1.3 QUALITY ASSURANCE <br />A. Quality Standard: Comply with NWWDA I.S.1-A, "Architectural Wood Flush Doors." Delete paragraph and subparagraph below <br />if no fire -rated doors. <br />B. Fire -Rated Wood Doors: Doors that are listed and labeled by a testing and inspecting agency acceptable to authorities having <br />jurisdiction, for fire ratings indicated. <br />PART 2 - PRODUCTS <br />2.1 MANUFACTURERS <br />A. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated <br />into the Work include, but are not limited to, the following: <br />1. Ampco Products, Inc. <br />2. Marlite. <br />3. Mohawk Flush Doors, Inc. <br />4. Weyerhaeuser Company. <br />2.2 DOOR CONSTRUCTION <br />A. Doors for Opaque Finish: <br />1. Grade: Custom. <br />2. Faces for Exterior Doors: Medium -density overlay. <br />3. Faces for Interior Doors: Any closed -grain hardwood of mill option. <br />B. Hollow -Core Doors: <br />1. Core: Institutional hollow core. <br />2. Finish: Prefinished Factory <br />3. Frame: Prehung. <br />C. Blocking: For hollow -core doors, provide blocking as needed to eliminate through -bolting hardware. <br />D. Provide doors with glued -block <br />2.3 FABRICATION <br />A. Fabricate doors in sizes indicated for Project -site fitting. <br />B. Factory fit doors to suit frame -opening sizes indicated. Comply with clearance requirements of referenced quality standard for <br />fitting. <br />C. Factory machine doors for hardware that is not surface applied. <br />PART 3 - EXECUTION <br />3.1 INSTALLATION <br />A. Install doors to comply with manufacturer's written instructions, referenced quality standard, and as indicated. <br />B. Factory -Fitted Doors: Align in frames for uniform clearance at each edge. <br />C. Factory -Finished Doors: Restore finish before installation if fitting or machining is required at Project site. <br />END OF SECTION 08211 <br />SECTION 09260 - GYPSUM BOARD ASSEMBLIES <br />PART 1 - GENERAL <br />1.1 SUMMARY <br />A. This Section includes the following: <br />1. Interior gypsum wallboard. <br />2. Exterior gypsum board panels for ceilings and soffits. <br />3. Non -load -bearing steel framing. <br />1.2 SUBMITTALS <br />A. Product Data: For each product indicated. <br />B. Samples: For each textured finish indicated and on same backing indicated for Work upon request of Architect. <br />1.3 QUALITY ASSURANCE <br />A. Fire -Test -Response Characteristics: For gypsum board assemblies with fire -resistance ratings, provide materials and construction <br />identical to those tested in assembly indicated according to ASTM E 119 by an independent testing and inspecting agency accept- <br />able to authorities having jurisdiction. <br />B. Sound Transmission Characteristics: For gypsum board assemblies with STC ratings, provide materials and construction identical <br />to those tested in assembly indicated according to ASTM E 90 and classified according to ASTM E 413 by a qualified independent <br />testing agency. <br />PART 2 - PRODUCTS <br />2.1 MANUFACTURERS <br />A. In other Part 2 articles where subparagraph titles below introduce lists, the following requirements apply for product selection: <br />1. Available Products: Subject to compliance with requirements, products that may be incorporated into the Work include, but <br />are not limited to, the products specified. <br />2.2 STEEL FRAMING <br />A. Steel Framing, General: Comply with ASTM C 754 for conditions indicated. <br />1. Steel Sheet Components: Metal complying with ASTM C 645 requirements. <br />a. Protective Coating: <br />1) Interior Applications: ASTM A 653/A 653M, G40, hot -dip galvanized. <br />2) Exterior Applications: ASTM A 653/A 653M, G60, hot -dip galvanized zinc coating. <br />B. Suspended Ceiling and Soffit Framing: <br />1. Tie Wire: ASTM A 641/A 641M, Class 1 zinc coating, soft temper, 0.0625-inch- diameter wire, or double strand of 0.0475- <br />inch-diameter wire. <br />2. Hanger Attachments to