Ot-h — <br />1 Electrical Power Plan <br />Scale 1/8"=V-0" <br />MINIMUM <br />.c •. <br />UU- <br />EXISTING SECONDARY <br />ewer Plan Key Notes: <br />EXISTING J-BOX AND EMPTY 314" CONDUIT. EXTEND <br />CONDUIT AS NEEDED AND RUN NEW WIRES TO NEW <br />TENANT PANEL VIA TIME CLOCK. <br />EXISTING RTU TO BE WIRED BACK TO NEW TENANT PANEL <br />CONTRACTOR SHALL VERIFY THAT THERE IS AN EXISTING <br />SMOKE DUCT DETECTOR IN THE SUPPLY DUCT. IF THERE <br />ISN'T, REFER TO MECHANICAL GENERAL NOTE # 7 ON <br />SHEET M101. THE GC SHALL BE RESPONSIBLE FOR <br />COORDINATING THE EXACT SCOPE OF WORK REQUIRED <br />BETWEEN THE MECHANICAL SUB AND THE ELECTRICAL <br />SUB PRIOR TO BIDDING. NO CHANGE ORDERS WILL BE <br />APPROVED FOR FAILURE TO VERIFY EXISTING <br />CONDITIONS OR COORDINATE BETWEEN SUBS. <br />EXISTING FACTORY INSTALLED DISCONNECTS. FOR <br />POWER REQUIREMENTS TO RTU'S, RE: M101 AND <br />ELECTRICAL PANEL SCHEDULE ON THIS SHEET. <br />EXISTING FACTORY INSTALLED POWERED CONVENIENCE <br />OUTLET. INSTALLATION SHALL BE PER SECTION 210.63 OF <br />THE NEC. COORDINATE WITH MECHANICAL. <br />EXISTING TELEPHONE CONDUIT STUB IN TO REMAIN AS IS. <br />NO TELEPHONE TERMINAL BOARD OR RECEPTACLE <br />ADDED. THE TENANT SHALL BE RESPONSIBLE FOR <br />PULLING THE COMMUNICATION CABLE FROM THE <br />EXISTING TELEPHONE TERMINAL CABINET TO THE SPACE <br />AND FOR PROVIDING THE TELEPHONE TERMINAL BOARD <br />AS PART OF THE FUTURE TENANT WORK. <br />NEW LOCATION FOR NEW 200 AMP TENANT ELECTRICAL <br />PANEL. ROUTE EXISTING 4" CONDUIT STUB UP FROM THE <br />EXISTING LOCATION TO THIS POINT UNDER GROUND. <br />REFER TO RISER DIAGRAM ON THIS SHEET. <br />ALL FIRE ALARM EQUIPMENT IS SHOWN FOR REFERENCE <br />PURPOSES ONLY. FIRE ALARM DESIGN DRAWINGS SHALL <br />BE SUBMITTED BY TENANT BUILDOUT CONTRATOR, SIGNED <br />AND SEALED BY STATE OF FLORIDA LICENSED AND <br />REGISTERED ENGINEER. <br />RISER KEY NOTES: <br />1. EXISTING (4) # 3/0 & (1) # 3/0 G, IN EXISTING 2" CONDUIT <br />2. NEW (4) # 3/0 & (1) #6 G, IN EXISTING 2" CONDUIT. <br />3. EXISTING 4" TO 2" REDUCER. <br />4. NEW (4) # 3/0 & (1) # 6 G, IN EXISTING 4" CONDUIT. <br />5. NEW 4" TO 2" REDUCER AT THE TOP OF THE EXISTING <br />CONDUIT STUB IN. <br />EXISTING <br />1200 AMP <br />'DISCONNECT <br />3P i 4W <br />120/208V <br />NEMA 3R <br />_ <br />EXISTING GROUNND <br />T <br />Lighting Plan Key Notes: <br />11 EXISTING DECORATIVE SCONCE FIXTURES SHALL REMAIN <br />WIRED AS IS TO THE EXISTING HOUSE