ABBREVIATIONS (IN ADDITION TO COVERSHEET ABBREV.)
<br />(ABBREVIATIONS
<br />SHOWN ARE NOT NECESSARILY USED ON
<br />THE DRAWINGS)
<br />A
<br />L
<br />AB
<br />ANCHOR BOLT
<br />LB
<br />POUNDS
<br />A/C
<br />AIR CONDITIONING
<br />L.F.
<br />LINEAR FEET
<br />AC
<br />ALTERNATING CURRENT
<br />LL
<br />LIVE LOAD
<br />ACI
<br />AMERICAN CONCRETE INSTITUTE
<br />LLH
<br />LONG LEG HORIZONTAL
<br />ADJ
<br />ADJUSTABLE
<br />LLV
<br />LONG LEG VERTICAL
<br />AIC
<br />AMPHERE INTERRUPTING CURRENT
<br />LONG
<br />LONGITUDINAL
<br />AFF
<br />ABOVE FINISHED FLOOR
<br />LRA
<br />LOCK MOTOR AMPS
<br />ALUM.
<br />ALUMINUM
<br />LT
<br />LIGHT
<br />AMP
<br />AMPERE, AMPS
<br />LP
<br />LOW POINT
<br />ARCH.
<br />ARCHITECT, ARCHITECTURAL
<br />LTG
<br />LIGHTING
<br />ASHRAE
<br />AMERICAN SOCIETY OF HEATING,
<br />LWC
<br />LIGHT WEIGHT CONCRETE
<br />REFRIGERATION AND AIR
<br />L. L.
<br />LANDLORD
<br />CONDITIONING ENGINEERS
<br />ASTM
<br />AMERICAN SOCIETY OF TESTING AND
<br />MATERIALS
<br />AVG
<br />AVERAGE
<br />AWG
<br />AMERICAN WIRE GAUGE
<br />MAX
<br />MAXIMUM
<br />MCA
<br />MINIMUM CIRCUIT AMPACITY
<br />B
<br />MCB
<br />MAIN CIRCUIT BREAKER
<br />MDP
<br />MAIN DISTRIBUTION PANEL
<br />MECH
<br />MECHANICAL
<br />MFR
<br />MANUFACTURER
<br />BC
<br />BUILDING CONTRACTOR
<br />MH
<br />MANHOLE, METAL HALIDE
<br />BLDG
<br />BUILDING
<br />MIN
<br />MINIMUM
<br />BM
<br />BEAM
<br />MLO
<br />MAIN LUGS ONLY
<br />BOTT.
<br />BOTTOM
<br />MSB
<br />MAIN SWITCHBOARD
<br />BTU
<br />BRITISH THERMAL UNIT
<br />MTD
<br />MOUNTED
<br />c
<br />N
<br />C
<br />CONDUIT
<br />N/A
<br />NOT APPLICABLE
<br />C.F.
<br />CUBIC FEET
<br />NEC
<br />NATIONAL ELECTRICAL CODE
<br />CFM
<br />CUBIC FEET PER MINUTE
<br />NEMA
<br />NATIONAL ELECTRICAL
<br />CKT
<br />CIRCUIT
<br />MANUFACTURER'S ASSOCIATION
<br />CENTERLINE
<br />NF
<br />NEAR FACE
<br />CLG
<br />CEILING
<br />NFPA
<br />NATIONAL FIRE PROTECTION
<br />CLR
<br />CLEAR OR CLEARANCE
<br />ASSOCIATION
<br />CMU
<br />CONCRETE MASONRY UNIT
<br />N.I.C.
<br />NOT IN CONTRACT
<br />CO
<br />CLEANOUT
<br />NL
<br />NIGHT LIGHT
<br />COL.
<br />COLUMN
<br />NO.
<br />NUMBER
<br />CONC.
<br />CONCRETE, CONCENTRIC
<br />NOM
<br />NOMINAL
<br />CONT.
<br />CONTINUOUS, CONTINUATION
<br />NTS
<br />NOT TO SCALE
<br />COORD.
<br />COORDINATE
<br />CR
<br />CONDENSATE RETURN
<br />CJ
<br />CONSTRUCTION JOINT
<br />O
<br />CTR
<br />CENTER
<br />CV
<br />CHECK VALVE
<br />CUH
<br />CEILING UNIT HEATER
<br />OA
<br />OUTSIDE AIR
<br />CW
<br />COLD WATER
<br />OC
<br />ON CENTER
<br />OF
<br />OUTSIDE FACE
<br />OD
<br />OUTSIDE DIAMETER
<br />D
<br />OH
<br />OPPOSITE HAND
<br />OPNG
<br />OPENING
<br />OSHA
<br />OCCUPATIONAL SAFETY AND
<br />DC
<br />DIRECT CURRENT
<br />HEALTH ADMINISTRATION
<br />DL
<br />DEADLOAD
<br />DEG
<br />DEGREES
<br />P-0
<br />DTL
<br />DETAIL
<br />DIA OR 0
<br />DIAMETER
<br />DIM.
<br />DIMENSION
<br />DN
<br />DOWN
<br />PAR
<br />PARALLEL
<br />DBL
<br />DOUBLE
<br />P/C
<br />PRECAST CONCRETE
<br />DS
<br />DOWNSPOUT
<br />PC
<br />PIECE
<br />DWG
<br />DRAWING
<br />PDU
<br />POWER DISTRIBUTION UNIT
<br />PERP
<br />PERPENDICULAR
<br />PH,O
<br />PHASE
<br />PT
<br />PAI NT
<br />P L
<br />PLATE
<br />PLBG
<br />PLUMBING
<br />PNL
<br />PANEL
<br />EA
<br />EACH
<br />PIV
<br />POST INDICATOR VALVE
<br />EC
<br />ELECTRICAL CONTRACTOR
<br />PSF
<br />POUNDS PER SQUARE FOOT
<br />EF
<br />EXHAUST FAN
<br />PVC
<br />POLYVINYL CHLORIDE
<br />E.J.
