7952-7954 Gall Blvd
Zephyrhills
>
Building Department
>
Building Plans
>
7952-7954 Gall Blvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 12:13:47 PM
Creation date
2/19/2025 11:53:39 AM
Metadata
Fields
Template:
Building Plans
Street #
7952-7954
Location
Gall Blvd
Contractor
Hawkeye Construction
Building Plans - Permit #
11530
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MECHANICAL NOTES <br />1. <br />PROVIDE COMPLETE HVAC SYSTEMS TO MEET ALL CODES. HVAC <br />- <br />SUBCONTRACTOR IS RESPONSIBLE FOR SUBMITTING A TOTALLY INCLUSIVE <br />BID WHICH COVERS ALL WORK NECESSARY TO MEET ALL CODES WHETHER <br />SHOWN ON DRAWING OR NOT. <br />2. <br />ALL MECHANICAL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH <br />MANUFACTURER'S RECOMMENDATIONS AND LOCAL CODES. <br />ROOF TOP AIR CONDITIONING UNIT <br />3. <br />ALL WORK TO CONFORM TO INDUSTRY STANDARDS AND ALL FEDERAL, <br />STATE AND LOCAL CODES AND REGULATIONS. <br />ACOUSTICAL LINER <br />4. <br />PROVIDE OWNER WITH ONE (1) YEAR SERVICE AND ONE (1) YEAR <br />UNDER UNIT <br />�- <br />GUARANTEE ON ALL EQUIPMENT AND A FIVE (5) YEAR GUARANTEE <br />WATERTIGHT <br />ON THE AIR CONDITION COMPRESSORS. <br />FLASHING <br />I I I I <br />5. <br />COORDINATE WITH ALL OTHER TRADES BEFORE STARTING INSTALLATION. <br />I I I <br />MAKE NECESSARY VARIATIONS AT THAT TIME TO FIT INTO SPACE <br />I I I <br />CONDITIONS AT NO EXTRA COST TO THE OWNER. <br />6. <br />HVAC SUBCONTRACTOR TO COORDINATE WITH ELECTRICAL SUBCONTRAC- <br />TOR PRIOR TO STARTING ANY WORK OR ORDERING ANY MATERIALS TO <br />INSURE COMPLETE COMPATIBILITY WITH ELECTRICAL SYSTEMS AND <br />COMPLIANCE WITH ALL CODES. MECHANICAL SUBCONTRACTOR SHOULD <br />VERIFY VOLTAGES, WIRE SIZES AND BREAKER SIZES AS PART OF THE <br />S.A. -.-ti-- I FLEXIBLE <br />COORDINATION. <br />---- -� CONNECTION -- <br />7. <br />OBTAINING ALL REQUIRED PERMITS AND PAYING ALL ASSOCIATED FEES ARE THE <br />RESPONSIBILITY OF THE CONTRACTOR. <br />SUPPLY 8 RETURN <br />DUCTWORK BY TENANT <br />8. ALL CONTROL WIRING SHALL BE RUN INSIDE WALLS OR ABOVE CEILINGS. IN <br />UNFINISHED AREAS, ROUTE CONTROL WIRING INSIDE CONDUIT IN JOIST SPACE. <br />9. LOCATION OF ALL PENETRATIONS SHALL BE COORDINATED WITH <br />ARCHITECTURAL AND STRUCTURAL DRAWINGS. <br />10. ALL FANS 1/8 H.P. AND ABOVE SHALL HAVE FUSED DISCONNECT SWITCHES <br />MOUNTED AT THE FAN. IF APPROVED BY LOCAL AUTHORITIES, NON -FUSED <br />DISCONNECT SWITCHES MAY BE USED. DISCONNECTS PROVIDED BY ELECTRICAL <br />CONTRACTOR. <br />11. FOR ALL UNITS OVER 2000 CFM PROVIDE ONE SMOKE DETECTOR IN THE RETURN <br />AIR DUCT. <br />12. GREASE AND OIL ALL EQUIPMENT AS REQUIRED AND REPLACE ALL FILTERS <br />BEFORE TURNING JOB OVER