Concrete: <br />a. Powder -Actuated Fasteners: Suitable for application indicated, fabricated from corrosion -resistant materials, with <br />clips or other devices for attaching hangers of type indicated, and capable of sustaining, without failure, a load equal <br />to 10 times that imposed by construction as determined by testing according to ASTM E 1190 by a qualified indepen- <br />dent testing agency. <br />3. Wire Hangers: ASTM A 641/A 641M, Class 1 zinc coating, soft temper, 0.162-inch diameter. <br />4. Carrying Channels: Cold -rolled, commercial -steel sheet with a base metal thickness of 0.0538 inch, a minimum 1/2-inch- <br />wide flange, and in depth indicated. <br />5. Furring Channels (Furring Members): <br />a. Steel Studs: ASTM C 645, in depth indicated. <br />b. " Z" Shaped, Rigid Furring Channels: ASTM C 645, 1 1/2 inch deep. <br />C. Grid Suspension System for Interior Ceilings: ASTM C 645, direct -hung system composed of main beams and cross -furring <br />members that interlock. <br />1. Products: <br />a. Armstrong World Industries, Inc.; Furring Systems/Drywall. <br />b. Chicago Metallic Corporation; Fire Front 630 System. <br />C. USG Interiors, Inc.; Drywall Suspension System. <br />D. Partition and Soffit Framing: <br />1. Steel Studs and Runners: ASTM C 645, in depth indicated. <br />2. Deep -Leg Deflection Track: ASTM C 645 top runner with 2-inch-deep flanges. <br />3. Flat Strap and Backing Plate: Steel sheet for blocking and bracing in length and width indicated. <br />a. Minimum Base Metal Thickness: 0.0179 inch or as indicated. <br />4. Cold -Rolled Channel Bridging: 0.0538-inch bare steel thickness, with minimum 1/2-inch-wide flange, and in depth indi- <br />cated. <br />a. Clip Angle: 1-1/2 by 1-1/2 inch, 0.068-inch-thick, galvanized steel. <br />5. Hat -Shaped, Rigid Furring Channels: ASTM C 645, in depth indicated. <br />a. Minimum Base Metal Thickness: 0.0179 inch. <br />b. Tie Wire: ASTM A 641 /A 641M, Class 1 zinc coating, soft temper, 0.0625-inch- (1.59-mm-) diameter wire, or double <br />strand of 0.0475-inch-diameter wire. <br />6. Fasteners for Metal Framing: Of type, material, size, corrosion resistance, holding power, and other properties required to <br />fasten steel members to substrates. <br />2.3 PANEL PRODUCTS <br />A. Panel Size, General: Provide in maximum lengths and widths available that will minimize joints in each area and correspond with <br />support system indicated. <br />B. Gypsum Wallboard: ASTM C 36. <br />1. Regular Type: In thickness indicated and with long edges tapered. <br />2. Type X: In thickness indicated and with long edges tapered. <br />C. Flexible Gypsum Wallboard: ASTM C 36, manufactured to bend to fit tight radii and to be more flexible than standard regular -type <br />panels of the same thickness, 1/4 inch thick, and with long edges tapered. Apply in double layer at curved assemblies. <br />D. Sag -Resistant Gypsum Wallboard: ASTM C 36, manufactured to have more sag resistance than regular -type gypsum board, 1/2 <br />inch (12.7 mm) thick, and with long edges tapered. Apply on ceiling surfaces. <br />E. Exterior Gypsum Panels for Ceilings and Soffits: <br />1. Glass -Mat Gypsum Sheathing Board: ASTM C 1177/C 1177M, with core type and in thickness indicated. <br />a. Product: G-P Gypsum Corp; Dens -Glass Gold. <br />2.4 TRIM ACCESSORIES <br />A. Interior Trim: ASTM C 1047. <br />1. Cornerbead: Use at outside corners. <br />2. Bullnose Bead: Use at outside corners . <br />3. LC -Bead: Use at exposed panel edges. <br />B. Exterior Trim: ASTM C 1047, hot -dip galvanized steel sheet or rolled zinc. <br />1. Cornerbead: Use at outside corners. <br />2. LC -Bead: Use at exposed panel edges. <br />3. Expansion (Control) Joint: One-piece, rolled zinc with V-shaped slot and removable strip covering slot opening. <br />C. Aluminum Trim: Extruded accessories of profiles and dimensions indicated. <br />1. Products: <br />a. Fry Reglet Corp.; As