ABBREVIATIONS (IN ADDITION TO COVERSHEET ABBREV.) <br />(ABBREVIATIONS <br />SHOWN ARE NOT NECESSARILY USED ON <br />THE DRAWINGS) <br />A <br />L <br />AB <br />ANCHOR BOLT <br />LB <br />POUNDS <br />A/C <br />AIR CONDITIONING <br />L.F. <br />LINEAR FEET <br />AC <br />ALTERNATING CURRENT <br />LL <br />LIVE LOAD <br />ACI <br />AMERICAN CONCRETE INSTITUTE <br />LLH <br />LONG LEG HORIZONTAL <br />ADJ <br />ADJUSTABLE <br />LLV <br />LONG LEG VERTICAL <br />AIC <br />AMPHERE INTERRUPTING CURRENT <br />LONG <br />LONGITUDINAL <br />AFF <br />ABOVE FINISHED FLOOR <br />LRA <br />LOCK MOTOR AMPS <br />ALUM. <br />ALUMINUM <br />LT <br />LIGHT <br />AMP <br />AMPERE, AMPS <br />LP <br />LOW POINT <br />ARCH. <br />ARCHITECT, ARCHITECTURAL <br />LTG <br />LIGHTING <br />ASHRAE <br />AMERICAN SOCIETY OF HEATING, <br />LWC <br />LIGHT WEIGHT CONCRETE <br />REFRIGERATION AND AIR <br />L. L. <br />LANDLORD <br />CONDITIONING ENGINEERS <br />ASTM <br />AMERICAN SOCIETY OF TESTING AND <br />MATERIALS <br />AVG <br />AVERAGE <br />AWG <br />AMERICAN WIRE GAUGE <br />MAX <br />MAXIMUM <br />MCA <br />MINIMUM CIRCUIT AMPACITY <br />B <br />MCB <br />MAIN CIRCUIT BREAKER <br />MDP <br />MAIN DISTRIBUTION PANEL <br />MECH <br />MECHANICAL <br />MFR <br />MANUFACTURER <br />BC <br />BUILDING CONTRACTOR <br />MH <br />MANHOLE, METAL HALIDE <br />BLDG <br />BUILDING <br />MIN <br />MINIMUM <br />BM <br />BEAM <br />MLO <br />MAIN LUGS ONLY <br />BOTT. <br />BOTTOM <br />MSB <br />MAIN SWITCHBOARD <br />BTU <br />BRITISH THERMAL UNIT <br />MTD <br />MOUNTED <br />c <br />N <br />C <br />CONDUIT <br />N/A <br />NOT APPLICABLE <br />C.F. <br />CUBIC FEET <br />NEC <br />NATIONAL ELECTRICAL CODE <br />CFM <br />CUBIC FEET PER MINUTE <br />NEMA <br />NATIONAL ELECTRICAL <br />CKT <br />CIRCUIT <br />MANUFACTURER'S ASSOCIATION <br />CENTERLINE <br />NF <br />NEAR FACE <br />CLG <br />CEILING <br />NFPA <br />NATIONAL FIRE PROTECTION <br />CLR <br />CLEAR OR CLEARANCE <br />ASSOCIATION <br />CMU <br />CONCRETE MASONRY UNIT <br />N.I.C. <br />NOT IN CONTRACT <br />CO <br />CLEANOUT <br />NL <br />NIGHT LIGHT <br />COL. <br />COLUMN <br />NO. <br />NUMBER <br />CONC. <br />CONCRETE, CONCENTRIC <br />NOM <br />NOMINAL <br />CONT. <br />CONTINUOUS, CONTINUATION <br />NTS <br />NOT TO SCALE <br />COORD. <br />COORDINATE <br />CR <br />CONDENSATE RETURN <br />CJ <br />CONSTRUCTION JOINT <br />O <br />CTR <br />CENTER <br />CV <br />CHECK VALVE <br />CUH <br />CEILING UNIT HEATER <br />OA <br />OUTSIDE AIR <br />CW <br />COLD WATER <br />OC <br />ON CENTER <br />OF <br />OUTSIDE FACE <br />OD <br />OUTSIDE DIAMETER <br />D <br />OH <br />OPPOSITE HAND <br />OPNG <br />OPENING <br />OSHA <br />OCCUPATIONAL SAFETY AND <br />DC <br />DIRECT CURRENT <br />HEALTH ADMINISTRATION <br />DL <br />DEADLOAD <br />DEG <br />DEGREES <br />P-0 <br />DTL <br />DETAIL <br />DIA OR 0 <br />DIAMETER <br />DIM. <br />DIMENSION <br />DN <br />DOWN <br />PAR <br />PARALLEL <br />DBL <br />DOUBLE <br />P/C <br />PRECAST CONCRETE <br />DS <br />DOWNSPOUT <br />PC <br />PIECE <br />DWG <br />DRAWING <br />PDU <br />POWER DISTRIBUTION UNIT <br />PERP <br />PERPENDICULAR <br />PH,O <br />PHASE <br />PT <br />PAI NT <br />P L <br />PLATE <br />PLBG <br />PLUMBING <br />PNL <br />PANEL <br />EA <br />EACH <br />PIV <br />POST INDICATOR VALVE <br />EC <br />ELECTRICAL CONTRACTOR <br />PSF <br />POUNDS PER SQUARE FOOT <br />EF <br />EXHAUST