Laserfiche WebLink
1.4 <br />PROJECT CONDITIONS <br />3.2 <br />CLEANING AND PROTECTING <br />A. <br />Store materials not in use in tightly covered containers in a well -ventilated area at a minimum ambient temperature of 45 deg F. <br />A. <br />At the end of each workday, remove empty cans, rags, rubbish, and other discarded paint materials from Project site. <br />Maintain storage containers in a clean condition, free of foreign materials and residue. <br />B. <br />Protect work of other trades, whether being painted or not, against damage from painting. Correct damage by cleaning, repairing <br />B. <br />Apply waterborne paints only when temperatures of surfaces to be painted and surrounding air are between 50 and 90 deg F. <br />or replacing, and repainting, as approved by Architect. <br />C. <br />Apply solvent -thinned paints only when temperatures of surfaces to be painted and surrounding air are between 45 and 95 deg F <br />C. <br />Provide "Wet Paint" signs to protect newly painted finishes. After completing painting operations, remove temporary protective <br />wrappings provided by others to protect their work. <br />1. After work of other trades is complete, touch up and restore damaged or defaced painted surfaces. Comply with procedures <br />D. <br />Do not apply paint in snow, rain, fog, or mist; or when relative humidity exceeds 85 percent; or at temperatures less than 5 deg F <br />specified in PDCA PI. <br />above the dew point; or to damp or wet surfaces. <br />3.3 <br />INTERIOR PAINT SCHEDULE <br />1.5 <br />EXTRA MATERIALS <br />A. <br />Gypsum Board: <br />A. <br />Furnish extra paint materials from the same production run as the materials applied and in the quantities described below. Package <br />1. Acrylic Finish: Two finish coats over a primer. <br />with protective covering for storage and identify with labels describing contents. Deliver extra materials to Owner. <br />1. Quantity: 3 percent, but not less than 1 gal. or 1 case, as appropriate, of each material and color applied. <br />a. Primer: Interior gypsum board primer. <br />b. Finish Coats: See section 2.5. <br />PART 2 - <br />PRODUCTS <br />B. <br />Wood and Hardboard: <br />1. Acrylic -Enamel Finish: Two finish coats over a primer. <br />2.1 <br />MANUFACTURERS <br />a. Primer: Interior wood primer for acrylic -enamel and semigloss alkyd -enamel finishes. <br />b. Finish Coats: See section 2.5. <br />A. <br />Available Products: Subject to compliance with requirements, products that may be incorporated into the Work include, but are <br />not limited to, products listed in other Part 2 articles. <br />END OF <br />SECTION 0"00 <br />B. <br />Products: Subject to compliance with requirements, provide one of the products listed in other Part 2 articles. <br />C. <br />Manufacturers' Names: Shortened versions (shown in parentheses) of the following manufacturers' names are used in other Part 2 <br />articles: <br />1. Benjamin Moore & Co. (Benjamin Moore). <br />2. ICI Dulux Paint Centers (ICI Dulux Paints). <br />3. Sherwin-Williams Co. (Sherwin-Williams). <br />2.2 PAINT MATERIALS, GENERAL <br />A. Material Compatibility: Provide block fillers, primers, and finish -coat materials that are compatible with one another and with <br />the substrates indicated under conditions of service and application, as demonstrated by manufacturer based on testing and field <br />experience. <br />B. Material Quality: Provide manufacturer's best -quality paint material of the various coating types specified that are factory for- <br />mulated and recommended by manufacturer for application indicated. Paint -material containers not displaying manufacturer's <br />product identification will not be acceptable. <br />C. Colors: As indicated by manufacturer's designations. <br />2.3 PREPARATORY COATS <br />A. Interior Primer: Interior latex -based or alkyd primer of finish coat manufacturer and recommended in writing by manufacturer for <br />use with finish coat and on substrate indicated. <br />1. Ferrous -Metal Substrates: Quick drying, rust -inhibitive metal primer. <br />2. Zinc -Coated Metal Substrates: Galvanized metal primer. <br />3. Where manufacturer does not recommend a separate primer formulation on substrate indicated, use paint specified for finish <br />coat. <br />2.4 INTERIOR FINISH COATS <br />A. Interior Low -Luster Acrylic Enamel: <br />1. Benjamin Moore; Moorcraft Super Spec Latex Eggshell Enamel No. 274. <br />2. ICI Dulux Paints; 1402 series Dulux Professional Acrylic Eggshell Interior Wall & Trim Enamel. <br />3. Sherwin-Williams; ProMar 200 Interior Latex Egg -Shell Enamel B20W200 Series. <br />PART 3 - EXECUTION <br />3.1 APPLICATION <br />A. Comply with procedures specified in PDCA P4 for inspection and acceptance of surfaces to be painted. <br />B. Coordination of Work: Review other Sections in which primers are provided to ensure compatibility of the total system for various <br />substrates. On request, furnish information on characteristics of finish materials to ensure use of compatible primers. <br />C. Remove hardware and hardware accessories, plates, machined surfaces, lighting fixtures, and similar items already installed that <br />are not to be painted. If removal is impractical or impossible because of size or weight of the item, provide surface -applied protec- <br />tion before surface preparation and painting. <br />1. After completing painting operations in each space or area, reinstall items removed using workers skilled in the trades <br />involved. <br />D. Surface Preparation: Clean and prepare surfaces to be painted according to manufacturer's written instructions for each particular <br />substrate condition and as specified. <br />1. Provide barrier coats over incompatible primers or remove and reprime. <br />2. Cementitious Materials: Remove efflorescence, chalk, dust, dirt, grease, oils, and release agents. Roughen as required to <br />remove glaze. If hardeners or sealers have been used to improve curing, use mechanical methods of surface preparation. <br />3. Wood: Clean surfaces of