indicated by designation on Drawings. <br />b. Gordon, Inc.. <br />C. MM Systems Corporation; As indicated by designation on Drawings. <br />d. Pittcon Industries; As indicated by designation on Drawings. <br />2. Aluminum: Alloy and temper with not less than the strength and durability properties of ASTM B 221, alloy 6063-T5. <br />3. Finish: Corrosion -resistant primer compatible with joint compound and finish materials specified. <br />2.5 JOINT TREATMENT MATERIALS <br />A. General: Comply with ASTM C 475. <br />B. Joint Tape: <br />1. Interior Gypsum Wallboard: Paper. <br />2. Exterior Gypsum Soffit Board: Paper. <br />3. Glass -Mat Gypsum Sheathing Board: 10-by-10 glass mesh. <br />C. Joint Compound for Interior Gypsum Wallboard: For each coat use formulation that is compatible with other compounds applied <br />on previous or for successive coats. <br />1. Prefilling: At open joints and damaged surface areas, use setting -type taping compound. <br />2. Embedding and First Coat: For embedding tape and first coat on joints, flanges of trim accessories, and fasteners, use <br />setting -type taping compound. <br />3. Fill Coat: For second coat, use setting -type, sandable topping compound. <br />4. Finish Coat: For third coat, use setting -type, sandable topping compound. <br />5. Skim Coat: For final coat of Level 5 finish, use setting -type, sandable topping compound. <br />D. Joint Compound for Exterior Applications: <br />1. Exterior Gypsum Soffit Board: Use setting -type taping and setting -type, sandable topping compounds. <br />2. Glass -Mat Gypsum Sheathing Board: As recommended by manufacturer. <br />E. Joint Compound for Tile Backing Panels: <br />1. Water -Resistant Gypsum Backing Board: Use setting -type taping and setting -type, sandable topping compounds. <br />2. Glass -Mat, Water -Resistant Backing Panel: As recommended by manufacturer. <br />3. Cementitious Backer Units: As recommended by manufacturer. <br />2.6 AUXILIARY MATERIALS <br />A. General: Provide auxiliary materials that comply with referenced installation standards and manufacturer's written recommenda- <br />tions. <br />1. Use screws complying with ASTM C 954 for fastening panels to steel members from 0.033 to 0.112 inch (0.84 to 2.84 mm) <br />thick. <br />2. For fastening cementitious backer units, use screws of type and size recommended by panel manufacturer. <br />PART 3 - EXECUTION <br />3.1 NON -LOAD -BEARING STEEL FRAMING INSTALLATION <br />A. General: Comply with ASTM C 754, and ASTM C 840 requirements that apply to framing installation. <br />B. Suspended Ceiling and Soffit Framing: <br />1. Suspend ceiling hangers plumb and free from contact with insulation or other objects within ceiling plenum that are not part <br />of supporting structural or ceiling suspension system. Splay hangers only where required to miss obstructions and offset <br />resulting horizontal forces by bracing, countersplaying, or other equally effective means. <br />2. Where width of ducts and other construction within ceiling plenum produces hanger spacings that interfere with the location <br />of hangers required to support standard suspension system members, install supplemental suspension members and hang- <br />ers in form of trapezes or equivalent devices. Size supplemental suspension members and hangers to support ceiling loads <br />within performance limits established by referenced standards. <br />3. Attach hangers to structural members. Do not support ceilings from or attach hangers to permanent metal forms, steel deck <br />tabs, steel roof decks, ducts, pipes, or conduit. <br />4. Screw furring to wood framing. <br />5. Wire -tie furring channels to supports, as required to comply with requirements for assemblies indicated. <br />6. Grid Suspension System: Attach perimeter wall track or angle where grid suspension system meets vertical surfaces. <br />Mechanically join main beam and cross -furring members to each other and butt -cut to fit into, wall track. <br />C. Partition and Soffit Framing: <br />1. Where studs are installed directly against exterior walls, install isolation strip between studs and wall. <br />2. Extend partition framing full height to structural supports or substrates above suspended ceilings, except where partitions <br />are indicated to terminate at suspended ceilings. Continue framing over frames for doors and openings and frame around <br />ducts penetrating partitions above ceiling to provide support for gypsum board. <br />3. Frame door openings to comply with GA-600 and with gypsum board manufacturer's applicable written recommendations, <br />unless otherwise indicated. Screw vertical studs at jambs to jamb anchor clips on door frames; install runner track section <br />(for cripple studs) at head and secure to jamb studs. <br />a. Install two studs at each jamb, unless otherwise indicated. <br />b. Extend jamb studs through suspended ceilings and attach to underside of floor or roof structure above. <br />4. Frame openings other than door openings the same as required for door openings, unless otherwise indicated. Install fram- <br />ing below sills of openings to match framing required above door heads. <br />3.2 PANEL PRODUCT INSTALLATION <br />A. Gypsum Board: Comply with ASTM C 840 and GA-216. <br />1. Space screws a maximum of 12 inches o.c. for vertical applications. <br />2. On ceilings, apply gypsum panels before wall/partition board application to the greatest extent possible and at right angles <br />to framing, unless otherwise indicated. <br />3. On partitions/walls, apply gypsum panels vertically (parallel to framing), unless otherwise indicated or required by fire - <br />resistance -rated assembly, and minimize end joints. <br />a. Stagger abutting end joints not less than one framing member in alternate courses of board. <br />b. At stairwells and other high walls, install panels horizontally, unless otherwise indicated or required by fire -resis- <br />tance -rated assembly. <br />4. Single -Layer Fastening Methods: Apply gypsum panels to supports with steel drill screws. <br />5. Laminating to Substrate: Comply with gypsum board manufacturer's written recommendations and temporarily brace or <br />fasten gypsum panels until fastening adhesive has set. <br />B. Exterior Ceilings and Soffits: Apply exterior gypsum panels perpendicular to supports, with end joints staggered and located over <br />supports. <br />1. Fasten with corrosion -resistant screws. <br />3.3 FINISHING <br />A. Installing Trim Accessories: For trim with back flanges intended for fasteners, attach to framing with same fasteners used for <br />panels. Otherwise, attach trim according to manufacturer's written instructions. <br />B. Finishing Gypsum Board Panels: Treat gypsum board joints, interior angles, edge trim, control joints, penetrations, fastener heads, <br />surface defects, and elsewhere as required to prepare gypsum board surfaces for decoration. <br />1. Prefill open joints and damaged surface areas. <br />2. Apply joint tape over gypsum board joints, except those with trim having flanges not intended for tape. <br />3. Glass -Mat Gypsum Sheathing Board: Finish according to manufacturer's written instructions for use as exposed soffit <br />board. <br />4. Glass -Mat, Water -Resistant Backing Panels: Finish according to manufacturer's written instructions. <br />C. Gypsum Board Finish Levels: Finish panels to levels indicated below, according to ASTM C 840, for locations indicated: <br />1. Level 4: Embed tape and apply separate first, fill, and finish coats of joint compound to tape, fasteners, and trim flanges at <br />panel surfaces that will be exposed to view, unless otherwise indicated. <br />END OF SECTION 09260 <br />PART 1 - GENERAL <br />1.1 SUMMARY <br />A. This Section includes acoustical tiles and concealed suspension systems for ceilings. <br />1.2 SUBMITTALS <br />A. Product Data: For each