My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7894 Gall Blvd
Zephyrhills
>
Building Department
>
Building Plans
>
7894 Gall Blvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 5:21:35 PM
Creation date
2/19/2025 11:50:44 AM
Metadata
Fields
Template:
Building Plans
Street #
7894
Location
Gall Blvd
Contractor
L C Construction Management LLC
Building Plans - Permit #
16654
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL PLUMBING NOTES <br />1. ALL WORK SHALL CONFORM WITH FLORIDA BUILDING CODE 2014 <br />EDITION (F.B.C.2014), FEDERAL ORDINANCES GOVERNING THE <br />INSTALLATION OF THE PLUMBING SYSTEM. IF WORK AS LAID <br />OUT, INDICATED OR SPECIFIED IS CONTRARY TO OR CONFLICTS <br />WITH LOCAL ORDINANCES, BUILDING CODES AND REGULATIONS, <br />THE CONTRACTOR SHALL REPORT IN WRITING TO THE <br />ARCHITECT/ENGINEER. BEFORE SUBMITTING A BID. THE <br />ARCHITECT/ENGINEER. WILL THEN ISSUE INSTRUCTIONS AS <br />HOW TO PROCEED. <br />2. THE DRAWINGS ARE TO BE CONSIDERED DIAGRAMMATIC, NOT <br />NECESSARILY SHOWING IN DETAIL OR TO SCALE ALL OF THE <br />MINOR ITEMS. UNLESS SPECIFIC DIMENSIONS ARE SHOWN, THE <br />STRUCTURAL, ARCHITECTURAL AND SITE CONDITIONS SHALL <br />GOVERN THE EXACT LOCATIONS. CONTRACTOR SHALL FOLLOW <br />DRAWINGS IN LAYING OUT WORK, CHECK DRAWINGS OF ALL <br />TRADES TO VERIFY SPACES IN WHICH WORK WILL BE INSTALLED <br />AND MAINTAIN MAXIMUM HEAD ROOM, AND SPACE CONDITIONS <br />AT ALL POINTS. WHERE HEAD ROOM, OR SPACE CONDITIONS <br />APPEAR INADEQUATE, ARCHITECT/ ENGINEER SHALL BE <br />NOTIFIED BEFORE PROCEEDING WITH INSTALLATION. THIS <br />CONTRACTOR SHALL, WITHOUT EXTRA CHARGE, MAKE FIELD <br />MODIFICATION IN LAYOUT AS NEEDED TO PREVENT CONFLICT <br />WITH WORK OF VARIOUS TRADES OR FOR PROPER EXECUTION <br />OF THE WORK . <br />3. EXAMINE ALL DRAWMNGS CAREFULLY PRIOR TO SUBMITTING A BID. <br />CONTRACTOR WILL BE REQUIRED TO FURNISH, INSTALL AND/OR <br />CONNECT WITH APPROPRIATE SERVICES ALL PLUMBING ITEMS <br />SHOWN ON ANY OF THE ARCHITECTURAL, AIR CONDITIONING, <br />ELECTRICAL AND SPRINKLER DRAWINGS WITHOUT ADDITIONAL <br />EXPENSE TO THE OWNER. IF DISCREPANCIES , CONFLICTS , <br />INTERFERENCE OR OMISSIONS OCCUR BETWEEN DRAWINGS, <br />NOTIFY IN WRITING THE ARCHITECT/ ENGINEER IN AMPLE TIME <br />TO PERMIT REVISIONS BEFORE THE BIDS ARE SUBMITTED. <br />4. INSTALL MATERIALS AND EQUIPMENT IN A NEAT AND FIRST <br />CLASS WORKMANLIKE MANNER. THE OWNER RESERVES THE <br />RIGHT TO DIRECT REMOVAL AND REPLACEMENT OF ITEMS WHICH, <br />IN HIS OPINION, DO NOT PRESENT A NEAT AND WORKMANLIKE <br />APPEARANCE. REMOVAL AND REPLACEMENT IS TO BE DONE <br />IMMEDIATELY WHEN DIRECTED BY THE