TO OWNER. <br />13. DUCTS AND DIFFUSERS ARE SHOWN TO CLEAR LIGHT FIXTURES; HOWEVER, <br />SOME SHIFTING MAY BE REQUIRED - VERIFY IN FIELD BEFORE INSTALLATION. <br />14. THE MECHANICAL DRAWINGS ARE DIAGRAMATIC AND SHOW THE RELATIONSHIP <br />BETWEEN EQUIPMENT AND CONNECTIONS. DO NOT SCALE THE DRAWINGS <br />FOR EXACT SIZE OR LOCATIONS. BUILDING DIMENSIONS SHALL BE TAKEN <br />FROM ARCH. PLANS AND EQUIPMENT DIMENSIONS SHALL BE TAKEN FROM <br />CERTIFIED EQUIPMENT DATA. <br />15. A CERTIFIED TEST AND BALANCE REPORT BY AN AGENCY OR COMPANY <br />OTHER THAN THE INSTALLER IS TO BE PROVIDED WITH A FOLLOW-UP <br />REPORT ONCE ADJUSTMENTS ARE MADE. <br />16. PLANS AND SKETCHES ARE SUBMITTED TO LIMIT, EXPLAIN AND DEFINE <br />CONDITIONS, SPECIFIED REQUIREMENTS, PIPE SIZES AND MANNER OF <br />ERECTING WORK. STRUCTURAL OR OTHER CONDITIONS MAY REQUIRE CERTAIN <br />MODIFICATIONS FROM THE DESIGN SHOWN; REQUIREMENTS NECESSARY FOR <br />SATISFACTORY OPERATION SHALL REMAIN UNCHANGED. IT MAY BE <br />NECESSARY TO SHIFT PIPES AND THESE CHANGES SHALL BE MADE AS <br />REQUIRED. ALL SUCH CHANGES OR DESIGN MODIFICATIONS SHALL BE REFERRED <br />TO THE ARCHITECT FOR APPROVAL BEFORE PROCEEDING. EXTRA CHARGES SHALL <br />NOT BE ALLOWED FOR THESE CHANGES. THE SUBCONTRACTOR SHALL REALIZE <br />THAT THE DRAWINGS COULD NOT DELVE INTO EVERY STEP, SEQUENCE OR OPERATION <br />NECESSARY FOR THE COMPLETION OF THE PROJECT WITHOUT DRAWING ON THE <br />SUBCONTRACTOR'S EXPERIENCE OR INGENUITY. HOWEVER, ONLY TYPICAL LAYOUT <br />IS SHOWN ON THE PLANS. IN CASES WHERE THE SUBCONTRACTOR IS NOT CERTAIN <br />ABOUT THE METHOD OF INSTALLATION OF HIS HIS WORK, HE SHALL CONSULT WITH <br />THE ARCHITECT. LACK OF DETAILS SHALL NOT BE AN EXCUSE FOR IMPROPER <br />INTALLATION. IN GENERAL THE DRAWINGS ARE DIAGRAMMATIC AND THE SUBCONTRACTOR <br />SHALL INSTALL HIS WORK IN SUCH MANNER SO THAT INTERFERENCES BETWEEN <br />THE VARIOUS TRADES IS AVOIDED, IN CASES WHERE INTERFERENCES DO OCCUR, <br />THE ARCHITECT IS TO STATE WHICH EQUIPMENT, PIPING, ETC. IS TO BE RELOCATED <br />REGARDLESS OF WICH ITEM WAS INSTALLED FIRST. <br />17. DUCT SIZES ARE SHOWN AS CLEAR INSIDE DIMENSIONS. PROVIDE FLEXIBLE <br />CONNECTIONS WHERE DUCTS CONNECT TO UNIT. <br />18. SPIN -IN TAKE -OFF TO BE MADE WITH GENFLEX MODEL SM-1 DEL OR <br />EQUIVALENT. <br />19. NTPEDAMPERS NSHALL BE OUFFI- <br />CEGAUGEiO RVENTT UCING OWHERE <br />VIBRAT NdAND SHALL BE <br />OPERATED BY A QUADRANT DAMPER ADJUSTER WITH LOCKING FEATURE <br />WHICH WILL HOLD DAMPER SECURELYIN POSITION AT THE DESIRED SETTING. <br />20. REGISTERS, DIFFUSERS AND GRILLES SHALL BE FURNISHED AND INSTALLED <br />IN SIZES AND AT LOCATIONS AS SHOWN ON DRAWINGS. ALL OUTLETS SHALL <br />BE