONS / <br />EXTERIOR LINER SEAL SHALL FASTEN TO DUCT TRUNK <br />AS PER 2004 FLORIDA MECHANICAL CODE SECTION 603 <br />DUCT SUPPORT INTREVALS <br />HORIZONTAL DUCT — 5FT. <br />VERTICAL DUCT — 6FT. <br />TYPICAL DIFFUSER <br />IN NO CASE MATERIAL SUPPORTING FLEX DUCT THAT IS IN <br />DIRECT CONTACT WITH IT MUST BE LESS THAN 1 J" INCHS WIDE <br />NONMETALLIC DUCTS <br />ALL DUCT SHALL BE TESTED IN ACCORDANCE WITH UL 181 <br />ALL DUCT SHALL BE LISTED AND LABELED AS CLASS 0 OR CLASS 1 <br />ALL DUCT SHALL BE A MIN OF R-6 INSULATION IN UNCONDITION AREAS <br />RTU FRESH AIR INTAKE <br />OUTSIDE AIR AS PER ASHRAE 62.1 <br />OUTDOOR AIR CALCULATIONS 62-1999ASHRAE <br />AREA DESIGNATION <br />FLOOR AREA <br />PERSONS / <br />1000 FT2 <br />TOTAL PERSONS <br />CFM / PERSONS <br />CFM / FT2 <br />CFM REQUIRED <br />CFM PROVIDED <br />SYSTEM DESIGNATION <br />FOOD PREP. <br />354 <br />20 <br />2 <br />15 <br />- - - - <br />75 <br />1000 <br />KITCHEN <br />252 <br />20 <br />3 <br />- - - - <br />75 <br />1200 <br />COORIDOR <br />36 <br />- - - - <br />---- <br />---- <br />.05 <br />30 <br />200 <br />DINING <br />670 <br />---- <br />43 <br />20 <br />---- <br />860 <br />2800 <br />RESTROOMS <br />62 <br />---- <br />- - - - <br />50/WC x 1 <br />_--- <br />100 <br />100 <br />®'SUPPLY DIFFUSERS <br />—RETURN AIR DIFFUSER <br />Qr — T—STAT. <br />Nil —DUCT SMOKE DETECTOR TEST STATION <br />0 — DUCT SMOKE DETECTOR <br />F/D —F/D DAMPER IN DUCT <br />[;�]—BALANCING DAMPER IN SUPPLY <br />—BALANCE DAMPER O/A <br />®SUPPLY & RETURN DIFFUSER <br />® WITH FIRE/SMOKE DAMPER <br />RETURN TRUNK <br />940 5300 RTU-1 = 4000 <br />RTU-2 = 3000 <br />EXHAUST AIR/FRESH AIR <br />INTAKE <br />CFM'S <br />BATHROOMS <br />50 CFM PER WATER CLOSET <br />—100 <br />4824 <br />ND-2—PSP—F <br />HOOD EXHAUST <br />—1000 <br />VHB <br />VHB <br />HOOD EXHAUST <br />—562 <br />TOTAL EXH. <br />—1,700 <br />EXHAUST HOOD <br />MAKE UP <br />+800 <br />MAKE UP FROM <br />UNITS <br />+970 <br />TOTAL MAKE UP <br />+1770 <br />BUILDING AIR BALANCE <br />+70 <br />OUTSIDE AIR SCHEDULE <br />SPACE <br />OCCUPANTS <br />CFM'S <br />BATHROOMS <br />50 CFM PER WATER CLOSET <br />-100 <br />4824 <br />ND-2-PSP-F <br />HOOD EXHAUST <br />-1000 <br />4824 <br />VH B <br />HOOD EXHAUST <br />-562 <br />TOTAL <br />—1,662 <br />CEILING <br />EXHAUST FAN <br />DETAIL <br />N T S <br />ROOF CURB <br />FLAT ROOF <br />CAP <br />CEILING/ROOF <br />ROOF <br />FLASHING <br />EXH. DUCT <br />FRAMING <br />EXHAUST <br />FAN <br />EXHAUST DUCT <br />P�� <br />CEILING <br />CEILING <br />�� <br />GRILLE <br />TEST BALANCE: <br />ALL DRAWINGS SHALL BE REVIEWED PRIOR TO WORK. <br />VERIFY TEST AND BALANCE OF HVAC EQUIPMENT <br />AND EXHAUST AND SUPPLY HOODS CFMS <br />AS REQUIRED TO ACHIEVE PROPER COOLING & <br />VENTILATIONS. ANY DESREPANCIES SHALL BE BROUGHT TO <br />THE ATTENTION OF THE DESIGN PROFESSIONAL. <br />FIELD CHANGES: <br />HVAC SYSTEM FIELD CHANGES SHALL BE DOCUMENTED <br />IN FORM OF AS—BUILTS, VALUE ENGINEERED DRAWINGS, <br />OR PRODUCT SPECIFICATIONS, AND SUBMITTED FOR APPROVAL. <br />SAMUEL <br />OLMEDO <br />ARCHITECT <br />FL. REG. AR0015027 <br />TEL. 407. 967. 3109 <br />soarcht @ yahoo.com <br />P.O. BOX 784825 <br />WINTER GARDEN, FL. 34778 <br />CONSULTANT <br />CONSULTANT <br />REVISIONS: <br />NO . DATE DESCRIPTION <br />INSTRUMENTS OF SERVICE OWNERSHIP <br />ALL REPORTS, PLANS, SPECIFICATIONS, <br />COMPUTER FILES, FIELD DATA, NOTES <br />INSTRUMENTS PREPARED BY THE <br />AND OTHER DOCUMENTS AND RELATED <br />INSTRUMENTS PREPARED BY THE <br />ARCHITECT OR CONSULTANTS AS <br />INTRUMENTS OF SERVICE SHALL REMAIN <br />THE PROPERTY OF THE ARCHITECT OR <br />CONSULTANT. THE ARCHITECT AND OR <br />THE CONSULTANT SHALL RETAIN ALL <br />COMMON LAW, STATUTORY AND OTHER <br />RESERVED RIGHTS, INCLUDING THE <br />COPYRIGHT THERETO. <br />MR. RANDY HAGAR <br />8c <br />MR. JOSHUA LINCOLN <br />J� <br />0 <br />M. <br />SUBS <br />ZEPHYR COMMONS <br />SHOPPING CENTER <br />7890 H WY 301 <br />ZEPHYRHILLS FLORIDA <br />HVAC PLAN <br />11 <br />NUMBER <br />HVAC PLAN <br />LEASABLE GROSS AREA - 1,600 S.F 1/4" = 1'-0" <br />- <br />�1UEL OLMEDO <br />AR0015027 <br />