OWNER IN WRITING, AT <br />THE SOLE EXPENSE OF CONTRACTOR. <br />5. START OF WORK BY CONTRACTOR SHALL BE CONSIDERED AS <br />ACCEPTANCE BY HIM OF ALL CLAIMS OR QUESTIONS AS TO <br />SUITABILITY OF THE WORK OF OTHER. TRADES OR OTHER <br />CONTRACTORS TO RECEIVE HIS WORK. THIS CONTRACTOR <br />SHALL REMOVE AND REPLACE, AT HIS EXPENSE, ALL PLUMBING <br />WORK WHICH MAY HAVE TO BE REMOVED BECAUSE OF <br />INTERFERENCE WITH OTHER TRADES. <br />6. THIS CONTRACTOR SHALL OBTAIN AND PAY ALL INSURANCE, <br />FEES, PERMITS , ASSOCIATION DUES, ROYALTIES AND TAXES OF <br />WHATEVER NATURE SHALL APPLY TO THIS WORK. HE SHALL ALSO <br />N.T,S <br />PAID ALL THE INSPECTION FEES AS MAY REQUIRED BY LAW OR <br />ORDINANCE AND SHALL KEEP THE OWNER HARMLESS FROM ANY <br />DAMAGE AND EXPENSE ARISING FROM ANY VIOLATION OF LAWS, <br />RULES OR ORDINANCES. <br />7. PROVIDE MEANS "FURNISH AND INSTALL". <br />8. DO A COMPLETE JOB, EVERYTHING CONNECTED, READY FOR USE. <br />9. SHOP DRAWINGS: CONTRACTOR SHALL FURNISH THE ENGINEER <br />WITH SHOP DRAWINGS OF EQUIPMENT PRIOR TO PURCHASE <br />FOR APPROVABY PROPER AUTHORITIES. <br />10. AT COMPLETION OF JOB THE PLUMBING CONTRACTOR SHALL <br />GIVE THE OWNER AN AS -BUILT SET OF REPRODUCIBLE SEPIAS <br />SHOWING THE EXACT LOCATION OF ALL INSTALLATIONS. <br />11. PLUMBING CONTRACTOR SHALL PRESSURE TEST ALL PIPING AS <br />REQUIRED BY CODE. TEST SHALL BE WITNESSED AND APPROVED <br />TO THE OWNER. <br />12. THE PLUMBING CONTRACTOR SHALL WARRANT ALL <br />WORKMANSHIP AND MATERIALS FOR ONE YEAR FROM THE DATE <br />OF FINAL WORK ACCEPTANCE BY OWNER. ANY BREAKDOWN <br />OCCURRING IN FIRST YEAR SHALL BE REPAIRED AT NO EXPENSE <br />13. PROVIDE BATHROOM FIXTURES AS SPECIFIED OR AS SELECTED BY <br />OWNER AND TO COMPLY W/F.B.C.2014 SPECIALLY CHAPTER 11. <br />14. PROVIDE SHUTOFF VALVE FOR EACH FIXTURE. <br />15. WHEREVER NOT SIMILAR METALS ARE TO BE JOINED, A DIELECTRIC <br />FITTING SHALL BE PROVIDED TO CONNECT BOTH TYPES OF PIPES. <br />16. PLUMBING CONTRACTOR SHALL PROVIDE AIR CONDITIONING <br />CONDENSATE DRAIN AND TRAP. SEE AIR CONDITIONING PLANS <br />FOR LOCATION OF UNITS AND DRAINS. <br />17. ALL SANITARY FITTINGS SHALL BE DIRECTIONAL TYPE. <br />18. MATERIALS <br />A. COLD WATER PIPING DOWNSTREAM OF WATER METER SHALL BE <br />TYPE "L" COPPER BELOW GROUND AND TYPE "M" COPPER ABOVE GROUND. <br />B. COLD WATER PIPES INSIDE OF SLAB SHALL BE TYPE "K" SOFT COPPER <br />INSTALL INSIDE POLYETHYLENE CONDUIT. NO JOINTS PERMITTED INSIDE SLAB. <br />C. SANITARY WASTE AND VENT 4"0 AND SMALLER SHALL BE P,V.C.,SCHEDULE 40 <br />S. STORM LINES INSIDE BUILDING SHALL BE P.V.C. SCHEDULE 40 <br />E. IN COASTAL AREAS