INSTALLED PLUMB AND LEVEL AND PARALLEL TO THE BUILDING WALLS <br />OR FLOORS. CEILING DIFFUSERS AND GRILLES SHALL BE AS SCHEDULED, OR <br />APPROVED EQUAL. <br />21. PROVIDE OPERATING MAINTENANCE MANUAL FOR FURNISHED EQUIPMENT. <br />22. MOUNT ALL THERMOSTATS 48" A.F.F. UNLESS OTHERWISE NOTED. ANY <br />THERMOSTAT LOCATED ON AN EXTERIOR WALL SHALL BE MOUNTED ON <br />AN INSULATING BASE. ALL CONTROL WIRING SHALL BE RUN INSIDE WALLS <br />OR ABOVE CEILINGS. <br />23. ALL SUPPLY AND RETURN DUCTWORK FROM ROOFTOP UNITS INSTALLED ABOVE CEILINGS <br />TO BE GALVANIZED LOW PRESSURE DUCTWORK WITH EXTERNAL DUCT WRAP INSULATION. <br />ALL DUCTWORK TO BE CONSTRUCTED PER CURRENT SMACNA LOW PRESSURE <br />DUCT REQUIREMENTS. ALL JOINTS SHALL BE SEALED WITH DUCT SEALER. <br />PROVIDE 2" FIBERGLASS DUCT WRAP WITH U.L. LISTED FOIL VAPOR BARRIER <br />AND A MINIMUM R VALUE OF 6.0. ALL EXPOSED SPIRAL DUCT TO BE LINDAB DOUBLE WALL <br />SPIROSAFE GASKETED DUCTWORK. <br />24. PROVIDE FIRE DAMPERS AT ALL FIRE RATED PENETRATIONS. <br />25. ALL DUCTWORK SHALL BE SUPPORTED BY THE BUILDING STRUCTURE AND SHALL NOT <br />REST ON CEILING TILES OR CEILING STRUCTURE. ALL DUCTWORK SHALL BE SUPPORTED <br />AND ATTACHED TO STRUCTURE PER CURRENT SMACNA STANDARDS. <br />26. FLEXIBLE DUCTWORK SHALL BE HART & COOLEY TYPE Rf214 OR EQUAL WITH A MAXIMUM LENGTH <br />OF 6-0". FLEXIBLE DUCTWORK SHALL BE INSTALLED AS STRAIGHT AS POSSIBLE AND SHALL <br />BE ROUTED AND SUPPORTED WITHOUT CAUSING ANY AIR FLOW RESTRICTIONS. <br />27. PROVIDE A MINIMUM OF 10'-0" SEPERATION BETWEEN ALL FRESH AIR INTAKES AND EXHAUST. <br />28. THE EXHAUST OUTLETS OF THE COMMERCIAL HOODS SHALL TERMINATE OUTSIDE THE <br />BUILDING AND SHALL BE LOCATED TEN FEET AWAY FROM ANY ADJACENT BUILDING, PARKING <br />AREA, ADJACENT PROPERTY LINE, WINDOW, DOOR OR AIR INTAKE OPENING AND SHALL BE <br />A MINIMUM OF TEN FEET ABOVE ADJOINING GRADE LEVEL AND SHALL TERMINATE 40 INCHES <br />ABOVE ROOF SURFACE WHEN THERE IS A ROOF TERMINATION. <br />29. ALL KITCHEN HOODS AND FANS SHALL MEET OR EXCEED REQUIREMENTS OF NFPA 96 <br />FOR VENTILATION CONTROL AND FIRE PROTECTION OF COMMERCIAL COOKING OPERATIONS. <br />30. THE GREASE HOOD VENT TERMINATION MUST MEET SECTION 506.3.12 OF THE IMC. <br />31. CLEARANCE FOR TYPE I HOOD SYSTEM SHALL BE INSTALLED WITH A CLEARANCE TO <br />COMBUSTIBLES OF NOT LESS THAN 18 INCHES. <br />32. ALL FRAMING BEHIND THE GREASE HOODS MUST BE NON-COMBUSTIBLE PER SECTION <br />507.9 OF THE 2006 IMC. <br />33. EXTERNAL HOOD JOINTS, SEAMS AND PENETRATIONS FOR TYPE I HOODS SHALL BE MADE <br />WITH A CONTINUOUS EXTERNAL LIQUID -TIGHT WELD OR BRAZE TO THE LOWEST OUTERMOST <br />PERIMETER OF THE HOOD. INTERNAL HOOD JOINTS, SEAMS, PENETRATIONS, FILTER