product indicated. <br />B. Samples: For each acoustical tile, for each concealed suspension system member and for each color and texture required. <br />C. Product test reports. <br />1.3 QUALITY ASSURANCE <br />A. Acoustical Testing Agency Qualifications: An independent testing laboratory or an NVLAP-accredited laboratory. <br />B. Fire -Test -Response Characteristics: <br />1. Fire -Resistance Ratings: Where indicated, provide acoustical tile ceilings identical to those of assemblies tested for fire <br />resistance per ASTM E 119 by UL or another testing and inspecting agency acceptable to authorities having jurisdiction. <br />Ratings are indicated by design designations from UUs "Fire Resistance Directory" or from the listings of another testing <br />and inspecting agency. <br />a. Identify materials with appropriate markings of applicable testing and inspecting agency. <br />2. Surface -Burning Characteristics: Acoustical tiles complying with ASTM E 1264 for Class A materials, when tested per <br />ASTM E 84. <br />a. Smoke -Developed Index: 450 or less. <br />C. Seismic Standard: Comply with the following: <br />1. ASTM E 580. <br />2. CISCA's "Recommendations for Direct -Hung Acoustical Tile and Lay -in Panel Ceilings --Seismic Zones 0-2." <br />3. Mockups: Build mockups to verify selections made under sample Submittals and to <br />PART 2 - PRODUCTS <br />2.1 MANUFACTURERS <br />A. In other Part 2 articles where titles below introduce lists, the following requirements apply for product selection: <br />1. Available Products: Subject to compliance with requirements, products that may be incorporated into the Work include, but <br />are not limited to, the products specified. <br />2.2 GENERAL <br />A. Acoustical Tile Standard: Comply with ASTM E 1264. <br />B. Metal Suspension System Standard: Comply with ASTM C 635. <br />C. Attachment Devices: Size for five times the design load indicated in ASTM C 635, Table 1, "Direct Hung," unless otherwise indi- <br />cated. <br />1. Anchors in Concrete: Expansion anchors fabricated from corrosion -resistant materials, with holes or loops for attaching <br />hangers of type indicated and with capability to sustain, without failure, a load equal to five times that imposed by ceiling <br />construction, as determined by testing per ASTM E 488 or ASTM E 1512 as applicable, conducted by a qualified testing and <br />inspecting agency. <br />2. Power -Actuated Fasteners in Concrete: Fastener system of type suitable for application indicated, fabricated from cor- <br />rosion -resistant materials, with clips or other accessory devices for attaching hangers of type indicated, and with capabil- <br />ity to sustain, without failure, a load equal to 10 times that imposed by ceiling construction, as determined by testing per <br />ASTM E 1190, conducted by a qualified testing and inspecting agency. <br />D. Wire Hangers, Braces, and Ties: Zinc -coated carbon -steel wire; ASTM A 641/A 641 M, Class 1 zinc coating, soft temper. <br />1. Size: Select wire diameter so its stress at three times hanger design load (ASTM C 635, Table 1, "Direct Hung") will be less <br />than yield stress of wire, but provide not less than 0.106-inch- diameter wire. <br />E. Seismic struts and seismic clips. <br />F. Metal Edge Moldings and Trim: Type and profile indicated or, if not indicated, manufacturer's standard moldings for edges and <br />penetrations that fit acoustical tile edge details and suspension systems indicated; formed from sheet metal of same material and <br />finish as that used for exposed flanges of suspension system runners. <br />2.3 ACOUSTICAL TILES <br />A. General: Acoustical tiles shall be 24" x 48" x 5/8" matte finish mineral fiber ceiling boards and shall conform to Federal Specifica- <br />tion SS-S-118a, Class 25. Light reflectance shall be no less than 75% and have NRC minimum range of .50 - .60. <br />B. Products: <br />1. Armstrong "Cortega". <br />2. Celotex `Baroque" <br />3. U.S.G. "Omni Fissured" <br />2.4 METAL SUSPENSION SYSTEM <br />A. General: The ceiling suspension system shall be an exposed grid system with exposed flanges having a factory applied white <br />enamel finish with roll formed capped edges. <br />1. Main Runner: DX-24 <br />2. Cross Tees: DX-424 <br />3. Wall Angle: M6S <br />B. Products: <br />1. Donn Products, Inc., Westlake, OH. <br />2. Acoustical Tile Supplier Standard Grid System. <br />C. Ceiling Suspension System: Direct hung; ASTM C 635, intermediate -duty structural classification. <br />PART 3 - EXECUTION <br />3.1 INSTALLATION <br />A. General: Install acoustical tile ceilings to comply with ASTM C 636 and seismic requirements indicated, per manufacturer's writ- <br />ten instructions and CISCA's "Ceiling Systems Handbook." <br />B. Measure each ceiling area and establish layout of acoustical tiles to balance border widths at opposite edges of each ceiling. Avoid <br />using less -than -half -width tiles at borders. <br />C. Suspend ceiling hangers from building's structural members, plumb and free from contact with insulation or other objects within <br />ceiling plenum. Splay hangers only where required to miss obstructions; offset resulting horizontal forces by bracing, counter - <br />splaying, or other equally effective means. Where width of ducts and other construction within ceiling plenum produces hanger <br />spacings that interfere with location of hangers, use trapezes or equivalent devices. <br />1. Do not support ceilings directly from permanent metal forms or floor deck; anchor into concrete slabs. <br />2. Do not attach hangers to steel deck tabs or to steel roof deck. <br />D. Install edge moldings and trim at perimeter of acoustical tile ceiling area and where necessary to conceal edges of acoustical units. <br />Screw attach moldings to substrate with concealed fasteners at intervals not more than 16 inches o.c. and not more than 3 inches <br />from ends, leveling with ceiling suspension system to a tolerance of 1/8 inch in 12 feet. Miter corners accurately and connect <br />securely. <br />E. Install suspension system runners so they are square and securely interlocked with one another. Remove and replace dented, bent, <br />or kinked members. <br />F. Install acoustical tiles in coordination with suspension system and exposed moldings and trim. Place splines or suspension system <br />flanges into kerfed edges so tile -to -tile joints are closed by double lap of material. Fit adjoining tile to form flush, tight joints. <br />Scribe and cut tile for accurate fit at borders and around penetrations through tile. Hold tile field in compression by inserting leaf - <br />type, spring -steel spacers between tile and moldings, spaced 12 inches o.c. <br />END OF SECTION 09512 <br />SECTION 0%53 - RESILIENT WALL BASE AND ACCESSORIES <br />PART 1 - GENERAL <br />1.1 SUMMARY <br />A. This Section includes the following: <br />1. Wall base. <br />1.2 SUBMITTALS <br />A. Product Data: None. <br />B. Samples: For each of r <br />p type product indicated, in manufacturer'standard-size Samples but not less than 12 inches (300 min) long, <br />of each resilient product color, texture, and pattern required. Submit directly to the owner for approval. <br />1.3 PROJECT CONDITIONS <br />A. Maintain temperatures within range recommended by manufacturer, but not less than 70 deg F (21 deg C) or more than 95 deg F <br />(35 deg C), in spaces to receive floor tile during the following time periods: <br />1. 48 hours before installation. <br />2. During installation. <br />3. 