<br />EXPANSION JOINT
<br />EL.
<br />ELEVATION
<br />QTY.
<br />QUANTITY
<br />ELEC.
<br />ELECTRICAL
<br />EMP.
<br />EMS
<br />EMPLOYEE
<br />ENERGY MANAGEMENT SYSTEM
<br />ENCL.
<br />ENCLOSURE
<br />ENT.
<br />ENTRY, ENTRANCE
<br />EQ.
<br />EQUAL
<br />EW
<br />EACH WAY
<br />RA
<br />RETURN AIR
<br />EXP
<br />EXPANSION
<br />RAD
<br />RADIUS
<br />EQUIP
<br />EQUIPMENT
<br />RCP
<br />REFLECTED CEILING PLAN,
<br />EWC
<br />ELECTRIC WATER COOLER
<br />RD
<br />ROOF DRAIN
<br />EWH
<br />ELECTRIC WATER HEATER
<br />RE:
<br />REFERENCE, REFER
<br />EXH
<br />EXHAUST
<br />REINF.
<br />REINFORCING
<br />EXIST.
<br />EXISTING
<br />REQD
<br />REQUIRED
<br />EXT.
<br />EXTERNAL, EXTERIOR
<br />RLA
<br />RUNNING LOAD AMPS
<br />RM
<br />ROOM
<br />RPM
<br />RTU
<br />REVOLUTIONS PER MINUTE
<br />ROOFTOP UNIT
<br />FA
<br />FIRE ALARM
<br />FACP
<br />FIRE ALARM CONTROL PANEL
<br />FCO
<br />FLOOR CLEANOUT
<br />SC
<br />SITE CONTRACTOR
<br />FD
<br />FIN
<br />FIRE DAMPER, FLOOR DRAIN
<br />FINISH (ED)
<br />SCHED.
<br />SCHEDULED
<br />FIXT.
<br />FIXTURE
<br />SCHR
<br />SECONDARY CHILLED WATER RETURN
<br />FDN
<br />FOUNDATION
<br />SD
<br />SMOKE DAMPER, STORM DRAIN
<br />FLG
<br />FLANGE
<br />SECT.
<br />SECTION
<br />FTG
<br />FOOTING
<br />S
<br />S.F.
<br />SENSOR
<br />SQUARE FEET
<br />FS
<br />FAR SIDE
<br />SHT
<br />SHEET
<br />F.F.
<br />FINISHED FLOOR
<br />SIM
<br />SIMILAR
<br />FLR
<br />FLOOR
<br />SHT. MTL.
<br />SHEET METAL
<br />FLUOR.
<br />FLUORESCENT
<br />SPEC.
<br />SPECIFICATION
<br />FRP
<br />FIBERGLASS REINFORCED PANEL_
<br />SQ.
<br />SQUARE
<br />FT.
<br />FOOT, FEET
<br />SS
<br />STAINLESS STEEL, SANITARY SEWER
<br />STC
<br />SOUND TRANSMISSION CLASS
<br />STD.
<br />STANDARD
<br />STL.
<br />STEEL
<br />STIFF
<br />STIFFENER
<br />STIR.
<br />STIRRUPS
<br />GA.
<br />GAUGE
<br />SUSP.
<br />SUSPENDED
<br />GALV.
<br />GALVANIZED
<br />SYMM
<br />SYMMETRICAL
<br />GB
<br />GRADE BEAM
<br />GC
<br />GENERAL CONTRACTOR
<br />GFI
<br />GROUND FAULT CIRCUIT INTERRUPTER
<br />GND
<br />GROUND-�
<br />GWB
<br />GYPSUM WALL BOARD
<br />T&B
<br />TOP AND BOTTOM
<br />TEF
<br />TOILET EXHAUST FAN
<br />T/FTG
<br />TOP OF FOOTING
<br />THICK
<br />THICKNESS
<br />TOJ
<br />TOP OF JOIST
<br />HGT
<br />HEIGHT
<br />TOS
<br />TOP OF STEEL
<br />HID
<br />HIGH INTENSITY DISCHARGE
<br />THRU
<br />T
<br />THROUGH
<br />THERMOSTAT
<br />HORIZ.
<br />HORIZONTAL
<br />TYP
<br />TYPICAL
<br />HP
<br />HORSEPOWER
<br />TS
<br />TEMPERATURE SENSOR
<br />HTR
<br />HEATER
<br />HVAC
<br />HEATING, VENTILATING AND AIR
<br />CONDITIONING
<br />U-V
<br />HVU
<br />HEATING AND VENTILATING UNIT
<br />H VY
<br />HEAVY
<br />-
<br />--
<br />UL
<br />UNDERWRITERS LABORATORIES, INC.
<br />U.O.N.
<br />UNLESS OTHERWISE NOTED
<br />UPS
<br />UNINTERRUPTIBLE POWER SUPPLY
<br />V
<br />VOLT
<br />1. D.
<br />INSIDE DIAMETER
<br />VA
<br />VOLT-AMPERE
<br />I.E.
<br />INVERT ELEVATION
<br />VERT,
<br />VERTICAL
<br />IG
<br />ISOLATED GROUND
<br />VTR
<br />VENT THROUGH ROOF
<br />I NT.
<br />INTERIOR
<br />INTER
<br />IN.
<br />INTERMEDIATE
<br />INCH,INCHESw_x_y_z
<br />INSUL.
