List of Abbreviations <br />A A/C <br />AIR CONDITION <br />E <br />EL <br />ELEVATION <br />AB <br />ANCHOR BOLT <br />ELEC <br />ELECTRICAL <br />ACT <br />ACOUSTICAL CEILING TILE <br />ELEV <br />ELEVATOR <br />AD <br />ADJUSTABLE, ADJACENT <br />EMER <br />EMERGENCY <br />AFF <br />ABOVE REF FINISHED <br />EQ <br />EQUAL <br />FLOOR (SLAB) <br />EQUIP <br />EQUIPMENT <br />AHU <br />AIR HANDLER UNIT <br />ESC <br />ESCALATOR <br />ALT <br />ALTERNATE <br />EWC <br />ELECTRIC <br />ALUM <br />ALUMINUM <br />WATER COOLER <br />ANOD <br />ANODIZED <br />EXIST <br />EXISTING <br />APPROX APPROXIMATE <br />EXP <br />EXPANSION <br />ARCH <br />ARCHITECT <br />EXT <br />EXTERIOR <br />AUTO <br />AUTOMATIC <br />F <br />FACP <br />FIRE ALARM <br />B B 0 <br />BOTTOM OF <br />CONTROL PANEL <br />BD <br />BOARD <br />FD <br />FLOOR DRAIN <br />BLDG <br />BUILDING <br />FDN <br />FOUNDATION <br />BM <br />BEAM <br />FIN <br />FINISHED <br />BRG <br />BEARING <br />FLR <br />FLOOR <br />BTM <br />BOTTOM <br />FIR <br />FIRE RESISTANT <br />BUR <br />BUILT UP ROOF <br />FR-S <br />FIRE -RETARDANT <br />WOOD TREATMENT <br />C CB <br />CATCH BASIN <br />FT <br />FEET, FOOT <br />CG <br />CORNER GUARD <br />FTG <br />FOOTING <br />CI <br />CAST IRON <br />FURR <br />FURRING <br />CJ <br />CONTROL JOINT <br />FUT <br />FUTURE <br />CL <br />CENTER LINE <br />CLG <br />CEILING <br />G <br />GA <br />GAUGE <br />CLO <br />CLOSET <br />GAL <br />GALLON <br />CLR <br />CLEAR <br />GALV <br />GALVANIZED <br />CMU <br />CONCRETE <br />GB <br />GRAB BAR <br />MASONRY UNIT <br />GC <br />GENERAL CONTRACTOR <br />CO <br />CLEAN OUT <br />GYP <br />GYPSUM <br />COL <br />COLUMN <br />CONC <br />CONCRETE <br />H <br />HB <br />HOSE BIBB <br />CONST <br />CONSTRUCTION <br />HC <br />HOLLOW CORE <br />CONT <br />CONTINUOUS <br />HDW <br />HARDWARE <br />CONTR <br />CONTRACTOR <br />HM <br />HOLLOW METAL <br />CORR <br />CORRIDOR <br />HORIZ <br />HORIZONTAL <br />CT <br />CERAMIC TILE <br />HR <br />HOUR <br />CTR <br />CENTER <br />HT <br />HEIGHT <br />CU <br />CONDENSING UNIT <br />HTG <br />HEATING <br />CW <br />COLD WATER <br />HVAC <br />HEATING, VENTILATING <br />& AIR CONDITIONING <br />D DBL <br />DOUBLE <br />HW <br />HOT WATER <br />DEPT <br />DEPARTMENT <br />DET <br />DETAIL <br />I <br />ID <br />INSIDE DIAMETER <br />DF <br />DRINKING FOUNTAIN <br />IN <br />INCH <br />DIA <br />DIAMETER <br />INCL <br />INCLUDING <br />DIM <br />DIMENSION <br />INSUL <br />INSULATION <br />DISP <br />DISPENSER <br />INT <br />INTERIOR <br />DN <br />DOWN <br />INV <br />INVERT <br />DS <br />DOWNSPOUT <br />DWG <br />DRAWING <br />J <br />JAN <br />JANITOR <br />E <br />JB <br />JUNCTION BOX <br />EA <br />EACH <br />JT <br />JOINT <br />EB <br />EXPANSION