48 hours after installation. <br />B. After postinstallation period, maintain temperatures within range recommended by manufacturer, but not less than 55 deg F (13 <br />deg C) or more than 95 deg F (35 deg C). <br />C. Install resilient products after other finishing operations, including painting, have been completed. <br />1.4 EXTRA MATERIALS <br />A. Furnish extra materials described below that match products installed and that are packaged with protective covering for storage <br />and identified with labels describing contents. <br />1. Furnish not less than 10 linear feet (3 linear m) for every 500 linear feet (150 linear m) or fraction thereof, of each type, <br />color, pattern, and size of resilient product installed. <br />PART 2 - PRODUCTS <br />2.1 MANUFACTURERS <br />A. Available Products: Subject to compliance with requirements, products that may be incorporated into the Work include, but are <br />not limited to, products listed in other Part 2 articles. <br />B. Products: Subject to compliance with requirements, provide one of the products listed in other Part 2 articles. <br />2.2 COLORS AND PATTERNS <br />A. Colors and Patterns: As selected from manufacturer's full range. <br />2.3 RESILIENT WALL BASE <br />A. Wall Base: ASTM F 1861. <br />1. AFCO-USA, American Floor Products Company, Inc. <br />2. Armstrong World Industries, Inc. <br />3. Johnsonite. <br />4. Roppe Corporation. <br />B. Type (Material Requirement): TV (vinyl), TS (rubber, vulcanized thermoset) or TP (rubber, thermoplastic). <br />C. Group (Manufacturing Method): I (solid). <br />D. Style: Cove (with top -set toe). <br />E. Minimum Thickness: 0.125 inch (3.2 mm). <br />F. Height: 6 inches (102 mm). <br />G. Lengths: Cut lengths 48 inches (1219 mm) long or coils in manufacturer's standard length. <br />H. Outside Corners: Job formed or premolded. <br />I. Inside Corners: Job formed or premolded. <br />J. Surface: Smooth. <br />2.4 INSTALLATION MATERIALS <br />A. Trowelable Leveling and Patching Compounds: Latex -modified, portland cement based or blended hydraulic cement based for- <br />mulation provided or approved by resilient product manufacturers for applications indicated. <br />B. Adhesives: Water-resistant type recommended by manufacturer to suit resilient products and substrate conditions indicated. <br />PART 3 - EXECUTION <br />3.1 PREPARATION <br />A. Prepare substrates according to manufacturer's written recommendations to ensure adhesion of resilient products. <br />B. Concrete Substrates for Stair Accessories: Prepare according to ASTM F 710. <br />1. Verify that substrates are dry and free of curing compounds, sealers, and hardeners. <br />2. Alkalinity and Adhesion Testing: Perform tests recommended by manufacturer. Proceed with installation only after sub- <br />strates pass testing. <br />3. Moisture Testing: <br />a. Perform anhydrous calcium chloride test, ASTM F 1869. Proceed with installation only after substrates have maxi- <br />mum moisture -vapor -emission rate of 3 lb of water/1000 sq. ft. (1.36 kg of water/92.9 sq. m) in 24 hours. <br />b. Perform tests recommended by manufacturer. Proceed with installation only after substrates pass testing. <br />C. Remove substrate coatings and other substances that are incompatible with adhesives and that contain soap, wax, oil, or silicone, <br />using mechanical methods recommended by manufacturer. Do not use solvents. <br />D. Use trowelable leveling and patching compound to fill cracks, holes, and depressions in substrates. <br />E. Move resilient products and installation materials into spaces where they will be installed at least 48 hours in advance of installa- <br />tion. <br />1. Do not install resilient products until they are the same temperature as the space where they are to be installed. <br />F. Sweep and vacuum clean substrates to be covered by resilient products immediately before installation. After cleaning, examine <br />substrates for moisture, alkaline salts, carbonation, and dust. Proceed with installation only after unsatisfactory conditions have <br />been corrected. <br />3.2 RESILIENT WALL BASE INSTALLATION <br />A. Apply wall base to walls, columns, pilasters, casework and cabinets in toe spaces, and other permanent fixtures in rooms and areas <br />where base is required. <br />B. Install