<br />INSULATION
<br />W
<br />WATT
<br />W/
<br />WITH
<br />W/0
<br />WITHOUT
<br />WCO
<br />WALL CLEAN OUT
<br />J-BOX
<br />JUNCTION BOX
<br />W.C.
<br />WATER CLOSET
<br />JT
<br />JOINT
<br />WL
<br />WIND LOAD
<br />WP
<br />WEATHERPROOF
<br />W.O.
<br />WWF
<br />WALL OPENING
<br />WELDED WIRE FABRIC
<br />XFMR
<br />TRANSFORMER
<br />k
<br />KIPS (1000 LBS)
<br />YD
<br />YARD
<br />kCMIL
<br />1000 CIRCULAR MILS
<br />kV
<br />KILOVOLT
<br />kVA
<br />KILOVOLT -AMPS
<br />kW
<br />KILOWATT
<br />kWH
<br />KILOWATT-HOUR
<br />m
<br />I
<br />E
<br />FIRE PROTECTION NOTES
<br />SEE OUTLINE SPECIFICATION FOR COMPLETE FIRE PROTEC7nON SPECIFICATIONS.
<br />15.21.A.
<br />FIRE PROTECTION DESIGN FOR THE SITE SPECIFIC, FINAL SPECIFICATION SHALL BE DESIGNED IN COMPLIANCE WITH THE ADOPTED
<br />EDITION OF NFPA 13, NFPA 24, THE ADOPTED FIRE CODE AND LOCAL JURISDICTIONAL REQUIREMENTS AND/OR AMENDMENTS TO
<br />THE ADOPTED CODES. ALL FIRE PROTECTION SYSTEMS FOR THE ENTIRE RETAIL SALES AND RECEIVING AREAS SHALL MEET THE
<br />REQUIREMENTS FOR STORAGE OF COMMODITIES IN SINGLE -ROW AND DOUBLE -ROW RACKS AS WELL AS SOLID SHELF GONDOLA
<br />RACKS WHICH HAVE AN OVERALL WIDTH GREATER THAN 30 INCHES AND FOR STORAGE OF COMMODITIES TO A MAXIMUM HEIGHT OF
<br />12'-0".
<br />15.21.13.
<br />THE LANDLORD'S GENERAL CONTRACTOR SHALL PROVIDE A COMPLETE AND FULLY FUNCTIONAL FIRE PROTECTION SYSTEM INCLUDING
<br />BUT NOT LIMITED TO ALL MATERIALS AND EQUIPMENT AS NOTED IN PROTOTYPE DOCUMENTS.
<br />15.21.C.
<br />THE SPRINKLER SYSTEM SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NFPA STANDARDS AND ALL APPLICABLE LOCAL
<br />CODES, AND SHALL CONFORM TO THE REGULATIONS AND REQUIREMENTS OF ALL AUTHORITIES HAVING JURISDICTION.
<br />15.21.D.
<br />THE SPRINKLER SYSTEM FOR THE ENTIRE SALES AND RECEIVING AREAS SHALL BE DESIGNED IN ACCORDANCE WITH NFPA 13
<br />REQUIREMENTS FOR GONDOLA RACK STORAGE GREATER THAN 30 INCHES IN OVERALL WIDTH, WHICH ARE TREATED AS RACKS WITH
<br />SOLID SHELVING, IN ADDITION TO SINGLE AND DOUBLE -ROW RACK STORAGE OF CLASS I -IV NON -ENCAPSULATED COMMODITIES TO
<br />AN OVERALL HEIGHT OF 12'-0 ADDITIONAL PROVISIONS TO PROTECTING SOLID SHELVING GONDOLA RACK STORAGE MAY BE
<br />FOUND IN NFPA 13, 2002 EDITION. WHEN THE 2002 EDITION IS USED FOR DESIGN, SUCH EDITION SHALL BE ADOPTED BY THE
<br />AUTHORITY HAVING JURISDICTION OR AN "ALTERNATE MATERIALS AND METHOD" SHALL BE PROPOSED AND SUCH ALTERNATE USE
<br />APPROVED BY THE JURISDICITON IN ORDER TO USE THE 2002 EDITION OF NFPA 13 AS DESIGN CRITERIA. AISLE WIDTHS SHALL
<br />BE IN ACCORDANCE WITH THE ADOPTED FIRE CODE AND NFPA 13 FOR THE SPRINKLER HEAD UTILIZED IN THE DESIGN.
<br />15.21.E.
<br />GONDOLA RACKS SHALL UTILIZE SOLID SHELVES TO A HEIGHT OF 10'-0" A.F.F. WITH MAXIMUM STORAGE HEIGHTS NOT EXCEEDING
<br />12'-0" AFF. THE SPRINKLER SYSTEM FOR THE OFFICE AREAS SHALL BE DESIGNED IN ACCORDANCE WITH NFPA 13 REQUIREMENTS
<br />FOR LIGHT HAZARD OCCUPANCIES. r
<br />15.21.F.
<br />THE SPRINKLER SYSTEM SHALL BE OF A DESIGN WHICH IS HYDRAULICALLY CALCULATED IN ACCORDANCE WITH NPFA STANDARDS 13
<br />AND 24. THE LANDLORD'S FIRE SPRINKLER CONTRACTOR SHALL VERIFY THE CURRENTLY AVAILABLE WATER SUPPLY, DESIGN THE
<br />FIRE PROTECTION IN ACCORDANCE WITH THE CURRENTLY AVAILABLE WATER SUPPLY. THE CONTRACTOR SHALL SUBMIT FINAL
<br />SPRINKLER SYSTEM DESIGN DRAWINGS AND HYDRAULIC CALCULATIONS TO THE LOCAL FIRE OFFICIAL OR TO A THIRD PARTY PLAN
<br />REVIEWER FOR REVIEW WHEN DIRECTED TO DO SO BY THE AUTHORITY HAVING JURISDICTION.