ALL SANITARY AND STORM PIPING OUTSIDE OF BUILDING <br />SHALL BE SCHEDULE 40, PVC. <br />F. CONDENSATE DRAIN PIPE SHALL BE SCHEDULE 40, PVC PIPE AND FITTINGS. <br />G. WATER HEATER RELIEF AND DRAIN LINE SHALL BE TYPE "L" COPPER, <br />MIN. 3/4" DIA. <br />�UppR) <br />d( <br />MAXIMUM FLOW RATE AND CONSUMPTION <br />FOR PLUMBING FIXTURES AND FIXTURE FITTINGS <br />PLUMBING FIXTURE <br />OR FIXTURE FITTING <br />MAXIMUM FLOW RATE <br />OR QUANTITY <br />LAVATORY, PRIVATE <br />1.0 GPM @ 60 PSI <br />LA VA TOR Y, PUBLJC <br />0. 5 GPM @ 60 PSI <br />LAVATORY, PUBLIC, METERING <br />OR SELF -CLOSING <br />0.25 GALLONS PER METERING CYCLE <br />SHOWER HEAD <br />1.5 GPM @ 80 PSI <br />SINK FAUCET <br />1.0 GPM @ 60 PSI <br />URINAL <br />0.5 GALLON PER FLUSHING CYCLE <br />WATER CLOSET <br />1.28 GALLON PER FLUSHING CYCLE <br />NOTE: <br />(R) RELOCATE <br />(E) EXISTING <br />(N) NEW <br />(E/R) EXISTING <br />RELOCATE <br />N.T.S <br />HAMMER ARRESTOR: <br />- AMTROL, MODEL 500 <br />- INSTALL IN ACC. LOCATION. <br />- CONNECTION <br />TION SIDE 1/2" NPT <br />- DIAMETER: 3-3/8" <br />MAX. PRESSURE: 150 PSI <br />MAX. TEMP: 200' F <br />MAX. SHOCK PRESSURE. 200 PSI <br />NOTE: <br />ALL SANITARY PIPE 2 1/2"0 OR SMALLER <br />SHALL RUN @ 1/4" SLOPE PER L.FT. <br />3" AND LARGER @ 1/8" SLOPE PER L. FT. <br />PLUMBING RISERS & NOTES <br />SCALE: 1 /4"=1'-0" <br />WATER PIPING SIZE-2 <br />Q 1/2"0 CW/HW <br />© 1/2„0 CW <br />d 3�4"O CW/HW"0 HW <br />® 1/2"0 HW <br />Q 3/4 "0 CWS <br />(Z) 1 "o CWS <br />® 3/4 "0 HWS <br />® 1 "0 CWS/1/2"O HWS <br />1@0 1-1/4"0 CWS <br />11 1 "0 CWS/1 /2"O HWS <br />1-1/4"0 CW,1/2"O HW <br />Q 2"0 CW <br />Pvp) <br />REVISIONS: <br />No./DATE: <br />No./DATE: <br />THESE DRAWING & SPECIFICATIONS ARE <br />INSTRUMENTS OF SERVICE AND SHALL <br />REMAIN THE PROPERTY OF MDS <br />ENGINEERING CORP. WHETHER THE <br />PROJECT FOR WHICH THEY WERE <br />PREPARED IS EXECUTED OR NOT, THEY <br />ARE NOT TO BE USED IN ANY MANNER <br />ON OTHER PROJECTS OR EXTENSIONS <br />TO THIS PROJECT EXCEPT BY <br />AGREEMENT IN WRITING AND WITH THE <br />APPROPRIATE COMPENSATION TO MDS <br />ENGINEERING CORP. IS PROHIBITED. <br />CONTRACTOR IS RESPONSIBLE FOR <br />VERIFYING ALL SITE CONDITION PRIOR <br />TO PROCEEDING WITH WORK. <br />1117 <br />ot`�- , <br />• W w �' <br />a a�'i'• ��`' � r <br />O � <br />M O <br />� CO <br />o W W Q CD N 2) 1 <br />LL <br />QD <br />Q 00 <br />o cCy) <br />�Q 3: m'� <br />0-) � z <br />0 0 <br />op 1— O <br />CV U a_ <br />JOB No.: <br />DRAWN BY: M.D.S <br />SCALE: AS SHOW <br />PLUMBING RISERS AND NOTES <br />P=2 <br />SHEET 7 OF 7 <br />MDS FNI;INFFRIN(; (ORPORATION <br />