PANEL. <br />12 EXISTING REAR WALL MOUNTED LIGHT SHALL BE WIRED <br />TO THE NEW TENANT PANEL VIA A NEW LIGHT SWITCH. <br />Lighting General Notes: <br />1. VENDOR SHALL VERIFY ALL FIXTURE QUANTITIES. <br />2. VERIFY FIXTURE LOCATION, SEE REFLECTED CEILING PLAN. <br />3. MOUNTING HEIGHTS INDICATED ARE TO THE CENTER LINE OF <br />DEVICE OR FIXTURE UNLESS OTHERWISE NOTED. <br />4. ALL FIXTURES TO BE CENTERED ON 2X4 CEILING GRID U.O.N. <br />5. ALL FIXTURES TO BE PROVIDED BY, RECEIVED, STORED & <br />INSTALLED BY ELECTRICAL CONTRACTOR. <br />6. ELECTRICAL CONTRACTOR SHALL SUPPLY 10% ADDITIONAL <br />SPARE OF ALL LAMP TYPES TO BE LEFT AT JOB SITE AT END <br />OF JOB. <br />7. CIRCUIT BREAKERS USED AS SWITCHES IN 120V AND 277V <br />FLUORESCENT LIGHTING CIRCUITS SHALL BE LISTED AND <br />SHALL BE MARKED SWD OR HID. <br />2 Electrical Lighting Plan <br />Scale 1/8"=1'-O" <br />Light Fixture Schedule <br />TYPE <br />MANUFACTURER <br />CATALOG NO. <br />VOLT <br />LAMPS <br />MOUNTING & OPTION <br />NOTE <br />A <br />DAYBRITE <br />2TG8-3-32-01-UNV-1/3-EB <br />120 <br />17 <br />(3) 32W T8 <br />GRID MOUNTED <br />1-3,5-6 <br />C <br />NITE BRITES <br />WCR-050-M-MT <br />120 <br />- <br />EXISTING TO REMAIN <br />EM <br />BEGHELLI <br />XLP-S1 <br />120 <br />- <br />WALL MTD AT 9'-0"AFF <br />2 & 4 <br />X <br />BEGHELLI <br />VA4-R-SA <br />120 <br />1 LED (INCLUDED) <br />UNIVERSAL <br />2 & 4 <br />ALTERNATE FIXTURES MAY BE COOPER, LITHONIA, GENLYTE, HUBBELL, OR THOMAS. FIXTURE <br />SUBSTITUTIONS MUST BE APPROVED BY OWNER BEFORE THEY ARE SUBMITTED TO THE ENGINEER. <br />1. ALL FLUORESCENT LIGHTING FIXTURES SHALL 4. <br />ALL EMERGENCY, EXIT AND NIGHT LIGHT FIXTURES <br />HAVE ENERGY SAVING LAMPS AND ELECTRONIC <br />SHALL BE CONNECTED AHEAD OF LOCAL SWITCHES. <br />BALLASTS. <br />UNLESS OTHERWISE NOTED. <br />2. PROVIDE NECESSARY MOUNTING HARDWARE 5. <br />ALL ALTERNATE FIXTURES SHALL BE SUBMITTED <br />AND ACCESSORIES FOR ALL FIXTURES. <br />FOR PRIOR APPROVAL, SEE SPECIFICATIONS. <br />3. PROVIDE .125 MIN. THICK LENSES FOR 6. <br />CONTACT SESCO LIGHTING (407) 629-6100 DAN <br />FLUORESCENT FIXTURES. <br />SCHULMAN <br />6. NEW (4) # 3/0 & (1) # 6 GROUND IN NEW 2" CONDUIT. <br />7. NEW 7-DAY, 4 CIRCUIT PROGRAMMABLE TIME CLOCK <br />ALL WIRING SHALL BE COPPER ONLY. <br />CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS <br />PRIOR TO SUBMITTING BIDS. IF EXISTING CONDITIONS ARE <br />NOT AS SPECIFIED, CONTRACTOR SHALL NOTIFY THE <br />ARCHITECT / ENGINEER IMMEDIATELY. <br />EXISTING 12" X 12" WP WIREWAY WITH KEY TAPS <br />-1 ING <br />00 AMP <br />200 AMP <br />! 