BOLT <br />EIFS <br />EXTERIOR INSULATING' <br />L <br />L <br />LENGTH <br />FINISH SYSTEM <br />LAM <br />LAMINATE <br />EJ <br />EXPANSION JOINT <br />L LAV <br />LAVATORY <br />LBL <br />LABEL <br />LBS <br />POUNDS <br />LF <br />LINEAR FEET <br />LT WT <br />LIGHT WEIGHT <br />M MAS <br />MASONRY <br />MAX <br />MAXIMUM <br />MECH <br />MECHANICAL <br />MFR <br />MANUFACTURER <br />MH <br />MANHOLE <br />MIN <br />MINIMUM <br />MIN <br />MINIMUM, MINUTE <br />MISC <br />MISCELLANEOUS <br />MLDG <br />MOLDING <br />MO <br />MASONRY OPENING <br />MR <br />MOISTURE RESISTANT <br />MTD <br />MOUNTED <br />MTL <br />METAL <br />MUL <br />MULLION <br />N NIC <br />NOT IN CONTRACT <br />NOM <br />NOMINAL <br />NTS <br />NOT TO SCALE <br />0 OC <br />ON CENTER <br />OD <br />OUTSIDE DIAMETER <br />OPP <br />OPPOSITE <br />OVFL <br />OVERFLOW <br />P PL <br />PLATE <br />PLAM <br />PLASTIC LAMINATE <br />PLAS <br />PLASTER <br />PLBG <br />PLUMBING <br />PLWD <br />PLYWOOD <br />PNL <br />PANEL <br />PR <br />PAIR <br />PREFAB <br />PREFABRICATED <br />PT <br />POINT <br />PT <br />PRESSURE TREATED <br />PTD <br />PAPER TOWEL DISPENSER <br />PVC <br />POLY VINYL CLORIDE <br />Q QT <br />QUARRY TILE <br />R R <br />RADIUS, RISER, <br />THERMAL RESISTANCE <br />RD <br />ROOF DRAIN <br />RECP <br />RECEPTACLE <br />REF <br />REFERENCE <br />REFR <br />REFRIGERATOR <br />REG <br />REGLET <br />REINF <br />REINFORCEMENT <br />REQ <br />REQUIRED <br />REV <br />REVISION <br />RM <br />ROOM <br />RND <br />ROUND <br />RO <br />ROUGH OPENING <br />RTU <br />ROOF TOP UNIT <br />S <br />SC <br />SOLID CORE <br />SCHED <br />SCHEDULE <br />SCP <br />SCUPPER <br />SD <br />SOAP DISPENSER <br />SEAL <br />SEALANT <br />SECT <br />SECTION <br />SF <br />SQUARE FEET <br />SHT <br />SHEET <br />SIM <br />SIMILAR <br />SPEC <br />SPECIFICATION <br />SS <br />STAINLESS STEEL, <br />SERVICE SINK <br />STD <br />STANDARD <br />STL <br />STEEL <br />STOR <br />STORAGE <br />STRUC <br />STRUCTURAL <br />SUSP <br />SUSPENDED <br />SY <br />SQUARE YARD <br />T <br />T <br />TREAD <br />T&G <br />TONGUE & GROOVE <br />TBL <br />TABLE <br />TELE <br />TELEPHONE <br />TEMP <br />TEMPERED <br />THK <br />THICK <br />TLT <br />TOILET <br />TO <br />TOP OF <br />TPD <br />TOILET PAPER <br />DISPENSER <br />TS <br />TUBE STEEL <br />TV <br />TELEVISION <br />TYP <br />TYPICAL <br />U <br />UON <br />UNLESS OTHER- <br />WISE NOTED <br />UTIL <br />UTILITY <br />V <br />VB <br />VINYL BASE <br />VCT <br />VINYL COMPOSITE TILE <br />VERT <br />VERTICAL <br />VEST <br />VESTIBULE <br />VIF <br />VERIFY IN FIELD <br />VTR <br />VENT THRU ROOF <br />VWC <br />VINYL WALL COVERING <br />W <br />W <br />WIDTH <br />W/ <br />WITH <br />W/O <br />WITHOUT <br />WC <br />WATER