<br />15.22.A.
<br />ALL MATERIALS AND DEVICES REQUIRED FOR A COMPLETE AND OPERATIONAL FIRE PROTECTION SYSTEM SHALL BE LISTED AND
<br />APPROVED FOR SUCH USE AS REQUIRED BY NFPA STANDARDS 13 AND 24.
<br />15.22.13.
<br />PIPING JOINTS SHALL BE EITHER WELDED, THREADED, OR GROOVED ACCORDING TO MANUFACTURER'S RECOMMENDATIONS.
<br />15.22.C.
<br />A SEPARATE ALARM CHECK VALVE IS REQUIRED ON ALL RISER ASSEMBLIES.
<br />15.22.D.
<br />VALVES FOR SPRINKLER OPERATION SHALL BE THE LISTED, INDICATING TYPE, AS REQUIRED BY NFPA 13 AND/OR NFPA 24. VALVES
<br />INSIDE THE BUILDING SHALL BE OUTSIDE -SCREW -AND -YOKE (OS&Y) TYPE OR OF A TYPE MANDATED BY THE AUTHORITY HAVING
<br />JURISDICTION. SUCH VALVES SHALL BE NORMALLY IN THE OPEN POSITION, AND SHALL BEAR SUPERVISORY SWITCHES CONNECTED
<br />TO AN APPROVED ELECTRONIC SUPERVISORY MONITORING SYSTEM. THE LANDLORD'S GENERAL CONTRACTOR SHALL PROVIDE ALL
<br />REQUIRED ELECTRICAL CONNECTIONS FOR ALL COMPONENTS CONNECTED TO THE SUPERVISORY MONITORING SYSTEM.
<br />15.22.E.
<br />CHECK VALVES AND BACKFLOW PREVENTION ASSEMBLIES SHALL BE OF AN APPROVED TYPE AND BE SHALL BE INSTALLED IN
<br />COMPLIANCE WITH LISTING REQUIREMENTS AS REQUIRED BY THE LOCAL AUTHORITY HAVING JURISDICTION. LOCATION OF BACKFLOW
<br />ASSEMBLIES SHALL BE APPROVED BY THE AUTHORITY HAVING JURISDICTION.
<br />15.22. F.
<br />IN AREAS SUBJECT TO FREEZING, BACKFLOW PREVENTION ASSEMBLIES SHALL BE INSTALLED IN LOCATIONS DETERMINED BY THE
<br />AUTHORITY HAVING JURISDICTION. THE MAXIMUM DISTANCE ALLOWED FROM A FIRE HYDRANT TO THE FIRE DEPARTMENT CONNECTION
<br />SHALL ALSO BE DETERMINED BY THE AUTHORITY HAVING JURISDICTION.
<br />15.22.G.
<br />ALL OTHER VALVES SHALL BE EITHER BRONZE OR IRON -BODY FLANGED VALVES OR IRON -BODY FLANGED OS&Y GATE VALVES OR
<br />AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION.
<br />15.22.H.
<br />ALL HANGERS SHALL CONFORM TO THE REQUIREMENTS OF NFPA 13. PIPING SHALL BE SUPPORTED AND BRACED FROM THE
<br />BUILDING STRUCTURE AS REQUIRED IN NFPA 13 AND TO MAINTAIN REQUIRED ELEVATION AND PITCH OF PIPE, TO PREVENT
<br />VIBRATION, ALLOW SEISMIC MOVEMENT AND TO SECURE PIPING IN PLACE.
<br />15.22.1.
<br />LANDLORD'S GENERAL CONTRACTOR SHALL PROVIDE A TYPE AND NUMBER OF BOXES SUCH AS "KNOX" OR "SUPRA" BRAND KEY
<br />STORAGE BOXES AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION AND/OR LOCAL FIRE DEPARTMENT. LOCATION OF KEY
<br />BOX(ES) SHALL BE COORDINATED WITH LOCAL JURISDICTION AND STAPLES PROJECT MANAGEMENT TEAM.
<br />15.23.A.
<br />SPRINKLERS SHALL BE DESIGNED, INSTALLED AND TESTED IN CONFORMANCE WITH NFPA STANDARDS 13 AND 24.
<br />15.23.13.
<br />SPRINKLERS SHALL BE THE UPRIGHT TYPE IN AREAS WITHOUT SUSPENDED CEILINGS AND SHALL BE OF THE RECESSED PENDANT
<br />TYPE IN AREAS WITH SUSPENDED CEILINGS. SPRINKLERS IN SUSPENDED CEILING AREAS SHALL BE LOCATED AS CLOSE TO CENTER
<br />OF CEILING TILES AS POSSIBLE.
<br />15.23.C.
<br />AT PROJECT COMPLETION, THE LANDLORD'S GENERAL CONTRACTOR SHALL ENSURE THAT THE SPRINKLER CONTRACTOR HAS AFFIXED
<br />A DESIGN CALCULATION TAG TO THE RISER STATING THE SPRINKLER SYSTEM DESIGN CRITERIA. THE LANDLORD'S GENERAL
<br />CONTRACTOR SHALL ALSO ENSURE THAT THE SPRINKLER CONTRACTOR HAS PROVIDED THE NUMBER AND TYPE OF SPARE
<br />SPRINKLERS AS REQUIRED IN NFPA 13 AND THE REQUIRED PIPE WRENCH(S) IN A METAL HEAD BOX NEXT TO SPRINKLER RISER.