1 <br />O, <br />EXISTING <br />200 AMP <br />DIS- EXISTING <br />CONNECT L 400 AMP <br />(FUSED) DISCONNECT <br />200 <br />.3. <br />200 <br />3 Building Power Riser Diagram <br />SCALE: NTS <br />EX <br />Electrical Legend <br />NOTES: 1. <br />MOUNTING HEIGHTS SHOWN ARE MAX. / MIN. HANDICAP ACCESSIBILITY <br />2. NOT ALL DEVICES SHOWN IN LEGEND ARE REQUIRED. RE: PLANS <br />STANDARDS - THEY SHALL NOT BE ALTERED W / 0 WRITTEN AUTHORIZATION. & DETAILS FOR ITEMS WHICH APPLY TO THIS PROJECT. <br />FLUORESCENT LIGHT FIXTURE, LETTER INDICATES TYPE. SEE FIXTURE <br />A-1,3 CONDUIT RUN CONCEALED IN WALLS BELOW SLAB, OR CEILING SPACES. <br />AM oR A®a <br />SCHEDULE. LOWER CASE LETTER INDICATES SWITCH (IF USED) <br />ARROWS INDICATE HOMERUN. SMALL HASHMARKS INDICATE NUMBER OF <br />HOT CONDUCTORS, AND LARGE HASHMARK INDICATES NEUTRAL.SUBSCRIPT <br />FLUORESCENT STRIP LIGHT, LETTER INDICATES TYPE. SEE FIXTURE <br />INDICATES PANEL AND CIRCUIT NUMBERS. GROUND <br />SCHEDULE. LOWER CASE LETTER INDICATES SWITCH (IF USED) <br />CONDUCTOR REQUIRED IN ALL CONDUITS BUT NOT INDICATED. <br />O oR 0 <br />SURFACE MOUNTED LIGHT, LETTER INDICATES TYPE. SEE FIXTURE <br />SCHEDULE. LOWER CASE LETTER INDICATES SWITCH (IF USED) <br />A-37:39:41 SUBSCRIPT INDICATES PANEL -AND NUMBERS WITH COLONS <br />Q B � B <br />INCANDESCENT OR HID LIGHT FIXTURE, LETTER INDICATES TYPE <br />INDICATE 2 OR 3 POLE CIRCUITS. <br />SEE LIGHT FIXTURE SCHEDULE TO CONFIRM TYPE AND MOUNTING. <br />LCI DISCONNECT SWITCH <br />Q C -Q C <br />WALL BRACKET LIGHT FIXTURE, LETTER INDICATES TYPE SEE <br />LIGHT FIXTURE SCHEDULE TO CONFIRM TYPE AND MOUNTING. <br />100/3/60 DISCONNECT DESIGNATION (SIZE/POLES/FUSE) "NF" INDICATES <br />NL <br />NIGHT LIGHT FIXTURE (NL) <br />NON -FUSED; "DE" INDICATES DUAL ELEMENT FUSES. <br />®X <br />EXIT LIGHT SHADE AREA INDICATES DIRECTION) LETTER INDICATES TYPE <br />( <br />EF MOTOR PERMANENTLY CONNECTED WITH FLEXIBLE CONDUIT <br />OR <br />SEE LIGHT FIXTURE SCHEDULE TO CONFIRM TYPE AND MOUNTING. <br />(HORSEPOWER EQUIPMENT INDICATED) <br />OjEk <br />BATTERY POWERED EMERGENCY LIGHT <br />THERMOSTAT. PROVIDE SINGLE GANG BOX WITH 112" C. STUBBED <br />OT INTO CEILING SPACE, MOUNT 60" A.F.F. U.O.N. (COORDINATE WITH <br />,jo." <br />TRACK LIGHTING AND TRACK, FOR INFORMATION ON TRACK SEE <br />MECHANICAL DRAWINGS