Search
7894 Gall Blvd
Zephyrhills
>
Building Department
>
Building Plans
>
7894 Gall Blvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 5:21:35 PM
Creation date
2/19/2025 11:50:44 AM
Metadata
Fields
Template:
Building Plans
Street #
7894
Location
Gall Blvd
Contractor
L C Construction Management LLC
Building Plans - Permit #
16654
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LOCATION ADDRESS: <br />7894 Gail Boulevard <br />Zephyrhills, FL 33541 <br />SCOPE OF WORK <br />—PROVIDE NEW OFFICE SPACES LAYOUT <br />—NEW 1 HOUR FIRE RATED TENANT SEPARATION <br />—NEW PAINT FOR NEW OFFICE SPACE <br />—NEW ELECTRICAL WORK WIRES & FIXTURES (NEW OFFICE SPACE ONLY)) <br />—NEW GRILLES AND A/C DUCT WORK AS PER NEW LAYOUT <br />—NEW BATHROOM AND NEW SINK <br />FOLIO NUMBER: <br />35-25-0130-00000-0030 <br />SUBDIVISION: Zephyr Commons Phase 1 <br />ZONING DESIGNATION: HEAR USA <br />7894 GALL <br />COMMERCIAL <br />BUSINESS OCCUPANT LOAD: <br />BUSINESS AREAS: 1/100 SF GROSS <br />ACCORDANCE WITH TABLE 1004.1.2 OF F.B.C. 2014) <br />BUSINESS AREAS:: 1184 SF GROSS /100 = 11.84 PEOPLE <br />TOTAL OCCUPANT LOAD = 12 PERSONS <br />PERMIT NOTES: <br />OCCUPANCY TYPE: <br />USE: GROUP B <br />(This informstion is in accordance with FBC 2014 Chapter 3) <br />CONSTRUCTION TYPE: <br />TYPE: V (B) (PROTECTED) <br />(This informstion is in accordance with FBC 2014 Chapter 6) <br />FLAME SPREAD CLASSIFICATION: <br />THE INTERIOR FINISHES FLAME SPREAD CLASSIFICATION IS: "C" <br />FLAMESPREAD 76-200, SMOKE DEVELOPED 0-450. <br />SPRINKLERS NOTE: <br />THERE ARE NOT SPRINKLERS IN THIS BUIDING <br />FINISH NOTE: <br />ALL INTERIOR FINISH OF GROUP B SHALL COMPLY WITH TABLE 803.9 OF FBC 2010 <br />AS SHOWN BELOW. <br />INTFRIOR WAI I ANR (TII IN(; FINICH RFnI IIRFMFNTC RY IN l i IPAN(`Y <br />SPRINKLERED <br />ROOM AND ENCLOSED <br />GROUP <br />EXITS ENCLOSURES <br />CORRIDORS <br />SPACES <br />AND PASSAGEWAYS <br />C <br />GROUP B <br />B <br />C <br />EXTERIOR WALL RATED: <br />1 HOUR (IN ACCORDANCE WITH TABLE 503 OF F.B.C. 2014) <br />FIRE & SMOKE SEPARATION WALLS: <br />THE FIRE &/OR SMOKE SEPARATION WALLS AND PARTITION SHALL BE IDENTIFIED W/ <br />STENCILED SIGNS. <br />BUSINESS NOTE: <br />THIS BUSINESS IS TO PROVIDE PROFESSIONAL SERVICES AND <br />SUPPORT FOR PEOPLE WITH HEARING PROBLEMS, INCLUDING <br />HEARING TESTS AND EQUIPMENTS. <br />THE LAB IS ONLY USE FOR THE REPAIR AND MAINTENANCE OF <br />IMPAIRMENT DEVICES, NOT CHEMICAL NOR OTHER HAZARDOUS <br />SUBSTANCE IS GOING TO BE USE IN THIS FACILITY. <br />2" COPPER PIPE WATER LINE <br />2.5" / 1 " PVC PIPE CONDUITS <br />TO ELECTRICAL SERVICE & DMARC. <br />145 LF APPROX. <br />'qWwMisr-', %ftIIt%fi=:j n11 f :ra= <br />LOCATION PLAN <br />N.T.S. <br />BOULEVARD <br />GENERAL NOTES: <br />1.— ALL WORK SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE <br />FLORIDA BUILDING CODE 2014. ANY DISCREPANCIES <br />BETWEEN THE PLANS AND ABOVE REQUIREMENTS MUST BE CALL TO THE <br />A/E'S ATTENTION BEFORE PROCEEDING WITH THE WORKS. <br />2.— THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS IN THE PLANS, <br />HE MUST FAMILIARIZE HIMSELF WITH THE CONTRACT DOCUMENTS BEFORE PROCEEDING <br />WITH THE WORK AND REPORT TO A/E TO CLARIFY ANY DISCREPANCIES; <br />CONTRACTOR MUST COORDINATE THE WORK OF ALL TRADES AND INSURE THAT <br />ALL WORK CAN BE COMPLETE AS IT IS THE INTENT OF THE PLANS. <br />3.— CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS, INCLUDING SUBCONTRACTOR'S <br />PERMITS, INSPECTIONS AND APPROVALS FROM GOVERNING AGENCIES <br />WITH JURISDICTION OVER THE PROJECT BEFORE BEGINNING WORK. <br />4•— ALL WORK PERFORMED UNDER THIS CONTRACT SHALL COMPLY WITH THE <br />REQUIREMENTS OF THE UTILITY COMPANIES INCLUDING THE CITY OF DORAL <br />COUNTY PUBLIC WORKS DEPARTMENT, WHOSE SERVICES SHALL BE USED. <br />5.