2"X4" 20 GA <br />CAL METAL <br />PARTITION <br />@ 16" O.C. <br />TYPICAL 2"XE <br />BACKING <br />TYP. WOOD BACKING DETAILS <br />N.T.S. <br />SCOPE OF WORK <br />-PROVIDE NEW OFFICE SPACES LAYOUT <br />-NEW 1 HOUR FIRE RATED TENANT SEPARATION <br />-NEW PAINT FOR NEW OFFICE SPACE <br />-NEW ELECTRICAL WORK WIRES, FIXTURES AND PANEL <br />-NEW GRILLES AND A/C DUCT WORK AS PER NEW LAYOUT <br />-NEW BATHROOM AND SINK <br />BUSINESS NOTE: <br />THIS BUSINESS IS TO PROVIDE PROFESSIONAL SERVICES AND <br />SUPPORT FOR PEOPLE WITH HEARING PROBLEMS, INCLUDING <br />HEARING TESTS AND EQUIPMENTS <br />FIRE NOTES <br />1-REVIEW AND APPROVAL BY THE AHJ SHALL NOT RELIEVE THE <br />APPLICANT OF THE RESPONSIBILITY OF COMPLIANCE WITH THIS CODE <br />PER NFPA 1:1.14. <br />2-PLAN SHALL COMPLY WITH THE FLORIDA FIRE PREVENTION CODE <br />(FFPC) 2014 EDITION WITH EDITION, NFPA 1, 2009 EDITION, & STATE <br />STATUTES, 2014 EDITION (ADOPTED REFERENCED PUBLICATIONS <br />FOUND HEREIN) <br />3-ALL DOORS IN THE MEAN OF EGRESS SHALL BE SINGLE ACTION <br />RELEASE AND SHALL NOT REQUIRE THE USE OF A KEY, TOOL OR <br />SPECIAL KNOWLEDGE TO OPEN FROM EGRESS SIDE. <br />4-FIRE EXTINGUISHERS SHALL BE MOUNTED NOT TO EXCEED 48" AFF <br />AND SHALL BE CURRENTLY DATED AND TAGGED BY LICENSED FIRE <br />EQUIPMENT COMPANY. <br />5-ADDI1IONAL EXIT SIGNS AND EMERGENCY LIGHTS MAY BE REQUIRED <br />BY THE FIRE INSPECTOR AT TIME OF THE FIRE FINAL. <br />6-DUCT DETECTOR'S REMOTE TEST SWITCHES SHALL BE INSTALLED IN <br />AN ACCESSIBLE LOCATION 48" AFF, NFPA 90A 6-4.4.3(1), & (2) <br />2002 EDITION. THE ACTIVATION OF THE DUCT DETECTOR SHALL <br />SHALL SHUT THE A/C UNIT DOWN IMMEDIATELY, WITHOUT DELAY. <br />7-THE NUMERICAL ADDRESS/SPACE # WILL BE PROVIDED ON ALL <br />EXTERIOR DOOR WEATHERPROOF AND CONTRASTING COLORS. IF THE <br />ADDRESS IS TO BE PLACED ON A WINDOW THE NUMBER SHALL BE <br />"WHITE", IF THEY ARE TO BE ON A LIGHT COLORED BACKGROUND <br />THEY SHALL BE "BLACK" <br />BARIATRIC SOUND BOOTHS NOTE: <br />THE BARIATRIC AUDIOMETRIC BOOTHS IS A MODULAR STRUCTURE CONSTRUCTED OF UNIQUE <br />ALL -STEEL, ALL -WELDED CONSTRUCTION AS STANDARD. WALL THICKNESS IS 2" WITH 16 <br />GA. EXTERIOR. 22 GA PERFORATED INTERIOR. (SEE PICTURE SB-1 FOR EXAMPLE). AT <br />TIME OF INSPECTION THE CONTRACTOR SHALL SUBMIT TO THE INSPECTOR ALL <br />MANUFACTURER SPECIFICATION IF IS REQUIRED. <br />PICTURE SB-1 <br />EXISTING EXTERIOR WALLS <br />NEW AND EXISTING ONE HOUR1 PARTY <br />NEW SECTION FOR <br />ACCESSIE <br />SERVICE COU <br />DETAIL AS-1 <br />SCALE: 1 /4" = 1'-O" <br />m <br />r�� NEW BATHROOM PLAN <br />�-jj SCALE: Y2"=1'-01 <br />.00 <br />I <br />ACCESSIBLE <br />BATHROOM <br />18"MIN. <br />LAVATORY <br />BACK WALL <br />X <br />Q <br />o 33" 36" <br />{ N 17-19 19"MIN. <br />HAN171CAPPED <br />WATER CLOSET <br />54"MIN <br />PAPER 42"MIN--�--�� 12"MIN <br />� t <br />33� 36 19MIN <br />17-19 <br />SIDE <br />WALL <br />ACCESSIBLE BATHROOM DETAILS <br />NEW AND