PRIOR TO ROUGH -IN) <br />LIGHT FIXTURE SCHEDULE TO CONFIRM TYPE AND MOUNTING. <br />TELEPHONE WALL OUTLET, PROVIDE SINGLE GANG BOX WITH 3/4" <br />WALL WASHER FIXTURE. (SHADE AREA INDICATES DIRECTION) SEE <br />v CONDUIT WITH PULL WIRE AND INSULATING BUSHING STUBBED INTO <br />LIGHT FIXTURE SCHEDULE TO CONFIRM TYPE AND MOUNTING. <br />CEILING SPACE. MOUNT BOX 18" A.F.F. U.O.N. <br />SINGLE POLE SWITCH, LOWER CASE LETTER INDICATES LIGHTS <br />CONTROLLED. LETTER NOT SHOWN IF SELF EVIDENT. MOUNT <br />COMPUTER OUTLET. MOUNT BOX Q 18" A.F.F. U.O.N. <br />a <br />48" A.F.F. U.O.N. <br />F <br />SINGLE POLE SWITCH. FAN CONTROLLER, MOUNT 48" A.F.F. U.O.N. <br />O CEILING SPEAKERS MTD. AND WIRED PER AEI MUSIC NETWORK, <br />S <br />3 <br />3-WAY SWITCH, FOR CONTROLLING LIGHTS FROM TWO DIFFERENT POINTS. <br />INC. (800-274-9298) <br />® <br />TWO GANG FLOOR OUTLET BOX. ONE QUADPLEX ISOLATED GROUND <br />O CEILING MTD. SENSOR DEVICE <br />RECEPTACLE AND ONE COMPUTER OUTLET. <br />a. <br />WIREMOLD WALKER INFLOOR SYSTEMS. RC4 FLUSH QUAD POKE <br />❑F FIRE ALARM PULL STATION: EDWARDS #SIGA-270 <br />THRU SERIES WITH FOUR MULTIMEDIA COMMUNICATION LOCATIONS <br />WIREMOLD WALLSOURCE MULTIPLE SERVICE BOX. <br />F HORN/STROBE: EDWARDS #692-8A-HSW <br />Q <br />QUADPLEX FLOOR RECEPTACLE OUTLET. <br />> <br />QUADPLEX RECEPTACLE OUTLET. <br />O SMOKE DETECTOR: EDWARDS #ISIGA-PS <br />QUADPLEX RECEPTACLE OUTLET MOUNTED ABOVE COUNTER TOP U.O.N. <br />O HEAT DETECTOR: EDWARDS #SIGA-HRS <br />O <br />DUPLEX FLOOR RECEPTACLE OUTLET. <br />FACP PANEL: SIEMEN CYRBURUS MODEL #PXL <br />DUPLEX RECEPTACLE, MOUNT 18" AFF LION <br />& <br />DUPLEX RECEPTACLE MOUNTED ABOVE COUNTER HEIGHT U.O.N. <br />EF BATH ROOM FAN LIGHT (BROAN S150L) <br />GROUND FAULT INTERRUPTER RECEPTACLE, LEVITON #6898-I, MOUNT <br />�GFI <br />ABOVE COUNTER HEIGHT U.O.N. <br />I.G. <br />ABBREVIATIONS <br />DUPLEX RECEPTACLE, ISOLATED GROUND TYPE, LEVITON #5362-IGI <br />MOUNTED ABOVE COUNTER HEIGHT. U.O.N. <br />ACC-CU CONDENSING UNIT LB LOCK BREAKER <br />AFF ABOVE FINISH FLOOR NF NON -FUSED <br />I.G. <br />DUPLEX RECEPTACLE, ISOLATED GROUND TYPE, LEVITON #5362-IGI <br />MOUNT AT 18" AFF UON <br />AFG ABOVE FINISH GRADE NIC NOT IN CONTRACT <br />DUPLEX RECEPTACLE, MOUNTED ABOVE STOREFRONT WINDOWS <br />A/H-AHU AIR HANDLING UNIT NL NIGHT LIGHT <br />C/T CURRENT TRANSFORMER NTS NOT TO SCALE <br />SINGLE RECEPTACLE, MOUNTED AT HEIGHT NOTED ON PLANS <br />DE DUAL ELEMENT FUSE OS OCCUPANCY