FAN <br />PVC <br />POLYVINYL CHLORIDE <br />E.J. <br />EXPANSION JOINT <br />EL. <br />ELEVATION <br />QTY. <br />QUANTITY <br />ELEC. <br />ELECTRICAL <br />EMP. <br />EMS <br />EMPLOYEE <br />ENERGY MANAGEMENT SYSTEM <br />ENCL. <br />ENCLOSURE <br />ENT. <br />ENTRY, ENTRANCE <br />EQ. <br />EQUAL <br />EW <br />EACH WAY <br />RA <br />RETURN AIR <br />EXP <br />EXPANSION <br />RAD <br />RADIUS <br />EQUIP <br />EQUIPMENT <br />RCP <br />REFLECTED CEILING PLAN, <br />EWC <br />ELECTRIC WATER COOLER <br />RD <br />ROOF DRAIN <br />EWH <br />ELECTRIC WATER HEATER <br />RE: <br />REFERENCE, REFER <br />EXH <br />EXHAUST <br />REINF. <br />REINFORCING <br />EXIST. <br />EXISTING <br />REQD <br />REQUIRED <br />EXT. <br />EXTERNAL, EXTERIOR <br />RLA <br />RUNNING LOAD AMPS <br />RM <br />ROOM <br />RPM <br />RTU <br />REVOLUTIONS PER MINUTE <br />ROOFTOP UNIT <br />FA <br />FIRE ALARM <br />FACP <br />FIRE ALARM CONTROL PANEL <br />FCO <br />FLOOR CLEANOUT <br />SC <br />SITE CONTRACTOR <br />FD <br />FIN <br />FIRE DAMPER, FLOOR DRAIN <br />FINISH (ED) <br />SCHED. <br />SCHEDULED <br />FIXT. <br />FIXTURE <br />SCHR <br />SECONDARY CHILLED WATER RETURN <br />FDN <br />FOUNDATION <br />SD <br />SMOKE DAMPER, STORM DRAIN <br />FLG <br />FLANGE <br />SECT. <br />SECTION <br />FTG <br />FOOTING <br />S <br />S.F. <br />SENSOR <br />SQUARE FEET <br />FS <br />FAR SIDE <br />SHT <br />SHEET <br />F.F. <br />FINISHED FLOOR <br />SIM <br />SIMILAR <br />FLR <br />FLOOR <br />SHT. MTL. <br />SHEET METAL <br />FLUOR. <br />FLUORESCENT <br />SPEC. <br />SPECIFICATION <br />FRP <br />FIBERGLASS REINFORCED PANEL_ <br />SQ. <br />SQUARE <br />FT. <br />FOOT, FEET <br />SS <br />STAINLESS STEEL, SANITARY SEWER <br />STC <br />SOUND TRANSMISSION CLASS <br />STD. <br />STANDARD <br />STL. <br />STEEL <br />STIFF <br />STIFFENER <br />STIR. <br />STIRRUPS <br />GA. <br />GAUGE <br />SUSP. <br />SUSPENDED <br />GALV. <br />GALVANIZED <br />SYMM <br />SYMMETRICAL <br />GB <br />GRADE BEAM <br />GC <br />GENERAL CONTRACTOR <br />GFI <br />GROUND FAULT CIRCUIT INTERRUPTER <br />GND <br />GROUND-� <br />GWB <br />GYPSUM WALL BOARD <br />T&B <br />TOP AND BOTTOM <br />TEF <br />TOILET EXHAUST FAN <br />T/FTG <br />TOP OF FOOTING <br />THICK <br />THICKNESS <br />TOJ <br />TOP OF JOIST <br />HGT <br />HEIGHT <br />TOS <br />TOP OF STEEL <br />HID <br />HIGH INTENSITY DISCHARGE <br />THRU <br />T <br />THROUGH <br />THERMOSTAT <br />HORIZ. <br />HORIZONTAL <br />TYP <br />TYPICAL <br />HP <br />HORSEPOWER <br />TS <br />TEMPERATURE SENSOR <br />HTR <br />HEATER <br />HVAC <br />HEATING, VENTILATING AND AIR <br />CONDITIONING <br />U-V <br />HVU <br />HEATING AND VENTILATING UNIT <br />H VY <br />HEAVY <br />- <br />-- <br />UL <br />UNDERWRITERS LABORATORIES, INC. <br />U.O.N. <br />UNLESS OTHERWISE NOTED <br />UPS <br />UNINTERRUPTIBLE POWER SUPPLY <br />V <br />VOLT <br />1. D. <br />INSIDE DIAMETER <br />VA <br />VOLT-AMPERE <br />I.E. <br />INVERT ELEVATION <br />VERT, <br />VERTICAL <br />IG <br />ISOLATED GROUND <br />VTR <br />VENT THROUGH ROOF <br />I NT. <br />INTERIOR <br />INTER <br />IN. <br />INTERMEDIATE <br />INCH,INCHESw_x_y_z <br />INSUL. <br />INSULATION <br />W <br />WATT <br />W/ <br />WITH <br />W/0 <br />WITHOUT <br />WCO <br />WALL CLEAN OUT <br />J-BOX <br />JUNCTION BOX <br />W.C. <br />WATER CLOSET <br />JT <br />JOINT <br />WL <br />WIND LOAD <br />WP <br />WEATHERPROOF <br />W.O. <br />WWF <br />WALL OPENING <br />WELDED WIRE FABRIC <br />XFMR <br />TRANSFORMER <br />k <br />KIPS (1000 LBS) <br />YD <br />YARD <br />kCMIL <br />1000 CIRCULAR MILS <br />kV <br />KILOVOLT <br />kVA <br />KILOVOLT -AMPS <br />kW <br />KILOWATT <br />kWH <br />KILOWATT-HOUR <br />m <br />I <br />E <br />FIRE PROTECTION NOTES <br />SEE OUTLINE SPECIFICATION FOR COMPLETE FIRE PROTEC7nON SPECIFICATIONS. <br />15.21.A. <br />FIRE PROTECTION DESIGN FOR THE SITE SPECIFIC, FINAL SPECIFICATION SHALL BE DESIGNED IN COMPLIANCE WITH THE ADOPTED <br />EDITION OF NFPA 13, NFPA 24, THE ADOPTED FIRE CODE AND LOCAL JURISDICTIONAL REQUIREMENTS AND/OR AMENDMENTS TO <br />THE ADOPTED CODES. ALL FIRE PROTECTION SYSTEMS FOR THE ENTIRE RETAIL SALES AND RECEIVING AREAS SHALL MEET THE <br />REQUIREMENTS FOR STORAGE OF COMMODITIES IN SINGLE -ROW AND DOUBLE -ROW RACKS AS WELL AS SOLID SHELF GONDOLA <br />RACKS WHICH HAVE AN OVERALL WIDTH GREATER THAN 30 INCHES AND FOR STORAGE OF COMMODITIES TO A MAXIMUM HEIGHT OF <br />12'-0". <br />15.21.13. <br />THE LANDLORD'S GENERAL CONTRACTOR SHALL PROVIDE A COMPLETE AND FULLY FUNCTIONAL FIRE PROTECTION SYSTEM INCLUDING <br />BUT NOT LIMITED TO ALL MATERIALS AND EQUIPMENT AS NOTED IN PROTOTYPE DOCUMENTS. <br />15.21.C. <br />THE SPRINKLER SYSTEM SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NFPA STANDARDS AND ALL APPLICABLE LOCAL <br />CODES, AND SHALL CONFORM TO THE REGULATIONS AND REQUIREMENTS OF ALL AUTHORITIES HAVING JURISDICTION. <br />15.21.D. <br />THE SPRINKLER SYSTEM FOR THE ENTIRE SALES AND RECEIVING AREAS SHALL BE DESIGNED IN ACCORDANCE WITH NFPA 13 <br />REQUIREMENTS FOR GONDOLA RACK STORAGE GREATER THAN 30 INCHES IN OVERALL WIDTH, WHICH ARE TREATED AS RACKS WITH <br />SOLID SHELVING, IN ADDITION TO SINGLE AND DOUBLE -ROW RACK STORAGE OF CLASS I -IV NON -ENCAPSULATED COMMODITIES TO <br />AN OVERALL HEIGHT OF 12'-0 ADDITIONAL PROVISIONS TO PROTECTING SOLID SHELVING GONDOLA RACK STORAGE MAY BE <br />FOUND IN NFPA 13, 2002 EDITION. WHEN THE 2002 EDITION IS USED FOR DESIGN, SUCH EDITION SHALL BE ADOPTED BY THE <br />AUTHORITY HAVING JURISDICTION OR AN "ALTERNATE MATERIALS AND METHOD" SHALL BE PROPOSED AND SUCH ALTERNATE USE <br />APPROVED BY THE JURISDICITON IN ORDER TO USE THE 2002 EDITION OF NFPA 13 AS DESIGN CRITERIA. AISLE WIDTHS SHALL <br />BE IN ACCORDANCE WITH THE ADOPTED FIRE CODE AND NFPA 13 FOR THE SPRINKLER HEAD UTILIZED IN THE DESIGN. <br />15.21.E. <br />GONDOLA RACKS SHALL UTILIZE SOLID SHELVES TO A HEIGHT OF 10'-0" A.F.F. WITH MAXIMUM STORAGE HEIGHTS NOT EXCEEDING <br />12'-0" AFF. THE SPRINKLER SYSTEM FOR THE OFFICE AREAS SHALL BE DESIGNED IN ACCORDANCE WITH NFPA 13 REQUIREMENTS <br />FOR LIGHT HAZARD OCCUPANCIES. r <br />15.21.F. <br />THE SPRINKLER SYSTEM SHALL BE OF A DESIGN WHICH IS HYDRAULICALLY CALCULATED IN ACCORDANCE WITH NPFA STANDARDS 13 <br />AND 24. THE LANDLORD'S FIRE SPRINKLER CONTRACTOR SHALL VERIFY THE CURRENTLY AVAILABLE WATER SUPPLY, DESIGN THE <br />FIRE PROTECTION IN ACCORDANCE WITH THE CURRENTLY AVAILABLE WATER SUPPLY. THE CONTRACTOR SHALL SUBMIT FINAL <br />SPRINKLER SYSTEM DESIGN DRAWINGS AND HYDRAULIC CALCULATIONS TO THE LOCAL FIRE OFFICIAL OR TO A THIRD PARTY PLAN <br />REVIEWER FOR REVIEW WHEN DIRECTED TO DO SO BY THE AUTHORITY HAVING JURISDICTION. <br />15.22.A. <br />ALL MATERIALS AND DEVICES REQUIRED FOR A COMPLETE AND OPERATIONAL FIRE PROTECTION SYSTEM SHALL BE LISTED AND <br />APPROVED FOR SUCH USE AS REQUIRED