EXISTING DOORS SCHEDULE <br />MARK <br />SIZE <br />WITH <br />TYPE <br />MATERIAL <br />FRAME <br />REMARKS <br />1 <br />3'X6'-8" <br />1-3/4" <br />FLUSH <br />METAL & GLASS <br />METAL <br />EXTERIOR FRONT DOOR <br />(EXIST.) <br />2 <br />31X6'-8" <br />1-3/4" <br />FLUSH <br />METAL <br />METAL <br />EXTERIOR REAR DOOR <br />EXIST. <br />3 <br />31-0"X6'-8" <br />1-1 /4" <br />FLUSH <br />WOOD <br />WOOD <br />INTERIOR DOOR (NEW) <br />NOTE <br />FIRE RATED DOORS WITH PRODUCT APPROVAL AND SEPARATE PERMIT <br />2" COPPER PIPE WATER LI <br />FIRE EXTINGUISHE <br />2.5" / 1 " PVC PIPE CONDL <br />TO ELECTRICAL SERVICE & DMA <br />145 LF APPR <br />PROPOSED FLOOR PLAN <br />TACTILE EXIT SIGN <br />TACTILE ACCESSIBLE WC SIGN <br />TACTILE SIGN REQUIREMENTS <br />TACTILE SIGN STATING "EXIT" AND COMPLYING WITH ADA STANDARD <br />2014, SECTION 703. WC ACCESSIBLE SIGN SHALL BE INSTALLED ON <br />THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR. WHERE <br />THERE IS NO WALL SPACE ON THE LATCH SIDE, SIGNS SHALL BE <br />PLACED ON THE NEAREST ADJACENT WALL, PREFERABLY ON THE RIGHT. <br />MOUNTING HT SHALL BE 60" FF TO BOTTOM HIGHEST BASELINE <br />CHARACTER OF SIGN. MOUNTING LOCATION SHALL BE DETERMINED SO <br />THAT A PERSON MAY APPROACH WITHIN 3" OF SIGN WITHOUT <br />ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE SWING <br />OF THE DOOR. <br />FINISH SCHEDULE <br />AREA <br />FLOOR <br />BASEBOARD <br />WALL <br />CEILING <br />OFFICES & HALLWAY <br />CARPET TILE <br />VINYL <br />DRYWALL <br />CEILING PANELS <br />RESTROOMS <br />SHEET VINYL <br />VINYL <br />T)I�1. BOARD PNMHI � Fl�AS <br />RAW BW (FIf) AT 4 <br />CEILING PANELS <br />* NOTES <br />-CONTRACTOR SHALL VERIFY ALL FINISHES W/OWNER PRIOR TO PURCHASING MATERIALS <br />CONTRACTOR SHALL VERIFY ALL COLORS W/ OWNER PRIOR TO COMMENCEMENT OF WORK <br />-THE PUBLIC RESTROOM SHALL BE LINED WITH NONABSORBENT MATERIAL TO A HEIGHT <br />OF 4 ft ABOVE THE FLOOR MIN. IN ACCORDANCE WITH FBC 2014 <br />XTINGUISHER <br />REVISIONS: <br />No./DATE: <br />No./DATE: <br />THESE DRAWING & SPECIFICA11ONS ARE <br />INSTRUMENTS OF SERVICE AND SHALL <br />REMAIN THE PROPERTY OF MDS <br />ENGINEERING CORP. WHETHER THE <br />PROJECT FOR WHICH THEY WERE <br />PREPARED IS EXECUTED OR NOT, THEY <br />ARE NOT TO BE USED IN ANY MANNER <br />ON OTHER PROJECTS OR EXTENSIONS <br />TO THIS PROJECT EXCEPT BY <br />AGREEMENT IN WRITING AND WITH THE <br />APPROPRIATE COMPENSATION TO MDS <br />ENGINEERING CORP. IS PROHIBITED. <br />CONTRACTOR IS RESPONSIBLE FOR <br />VERIFYING ALL SITE CONDITION PRIOR <br />TO PROCEEDING WITH WORK. <br />CO <br />1 ®: uw ,o 0. p <br />,�.C-D s'o <br />con <br />o Q <br />U � <br />V O <br />M O <br />t` <br />W 00 © CD <br />Li_ <br />'►� 0 <br />W Q� m � <br />Q O US <br />c w z CD --� <br />0c) <br />JOB No.: <br />DRAWN BY: M.D.S <br />SCALE: AS SHOW <br />PROPOSED FLOOR PLAN <br />A=2 <br />SHEET 2 OF 7 <br />MDS ENGINEERING CORPORATION <br />