— ALL MANUFACTURERS SHALL SUBMIT SHOP DRAWINGS TO THE A/E <br />FOR APPROVAL PRIOR TO FABRICATION. <br />6.— THE A/E WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, <br />METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFETY <br />PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK, AND HE <br />WILL NOT BE RESPONSIBLE FOR THE CONTRACTOR'S FAILURE TO CARRY <br />OUT THE WORK IN ACCORDANCE WITH THE INTENT OF THE CONTRACT <br />DOCUMENTS. <br />7.— ALL MATERIAL AND WORKMANSHIP SHALL MEET THE REQUIREMENTS OF THE <br />APPLICABLE STANDARD SPECIFICATION OF THE AMER►CAN SOCIETY FOR <br />TESTING AND MATERIALS. <br />8.— THE GENERAL CONTRACTOR MAY SUBSTITUTE EQUIPMENT AND/OR MATERIALS <br />AS LONG AS SUCH CHANGES MEET ALL F.B. CODE REQUIREMENTS ARE <br />EQUAL TO THOSE SPECIFIED ON PLANS AND OBTAINS OWNER'S APPROVAL <br />IN WRITING, <br />9.— CONTRACTOR SHALL SUBMIT DADE COUNTY PRODUCT CONTROL APPROVAL <br />FOR WINDOWS, ROOFING & WATER PROOFING COMPONENTS AND ALL OTHER <br />PRODUCTS REQUIRING SAID APPROVAL. <br />10.— WORKMANSHIP: ALL WORK SHALL BE PERFORMED IN A MANNER CONSISTENT <br />WITH THE BEST PRACTICES FOR THE RESPECTIVE TRADES AND QUALITY <br />SPECIFIED. WORK NOT CONSISTENT WITH THE TRADE HIGHEST LEVEL OF <br />WORKMANSHIP WILL BE REJECTED. ANY WORK REJECTED SHALL BE REDONE <br />AT CONTRACTOR'S EXPENSE. CORRECTION OF DEFECTIVE WORK SHALL BE <br />STARTED NOT LATER THAN FIVE DAYS AFTER NOTICE IS GIVEN THE CONTRACTOR, <br />AND SHALL PROCEED WITHOUT DELAY UNTIL WORK IS COMPLETED. <br />11.— CLEANUP: THE CONTRACTOR AND ALL TRADES SHALL AT ALL TIMES KEEP <br />THE PREMISES CLEAN OF DEBRIS ARISING OUT OF THE WORK AND FREE FROM <br />ACCUMULATIONS OF WASTE MATERIALS OR RUBBISH CAUSED BY HIS OPERATIONS <br />OR OTHER TRADES. THE CONTRACTOR SHALL PROVIDE AT ALL TIMES A TRASH <br />CONTAINER ADEQUATE FOR THIS JOB. THE CONTRACTOR SHALL DELIVER ALL <br />WORK UPON COMPLETION OF THE JOB IN A CLEAN, READY —TO —USE CONDITION. <br />VACANT SPACE (7898) <br />1136 SF APPROX. <br />/ <br />/ <br />�5 <br />D\P�oNp,� <br />/ now <br />HEAR USA SPACE (7894) <br />/ 1184 SF APPROX. <br />/ <br />000' <br />0000 <br />0000 <br />Loge <br />17 JERSEY MIKE'S SUBS <br />EXISTING FLOOR PLAN <br />SCALE: 1 /4"=1'-0' <br />ALL FINISHED SURFACES SHALL HAVE PROTECTIVE COVERINGS REMOVED, AND <br />SURFACES CLEANED OF ALL MARKS, STAINS, SOIL, PAINT, OR ADHESIONS OF <br />OTHER MATERIALS AND LEFT IN PERFECT CONDITION. <br />o <br />D <br />j I <br />REVISIONS: <br />No. /DATE: <br />No./DATE: <br />THESE DRAWING & SPECIFICATIONS ARE <br />INSTRUMENTS OF SERVICE AND SHALL <br />REMAIN THE PROPERTY OF MDS <br />ENGINEERING CORP. WHETHER THE <br />PROJECT FOR WHICH THEY WERE <br />PREPARED IS EXECUTED OR NOT, THEY <br />ARE NOT TO BE USED IN ANY MANNER <br />ON OTHER PROJECTS OR EXTENSIONS <br />TO THIS PROJECT EXCEPT BY <br />AGREEMENT IN WRITING AND WITH THE <br />APPROPRIATE COMPENSATION TO MDS <br />ENGINEERING CORP. IS PROHIBITED. <br />CONTRACTOR IS RESPONSIBLE FOR <br />VERIFYING ALL SITE CONDITION PRIOR <br />TO PROCEEDING WITH WORK. <br />9 <br />C�: �•� OF <br />0: o <br />W <br />U <br />1 <br />O <br />M (--D <br />H—I r- (7) <br />� W � � o W Q CD�Na o I <br />I --I LLJ 11� <br />CD <br />w�Q00--))Q00 <br />C.41) Q o US <br />-�o z <br />00 � CD <br />N U CL- <br />Q <br />0 <br />o Q <br />I` z <br />U <br />L1 Q J � <br />> � = i-n <br />0 <br />O =z <br />0 <br />Qo <br />Cn ovo z <br />z � CD <br />Q = wCnW=`n Q <br />w CD CE Q � ct °O = <br />z LI <br />(ifL <br />� N � <br />ma � n QQoN01 <br />m 00 W zLLJ='LLO Q <br />r-- N �-j Cn r- <br />JOB No.: <br />DRAWN BY: M.D.S <br />SCALE: AS SHOW <br />DATE: 07-02-2015 <br />SHEET NAME: <br />LOCATION AND EXISTING FLOOR PLAN <br />Aml <br />SHEET 1 OF 7 <br />MDS ENGINEERING CORPORATION <br />