CLOSET <br />WD <br />WOOD <br />WH <br />WATER HEATER <br />WP <br />WATERPROOF <br />WT <br />WEIGHT <br />WWF <br />WELDED WIRE FABRIC <br />WWM <br />WELDED WIRE METAL <br />Y <br />YD <br />YARD <br />ax - -- GRID DESIGNATION Z� BUILDING SECTION <br />A301-2 A301-2 <br />102 ROOM NUMBER SHEET NUMBER - SECTION NUMBER <br />CO2 DOOR NUMBER u WALL SECTION <br />A302-3-3 <br />a SHEET NUMBER -� �- - SECTION NUMBER <br />ti) WINDOW TYPE <br />02 STOREFRONTTYPE A501-6 SECTION DETAIL <br />� WALLTYPE SHEET' NUMBER DETAIL. NUMBER <br />CD <br />KEY. NOTE A888-88) DETAIL. REFERENCE <br />_T _1/ <br />SHEET NUMBER DETAIL NUMBER <br />NUMBER 16 <br />T 0 SOMETHING C? EXTERIOR XX' XX'° ELEVATIONS TAGS / C? EXTERIOR ELEVATION <br />A201-2 MARKERS <br />� SHEET NUMBER ELEVATION NUMBER <br />SPOT ELEVATION TAG <br />� 1 <br />n <br />4 ` A401 2 INTERIOR ELEVATION <br />A <br />%� \ MARKERS <br />I `J NORTH ARROW / _ <br />SHEET NUMBER - /'`��' ELEVATION NUMBER <br />r <br />/ BRICK . " ° , ° . CONCRETE �� PLYWOOD __--L_-L/ <br />I MASONRYCOMPACTED <br />EARTH -� <br />enriots <br />1. ALL WORK WILL COMPLY WITH LOCAL, STATE, AND NATIONAL CODES <br />RELATED TO THIS PROJECT. <br />2. THE WRITTEN DIMENSIONS PREVAIL ON THE CONSTRUCTION DOCUMENTS, <br />DO NOT SCALE THESE DRAWINGS. CONTRACTOR TO VERIFY ALL DIMENSIONS <br />AND CONDITIONS IN THE FIELD. IF ANY DISCREPANCY OCCURS, THE <br />CONTRACTOR IS REQUIRED TO NOTIFY THE ARCHITECT IN WRITING BEFORE <br />PROCEEDING WITH ANY WORK AFFECTED BY THE DISCREPANCY. <br />3. CONTRACTORS TO SECURE ALL PERMITS AND REQUIRED INSPECTIONS <br />NECESSARY TO OBTAIN A CERIFICATE OF OCCUPANCY. <br />4. CONTRACTORS ARE TO PROVIDE ALL TEMPORARY UTILITIES AND <br />INFRASTRUCTURE REQUIRED TO PERFORM THE WORK, INCLUDING <br />FIRE PROTECTION AS REQUIRED DURING CONSTRUCTION. <br />5. EACH CONTRACTOR AND SUBCONTRACTOR IS EXPECTED TO REVIEW ALL <br />CONTRACT DOCUMENTS AND SITE CONDITIONS PRIOR TO ISSUED BID. <br />CHANGE ORDERS WILL NOT BE APPROVED FOR FAILURE TO DO SO. <br />6. PRODUCTS SPECIFIED OR OTHERWISE INDICATED IN THE CONTRACT <br />DOCUMENTS SHALL NOT BE SUBSTITUED WITHOUT PRIOR WRITTEN <br />APPROVAL FROM THE ARCHITECT. <br />7. THIS CONTRACTOR SHALL COORDINATE ALL TRADES REQUIRED TO <br />COMPLETE THIS PROJECT AS REQUIRED TO ACTIVATE THE USE OF THE <br />FACILITY AS PLANNED. <br />GYPSUM <br />BOARD <br />----I RIGID <br />I- <br />L 'INSULATION <br />D DRAINAGE <br />p t FILL <br />:....... <br />MR <br />BOARD <br />8. THE CONTRACTOR SHALL HAVE INSTALLATION INSTRUCTIONS FOR ALL <br />EQUIPMENT AND APPLIANCES ON SITE AT TIME OF INSPECTION. <br />9. THIS BUILDING SHALL BE FULLY SPRINKLERED. CONTRACTOR TO SUBMIT SIGNED AND <br />SEALED SHOP DRAWINGS AND HYDRAULIC CALCULATIONS TO THE ARCHITECT FOR <br />REVIEW