BY NFPA STANDARDS 13 AND 24. <br />15.22.13. <br />PIPING JOINTS SHALL BE EITHER WELDED, THREADED, OR GROOVED ACCORDING TO MANUFACTURER'S RECOMMENDATIONS. <br />15.22.C. <br />A SEPARATE ALARM CHECK VALVE IS REQUIRED ON ALL RISER ASSEMBLIES. <br />15.22.D. <br />VALVES FOR SPRINKLER OPERATION SHALL BE THE LISTED, INDICATING TYPE, AS REQUIRED BY NFPA 13 AND/OR NFPA 24. VALVES <br />INSIDE THE BUILDING SHALL BE OUTSIDE -SCREW -AND -YOKE (OS&Y) TYPE OR OF A TYPE MANDATED BY THE AUTHORITY HAVING <br />JURISDICTION. SUCH VALVES SHALL BE NORMALLY IN THE OPEN POSITION, AND SHALL BEAR SUPERVISORY SWITCHES CONNECTED <br />TO AN APPROVED ELECTRONIC SUPERVISORY MONITORING SYSTEM. THE LANDLORD'S GENERAL CONTRACTOR SHALL PROVIDE ALL <br />REQUIRED ELECTRICAL CONNECTIONS FOR ALL COMPONENTS CONNECTED TO THE SUPERVISORY MONITORING SYSTEM. <br />15.22.E. <br />CHECK VALVES AND BACKFLOW PREVENTION ASSEMBLIES SHALL BE OF AN APPROVED TYPE AND BE SHALL BE INSTALLED IN <br />COMPLIANCE WITH LISTING REQUIREMENTS AS REQUIRED BY THE LOCAL AUTHORITY HAVING JURISDICTION. LOCATION OF BACKFLOW <br />ASSEMBLIES SHALL BE APPROVED BY THE AUTHORITY HAVING JURISDICTION. <br />15.22. F. <br />IN AREAS SUBJECT TO FREEZING, BACKFLOW PREVENTION ASSEMBLIES SHALL BE INSTALLED IN LOCATIONS DETERMINED BY THE <br />AUTHORITY HAVING JURISDICTION. THE MAXIMUM DISTANCE ALLOWED FROM A FIRE HYDRANT TO THE FIRE DEPARTMENT CONNECTION <br />SHALL ALSO BE DETERMINED BY THE AUTHORITY HAVING JURISDICTION. <br />15.22.G. <br />ALL OTHER VALVES SHALL BE EITHER BRONZE OR IRON -BODY FLANGED VALVES OR IRON -BODY FLANGED OS&Y GATE VALVES OR <br />AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION. <br />15.22.H. <br />ALL HANGERS SHALL CONFORM TO THE REQUIREMENTS OF NFPA 13. PIPING SHALL BE SUPPORTED AND BRACED FROM THE <br />BUILDING STRUCTURE AS REQUIRED IN NFPA 13 AND TO MAINTAIN REQUIRED ELEVATION AND PITCH OF PIPE, TO PREVENT <br />VIBRATION, ALLOW SEISMIC MOVEMENT AND TO SECURE PIPING IN PLACE. <br />15.22.1. <br />LANDLORD'S GENERAL CONTRACTOR SHALL PROVIDE A TYPE AND NUMBER OF BOXES SUCH AS "KNOX" OR "SUPRA" BRAND KEY <br />STORAGE BOXES AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION AND/OR LOCAL FIRE DEPARTMENT. LOCATION OF KEY <br />BOX(ES) SHALL BE COORDINATED WITH LOCAL JURISDICTION AND STAPLES PROJECT MANAGEMENT TEAM. <br />15.23.A. <br />SPRINKLERS SHALL BE DESIGNED, INSTALLED AND TESTED IN CONFORMANCE WITH NFPA STANDARDS 13 AND 24. <br />15.23.13. <br />SPRINKLERS SHALL BE THE UPRIGHT TYPE IN AREAS WITHOUT SUSPENDED CEILINGS AND SHALL BE OF THE RECESSED PENDANT <br />TYPE IN AREAS WITH SUSPENDED CEILINGS. SPRINKLERS IN SUSPENDED CEILING AREAS SHALL BE LOCATED AS CLOSE TO CENTER <br />OF CEILING TILES AS POSSIBLE. <br />15.23.C. <br />AT PROJECT COMPLETION, THE LANDLORD'S GENERAL CONTRACTOR SHALL ENSURE THAT THE SPRINKLER CONTRACTOR HAS AFFIXED <br />A DESIGN CALCULATION TAG TO THE RISER STATING THE SPRINKLER SYSTEM DESIGN CRITERIA. THE LANDLORD'S GENERAL <br />CONTRACTOR SHALL ALSO ENSURE THAT THE SPRINKLER CONTRACTOR HAS PROVIDED THE NUMBER AND TYPE OF SPARE <br />SPRINKLERS AS REQUIRED IN NFPA 13 AND THE REQUIRED PIPE WRENCH(S) IN A METAL HEAD BOX NEXT TO SPRINKLER RISER. <br />THE LANDLORD'S GENERAL CONTRACTOR SHALL PROVIDE THE METAL SPRINKLER HEAD BOX AT SPRINKLER RISER LOCATION. <br />15.24.A. <br />SPRINKLERS SHALL BE LOCATED AS FOLLOWS: <br />1. IN RETAIL SALES AND STORAGE