HPD-21:2: 14 <br />1 Site Wiring <br />SCALE: 1' = 50'-0" <br />Site Lighting Luminaire Schedule <br />SYMBOL <br />LABEL <br />QTY <br />MANUF. <br />CATALOG <br />NUMBER <br />DESCRIPTION <br />LAMP <br />MOUNTING <br />LUMENS <br />LLF <br />WATTS <br />a{ <br />A <br />11 <br />KIM <br />WD18D4- <br />WALL DIRECTOR <br />40OW MH ED-28 CLEAR <br />WALL @ <br />40,000 <br />0.72 <br />400 <br />LIGHTING <br />40OMH-277 <br />HORIZ. POS, <br />21' AFG <br />KVF 1000M <br />(2 @ 180A) SQUARE AREA <br />ONE EACH 1000W CLEAR <br />POLE @ <br />000 <br />C <br />43 <br />LITHONIA <br />SYMFL <br />LIGHTS, FLAT LENS, <br />METAL HALIDE, BT-56 <br />35' AFG <br />110,000 <br />0.72 <br />2160 <br />SYMETRIC DISTRIBUTION <br />VERT, BASE UP POS. <br />p <br />KVF 1000M <br />(3 @ 90A) SQUARE AREA <br />ONE EACH 1000W CLEAR <br />POLE @ <br />Q�0 <br />D <br />5 <br />LITHONIA <br />SYMFL <br />LIGHTS, FLAT LENS, <br />METAL HALIDE, BT-56 <br />35' AFG <br />110,000 <br />0.72 <br />3240 <br />SYMETRIC DISTRIBUTION <br />VERT, BASE UP POS. <br />KVF 1000M <br />(3 @ 120A) SQUARE AREA <br />ONE EACH 1000W CLEAR <br />POLE @ <br />7 <br />E <br />2 <br />LITHONIA <br />SYMFL <br />LIGHTS, FLAT LENS, <br />METAL HALIDE, BT-56 <br />35' AFG <br />110,000 <br />I <br />0.72 <br />3240 <br />i <br />SYMETRIC DISTRIBUTION <br />VERT, BASE UP POS. <br />I <br />HPO$:8 <br />----------- <br />—A K11 <br />i <br />HPF-21:23 R <br />HPF-18:20 <br />16 <br />d. <br />i <br />� I <br />I <br />I <br />I I <br />\ I � <br />NL <br />INDICATES NON - <br />SHADE TREE <br />INDICATES <br />SHADETREE <br />CONCRETE POLE <br />WITH HAND HOLE. <br />(PROVIDE FUSING AT <br />BASE OF POLE) <br />GRADE OR 12 BARE COPPER <br />PAVING. GROUND WIRE. <br />III I — <br />0 <br />3/4'C.MIN. 9—m =I _I <br />(PVC) _—✓g°}g'-0" COPPER <br />C;UND ROD (DRIVEN). <br />Lighting Concrete Pole Detail <br />SCALE: NTS <br />WIRE SIZE UP THE POLE SHALL BE (AT MINIMUM) THE SAME <br />SIZE AS THE WIRE FEEDING THE POLE <br />POLE SHALL MEET THE REQUIREMENTS OF SECTION 1606 IN <br />THE FLORIDA BUILDING CODE 2004 W/ 2005 AMENDMENTS. <br />THE POLE SHALL BE DESIGNED AT 3 SECOND GUST WITH <br />MINIMUM EPA FOR POLE = 11.2 SFT <br />MINIMUM WEIGHT LOADING CAPACITY OF POLE = 212 LBS <br />I Site Liahtina Notes <br />KEY NOTES <br />1O CONTRACTOR TO PROVIDE (2) 3' PVC SCHEDULE 40 CONDUITS WITH PULL STRINGS TO WITHIN <br />5' OF PUBLIX STORE FOR COMMUNICATION LINES. CONTRACTOR TO COORDINATE EXACT <br />LOCATION OF CONDUIT ROUTING WITH PUBLIX DRAWINGS, PUBLIX FIELD REPRESENTATIVE, <br />AND WITH THE LOCAL UTILITY PROVIDER. <br />O PROPOSED LOCATION OF PUBLIX DEDICATED ELECTRICAL TRANSFORMER. COORDINATE <br />EXACT LOCATION WITH PUBLIX DRAWINGS, PUBLIX FIELD REPRESENTATIVE, AND WITH LOCAL <br />UTILITY