AS WELL AS LOCAL_ JURISDICTION FOR PERMITTING. NO CONSTRUCTION OF THE <br />FIRE PROTECTION SYSTEM SHALL TAKE PLACE UNTIL THE APPROPRIATE PERMITS ARE <br />OBTAINED BY THE FIRE PROTECTION SUB CONTRACTOR <br />10. CONTRACTOR SHALL PROVIDE FLORIDA PRODUCT APPROVAL SUBMITTALS FOR THE <br />FOLLOWING BUILDING COMPONENTS THAT COMPLY WITH RULE 9B-72: <br />a. EXTERIOR HOLLOW METAL DOORS <br />b. STORE FRONT SYSTEMS (WIND VELOCITY =110 MPH) <br />c. ROOFING AND COPING (CONFIRMING TO FM 1-120 REQUIREMENTS) <br />d. CLADDINGS (LAPPED SIDING) <br />LCONTRACTOR TO PROVIDE THREE COPIES FOR REVIEW AND SUBMITTAL TO <br />THE LOCAL JURISDICTION AND PRODUCT SUBMITTAL FOR ARCHITECTS <br />REVIEW. <br />11. ALL PLYWOOD SHEATHING TO BE FIRE RETARDANT TREATED (FRT) <br />12. SEE "PUBLIX CANOPY PACKAGE" DRAWINGS FOR DETAILS KEYED WITH PREFEX "PCA2 <br />13. SEE STRUCTRUAL DRAWINGS FOR SOILS REPORT INFORMATION <br />14. SEE ENERGY CALCULATION ATTACHED TO THIS SUBMISSION <br />Legal Description <br />A TRACT OF LAND LYING IN THE NORTHEAST Y4 OF SECTION 34 AND IN THE NORTHWEST %4 OF SECTION <br />35, TOWNSHIP 25 SOUTH, RANGE 21 EAST, PASCO COUNTY, FLORIDA. THE SAME BEING A PORTION OF <br />THE ZEPHYRHILLS COLONY COMPANT LANDS SUBDIVISION OF SAID SECTION 34 AND 35 AS SHOWN <br />ON THE PLAT OR MAP THEREOF RECORDED IN PLAT BOOK 1, PAGE 55 OF THE PUBLIC RECORDS OF <br />PASCO COUNTY, FLORIDA. ALL BEING FURTHER DESCRIBED AS FOLLOWS: FOR A POINT OF <br />REFERENCE COMMENCE AT THE SOUTHEAST CORNER OF THE NORTHWEST Y4 OF SAID SECTION 35; <br />THENCE N. 89 53'13"W., ALONG THE SOUTH BOUNDARY THEREOF, A DISTANCE OF 1638.79 FEET; <br />THENCE N. 00 09'45" W., A DISTANCE OF 657.26 FEET TO THE INTERSECTION OF THE EASTERLY <br />RIGHT-OF-WAY LINE OF U.S. HIGHWAY 301; THENCE NORTHERLY, ALONG SAID EASTERLY <br />RIGHT-OF-WAY LINE, THE FOLLOWING FOUR COURSES; (2) S. 89 4632" E., A DISTANCE OF 5.00 FEET; (4) <br />NORHTERLY, 625.74 FEET ALONG THE ARC OF A CURVE TO THE RIGHT (SAID CURVE HAVING A <br />RADIUS OF 625.73 FEET) TO A POINT LYING ON THE NORTH BOUNDARY OF SAID SECTION 34; THENCE <br />S. 89 58'32" SECTION 34 ALSO BEING THE NORTHWEST CORNER OF SAID SECTION 35; THENCE S. 89 <br />59'50" E., ALONG THE NORTH BOUNDARY OF SAID SECTION 35, A DISTANCE OF 1015.05 FEET; THENCE <br />S. 00 09'45" W., A DISTANCE OF 2618.58 FEET TO THE POINT OF BEGINNING. <br />LESS AND EXCEPT THAT PORTION OF SAID TRACTS 58 AND 59 CONVEYED IN OFFICIAL RECORDS <br />BOOK 1902, PAGE 690, PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. <br />SAID LAND CONTAINING 60.76 ACRES MORE OR LESS. <br />Vicinity Map " L�') <br />INTERSECTION OF KOSSIK & US HWY 301 (GALL BLVD) <br />ZEPHYR COMMONS CONSISTS OF NEW SITE CONSTRUCTION AND THE NEW CONSTRUCTION OF SEVERAL <br />BUILDINGS, THE SCOPE OF