AREAS, SPRINKLERS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NFPA 13 FOR <br />THE APPROPRIATE HAZARD AND IN ACCORDANCE WITH THE INSIDE CLEAR CEILING HEIGHT AND THE LISTING OF THE SPRINKLER <br />HEAD(S) PROPOSED TO BE INSTALLED. <br />2. IN LIGHT HAZARD AREAS, SPRINKLERS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NFPA 13' FOR THE <br />APPROPRIATE HAZARD AND IN ACCORDANCE: WITH THE CEILING HEIGHT AND LISTING OF THE SPRINKLER HEAD(S) PROPOSED TO BE <br />INSTALLED. <br />15.24.B. <br />SPRINKLER SYSTEM ACCEPTANCE TESTING SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA 13 AND THE <br />JURISDICTIONAL_ AUTHORITIES. SPRINKLER PIPING SHALL BE TESTED AND MADE WATERTIGHT PRIOR TO ANY PAINTING AND/OR <br />CONCEALMENT AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION DURING PROGRESS AND/OR COMPLETION OF WORK. LEAKS <br />SHALL BE IMMEDIATELY REPAIRED. CAULKING IS NOT ALLOWED FOR SPRINKLER SYSTEM LEAK PREVENTION OR REPAIR. <br />15.24.C. <br />THE LANDLORD'S GENERAL CONTRACTOR SHALL NOTIFY STAPLES AND THE LOCAL JURISDICTIONAL AUTHORITIES PRIOR TO ANY FIRE <br />PROTECTION SYSTEM TESTING. <br />15.24.D. <br />SPRINKLER HEADS SHALL BE FREE OF NON -FACTORY APPLIED PAINT AT THE COMPLETION OF THE PROJECT. HEADS DAMAGED BY <br />PAINT DURING CONSTRUCTION SHALL BE REPLACED AT NO COST TO STAPLES. <br />15.24.E. <br />PRIOR TO FINAL COMPLETION, THE LANDLORD'S GENERAL CONTRACTOR SHALL PROVIDE STAPLES WITH THE FOLLOWING: <br />1. A SIGNED COPY OF THE FORM PROVIDED IN NFPA 13 AND NFPA 24 KNOWN AS THE "CONTRACTOR'S MATERIAL AND TEST <br />CERTIFICATE" FOR BOTH THE UNDERGROUND AND THE OVERHEAD FIRE PROTECTION SYSTEMS. THESE FORMS ARE REQUIRED TO BE <br />COMPLETED AND SIGNED BY THE FIRE PROTECTION CONTRACTOR AND SIGNED BY LOCAL JURISDICTIONAL AUTHORITIES WHO HAVE <br />WITNESSED THE TESTING AND FINAL ACCEPTANCE OF THE SYSTEM(S); <br />2. COPIES OF LITERATURE AND INSTRUCTIONS FROM SYSTEM EQUIPMENT MANUFACTURERS DESCRIBING PROPER OPERATION AND <br />MAINTENANCE OF EQUIPMENT, AND A COMPLETED COPY OF NFPA STANDARD 25, "STANDARD FOR THE INSPECTION, TESTING AND <br />MAINTENANCE OF WATER -BASED FIRE PROTECTION SYSTEMS," BOUND IN A THREE-RING BINDER PROPERLY LABELED; AND, <br />3. LANDLORD'S GENERAL CONTRACTOR SHALL PROVIDE TWO (2) COPIES OF THE APPROVED SPRINKLER SYSTEM DESIGN <br />CALCULATIONS AND APPROVED PLANS, BEARING THE STAMPED APPROVAL OF THE AUTHORITY HAVING JURISDICTION. ONE (1) COPY <br />SHALL BE INCLUDED WITH THE AS -BUILT DRAWINGS IN THE PLAN TUBE LOCATED IN THE TELECOM ROOM ,AND ONE (1) COPY <br />PROVIDED WITH PROJECT CLOSEOUT. <br />16.09.A. <br />FIRE ALARM SYSTEM: <br />1. THE ALARM SYSTEM SHALL BE DESIGNED IN ACCORDANCE WITH NFPA 72 AND FURNISHED AND INSTALLED BY THE LANDLORD'S <br />GENERAL CONTRACTOR WHEN REQUIRED TO DO SO BY LOCALLY ADOPTED CODES OR ORDINANCES. THE LANDLORD'S GENERAL <br />CONTRACTOR SHALL PROVIDE THE COMPLETE FIRE ALARM SYSTEM AS SPECIFIED HEREIN. <br />2. FIRE ALARM CONTROL. PANEL: <br />A. THE LANDLORD'S GENERAL CONTRACTOR SHALL PROVIDE A CONTROL PANEL MODULAR IN DESIGN UTILIZING DISTRIBUTED SOLID <br />STATE, FIELD PROGRAMMABLE MICROPROCESSORS WITH CAPABILITY FOR EXPANSION. THE SYSTEM SHALL BE CAPABLE OF <br />n PROVIDING AUTOMATIC. AND MANUAL_ SELF -TESTS. THE SYSTEM SHALL HAVE AN ALPHA -NUMERIC LIQUID CRYSTAL DISPLAY, <br />TOUCHPAD CONTROLS AND LIGHT EMITTING DIODE INDICATORS FOR AC POWER, SYSTEM ALARM AND TROUBLE, AND DISABLE. THE <br />SYSTEM SHALL RECEIVE