<br />THE LANDLORD'S GENERAL CONTRACTOR SHALL PROVIDE THE METAL SPRINKLER HEAD BOX AT SPRINKLER RISER LOCATION.
<br />15.24.A.
<br />SPRINKLERS SHALL BE LOCATED AS FOLLOWS:
<br />1. IN RETAIL SALES AND STORAGE AREAS, SPRINKLERS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NFPA 13 FOR
<br />THE APPROPRIATE HAZARD AND IN ACCORDANCE WITH THE INSIDE CLEAR CEILING HEIGHT AND THE LISTING OF THE SPRINKLER
<br />HEAD(S) PROPOSED TO BE INSTALLED.
<br />2. IN LIGHT HAZARD AREAS, SPRINKLERS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NFPA 13' FOR THE
<br />APPROPRIATE HAZARD AND IN ACCORDANCE: WITH THE CEILING HEIGHT AND LISTING OF THE SPRINKLER HEAD(S) PROPOSED TO BE
<br />INSTALLED.
<br />15.24.B.
<br />SPRINKLER SYSTEM ACCEPTANCE TESTING SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA 13 AND THE
<br />JURISDICTIONAL_ AUTHORITIES. SPRINKLER PIPING SHALL BE TESTED AND MADE WATERTIGHT PRIOR TO ANY PAINTING AND/OR
<br />CONCEALMENT AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION DURING PROGRESS AND/OR COMPLETION OF WORK. LEAKS
<br />SHALL BE IMMEDIATELY REPAIRED. CAULKING IS NOT ALLOWED FOR SPRINKLER SYSTEM LEAK PREVENTION OR REPAIR.
<br />15.24.C.
<br />THE LANDLORD'S GENERAL CONTRACTOR SHALL NOTIFY STAPLES AND THE LOCAL JURISDICTIONAL AUTHORITIES PRIOR TO ANY FIRE
<br />PROTECTION SYSTEM TESTING.
<br />15.24.D.
<br />SPRINKLER HEADS SHALL BE FREE OF NON -FACTORY APPLIED PAINT AT THE COMPLETION OF THE PROJECT. HEADS DAMAGED BY
<br />PAINT DURING CONSTRUCTION SHALL BE REPLACED AT NO COST TO STAPLES.
<br />15.24.E.
<br />PRIOR TO FINAL COMPLETION, THE LANDLORD'S GENERAL CONTRACTOR SHALL PROVIDE STAPLES WITH THE FOLLOWING:
<br />1. A SIGNED COPY OF THE FORM PROVIDED IN NFPA 13 AND NFPA 24 KNOWN AS THE "CONTRACTOR'S MATERIAL AND TEST
<br />CERTIFICATE" FOR BOTH THE UNDERGROUND AND THE OVERHEAD FIRE PROTECTION SYSTEMS. THESE FORMS ARE REQUIRED TO BE
<br />COMPLETED AND SIGNED BY THE FIRE PROTECTION CONTRACTOR AND SIGNED BY LOCAL JURISDICTIONAL AUTHORITIES WHO HAVE
<br />WITNESSED THE TESTING AND FINAL ACCEPTANCE OF THE SYSTEM(S);
<br />2. COPIES OF LITERATURE AND INSTRUCTIONS FROM SYSTEM EQUIPMENT MANUFACTURERS DESCRIBING PROPER OPERATION AND
<br />MAINTENANCE OF EQUIPMENT, AND A COMPLETED COPY OF NFPA STANDARD 25, "STANDARD FOR THE INSPECTION, TESTING AND
<br />MAINTENANCE OF WATER -BASED FIRE PROTECTION SYSTEMS," BOUND IN A THREE-RING BINDER PROPERLY LABELED; AND,
<br />3. LANDLORD'S GENERAL CONTRACTOR SHALL PROVIDE TWO (2) COPIES OF THE APPROVED SPRINKLER SYSTEM DESIGN
<br />CALCULATIONS AND APPROVED PLANS, BEARING THE STAMPED APPROVAL OF THE AUTHORITY HAVING JURISDICTION. ONE (1) COPY
<br />SHALL BE INCLUDED WITH THE AS -BUILT DRAWINGS IN THE PLAN TUBE LOCATED IN THE TELECOM ROOM ,AND ONE (1) COPY
<br />PROVIDED WITH PROJECT CLOSEOUT.
<br />16.09.A.
<br />FIRE ALARM SYSTEM:
<br />1. THE ALARM SYSTEM SHALL BE DESIGNED IN ACCORDANCE WITH NFPA 72 AND FURNISHED AND INSTALLED BY THE LANDLORD'S
<br />GENERAL CONTRACTOR WHEN REQUIRED TO DO SO BY LOCALLY ADOPTED CODES OR ORDINANCES. THE LANDLORD'S GENERAL
<br />CONTRACTOR SHALL PROVIDE THE COMPLETE FIRE ALARM SYSTEM AS SPECIFIED HEREIN.
<br />2. FIRE ALARM CONTROL. PANEL:
<br />A. THE LANDLORD'S GENERAL CONTRACTOR SHALL PROVIDE A CONTROL PANEL MODULAR IN DESIGN UTILIZING DISTRIBUTED SOLID
<br />STATE, FIELD PROGRAMMABLE MICROPROCESSORS WITH CAPABILITY FOR EXPANSION. THE SYSTEM SHALL BE CAPABLE OF
<br />n PROVIDING AUTOMATIC. AND MANUAL_ SELF -TESTS. THE SYSTEM SHALL HAVE AN ALPHA -NUMERIC LIQUID CRYSTAL DISPLAY,
<br />TOUCHPAD CONTROLS AND LIGHT EMITTING DIODE INDICATORS FOR AC POWER, SYSTEM ALARM AND TROUBLE, AND DISABLE. THE
<br />SYSTEM SHALL RECEIVE INFORMATION FROM AND COMMUNICATE CONTINUOUSLY WITH ALL INDICATING DEVICES AND MONITOR
<br />MODULES. THE SYSTEM SHALL BE PROVIDED WITH AN INTEGRAL POWER SUPPLY WITH CAPACITY TO POWER THE PANEL_ AND ALL
<br />FIRE ALARM PERIPHERALS AND SHALL BE SUPERVISED.