WORK IN THIS SET OF DRAWINGS IS FOR RETAIL BUILDING C ONLY. THE SITE <br />WORK AND THE OTHER, BUILDINGS WILL BE DESIGNED, PERMITTED, AND CONSTRUCTED AS SEPARATE <br />DRAWING PACKAGES. <br />THIS SCOPE OF WORD IS FOR NEW CONSTRUCTION OF A SHELL BUILDING (SINGLE STORY MASONRY, <br />MERCANTILE OCCUPANCY, SPRINKLERED STRUCTURE). TENANT DEMISING WALLS, TOILETS, CEILINGS, HVAC <br />& LIGHTING TO BE PERMITTED SEPARATELY DURING TENANT FIT UP SUBMISSION, THE BUILDING SHELL. IS <br />SUBMITTED AS AN UNOCCUPIED BUILDING.. <br />uode Information <br />REFER TO A102 FOR COMPLETE CODE. INFORMATION <br />CITY OF ZEPHYRHIIA.S THREE (3) SIGNED & SEALED <br />5335 8TH ST SETS FOR PERMIT SUBMISSION <br />ZEPHYRHILLS, FLORIDA 33542 <br />(813) 780-0020 - PHONE <br />(813) 780-0021 - FAX <br />BUILDING: FLORIDA BUILDING CODE, BUILDING - 2004 W/ 2006 SUPPLEMENTALS] <br />FIRE: FLORIDA FIRE PREVENTION CODE - 2004 W/ 2006 SUPPLEMENTALS <br />CHAPTER 36 - (NFPA 1 & NFPA 101 W/ STATE FIRE MARSHAL AMENDMENTS) <br />PLUMBING: FLORIDA BUILDING CODE, PLUMBING - 2004 W/ 2006 SUPPLEMENTALS <br />MECHANICAL: FLORIDA BUILDING CODE, MECHANICAL. - 2004 W/ 2006 SUPPLEMENTALS <br />ELECTRICAL: FLORIDA BUILDING CODE, BUILDING - 2004 W/ 2006 SUPPLEMENTALS <br />CHAPTER 27 .- (NFPA 70, NATIONAL ELECTRIC CODE) <br />FUELIGAS: FLORIDA BUILDING CODE, FUEL/GAS - 2004 W/ 2006 SUPPLEMENTALS <br />ACCESSIBILITY: FLORIDA BUILDING CODE, BUILDING - 2004 W/ 2006 SUPPLEMENTALS <br />CHAPTER 11 - (FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION). <br />ENERGY: FLORIDA BUILDING CODE, BUILDING - 2004 WI 2006 SUPPLEMENTALS <br />CHAPTER 13 - (FLORIDA ENERGY EFFICIENCY FOR BUILDING CONSTRUCTION). <br />BUILDING AND CONSTRUCTION DATA <br />OCCUPANCY CLASSIFICATION (FBC 309) GROUPS M - MERCANTILE <br />CONSTRUCTION TYPE (FBC 1-ABLE 601) TYPE II-B, NEW CONSTRUCTION, <br />SPRINKLERED <br />MAXIMUM HEIGHT AND AREA (FBC TABLE 503) HEIGHT - 55'-0" AREA-12,500 SF* <br />��1 - v ' ' WQLE STORY) <br />ACTUAL AREA = 18,375 SF <br />*THE PUBL.IX AND ADJACENT RETAIL BUILDINGS ARE <br />CLASSIFIED AS UNLIMITED AREA AS ALLOWED BY FBC 507 <br />CLIENT: PRIMERICA GROUP ONE, INC. <br />3629 MARACA LANE <br />TAMPA, FL. 33618 <br />(813) 933-0629 PHONE <br />(813) 935-3420 FAX <br />CONTACT: LARRY GARREN <br />ARCHITECT: CUHACI & PETERSON, ARCHITECTS, LLC <br />1925 PROSPECT AVE <br />ORLANDO, FL 32814 <br />(407) 661-9100 PHONE <br />(407) 661-9101 FAX <br />CONTACT: GABRIEL ROBERTSON <br />CIVIL AVID GROUP <br />ENGINEER: 8659 BAYPINE ROAD, STE 304 <br />JACKSONVILLE, FLORIDA 32256 <br />(904) 737-4001 PHONE <br />(904) 252-7030 FAX <br />CONTACT: TAMARA D. SCHURIAN, P.E. <br />STRUCTURAL CUHACI & PETERSON, ARCHITECTS, LLC <br />ENGINEER: 1925 PROSPECT AVE <br />ORLANDO, FL 32814 <br />(407) 