Laserfiche WebLink
I C-0.9 <br />C-1 <br />C-2 <br />( C-3 <br />Z'BUILDII <br />6 <br />\ C-4.7 — <br />1_� <br />l C-4.9 <br />\ GD i C-C 1 i GB C-A.6 (C.A.4 ; C-A.2 <br />I <br />I <br />i f I I i l <br />REAR ,I _ <br />_C <br />GC.1> r <br />C <br />LEFTCN� RIGHT <br />FRONT <br />D1 D1 D1 D1 <br />4 / \ 4 4 � \I 4 <br />I I <br />I I I I I i <br />1 J- <br />DB8 �GB.7 ( C-B.6 (�.5) GB3ELECTRICAL FLOOR PLAN - BUILDING C <br />FAI <br />T <br />I T <br />TYPE <br />SYMBOL <br />MANUFACTURER <br />CATALOG NO. <br />VOLT <br />LAMPS <br />MOUNTING <br />A <br />THOMAS <br />SL9421-7 <br />120 <br />(1) 60 W INCAND CLEAR GLASS <br />WALL MOUNT 1 CLEAR GLASS <br />B <br />EA <br />STAPLES PROTOTYPICAL TYPE G; SEE GENERAL NOTE 3. <br />277 <br />NIA (BATTERY PACK) <br />WALL MOUNT <br />B1 <br />Q <br />STAPLES PROTOTYPICAL TYPE G1; SEE GENERAL NOTE 3. <br />12 <br />(1) 8 W HALOGEN <br />WALL MOUNT <br />D <br />CAPRI <br />CMQ10H70V1-S56P <br />120 <br />(1) 70 W MH <br />RECESSED MOUNTED <br />D1 <br />® <br />STAPLES PROTOTYPICAL TYPE J; SEE GENERAL NOTE 3. <br />277 <br />(1)175 W MH <br />RECESSED MOUNTED <br />EM <br />BEGHELLI <br />XLP-SI <br />120 <br />(INCLUDED) <br />WALL @ 9-0" A.F.F. <br />X <br />STAPLES PROTOTYPICAL TYPE F; SEE GENERAL NOTE 3. <br />120 <br />LED (INCLUDED) <br />12'-0" A.F.F. <br />ERAL NOTES: <br />ALL FLUORESCENT LIGHTING FIXTURES SHALL HAVE <br />ENERGY SAVING LAMPS AND ELECTRONIC BALLASTS. <br />PROVIDE NECESSARY MOUNTING HARDWARE AND <br />ACCESSORIES FOR ALL FIXTURES. <br />[2. <br />3. FOR FIXTURE TYPES B, B1, C, AND X, CONSULT STAPLES' <br />APPROVED NATIONAL ACCOUNT VENDOR: <br />STANDARD ELECTRIC <br />14 JEWEL DRIVE <br />WILMINGTON, MA 01887-0676 <br />800-367-6285 <br />www.standardelectric.com <br />NOTES O: <br />O TWO 3" PVC CONDUITS ROUTED UNDERGROUND FROM TELEPHONE COMPANY <br />NETWORK. COORDINATE EXACT LOCATION WITH STAPLES BUILD -OUT DRAWINGS. <br />STUB UP AND CAP AT 24" A.F.F. PROVIDE PULL CORD IN EACH CONDUIT. <br />2O THREE 4" EMT CONDUITS ROUTED UNDERGROUND FROM FUTURE UTILITY <br />TRANSFORMER LOCATION. COORDINATE EXACT LOCATION WITH STAPLES BUILD -OUT <br />DRAWINGS. STUB UP AND CAP AT 6" A.F.F. PROVIDE PULL CORD IN EACH CONDUIT. <br />1 <br />3 TEMPORARILY CIRCUIT EMER & EXIT LIGHTS TO HOUSE PANEL OF BUILDING B. <br />DURING FUTURE TENANT IMPROVEMENT, EMER & EXIT LIGHTS WILL BE RECIRCUITED <br />TO APPROPRIATE BUILDING C PANEL. <br />O INSTALL LIGHT FIXTURE AND STUB 314" CONDUIT WITH PULL CORD INTO SPACE FOR <br />CONNECTION TO FUTURE TENANT PANEL. <br />O7J-BOX FOR FUTURE TENANT SIGN. COORDINATE LOCATION WITH ARCHITECTURAL. <br />STUB 314" CONDUIT WITH PULL CORD INTO SPACE FOR FUTURE CONNECTION. <br />O (NOT USED.) <br />O INSTALL FIXTURE B1 (LAMPHEAD UNIT) WITH FIXTURE B (EMERGENCY