<br />B. REMOTE ANNUNCIATOR: AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION OR AS REQUIRED BY THE ADOPTED CODES; THE
<br />LANDLORD'S GENERAL CONTRACTOR SHALL PROVIDE A REMOTE ANNUNCIATOR TO REPEAT, INDICATIONS OF THE FIRE ALARM CONTROL
<br />PANEL. THE REMOTE ANNUNCIATOR SHALL RECEIVE POWER FROM THE FIRE ALARM CONTROL PANEL.
<br />C. PULL STATIONS: AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION OR AS REQUIRED BY THE ADOPTED CODES; THE
<br />LANDLORD'S GENERAL CONTRACTOR SHALL PROVIDE NON -BREAK GLASS, DUAL ACTION, KEY RESET, ADDRESSABLE MANUAL PULL
<br />STATIONS.
<br />D. STROBES AND COMBINATION HORN/STROBES: THE LANDLORD'S GENERAL CONTRACTOR SHALL PROVIDE 24 VDC, 75 CANDELA
<br />(MIN) STROBES, 90 DBA HORNS. THE INDICATING DEVICES SHALL SATISFY ALL REQUIREMENTS OF THE AMERICANS' WITH
<br />DISABILITIES ACT.
<br />E. MONITOR MODULES: THE LANDLORD'S GENERAL CONTRACTOR SHALL PROVIDE MONITOR MODULES WHERE REQUIRED TO
<br />INTERFACE WITH CONTACTS TO BE MONITORED INCLUDING BUT NOT LIMITED FLOW AND SUPERVISORY SWITCHES AND DUCT MOUNTED
<br />SMOKE DETECTORS WHEN REQUIRED TO BE PROVIDED. THE MODULE SHALL BE CAPABLE OF FIELD ADDRESSING AND TESTING.
<br />3. THE LANDLORD'S GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE LOCAL REQUIREMENTS FOR A FIRE
<br />ALARM AND OR MONITORING SYSTEM AND SHALL NOTIFY STAPLES' IN WRITING OF SUCH REQUIREMENT AND INDICATE THE SYSTEM
<br />DESIGN REQUIREMENTS ON THE CONSTRUCTION DOCUMENTS DURING THE ENGINEERING AND DESIGN PHASE OF THE PROJECT.
<br />FIRE PROTECTION NOTES (CONTINUED
<br />4. IF LOCAL CODES REQUIRES AN INDEPENDENT AGENCY TO MONITOR THE FIRE ALARM SYSTEM, PROVISIONS ARE REQUIRED TO
<br />CONNECT STAPLES' SECURITY SYSTEM TO THE FIRE ALARM SYSTEM IN ADDITION TO THE INDEPENDENT MONITORING AGENCY
<br />CONNECTION.
<br />5. IF THE LOCAL FIRE CODES REQUIRE A SPECIFIC AGENCY OR TYPE OF (SUCH AS U.L.) CENTRAL STATION TO MONITOR THE FIRE
<br />ALARM SYSTEM, STAPLES' SHALL BE NOTIFIED AND SHALL HAVE APPROVAL RIGHTS SELECTING THE MONITORING AGENCY.
<br />6. THE LANDLORD'S GENERAL CONTRACTOR SHALL BE REQUIRED TO EXECUTE A CONTRACT WITH THE APPROVED MONITORING
<br />AGENCY AS NECESSARY TO OBTAIN THE CERTIFICATE OF OCCUPANCY PRIOR TO DELIVERY OF THE PREMISES. THE LANDLORD'S
<br />GENERAL CONTRACTOR'S CONTRACT FOR ALARM MONITORING SERVICES SHALL HAVE PROVISIONS THAT WILL ALLOW, AT STAPLES'
<br />DISCRETION, THE CONTRACT TO BE TRANSFERRED TO STAPLES' AT THE END OF THE CONTRACT TERM.
<br />7. THE LANDLORD'S GENERAL CONTRACTOR SHALL PROVIDE A COMPLETE MICROPROCESSOR BASED 24 VDC, CLOSED CIRCUIT,
<br />ELECTRICALLY SUPERVISED, NON -CODED, INTELLIGENT FIRE ALARM SYSTEM INCLUDING CONTROL EQUIPMENT, POWER SUPPLIES,
<br />SIGNAL INITIATING DEVICES, AND SIGNAL INDICATING DEVICES. THE FIRE ALARM SYSTEM AND ALL COMPONENTS SHALL COMPLY WITH
<br />AND BE INSTALLED AND TESTED IN ACCORDANCE WITH ALL NFPA AND LOCAL CODES, AND SHALL BE UL LISTED. A CERTIFICATION
<br />OF COMPLETION FORM FOUND IN NFPA 72 SHALL BE COMPLETED AND SUBMITTED TO THE AUTHORITY HAVING JURISDICTION AND A
<br />COPY SENT TO STAPLES.