dirt, oil, and other foreign substances with scrapers, mineral spirits, and sandpaper, as required. <br />Sand surfaces exposed to view smooth and dust off. <br />a. Scrape and clean small, dry, seasoned knots, and apply a thin coat of white shellac or other recommended knot sealer <br />before applying primer. After priming, fill holes and imperfections in finish surfaces with putty or plastic wood filler. <br />Sand smooth when dried. <br />b. Prime, stain, or seal wood to be painted immediately on delivery. Prime edges, ends, faces, undersides, and back <br />sides of wood, including cabinets, counters, cases, and paneling. <br />C. If transparent finish is required, backprime with spar varnish. <br />d. Backprime paneling on interior partitions where masonry, plaster, or other wet wall construction occurs on back <br />side. <br />e. Seal tops, bottoms, and cutouts of unprimed wood doors with a heavy coat of varnish or sealer immediately on deliv- <br />ery. <br />4. Ferrous Metals: Clean ungalvanized ferrous -metal surfaces that have not been shop coated; remove oil, grease, dirt, loose <br />mill scale, and other foreign substances. Use solvent or mechanical cleaning methods that comply with SSPC's recommen- <br />dations. <br />a. Blast steel surfaces clean as recommended by paint system manufacturer and according to SSPC-SP 6/NACE No. 3. <br />b. Treat bare and sandblasted or pickled clean metal with a metal treatment wash coat before priming. <br />C. Touch up bare areas and shop -applied prime coats that have been damaged. Wire -brush, clean with solvents recom- <br />mended by paint manufacturer, and touch up with same primer as the shop coat. <br />5. Galvanized Surfaces: Clean galvanized surfaces with nonpetroleum-based solvents so surface is free of oil and surface <br />contaminants. Remove pretreatment from galvanized sheet metal fabricated from coil stock by mechanical methods. <br />E. Material Preparation: <br />1. Maintain containers used in mixing and applying paint in a clean condition, free of foreign materials and residue. <br />2. Stir material before application to produce a mixture of uniform density. Stir as required during application. Do not stir <br />surface film into material. If necessary, remove surface film and strain material before using. <br />F. Exposed Surfaces: Include areas visible when permanent or built-in fixtures, grilles, convector covers, covers for finned -tube <br />radiation, and similar components are in place. Extend coatings in these areas, as required, to maintain system integrity and pro- <br />vide desired protection. <br />1. Paint surfaces behind movable equipment and furniture the same as similar exposed surfaces. Before final installation of <br />equipment, paint surfaces behind permanently fixed equipment or furniture with prime coat only. <br />2. Paint interior surfaces of ducts with a flat, nonspecular black paint where visible through registers or grilles. <br />3. Paint back sides of access panels and removable or hinged covers to match exposed surfaces. <br />4. Finish exterior doors on tops, bottoms, and side edges the same as exterior faces. <br />5. Finish interior of wall and base cabinets and similar field -finished casework to match exterior. <br />G. Sand lightly between each succeeding enamel or varnish coat. <br />H. Scheduling Painting: Apply first coat to surfaces that have been cleaned, pretreated, or otherwise prepared for painting as soon as <br />practicable after preparation and before subsequent surface deterioration. <br />1. Omit primer over metal surfaces that have been shop primed and touchup painted. <br />2. If undercoats, stains, or other conditions show through final coat of paint, apply additional coats until paint film is of uniform <br />finish, color, and appearance. <br />I. Application Procedures: Apply paints and coatings by brush, roller, spray, or other applicators according to manufacturer's written <br />instructions. <br />J. Minimum Coating Thickness: Apply paint materials no thinner than manufacturer's recommended spreading rate. Provide total <br />dry film thickness of the entire system as recommended by manufacturer. <br />K. Mechanical and Electrical Work: Painting of mechanical and electrical work is limited to items exposed in equipment rooms and <br />occupied spaces. <br />L. Block Fillers: Apply block fillers to concrete masonry block at a rate to ensure complete coverage with pores filled. <br />M. Prime Coats: Before applying finish coats, apply a prime coat, as recommended by manufacturer, to material that is required to <br />be painted or finished and that has not been prime coated by others. Recoat primed and sealed surfaces where evidence of suction <br />spots or unsealed areas in first coat appears, to ensure a finish coat with no burn -through or other defects due to insufficient seal- <br />ing. <br />N. Pigmented (Opaque) Finishes: Completely cover surfaces as necessary to provide a smooth, opaque surface of uniform finish, <br />color, appearance, and coverage. Cloudiness, spotting, holidays, laps, brush marks, runs, sags, ropiness, or other surface imperfec- <br />tions will not be acceptable. <br />O. Transparent (Clear) Finishes: Use multiple coats to produce a glass -smooth surface film of even luster. Provide a finish free of <br />laps, runs, cloudiness, color irregularity, brush marks, orange peel, nail holes, or other surface imperfections. <br />P. Stipple Enamel Finish: Roll and redistribute paint to an even and fine texture. Leave no evidence of rolling, such as laps, irregu- <br />larity in texture, skid marks, or other surface imperfections. <br />"E <br />Q <br />L <br />J <br />00 <br />d� <br />z <' <br />1 <br />:> <br />'w LL <br />rn <br />LL, <br />co <br />Ir <br />w <br />a <br />4 <br />0 <br />w <br />S <br />CC <br />00 <br />Q <br />N <br />w <br />In <br />m <br />U <br />rni <br />0 <br />0l <br />W <br />w <br />ch <br />rn <br />Y <br />Cn <br />w <br />p <br />CM <br />J <br />N <br />N <br />CM <br />C3 <br />m <br />= <br />B5 TENANT BUILD OUT <br />A005 <br />