PROVIDER. REFER TO PUBLIX ELECTRICAL DRAWINGS FOR INFORMATION ABOUT THE <br />REQUIREMENTS OF THE ELECTRICAL SERVICE FOR THE PUBLIX BUILDING. <br />O3 PROVIDE UNDER GROUND SERVICE FROM LOOP FEED UTILITY SYSTEM TO DEDICATED PUBLIX <br />TRANSFORMER (APPROXIMATE LOCATION). COORDINATE EXACT LOCATION OF CONDUITAND <br />WIRING WITH LOCAL UTILITY PROVIDER. <br />® PROPOSED LOCATION OF TRANSFORMER FOR BLDGS A & B. COORDINATE EXACT LOCATION <br />WITH RETAIL DRAWINGS AND WITH LOCAL UTILITY PROVIDER. REFER TO RETAIL ELECTRICAL <br />DWGS FOR THE REQUIREMENTS OF THE ELECTRICAL SERVICE FOR THE RETAIL BUILDING. <br />O5 PROPOSED LOCATION OF TRANSFORMER FOR BLDGS C & D. COORDINATE EXACT LOCATION <br />WITH RETAIL DRAWINGS AND WITH LOCAL UTILITY PROVIDER. REFER TO RETAIL ELECTRICAL <br />DWGS FOR THE REQUIREMENTS OF THE ELECTRICAL SERVICE FOR THE RETAIL BUILDING. <br />© PROPOSED LOCATION OF TRANSFORMER FOR BLDG F. COORDINATE EXACT LOCATION <br />WITH RETAIL DRAWINGS AND WITH LOCAL UTILITY PROVIDER. REFER TO RETAIL ELECTRICAL <br />DWGS FOR THE REQUIREMENTS OF THE ELECTRICAL SERVICE FOR THE RETAIL BUILDING. <br />O7 RETAIL METER CENTER, HOUSE PANEL, & TELEPHONE TERMINAL CABINET FOR BLDG B. <br />REFER TO RETAIL ELECTRICAL DWGS FOR EXACT LOCATION AND FOR THE REQUIREMENTS <br />OF THE ELECTRICAL AND COMMUNICATION SERVICES FOR THE RETAIL BUILDING. <br />® LOCATION OF CONDUIT STUB OUTS FOR FUTURE ELECTRICAL AND TELEPHONE SERVICES <br />FOR BLDG C. REFER TO RETAIL ELECTRICAL DRAWINGS FOR EXACT LOCATION AND FOR THE <br />REQUIREMENTS OF THE ELECTRICALAND COMMUNICATION SERVICES. <br />O RETAIL METER CENTER, HOUSE PANEL, & TELEPHONE TERMINAL CABINET FOR BLDG D. <br />REFER TO RETAIL ELECTRICAL DWGS FOR EXACT LOCATION AND FOR THE REQUIREMENTS <br />OF THE ELECTRICAL AND COMMUNICATION SERVICES FOR THE RETAIL BUILDING. <br />10 RETAIL METER CENTER, HOUSE PANEL, & TELEPHONE TERMINAL CABINET FOR BLDG F. <br />REFER TO RETAIL ELECTRICAL DWGS FOR EXACT LOCATION AND FOR THE REQUIREMENTS <br />OF THE ELECTRICALAND COMMUNICATION SERVICES FOR THE RETAIL BUILDING. <br />IQ SITE LIGHTING WIRED ON REGULAR CIRCUIT TO BLDG B HOUSE PANEL. REFER TO <br />RETAIL ELECTRICAL DWGS FOR CONDUIT SIZES, WIRE SIZES, AND EXACT CIRCUITING. <br />12 SITE LIGHTING WIRED ON REGULAR CIRCUIT TO BLDG C HOUSE PANEL. REFER TO <br />RETAIL ELECTRICAL DWGS FOR CONDUIT SIZES, WIRE SIZES, AND EXACT CIRCUITING. <br />13 SITE LIGHTING WIRED ON NIGHT LIGHT CIRCUIT TO BLDG D HOUSE PANEL. REFER TO <br />RETAIL ELECTRICAL DWGS FOR CONDUIT SIZES, WIRE SIZES, AND EXACT CIRCUITING. <br />14 SITE LIGHTING WIRED ON REGULAR CIRCUIT TO BLDG D HOUSE PANEL. REFERTO <br />RETAIL ELECTRICAL DWGS FOR CONDUIT SIZES, WIRE SIZES, AND EXACT CIRCUITING. <br />15 SITE LIGHTING WIRED ON NIGHT LIGHT CIRCUIT TO BLDG F HOUSE