wall base in lengths as long as practicable without gaps at seams and with tops of adjacent pieces aligned. <br />C. Tightly adhere wall base to substrate throughout length of each piece, with base in continuous contact with horizontal and vertical <br />substrates. <br />D. Do not stretch wall base during installation. <br />E. On masonry surfaces or other similar irregular substrates, fill voids along top edge of wall base with manufacturer's recommended <br />adhesive filler material. <br />F. Premolded Corners: Install premolded corners before installing straight pieces. <br />G. Job -Formed Corners: <br />1. Outside Corners: Use straight pieces of maximum lengths possible. Form without producing discoloration (whitening) at <br />bends. Shave back of base at points where bends occur and remove strips perpendicular to length of base that are only deep <br />enough to produce a snug fit without removing more than half the wall base thickness. <br />2. Inside Corners: Use straight pieces of maximum lengths possible. Form by cutting an inverted V-shaped notch in toe of <br />wall base at the point where corner is formed. Shave back of base where necessary to produce a snug fit to substrate. <br />3.3 CLEANING AND PROTECTION <br />A. Perform the following operations immediately after completing resilient product installation: <br />1. Remove adhesive and other blemishes from exposed surfaces. <br />2. Sweep and vacuum surfaces thoroughly. <br />3. Damp -mop surfaces to remove marks and soil. <br />a. Do not wash surfaces until after time period recommended by manufacturer. <br />B. Protect resilient products from mars, marks, indentations, and other damage from construction operations and placement of equip- <br />ment and fixtures during remainder of construction period. Use protection methods recommended in writing by manufacturer. <br />END OF SECTION 0%53 <br />SECTION 09900 - PAINT AND WALL FINISHES <br />PART 1 - GENERAL <br />1.1 SUMMARY <br />A. This Section includes surface preparation and field painting of exposed items and surfaces. <br />1.2 SUBMITTALS <br />A. Product Data: For each product indicated. <br />B. Samples: For each type of finish -coat material indicated. To be submitted directly to the owner for approval. <br />1.3 QUALITY ASSURANCE <br />A. Benchmark Samples (Mockups): Provide a full -coat benchmark finish sample for each type of coating and substrate required. <br />Comply with procedures specified in PDCA P5. <br />1. Wall Surfaces: Provide samples on at least 100 sq. ft.. <br />2. Small Areas and Items: Architect will designate items or areas required. <br />3. Final approval of colors will be from benchmark samples. <br />V� <br />U <br />C> `c <br />4.5 <br />o <br />U Q <br />C:8 `3 <br />603 <br />� b <br />U w <br />U <br />O <br />O <br />i <br />0 <br />CU <br />o C) W <br />z <br />! "^i^11 g �° <br />W V M <br />a <br />o E a� <br />z �¢ <br />a <br />W M <br />U <br />Cn <br />i <br />O <br />E <br />E <br />U <br />i <br />C <br />Cv <br />N <br />♦_0 <br />CU <br />Ln <br />m <br />(3) <br />U <br />CU <br />Imo <br />o (n o <br />Q Q J <br />2 4-0 o " <br />vC '� <br />LL CZ coJ <br />? J = <br /><> <br />LU <br />Q± _ <br />0 <br />a <br />� F Z N <br />a <br />N E <br />O �+ <br />N <br />M <br />o <br />0" <br />0 <br />0 <br />N <br />IV <br />oX <br />0 <br />Z-T <br />zco <br />O N <br />Q I.- <br />N � <br />�A <br />2 <br />>�3 <br />J <br />t <br />� <br />cm M <br />a* <br />z a <br />W Cr <br />vl <br />� <br />UJ <br />w <br />cn <br />cc <br />W <br />a <br />LO <br />0 <br />W <br />o <br />to <br />Co <br />a <br />N <br />. <br />W <br />N <br />n <br />-W <br />to <br />CO <br />aD <br />co <br />Q <br />C) <br />W <br />m <br />!R <br />m <br />U rn� <br />of <br />W <br />W c+� <br />rn <br />¢ <br />Y <br />W <br />N <br />cn <br />UJ <br />a <br />co <br />o <br />c> <br />B5 TENANT BUILD OUT <br />SECTION 09512 - ACOUSTICAL TILE CEILINGS <br />