INFORMATION FROM AND COMMUNICATE CONTINUOUSLY WITH ALL INDICATING DEVICES AND MONITOR <br />MODULES. THE SYSTEM SHALL BE PROVIDED WITH AN INTEGRAL POWER SUPPLY WITH CAPACITY TO POWER THE PANEL_ AND ALL <br />FIRE ALARM PERIPHERALS AND SHALL BE SUPERVISED. <br />B. REMOTE ANNUNCIATOR: AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION OR AS REQUIRED BY THE ADOPTED CODES; THE <br />LANDLORD'S GENERAL CONTRACTOR SHALL PROVIDE A REMOTE ANNUNCIATOR TO REPEAT, INDICATIONS OF THE FIRE ALARM CONTROL <br />PANEL. THE REMOTE ANNUNCIATOR SHALL RECEIVE POWER FROM THE FIRE ALARM CONTROL PANEL. <br />C. PULL STATIONS: AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION OR AS REQUIRED BY THE ADOPTED CODES; THE <br />LANDLORD'S GENERAL CONTRACTOR SHALL PROVIDE NON -BREAK GLASS, DUAL ACTION, KEY RESET, ADDRESSABLE MANUAL PULL <br />STATIONS. <br />D. STROBES AND COMBINATION HORN/STROBES: THE LANDLORD'S GENERAL CONTRACTOR SHALL PROVIDE 24 VDC, 75 CANDELA <br />(MIN) STROBES, 90 DBA HORNS. THE INDICATING DEVICES SHALL SATISFY ALL REQUIREMENTS OF THE AMERICANS' WITH <br />DISABILITIES ACT. <br />E. MONITOR MODULES: THE LANDLORD'S GENERAL CONTRACTOR SHALL PROVIDE MONITOR MODULES WHERE REQUIRED TO <br />INTERFACE WITH CONTACTS TO BE MONITORED INCLUDING BUT NOT LIMITED FLOW AND SUPERVISORY SWITCHES AND DUCT MOUNTED <br />SMOKE DETECTORS WHEN REQUIRED TO BE PROVIDED. THE MODULE SHALL BE CAPABLE OF FIELD ADDRESSING AND TESTING. <br />3. THE LANDLORD'S GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE LOCAL REQUIREMENTS FOR A FIRE <br />ALARM AND OR MONITORING SYSTEM AND SHALL NOTIFY STAPLES' IN WRITING OF SUCH REQUIREMENT AND INDICATE THE SYSTEM <br />DESIGN REQUIREMENTS ON THE CONSTRUCTION DOCUMENTS DURING THE ENGINEERING AND DESIGN PHASE OF THE PROJECT. <br />FIRE PROTECTION NOTES (CONTINUED <br />4. IF LOCAL CODES REQUIRES AN INDEPENDENT AGENCY TO MONITOR THE FIRE ALARM SYSTEM, PROVISIONS ARE REQUIRED TO <br />CONNECT STAPLES' SECURITY SYSTEM TO THE FIRE ALARM SYSTEM IN ADDITION TO THE INDEPENDENT MONITORING AGENCY <br />CONNECTION. <br />5. IF THE LOCAL FIRE CODES REQUIRE A SPECIFIC AGENCY OR TYPE OF (SUCH AS U.L.) CENTRAL STATION TO MONITOR THE FIRE <br />ALARM SYSTEM, STAPLES' SHALL BE NOTIFIED AND SHALL HAVE APPROVAL RIGHTS SELECTING THE MONITORING AGENCY. <br />6. THE LANDLORD'S GENERAL CONTRACTOR SHALL BE REQUIRED TO EXECUTE A CONTRACT WITH THE APPROVED MONITORING <br />AGENCY AS NECESSARY TO OBTAIN THE CERTIFICATE OF OCCUPANCY PRIOR TO DELIVERY OF THE PREMISES. THE LANDLORD'S <br />GENERAL CONTRACTOR'S CONTRACT FOR ALARM MONITORING SERVICES SHALL HAVE PROVISIONS THAT WILL ALLOW, AT STAPLES' <br />DISCRETION, THE CONTRACT TO BE TRANSFERRED TO STAPLES' AT THE END OF THE CONTRACT TERM. <br />7. THE LANDLORD'S GENERAL CONTRACTOR SHALL PROVIDE A COMPLETE MICROPROCESSOR BASED 24 VDC, CLOSED CIRCUIT, <br />ELECTRICALLY SUPERVISED, NON -CODED, INTELLIGENT FIRE ALARM SYSTEM INCLUDING CONTROL EQUIPMENT, POWER SUPPLIES, <br />SIGNAL INITIATING DEVICES, AND SIGNAL INDICATING DEVICES. THE FIRE ALARM SYSTEM AND ALL COMPONENTS SHALL COMPLY WITH <br />AND BE INSTALLED AND TESTED IN ACCORDANCE WITH ALL NFPA AND LOCAL CODES, AND SHALL BE UL LISTED. A CERTIFICATION <br />OF COMPLETION FORM FOUND IN NFPA 72 SHALL BE COMPLETED AND SUBMITTED TO THE AUTHORITY HAVING JURISDICTION AND A <br />COPY SENT TO STAPLES. <br />8. THE FIRE ALARM SYSTEM SHALL RECEIVE INPUTS FROM SIGNAL INITIATING DEVICES INCLUDING