<br />8. THE FIRE ALARM SYSTEM SHALL RECEIVE INPUTS FROM SIGNAL INITIATING DEVICES INCLUDING BUT NOT LIMITED TO FIRE
<br />SPRINKLER SYSTEM FLOW SWITCHES AND SUPERVISORY SWITCHES, DUCT MOUNTED SMOKE DETECTORS PULL STATIONS AND OTHER
<br />MONITOR MODULES AND DEVICES AS MAY BE REQUIRED BY THE AUTHORITY HAVING JURISDICTION.
<br />16.09.B.
<br />SPRINKLER SYSTEM ELECTRONICALLY SUPERVISED MONITORING SYSTEM:
<br />1. IN JURISDICTIONS WHERE ONLY A SPRINKLER SYSTEM ELECTRONICALLY SUPERVISED MONITORING SYSTEM IS REQUIRED, SUCH
<br />SYSTEM SHALL PROVIDE ALARM OUTPUTS TO SIGNAL INDICATINGDEVICES INCLUDING BUT NOT LIMITED COMBINATION HORN/STROBES,
<br />STROBES, BELLS, OR DEVICES AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION. THE FIRE SPRINKLER MONITORING SYSTEM
<br />SHALL BE PROVIDED WITH TELEPHONE CONNECTIONS AND DIALER/MODEM TO REMOTELY INDICATE FIRE ALARM AND TROUBLE
<br />i SIGNALS AS REQUIRED BY NFPA 72 AND THE AUTHORITY HAVING JURISDICTION. THE FIRE SPRINKLER MONITORING SYSTEM SHALL
<br />ALSO PROVIDE THE REQUIRED SIGNALS TO THE MONITORING COMPANY IN THE TIME FRAME REQUIRED BY NFPA 72 AND OR THE
<br />CENTRAL STATION, WHICH EVER IS MORE RESTRICTIVE.
<br />2. FIRE SPRINKLER MONITORING SYSTEM DEVICES:
<br />A. MONITOR MODULES: THE LANDLORD'S GENERAL CONTRACTOR SHALL PROVIDE MONITOR MODULES, WHERE REQUIRED, TO
<br />INTERFACE WITH CONTACTS TO BE MONITORED INCLUDING BUT NOT LIMITED FLOW AND SUPERVISORY SWITCHES AND DUCT MOUNTED
<br />SMOKE DETECTORS WHEN REQUIRED TO BE PROVIDED. THE MODULE SHALL BE CAPABLE OF FIELD ADDRESSING AND TESTING.
<br />B. REMOTE ANNUNCIATOR: THE LANDLORD'S GENERAL CONTRACTOR SHALL PROVIDE A REMOTE ANNUNCIATOR TO REPEAT INDICATIONS
<br />OF THE FIRE ALARM CONTROL OR MONITORING PANEL. THE REMOTE ANNUNCIATOR SHALL RECEIVE POWER FROM THE FIRE ALARM
<br />CONTROL OR MONITORING PANEL.
<br />■
<br />NATIONAL ACCOUNT VENDOR LIST CURRENT AS OF 07/30/07
<br />1. STANDARD ELECTRIC MISCELLANEOUS ELECTRICAL EQUIPMENT AND LIGHTING
<br />14 JEWEL DRIVE
<br />WILMINGTON, MA 01887-0676
<br />PHONE: 978-661-1860
<br />W W W. STANDARDELECTRIC.COM
<br />2. LENNOX INDUSTRIES, INC. HVAC EQUIPMENT
<br />2100 LAKE PARK BLVD.
<br />RICHARDSON, TX 75080
<br />PHONE: 800-367-6285
<br />WWW.DAVELENNOX.COM
<br />3. FLOORTECH INDUSTRIES CARPET
<br />50 HUDSON RD.
<br />CANTON, MA 02021
<br />PHONE: 781-589-4569
<br />4. BESAM AUTOMATED ENTRANCE SYSTEMS AUTOMATIC DOORS
<br />i 84 TWIN RIVER DRIVE
<br />HIGHTSTOWN, NJ 08520-5213
<br />PHONE: 866-237-2687
<br />WWW.BESAM.COM
<br />5. BEST ACCESS SYSTEMS DOOR HARDWARE
<br />31 THORPE ROAD
<br />NEEDHAM, MA 02494
<br />PHONE: 800-562-5722 EXT. 230;
<br />781-449-6900
<br />WWW.BESTACCESS.COM
<br />6. REGIONAL VENDOR ASSIGNED BY STAPLES.
<br />NOTE: CONTACT STAPLES' ASSIGNED
<br />CONSTRUCTION PROJECT MANAGER TO VERIFY
<br />ASSIGNED VENDOR
<br />- AFA PROTECTIVE SYSTEMS
<br />PHONE: 781-848-6200
<br />- VECTOR SECURITY
<br />PHONE: 215-517-51 64
<br />7. REGIONAL VENDOR ASSIGNED BY STAPLES.
<br />NOTE: CONTACT STAPLES' ASSIGNED
<br />CONSTRUCTION PROJECT MANAGER TO VERIFY
<br />ASSIGNED VENDOR
<br />KIEFFER & CO., INC.
<br />585 BOND ST.
<br />LINCOLNSHIRE, IL 60069
<br />PHONE: 847-520-1255
<br />SECURITY/BURGLAR ALARM AND EQUIPMENT
<br />EXT. BUILDING SIGNAGE
<br />■
<br />1. LANDLORD'S GENERAL CONTRACTOR SHALL PROVIDE TO STAPLES PROJECT MANAGEMENT TEAM MINIMUM OF TWELVE (12)
<br />SITE/BUILDING CONDITION DIGITAL PHOTOGRAPHS, EVERY WEEK, LABELED AND DATED.