661-9100 PHONE <br />(407) 661-9101 FAX <br />CONTACT: BRETT RYLANDS <br />MECHANICAL CUHACI & PETERSON, ARCHITECTS, LLC <br />ENGINEER: 1925 PROSPECTAVE <br />ORLANDO, FL 32814 <br />(407) 661-9100 PHONE <br />(407) 661-9101 FAX <br />CONTACT: JOE KEENE <br />ELECTRICAL CUHACI & PETERSON, ARCHITECTS, LLC <br />ENGINEER: 1925 PROSPECT AVE <br />ORLANDO, FL 32814 <br />(407) 661-9100 PHONE <br />(407) 661-9101 FAX <br />CONTACT: TIM CONWAY <br />Gall Blvd. & Kossik Road <br />Zeiphvrhiiis., Florida <br />Retail C <br />APPROVED <br />by'Fire Marshal of Ze-phyr 'As <br />With c ents provided'y�,'itah pi ns),47 <br />T S'i <br />:�� ✓TOFF' SHILL CQa r r lxr!T a AL <br />t t: L <br />�VAII I dG CODES, FT O?�IDA EUILM,, s <br />CODE "dI TIOiVkL ELECTRIC CODEAN <br />C .!7 OF L EPffYRHF1LLS ORDENTANCES <br />�- — -- Drawing Index —------------ � <br />F�ET 0, ONT9TLE � SHEET 20080 _�Q7 ---�2008_05-02____ <br />PERMIT BID SET <br />ARCHITECTURAL <br />COVER <br />T-1 - <br />A100 <br />A101 <br />A102 <br />A103 <br />A104 <br />A105 <br />A201 <br />A301 <br />A302 <br />A303 <br />A501 <br />A502 <br />A601 <br />A001-AO08 _ <br />STRUCTURAL <br />COVER SHEET <br />ARCHITECTURAL GENERAL_ NOTES __ __•-______•i <br />OVERALL PROJECT SITE PLAN <br />SIDEWALK PLAN <br />LIFE SAFETY PLAN _ <br />FLOOR PLAN <br />REFLECTED CEILING PLAN <br />ROOF PLAN <br />ELEVATIONS <br />SECTIONS <br />SECTIONS <br />SECTIONS <br />DETAILS <br />DETAILS <br />DOOR SCHEDULES & DE:TA_II_S t�TTAEI__ES SNF�T A_5�-__- <br />SPECIFICATIONS �- <br />GENERALNOTES <br />MASONRY GENERAL INFORMATION <br />PRECAST LINTEL GENERAL INFORMATION <br />JOIST AND GIRDER GENERAL INFORMATION <br />METAL DECK GENERAL INFORMATION <br />_ <br />FOUNDATIQN PLAN�— <br />FRAMING PLAN <br />ROOF FRAMING PLAN <br />FRAMING PLAY_.__ <br />WALL SECTIONS <br />WALL SECTIONS <br />- <br />WALL SECTIONS <br />FOUNDATION DETAILS <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />0 <br />0 <br />e <br />9 <br />0 <br />2008_05-27 <br />OWNER REVISION <br />0 <br />0 <br />0 <br />FIRE PROTECTION (SEE GENERAL NOTE #9 <br />FPOQ1 _ FIRE PROTECTION FLOOR PLAN & GENERAL INFORMATION -� X X E_ <br />PLUMBING _ _ <br />�P001 PLUMBING FLOOR PLAN, NOTES, & DETAILS X� X L- X ---�-� __ <br />MECHANICAL _ __ _ <br />rM001 ----�[MECHANICAL FLOOR PLAN, NOTES, CHEDULES & DETAILS] I--- X = C X--- X -� r---------�� --� <br />ELECTRICAL <br />ELECTRICAL FLOOR PLAN - BUILDING C X X X <br />ELECTRICAL POWER RISER & DETAIL - BUILDING C X X X _ <br />ELECTRICAL SPECIFICATIONS - BUILDING C X X <br />E101 <br />E301 <br />E501 <br />�E <br />V <br />CO o <br />d CD <br />z <br />JCD <br />oC:) <br />x <br />W <br />Q - <br />`J <br />� o <br />v <br />w� <br />aCP <br />� <br />C <br />�� <br />ti <br />0 <br />