SENSORS <br />EC EMPTY CONDUIT PC PULL CHAIN <br />® <br />SPECIAL PURPOSE RECEPTACLE OUTLET <br />E/F-EF EXHAUST FAN RTU ROOF TOP UNIT <br />JO <br />JUNCTION BOX (FLUSH MOUNT IN FINISHED AREAS U.O.N.) <br />EG EQUIPMENT GROUND TTB TELEPHONE TERMINAL BOARD <br />a <br />LIGHTING, POWER, FACP PANELBOARD OR TELE. TERM. CABINET. <br />EM EMERGENCY LIGHT TTC TELEPHONE TERMINAL CABINET <br />U <br />EWC ELECTRIC WATER COOLER TYP TYPICAL <br />MSB/MDP <br />MAIN SWITCHBOARD OR MAIN DISTRIBUTION PANEL <br />EWH ELECTRIC WATER HEATER LION UNLESS OTHERWISE NOTED <br />CONDUIT CONCEALED IN WALL, BELOW SLAB, OR ABOVE CEILING. <br />EX EXISTING DEVICE TO REMAIN VTC VIA TIME CLOCK <br />f <br />FACP FIRE ALARM CONTROL PANEL WP WEATHERPROOF <br />CONDUIT EXPOSED ON WALL OR CEILING. <br />GFI GROUND FAULT INTERRUPTER X EXIT LIGHT <br />AD <br />IG ISOLATED GROUND <br />FLEXIBLE CONDUIT NOT TO EXCEED 6 FEET IN LENGTH <br />NOTE: MOUNTING HEIGHTS NOTED ARE TO BOTTOM OF DEVICE SHOWN LION <br />� <br />MANUFACTURER: SQUARE 0'1NO' <br />NAME, PANEL'B8' <br />MAIIN BREAKER, 3 PHASE <br />-- - <br />g <br />MAIN LUGS: 200A 4 WIRE <br />PROJECT NAME. ZEPHYR COMMONS <br />z <br />K.A,I,C : 42 1201208 VOLTS <br />PROJECT NUMBER_ 206319 <br />� <br />MOUNTED SURFACE <br />FED FROM: E>3S11NG VVIREVVAY <br />0 <br />N <br />N <br />c��gg LD <br />19 <br />C <br />CKT <br />' O <br />LOAD,�PHASE (KVA.) CIRCUIT BREAKER LOAD/PHASE (KVA) <br />O <br />CKT O <br />a <br />T <br />IDENTIFICATION <br />NO . <br />V IREICOND <br />i D <br />D <br />WIRE/ COND ICENTIFICAT10fiI <br />T <br />INC. <br />U <br />E <br />E <br />E <br />E <br />as <br />A B C TRIP P <br />P TRIP A <br />8 <br />4 <br />..............0 <br />1 EXIT, EMIR, NITE LG <br />_ <br />2#12. 1#12G, 3/4"C <br />L <br />0.22 20 _ 1 <br />20 1.25 L <br />2#12 1#1M 3l4"C TENANT SIGNAGE <br />3. <br />a <br />.1 <br />3 EX . <br />REAR LGT <br />2#12, 1#12G., 3/4"C <br />L <br />0,05 20 1 <br />1 20 1.27 R <br />2#12, 1#12G, 4"C SHOW WI1NDOVV RECE <br />4 <br />5 RR LIGHTS & EF. <br />2#12, 1#12G 3 4�C <br />L <br />1,14 20 1 <br />1 20 1.27 R <br />2#1Z 1#1.2G, 4"C SHOW WINDOW RECE <br />5 <br />E <br />a <br />4 <br />7 2 X4 LIGHTS <br />2#12, 1#12G, 3/4"C <br />L <br />1.14 20 1 <br />1 20 0.72 R, <br />2#42,: 1#12G, 314�C RECEPTACLES <br />g <br />4 <br />9 2 X4 LIGHTS <br />2#12, 1#12G, 3/4"C <br />L <br />1:14 20 1 <br />1 20 = fJ.72. R <br />21'#12, 1#12G, 3/4"C RECEPTACLES <br />10 <br />1': 