SUPPORT <br />FRAMES AND OTHER APPENDAGES ATTACHED INSIDE THE HOOD SHALL NOT BE REQUIRED TO BE <br />WELDED OR BRAZED BUT SHALL BE GREASE TIGHT. <br />34. DUCTWORK FROM KITCHEN HOODS TO EXHAUST FANS SHALL BE CONSTRUCTED OF MINIMUM 18 <br />GUAGE STAINLESS STEEL OR 16 GAUGE BLACK IRON ALL WELDED COSNTRUCTION WITH WELDED <br />JOINTS. PROVIDE HINGED ACCESS DOORS AS REQUIRED BY CODE. <br />35. THE ANSUL PULL STATION FOR THE HOOD IS TO BE RECESSED WITH THE CONDUIT ENCLOSED <br />IN THE WALL. COORDINATE WITH CAPTIVE AIRE DRAWINGS. <br />CONDENSATE DRAIN LINE <br />C--I <br />- FACTORY ROOF CURB <br />T--]�Rh <br />� 0 <br />I ROOFTOP UNIT DETAIL <br />M-2 P SCALE NONE <br />I <br />PRESSURE TREATED <br />WOOD NAILER----'12" <br />2" ACOUSTICAL <br />FIBERGLASS <br />UNDER UNIT <br />RESILIENT GASKET <br />90# MINIMUM SURFACE <br />BASE FLASHING <br />ROOF SYSTEM <br />(SEE ARCH. DRAWINGS) <br />METAL ROOF DECKING <br />PREFAB CURB & CANT <br />WITH RIGID INSULATION <br />ROOFTOP UNIT CURB DETAIL <br />SCALE NONE <br />TURNING VANES <br />PER LATEST SMACNA <br />STANDARDS --�, <br />DOUBLE THICKNESS <br />DIVERTING VANE - <br />SPLITTER ROD <br />SPLITTER DAMPER WITH <br />LOCKING QUADRANT <br />3 \ SPLITTER DAMPER. DETAIL <br />M-2 / SCALE NONE <br />VANES TO BE PRE -ASSEMBLED <br />ON RUNNER PLATE. <br />GALVANIZED VANES <br />DOUBLE THICKNESS TURNING VANES <br />SCALE NONE <br />ROOFTOP UNIT SCHEDULE <br />MARK <br />CFM <br />O.A. <br />CFM <br />ESP <br />W.G. <br />H.P. <br />COOLING <br />HEATING BTU/HR <br />BASIS OF DESIGN <br />CARRIER OR EQUAL <br />SEER/EER <br />NOTES <br />EAT°FDb <br />EAT°Fwb <br />CAP.MBH <br />INPUT <br />OUTPUT <br />RTU-A <br />3,000 <br />765 <br />0.8" <br />3.0 <br />80"F <br />670F <br />90.1 <br />125,000 <br />103,000 <br />48TCDD008A2 <br />11.0/- <br />0 <br />i) PROVIDE FULL PERIMETER FACTORY ROOF CURB. COORDINATE VOLTAGE REQUIREMENTS WITH ELECTRICAL CONTRACTOR PRIOR TO ORDERING. <br />FAN SCHEDULE <br />MARK <br />CFM <br />E.S.P. <br />WG <br />DRIVE <br />H.P. <br />TYPE <br />BASIS OF <br />DESIGN <br />LOCATION/SERVICE <br />NOTES <br />EF-A <br />150 <br />1/4" <br />DIRECT <br />1/30 <br />CENTRIFUGAL <br />GREENHECK G-065-D <br />MOP SINK <br />O <br />EF-B <br />225 <br />3/8" <br />DIRECT <br />1/25 <br />CENTRIFUGAL <br />GREENHECK G-075-D <br />RESTROOMS <br />Q2 <br />Q1 INTERLOCK WITH PREP ROOM LIGHTS. <br />Q INTERLOCK WITH TOILETROOM LIGHTS. <br />AIR DISTRIBUTION SCHEDULE <br />MARK <br />TYPE <br />SIZE IN <br />INCHES <br />FINISH <br />O.B.D. <br />BASIS OF <br />DESIGN <br />NOTES <br />NECK <br />FACE <br />O <br />SUPPLY <br />61-0 <br />12"xl2" <br />02 <br />NO <br />TITUS PAS <br />Q <br />© <br />SUPPLY <br />8"0 <br />16"x16" <br />Q2 <br />NO <br />TITUS PAS <br />1Q <br />© <br />SUPPLY <br />800 <br />24"x24" <br />0 <br />NO <br />TITUS PAS <br />Q <br />OD <br />SUPPLY <br />12"0 <br />24"x24" <br />Q <br />NO <br />TITUS PAS <br />Q <br />OE <br />SUPPLY <br />16"0 <br />24"x24" <br />0 <br />NO <br />TITUS PAS <br />10 <br />0 <br />SUPPLY <br />- <br />21"x6" <br />Q <br />NO <br />LINDAB RGS-3 <br />© <br />SUPPLY <br />- <br />25"x9" <br />Q2 <br />NO <br />LINDAB RGS-3 <br />O <br />RETURN <br />18"0 <br />24"x24" <br />U2 <br />NO <br />TITUS PAR <br />JO <br />EXHAUST <br />10"0/10"x10" <br />12"x12" <br />02 <br />NO <br />TITUS 350FL <br />0 FLEXDUCT = ROUND NECK SIZE LISTED. <br />2Q SEE ARCHITECTUAL PLANS FOR FINISH INFORMATION. <br />0 ADJUST DIFFUSER FOR 2 WAY DISTRIBUTION PATTERN. <br />® ADJUST DIFFUSER FOR 3 WAY DISTRIBUTION PATTERN TO BLOW AIR AWAY FROM THE HOOD. <br />SUPPLY <br />DUCT - <br />TYPICAL SPIN -IN <br />FITTING W/DAMPER <br />TYPICAL FLEXIBLE <br />DUCTWORK; (MAXIMUM <br />ROUND DUCTWORK <br />TYPICAL CEILI <br />DIFFUSER <br />FLEXIBLE DUCT TAKE -OFF DETAIL <br />SCALE: NONE <br />Q'e�4 CIA I <br />211 e(a <br />TRACY M. WOODALL, P.E. <br />181 Sedgefield Overlook <br />Dallas, Georgia 30157 <br />T: (678) 642-7282 Florida PE <br />F: (770) 406-2381 #56620 <br />ERIC J. SAFFRAN <br />ARCHITECT <br />Preston Ridge Commons <br />3155 North Point Parkway <br />Building E - Suite 200 <br />Alpharetta, Georgia 30005 <br />Tel 770 619 5916 <br />Fax 770 619 5919 <br />e `N���114ttltl���i <br />sip %ft <br />lot <br />P �.• �'� 4;� <br />LU <br />W <br />Z <br />i W - <br />U Ln <br />Z Q Q <br />L a <br />0 J GC <br />N0_j <br />Z -I <br />O Q =J <br />� oC <br />Lz LLI <br />0cr'.= <br />a <br />W <br />= N <br />a <br />W <br />N <br />ISIONS <br />E <br />REVISION <br />F <br />INDEMNIFICATION CLAUSE <br />THE OWNER SHALL RELEASE, HOLD <br />HARMLESS, AND INDEMNIFY THE <br />ARCHITECT WITH RESPECT TO: ANY <br />CHANGES MADE TO THE CONSTRUCTIO <br />DOCUMENTS BY ANYONE OTHER THA <br />THE ARCHITECT, OR CHANGES IN ANY <br />ASPECT OF THE WORK OR FAILURE BY <br />THE CONTRACTOR TO BUILD IN <br />ACCORDANCE WITH THESE <br />CONSTRUCTION DOCUMENTS <br />OPYRIGHT 2010 <br />J. SAFFRAN, ARCHITECT <br />WING IS THE PROPERTY OF <br />FRAN, ARCHITECT <br />FSAFFRAN. <br />OT TO BE REPRODUCED OR <br />IN WHOLE OR IN PART. <br />RIZED USE OF ANY KIND, <br />G USE ON ANY OTHER <br />IS PROHIBITED. ITISTOBE <br />RETRNED UPON REQUEST. <br />ESHEE7TITLESCHEDULES, <br />ILS - HVAC <br />PROJECT <br />SHEET NO. <br />NO <br />1030 <br />DRAWN <br />BY <br />TMW <br />Ms2 <br />DATE <br />11-23-10 <br />2OF6 <br />r' r <br />It. <br />