PANEL. REFER TO <br />RETAIL ELECTRICAL DWGS FOR CONDUIT SIZES, WIRE SIZES, AND EXACT CIRCUITING. <br />16 SITE LIGHTING WIRED ON REGULAR CIRCUIT TO BLDG F HOUSE PANEL. REFER TO <br />RETAIL ELECTRICAL DWGS FOR CONDUIT SIZES, WIRE SIZES, AND EXACT CIRCUITING. <br />17 SHOPPING CENTER MONUMENT SIGN WIRED TO BLDG D HOUSE PANEL. REFER TO <br />RETAIL ELECTRICAL DWGS FOR CONDUIT SIZES, WIRE SIZES, AND EXACT CIRCUITING. <br />18 SHOPPING CENTER MONUMENT SIGN WIRED TO BLDG F HOUSE PANEL. REFER TO <br />RETAIL ELECTRICAL DWGS FOR OONDUIT SIZES, WIRE SIZES, AND EXACT CIRCUITING. <br />19 RETAIL METER CENTER, HOUSE PANEL, & TELEPHONE TERMINAL CABINET FOR BLDG A. <br />REFER TO RETAIL ELECTRICAL DWGS FOR EXACT LOCATION AND FOR THE REQUIREMENTS <br />OF THE ELECTRICAL AND COMMUNICATION SERVICES FOR THE RETAIL BUILDING. <br />GENERAL NOTES <br />1. ALL NEW SITE LIGHTING TO BE WIRED TO THE RETAIL HOUSE PANEL. <br />2. ON POLES WHERE NIGHT LIGHTS (NQARE INDICATED. ONLY THE FIXTURE SPECIFIED <br />IS ON THE NL CIRCUIT. THE OTHER FIXTURE(S) IS (ARE) ONAREGULAR CIRCUIT. <br />3. ALL NEW IRRIGATION CONTROLS TO BE WIRED TO THE RETAIL HOUSE PANEL. <br />4. REFER TO THE RETAIL ELECTRICAL DRAWINGS FOR THE EXACT LOCATION OF THE RETAIL <br />METER CENTER AND HOUSE PANEL. <br />5. REFER TO THE RETAIL ELECTRICAL DRAWINGS FORALL RETAIL RISER DIAGRAMS, PANEL <br />SCHEDULES, CONDUIT SIZES, AND WIRE SIZES. <br />6. ALL WORK PERTAINING TO THE RETAIL BLDG TO BE COORDINATED WITH THE RETAIL DWGS. <br />7. ALL WORK PERTAINING TO THE PUBLIX BUILDING TO BE COORDINATED WITH THE PUBLIX <br />SHELL DRAWINGS AND THE PUBLIX FIELD REPRESENTATIVE. <br />8. ALL UTILITY WORK TO BE COORDINATED WITH THE LOCAL UTILITY PROVIDER. <br />9. ALL WORK SHOWN ON THE SITE ELECTRICAL DRAWINGS TO BE COORDINATED WITH THE <br />CIVIL, LANDSCAPE, AND IRRIGATION DRAWINGS AS WELLAS WITH ALL OTHER UTILITIES. <br />O <br />5= <br />i <br />a <br />0 <br />CU <br />W <br />O <br />CL <br />0 <br />r� <br />V <br />ca C 00 <br />U_jm <br />.L UCO CD <br />M <br />O <br />O .J <br />w <br />LLcu <br />LL <br />E <br />N <br />Q CDz •nnL C*4CD <br />E <br />�+MHfn <br />U <br />cn <br />0 <br />E <br />E <br />0 <br />U <br />L <br />C_ <br />C M <br />N <br />-�+ <br />CO LL c <br />�Y(a <br />W � O <br />a <br />°6 t U <br />z <br />A O <br />U) a U) <br />iU <br />0 <br />� <br />WYN� <br />a <br />} <br />�\ Q <br />Z N <br />O v <br />co <br />U CD <br />a cn <br />J <br />�w <br />O <br />�J J <br />z <br />O <br />U) <br />U <br />m <br />CO <br />H <br />Of <br />w <br />d <br />til <br />0 <br />ti <br />w <br />U <br />o <br />w� <br />LU <br />w <br />O <br />z <br />rn <br />o <br />O <br />N <br />H <br />c*� <br />o <br />z <br />O <br />W <br />w <br />m <br />a <br />o <br />o <br />v <br />E002 <br />