<br />2• THE LANDLORD'S GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS WITH STAPLES PROJECT
<br />MANAGEMENT TEAM BEFORE COMMENCING ANY PHASE OF THE WORK. NOTIFY STAPLES PROJECT MANAGEMENT TEAM OF ANY
<br />CONFLICTS DISCREPANCIES OR OMISSIONS PRIOR TO COMMENCEMENT OF THE CONTRACT WORK.
<br />3. ANY REFERENCE MADE TO CONTRACTORS, INCLUDING BUT NOT LIMITED TO L.L.C., G.C., OR E.C., INDICATES WORK WHICH IS
<br />THE SOLE RESPONSIBILITY OF THE LANDLORD'S GENERAL CONTRACTOR UNLESS SPECIFICALLY NOTED TO BE WORK
<br />PERFORMED BY STAPLES. SUBCONTRACTORS ARE THOSE INDIVIDUALS AND/OR COMPANIES PROVIDING SERVICES, PRODUCTS
<br />AND PORTIONS OF THE WORK DESCRIBED IN THE CONSTRUCTION DOCUMENTS UNDER DIRECT CONTRACT TO THE
<br />LANDLORD'S GENERAL CONTRACTOR.
<br />4` THE PROJECT RESPONSIBILITY SCHEDULE ON SHEET T-1 IS TO OUTLINE THE RESPONSIBILITY OF THE LANDLORD'S GENERAL
<br />CONTRACTOR AND STAPLES.
<br />5. PUBLICLY ACCESSIBLE PORTIONS OF THE BUILDING INCLUDING SIDEWALKS, ENTRY RAMPS, AND EXIT DOORS SHALL COMPLY
<br />AT A MINIMUM WITH THE AMERICANS WITH DISABILITIES ACT, TITLE 111, AND LOCAL ARCHITECTURAL BARRIER BOARDS.
<br />" " DETAILS REFERRED TO AS TYPICALSHALL BE CONSIDERED AS A TYPICAL_ CONDITION REPEATED THROUGHOUT THE PROJECT,
<br />,
<br />WHETHER REFERENCED OR NOT.
<br />I I THE EVENT F OMISSION F
<br />THESE DRAWINGS SHALL NOT BE SCALED FOR THE PURPOSES OF CONSTRUCTION. N E E EN O 0 SS ON 0
<br />7. E
<br />NECESSARY DIMENSIONS OR INFORMATION, LANDLORD'S GENERAL CONTRACTOR SHALL NOTIFY THE ARCHITECT FOR
<br />CLARIFICATION.
<br />8• LANDLORD'S GENERAL CONTRACTOR SHALL PROVIDE A FULL SET OF CONSTRUCTION DOCUMENTS TO ALL SUB -CONTRACTORS.
<br />ALL CROSS-REFERENCING SHALL BE THE SOLE RESPONSIBILITY OF THE LANDLORD'S GENERAL CONTRACTOR.
<br />9. UNLESS NOTED OTHERWISE, ALL DOORS ARE TO BE LOCATED AT 6" FROM INSIDE FACE OF PARTITION TO EDGE OF DOOR
<br />JAMB. (HINGE SIDE ONLY)
<br />10. INSTALL METAL TRIM ON ALL GYPSUM BOARD EDGES ABUTTING OTHER MATERIALS AND WHERE GYPSUM BOARD IS STOPPED
<br />SHORT OF OTHER MATERIALS TO FORM A REVEAL OR RECESS. USE METAL CORNER BEADS ON ALL EXTERIOR GYPSUM BOARD
<br />CORNERS.
<br />11. NECESSARY BLOCKING SHALL BE PROVIDED IN WALLS WHERE GRAB BARS, CORNICE TRIM, WOOD BASE COUNTER TOPS AND
<br />OTHER STAPLES PROVIDED COUNTERS REQUIRE A RIGID AND SECURE ATTACHMENT TO SAID WALL.
<br />12. ALL EXTERIOR WOOD BLOCKING OR LOCKING FASTENED TO CMU SHALL BE PRESSURE TREATED.
<br />13. SLOPE FLOOR TO DRAINS IN REST ROOMS, LOUNGE AND JANITOR AREA.
<br />14. ALL CMU WALL JOINTS SHALL BE TOOLED TO PROVIDE A ROUND JOINT ON BOTH SIDES OF CMU WALL.
<br />15. ALL CONDUIT, HANGERS, STUD TRACKS, ETC.... SHALL NOT BE ATTACHED TO THE ROOF DECK. ATTACH TO STRUCTURAL
<br />MEMBERS ONLY.
<br />16. THE INSTALLING CONTRACTOR SHALL MAINTAIN A STAMPED "APPROVED" SET OF DRAWINGS IN THE FIELD/SITE AT ALL TIMES
<br />DURING INSTALLATION AND CONSTRUCTION.
<br />u
<br />SYMBOLS (ARCHITECTURAL)
<br />RE COVERSHEET FOR SYMBOLS
<br />REFERENCE KEY
<br />RE: COVERSHEET FOR SYMBOLS
<br />z
<br />i
<br />w
<br />z'
<br />O
<br />z
<br />cf)
<br />cn
<br />w
<br />s�
<br />w
<br />w
<br />cn
<br />z
<br />o
<br />�Lm
<br />m
<br />rI
<br />NI
<br />II
<br />of
<br />o
<br />w
<br />A
<br />L6
<br />U-)
<br />co
<br />co
<br />Go
<br />co
<br />Lu
<br />N'
<br />N
<br />N
<br />of
<br />O
<br />co
<br />$R
<br />[If
<br />N
<br />[if
<br />0
<br />�
<br />C N
<br />w
<br />O
<br />�
<br />�
<br />(,� G7
<br />a
<br />o
<br />o
<br />T-1
<br />
|