BUT NOT LIMITED TO FIRE <br />SPRINKLER SYSTEM FLOW SWITCHES AND SUPERVISORY SWITCHES, DUCT MOUNTED SMOKE DETECTORS PULL STATIONS AND OTHER <br />MONITOR MODULES AND DEVICES AS MAY BE REQUIRED BY THE AUTHORITY HAVING JURISDICTION. <br />16.09.B. <br />SPRINKLER SYSTEM ELECTRONICALLY SUPERVISED MONITORING SYSTEM: <br />1. IN JURISDICTIONS WHERE ONLY A SPRINKLER SYSTEM ELECTRONICALLY SUPERVISED MONITORING SYSTEM IS REQUIRED, SUCH <br />SYSTEM SHALL PROVIDE ALARM OUTPUTS TO SIGNAL INDICATINGDEVICES INCLUDING BUT NOT LIMITED COMBINATION HORN/STROBES, <br />STROBES, BELLS, OR DEVICES AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION. THE FIRE SPRINKLER MONITORING SYSTEM <br />SHALL BE PROVIDED WITH TELEPHONE CONNECTIONS AND DIALER/MODEM TO REMOTELY INDICATE FIRE ALARM AND TROUBLE <br />i SIGNALS AS REQUIRED BY NFPA 72 AND THE AUTHORITY HAVING JURISDICTION. THE FIRE SPRINKLER MONITORING SYSTEM SHALL <br />ALSO PROVIDE THE REQUIRED SIGNALS TO THE MONITORING COMPANY IN THE TIME FRAME REQUIRED BY NFPA 72 AND OR THE <br />CENTRAL STATION, WHICH EVER IS MORE RESTRICTIVE. <br />2. FIRE SPRINKLER MONITORING SYSTEM DEVICES: <br />A. MONITOR MODULES: THE LANDLORD'S GENERAL CONTRACTOR SHALL PROVIDE MONITOR MODULES, WHERE REQUIRED, TO <br />INTERFACE WITH CONTACTS TO BE MONITORED INCLUDING BUT NOT LIMITED FLOW AND SUPERVISORY SWITCHES AND DUCT MOUNTED <br />SMOKE DETECTORS WHEN REQUIRED TO BE PROVIDED. THE MODULE SHALL BE CAPABLE OF FIELD ADDRESSING AND TESTING. <br />B. REMOTE ANNUNCIATOR: THE LANDLORD'S GENERAL CONTRACTOR SHALL PROVIDE A REMOTE ANNUNCIATOR TO REPEAT INDICATIONS <br />OF THE FIRE ALARM CONTROL OR MONITORING PANEL. THE REMOTE ANNUNCIATOR SHALL RECEIVE POWER FROM THE FIRE ALARM <br />CONTROL OR MONITORING PANEL. <br />■ <br />NATIONAL ACCOUNT VENDOR LIST CURRENT AS OF 07/30/07 <br />1. STANDARD ELECTRIC MISCELLANEOUS ELECTRICAL EQUIPMENT AND LIGHTING <br />14 JEWEL DRIVE <br />WILMINGTON, MA 01887-0676 <br />PHONE: 978-661-1860 <br />W W W. STANDARDELECTRIC.COM <br />2. LENNOX INDUSTRIES, INC. HVAC EQUIPMENT <br />2100 LAKE PARK BLVD. <br />RICHARDSON, TX 75080 <br />PHONE: 800-367-6285 <br />WWW.DAVELENNOX.COM <br />3. FLOORTECH INDUSTRIES CARPET <br />50 HUDSON RD. <br />CANTON, MA 02021 <br />PHONE: 781-589-4569 <br />4. BESAM AUTOMATED ENTRANCE SYSTEMS AUTOMATIC DOORS <br />i 84 TWIN RIVER DRIVE <br />HIGHTSTOWN, NJ 08520-5213 <br />PHONE: 866-237-2687 <br />WWW.BESAM.COM <br />5. BEST ACCESS SYSTEMS DOOR HARDWARE <br />31 THORPE ROAD <br />NEEDHAM, MA 02494 <br />PHONE: 800-562-5722 EXT. 230; <br />781-449-6900 <br />WWW.BESTACCESS.COM <br />6. REGIONAL VENDOR ASSIGNED BY STAPLES. <br />NOTE: CONTACT STAPLES' ASSIGNED <br />CONSTRUCTION PROJECT MANAGER TO VERIFY <br />ASSIGNED VENDOR <br />- AFA PROTECTIVE SYSTEMS <br />PHONE: 781-848-6200 <br />- VECTOR SECURITY <br />PHONE: 215-517-51 64 <br />7. REGIONAL VENDOR ASSIGNED BY STAPLES. <br />NOTE: CONTACT STAPLES' ASSIGNED <br />CONSTRUCTION PROJECT MANAGER TO VERIFY <br />ASSIGNED VENDOR <br />KIEFFER & CO., INC. <br />585 BOND ST. <br />LINCOLNSHIRE, IL 60069 <br />PHONE: 847-520-1255 <br />SECURITY/BURGLAR ALARM AND EQUIPMENT <br />EXT. BUILDING SIGNAGE <br />■ <br />1. LANDLORD'S GENERAL CONTRACTOR SHALL PROVIDE TO STAPLES PROJECT MANAGEMENT TEAM MINIMUM OF TWELVE (12) <br />SITE/BUILDING CONDITION DIGITAL PHOTOGRAPHS, EVERY WEEK, LABELED AND DATED. <br />2• THE LANDLORD'S GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS WITH STAPLES PROJECT <br />MANAGEMENT TEAM BEFORE COMMENCING ANY PHASE OF THE WORK. NOTIFY STAPLES PROJECT MANAGEMENT TEAM OF ANY <br />CONFLICTS DISCREPANCIES OR OMISSIONS PRIOR TO COMMENCEMENT OF THE CONTRACT WORK. <br />3. ANY REFERENCE MADE TO CONTRACTORS, INCLUDING BUT NOT LIMITED TO L.L.C., G.C., OR E.C., INDICATES WORK WHICH IS <br />THE SOLE RESPONSIBILITY OF THE LANDLORD'S GENERAL CONTRACTOR UNLESS SPECIFICALLY NOTED TO BE WORK <br />PERFORMED BY STAPLES. SUBCONTRACTORS ARE THOSE INDIVIDUALS AND/OR COMPANIES PROVIDING SERVICES, PRODUCTS <br />AND PORTIONS OF THE WORK DESCRIBED IN THE CONSTRUCTION DOCUMENTS UNDER DIRECT CONTRACT TO THE <br />LANDLORD'S GENERAL CONTRACTOR. <br />4` THE PROJECT RESPONSIBILITY SCHEDULE ON SHEET T-1 IS TO OUTLINE THE RESPONSIBILITY OF THE LANDLORD'S GENERAL <br />CONTRACTOR AND STAPLES. <br />5. PUBLICLY ACCESSIBLE PORTIONS OF THE BUILDING INCLUDING SIDEWALKS, ENTRY RAMPS, AND EXIT DOORS SHALL COMPLY <br />AT A MINIMUM WITH THE AMERICANS WITH DISABILITIES ACT, TITLE 111, AND LOCAL ARCHITECTURAL BARRIER BOARDS. <br />" " DETAILS REFERRED TO AS TYPICALSHALL BE CONSIDERED AS A TYPICAL_ CONDITION REPEATED THROUGHOUT THE PROJECT, <br />, <br />WHETHER REFERENCED OR NOT. <br />I I THE EVENT F OMISSION F <br />THESE DRAWINGS SHALL NOT BE SCALED FOR THE PURPOSES OF CONSTRUCTION. N E E EN O 0 SS ON 0 <br />7. E <br />NECESSARY DIMENSIONS OR INFORMATION, LANDLORD'S GENERAL CONTRACTOR SHALL NOTIFY THE ARCHITECT FOR <br />CLARIFICATION. <br />8• LANDLORD'S GENERAL CONTRACTOR SHALL PROVIDE A FULL SET OF CONSTRUCTION DOCUMENTS TO ALL SUB -CONTRACTORS. <br />ALL CROSS-REFERENCING SHALL BE THE SOLE RESPONSIBILITY OF THE LANDLORD'S GENERAL CONTRACTOR. <br />9. UNLESS NOTED OTHERWISE, ALL DOORS ARE TO BE LOCATED AT 6" FROM INSIDE FACE OF PARTITION TO EDGE OF DOOR <br />JAMB. (HINGE SIDE ONLY) <br />10. INSTALL METAL TRIM ON ALL GYPSUM BOARD EDGES ABUTTING OTHER MATERIALS AND WHERE GYPSUM BOARD IS STOPPED <br />SHORT OF OTHER MATERIALS TO FORM A REVEAL OR RECESS. USE METAL CORNER BEADS ON ALL EXTERIOR GYPSUM BOARD <br />CORNERS. <br />11. NECESSARY BLOCKING SHALL BE PROVIDED IN WALLS WHERE GRAB BARS, CORNICE TRIM, WOOD BASE COUNTER TOPS AND <br />OTHER STAPLES PROVIDED COUNTERS REQUIRE A RIGID AND SECURE ATTACHMENT TO SAID WALL. <br />12. ALL EXTERIOR WOOD BLOCKING OR LOCKING FASTENED TO CMU SHALL BE PRESSURE TREATED. <br />13. SLOPE FLOOR TO DRAINS IN REST ROOMS, LOUNGE AND JANITOR AREA. <br />14. ALL CMU WALL JOINTS SHALL BE TOOLED TO PROVIDE A ROUND JOINT ON BOTH SIDES OF CMU WALL. <br />15. ALL CONDUIT, HANGERS, STUD TRACKS, ETC.... SHALL NOT BE ATTACHED TO THE ROOF DECK. ATTACH TO STRUCTURAL <br />MEMBERS ONLY. <br />16. THE INSTALLING CONTRACTOR SHALL MAINTAIN A STAMPED "APPROVED" SET OF DRAWINGS IN THE FIELD/SITE AT ALL TIMES <br />DURING INSTALLATION AND CONSTRUCTION. <br />u <br />SYMBOLS (ARCHITECTURAL) <br />RE COVERSHEET FOR SYMBOLS <br />REFERENCE KEY <br />RE: COVERSHEET FOR SYMBOLS <br />z <br />i <br />w <br />z' <br />O <br />z <br />cf) <br />cn <br />w <br />s� <br />w <br />w <br />cn <br />z <br />o <br />�Lm <br />m <br />rI <br />NI <br />II <br />of <br />o <br />w <br />A <br />L6 <br />U-) <br />co <br />co <br />Go <br />co <br />Lu <br />N' <br />N <br />N <br />of <br />O <br />co <br />$R <br />[If <br />N <br />[if <br />0 <br />� <br />C N <br />w <br />O <br />� <br />� <br />(,� G7 <br />a <br />o <br />o <br />T-1 <br />