BATTERY PACK) <br />AND CONNECT TOGETHER WITH 12 VOLT WIRING PER MANUFACTURER'S <br />SPECIFICATIONS. DO NOT CONNECT TO POWER CIRCUIT, BUT ALLOW FOR FUTURE <br />CONNECTION OF FIXTURE B TO FUTURE POWER CIRCUIT. <br />O CIRCUIT EXTERIOR LIGHTS TO HOUSE PANEL OF BUILDING B VIA THE LIGHTING <br />CONTACTOR OF BUILDING B. <br />O CIRCUIT EXTERIOR LIGHTS TO HOUSE PANEL OF BUILDING D VIA THE LIGHTING <br />CONTACTOR OF BUILDING D. <br />GENERAL NOTES: <br />1. FIRE ALARM SYSTEM TO BE PROVIDED DURING FUTURE TENANT IMPROVEMENT. <br />LIGHTING NOTES <br />1. VENDOR SHALL VERIFY ALL FIXTURE QUANTITIES. <br />2. NOT USED. <br />3. MOUNTING HEIGHTS INDICATED ARE TO THE CENTER LINE OF DEVICE OR FIXTURE <br />UNLESS OTHERWISE NOTED, <br />4. ALL FIXTURES TO BE PROVIDED BY, RECEIVED, STORED & INSTALLED BY <br />ELECTRICAL CONTRACTOR. <br />5. ELECTRICAL CONTRACTOR SHALL SUPPLY 10% ADDITIONAL SPARE OF ALL LAMP <br />TYPES TO BE LEFT AT JOB SITE AT END OF JOB. <br />ELECTRICAL LEGEND <br />NOT ALL DEVICES SHOWN IN LEGEND ARE REQUIRED. <br />REVIEW POWER & LIGHTING PLANS AND DETAILS <br />FOR ITEMS WHICH APPLY TO THIS PROJECT. <br />X <br />EXIT LIGHT (SHADE AREA INDICATES DIRECTION) LETTER INDICATES TYPE <br />SEE LIGHT FIXTURE SCHEDULE TO CONFIRM TYPE AND MOUNTING. <br />BATTERY POWERED EMERGENCY LIGHT <br />TELEPHONE WALL OUTLET, PROVIDE SINGLE GANG BOX WITH 3/4- <br />CONDUIT WITH PULL WIRE AND INSULATING BUSHING STUBBED INTO <br />CEILING SPACE. MOUNT BOX 18" A.F.F. U.O.N. <br />DUPLEX RECEPTACLE, MOUNT 180 A.F.F. U.O.N. <br />DUPLEX RECEPTACLE MOUNTED ABOVE COUNTER HEIGHT U.O.N. <br />t <br />GROUND FAULT INTERRUPTER RECEPTACLE, LEVITON #6898—I, MOUNT <br />ABOVE COUNTER HEIGHT U.O.N. <br />1e' <br />DUPLEX RECEPTACLE, ISOLATED GROUND TYPE, LEVITON #5362—IGI <br />MOUNTED ABOVE COUNTER HEIGHT. U.O.N. <br />TAMPER -RESISTANT DUPLEX RECEPTACLE PAWASEWOUR (TR63-HW) <br />DUPLEX RECEPTACLE, ISOLATED GROUND TYPE, LEVITON #5362-IGI <br />MOUNT AT 18" A.F.F. U.O.N. <br />w� <br />DUPLEX RECEPTACLE, WEATHERPROOF GROUND FAULT INTERRUPTER <br />TYPE, LEVITON, MOUNT AT 18- A.F.G., U.O.N. <br />DUPLEX RECEPTACLE, MOUNTED ABOVE STOREFRONT WINDOWS <br />QUADRIPLEX RECEPTACLE, MOUNT AT 18" A.F.F. U.O.N. <br />JO <br />JUNCTION BOX (FLUSH MOUNT IN FINISHED AREAS U.O.N.) <br />LIGHTING, POWER, OR SYSTEMS PANELBOARDS. <br />�se/I�P <br />MAIN SWITCHBOARD OR MAIN DISTRIBUTION PANEL <br />CONDUIT CONCEALED IN WALL, BELOW SLAB, OR ABOVE CEILING. <br />A-1,3 <br />CONDUIT RUN CONCEALED IN WALLS BELOW SLAB, OR CEILING SPACES. <br />ARROWS INDICATE HOMERUN. SMALL HASHMARKS INDICATE NUMBER OF <br />HOT CONDUCTORS, AND LARGE HASHMARK INDICATES NEUTRAL. <br />SUBSCRIPT INDICATES PANEL AND CIRCUIT NUMBERS. GROUND <br />CONDUCTOR REQUIRED IN ALL CONDUITS BUT NOT INDICATED. <br />A-37:39:41 <br />SUBSCRIPT INDICATES PANEL -AND NUMBERS WITH COLONS <br />INDICATE 2 OR 3 POLE CIRCUITS. <br />DISCONNECT SWITCH <br />100/3/60 <br />NON-FUNSE INDICATES <br />DDE-ESI*INDICATES <br />D;ISCONT <br />DUAL EELEMMEENTT)FUSES <br />MOTOR PERMANENTLY CONNECTED WITH FLEXIBLE CONDUIT <br />(HORSEPOWER OR EQUIPMENT INDICATED) <br />THERMOSTAT. PROVIDE SINGLE GANG BOX WITH 1 /2- C. STUBBED <br />TO <br />INTO CEILING SPACE, MOUNT 60" A.F.F. U.O.N. (COORDINATE WITH <br />MECHANICAL DRAWINGS PRIOR TO ROUGH -IN) <br />® FIRE ALARM PULL SWITCH <br />D HORN/STROBE <br />O OR/ A /SMOKE DETECTOR: EDWARDS JRSIGA-PS <br />'l_J 'EIF BATH ROOM FAN LIGHT (BROAN S150L) <br />x0 FIRE ALARM SPRINKLER TAMPER SWITCH <br />FIRE ALARM SPRINKLER FLOW SWITCH <br />® OCCUPANCY SENSOR BY WATT STOPPER. <br />EG <br />ABBREVIATIONS <br />EQUIPMENT GROUND <br />NIL <br />NIGHT LIGHT <br />IG <br />ISOLATED GROUND <br />PC <br />PULL CHAIN <br />WP <br />WEATHERPROOF <br />C/T <br />CURRENT TRANSFORMER <br />EC <br />EMPTY CONDUIT <br />EX <br />EXISTING DEVICE TO REMAIN <br />EWH <br />ELECTRIC WATER HEATER <br />AFF <br />ABOVE FINISH FLOOR <br />EWC <br />ELECTRIC WATER COOLER <br />AFG <br />ABOVE FINISH GRADE <br />E/F-EF <br />EXHAUST FAN <br />U.O.N. <br />UNLESS OTHERWISE NOTED <br />A/H-AHU <br />AIR HANDLING UNIT <br />N.T.S. <br />NOT TO SCALE <br />ACC-CU <br />CONDENSING UNIT <br />NIC <br />NOT IN CONTRACT <br />RTU <br />ROOF TOP UNIT <br />TYP. <br />TYPICAL <br />FACP FIRE ALARM CONTROL PANEL VTC <br />LB LOCK BREAKER <br />GFI GROUND FAULT INTERRUPTER <br />TTC TELEPHONE TERMINAL CABINET <br />VIA TIME CLOCK <br />NOTE: MOUNTING HEIGHTS NOTED ARE TO BOTTOM OF DEVICE SHOWN. U.O.N. <br />[=� <br />U <br />C <br />O <br />CL <br />O <br />rLn <br />V <br />CU ro ao <br />c <br />UJM XU <br />.L M c <br />W-aU_ -C) <br />wEco <br />m � <br />CL CU <br />-L > <br />w iM Fes— fn <br />J <br />U <br />n � <br />V <br />_Z <br />0 <br />J_ <br />m <br />Z <br />cn <br />a <br />Q <br />O <br />J <br />E <br />E <br />O <br />O <br />U <br />0 <br />U- <br />�� <br />J <br />Q <br />N <br />U <br />c�� <br />w U 06 0 <br />U <br />�-Y <br />L �ma�n <br />� Lu <br />J <br />0 mleNa. <br />w uj <br />a <br />v� <br />00 <br />3 <br />N <br />0 <br />u.i <br />O <br />w <br />a <br />w <br />w <br />0 <br />v <br />� <br />w <br />w <br />z <br />z <br />R <br />z <br />m <br />z <br />o <br />� <br />N <br />0 <br />� <br />$ <br />a <br />w <br />U <br />w <br />uwi <br />o <br />z <br />3' <br />� <br />z <br />w <br />z <br />w <br />^ I <br />NI <br />I <br />�I <br />�1 <br />1 <br />Q <br />I <br />N <br />N <br />N <br />N <br />N <br />N <br />Z <br />H <br />�tM�ppp <br />N <br />w <br />��aVV� <br />O <br />WY0 <br />C� <br />= <br />E101 <br />Scale 1l8"=1'-0" <br />