20 015 R <br />2#42, 1#12 , 3/4"C EV C <br />12 <br />13 <br />14 <br />e <br />a <br />15 <br />17 <br />- - _ <br />y <br />1 <br />19 <br />=_ - = <br />20 <br />U <br />21 <br />22 <br />l" <br />23 <br />24 <br />5 <br />28 <br />27 <br />_ - <br />= _ <br />28 <br />2330, <br />............... <br />_— <br />31 <br />_ _ �' <br />�s.. _-- <br />32 <br />E <br />33 <br />tl4;1 �. <br />34 <br />2 <br />35 <br />=36 <br />39 <br />3 35 3,02 C ; 1#1€ G, 314"C 4 TON RTU <br />41 <br />- =02 C <br />42 <br />1.4 1 1,2 1,1 <br />5.0 5.0 5.0 <br />TOTAL KVA PHASE A. 6.35 <br />TOTAL. CONNECTED KVA. 18..73 <br />m <br />TOTAL KVA. PHASE B-, 8.20 <br />TOTAL. CONNECTED AMPS: 51.99 <br />TOTAL KVA PHASE C. 5.18 <br />TOTAL. DEMAND KVA 19.97 <br />TOTAL DEMAND AMPS: 55.42 <br />a <br />0 <br />COW LOAD DBAkND DMAI <br />(KVA) FACTS LOAD(KVA) <br />m <br />GENERAL <br />a <br />LIGHTING (L) 4.94 1.25 6.175 <br />SQUARE FOOT: LIGHTING LOAD. <br />VA SIF <br />g <br />RECEPTACLES(4,3 NEC 4, 7 3 <br />a <br />A/C .HEATING (H) 0 1.00 0 * ` <br />` LIGHTING DEMAND LOAD IS BASED ON THE LARGER OF THE TWO <br />o <br />A.TC COOLING (C) 9,06 too 9,0 <br />(CONNECTED VS. TABLE 220,3 , NEC 20>02.) <br />KITCHEN EQUIPENT (K) 0 0 <br />0 <br />LARGEST MOTOR I s1) 0 125 0 <br />"LARGER A/C LOAD., 9.015 KVA. <br />" <br />OTHER (0) � 1,00 0 <br />(TO LENGTH � KVA <br />NOTES, 1) PROVIDE LOCKED CIRCUIT BREAKER 2) PROVIDE HACR RATED CIRCUIT SNEAKER 3) VIA TENANTTIME E CLOCK 4) NFPA 70.05 240.83 (D) COMPLIANT <br />V <br />C <br />CD <br />C <br />O <br />0- <br />0 <br />L_ <br />0 L11 <br />cuZ00 <br />c�Qco <br />^♦ 01 <br />.^♦0LL <br />w Q Q <br />Ewa <br />w �M1-- <br />J <br />U <br />V/ <br />C <br />0 <br />E <br />0 <br />U <br />L <br />Nm <br />-+--+ <br />C� <br />C� <br />OC)� <br />m m <br />Q <br />'� J <br />LL <br />�gy <br />V/p <br />JJJ <br />m J <br />J = <br />JLU <br />Z <br />C _ <br />w <br />0 <br />N <br />d <br />n4a <br />i <br />.0 <br />J <br />CU <br />L <br />0 <br />0- <br />vi <br />W <br />c- <br />U) <br />J <br />CU <br />U <br />LU <br />U <br />Al <br />F- <br />W <br />W <br />U) <br />LU <br />w <br />U) <br />H <br />w <br />a <br />Ln <br />N <br />pl <br />O <br />�W <br />Q <br />O <br />W <br />N <br />J <br />W <br />Q <br />� <br />Cf) <br />; <br />Z <br />rn� <br />o <br />M <br />C:) <br />U <br />co <br />Z <br />N <br />LU <br />N <br />¢ <br />O <br />H <br />W <br />o <br />a <br />v <br />E101 <br />