LM
<br />Q FLOOR PLAN NOTES:
<br />GENERAL:
<br />- CONCRETE 5LA5 TO BE PATCHED SMOOTHED AND MADE READY FOR NEW FINISHES.
<br />- PATCH (TAPE & 5FACKLE), SAND, AND REPAIR EXTERIOR & DEMISING WALLS. FREFARE FOR NEW FINISH, WHERE APFICASLE
<br />- REFER TO PARTITION LEGEND FOR WALL TYPES, SHEET AM
<br />- ALL NEW AND EXISTING NON -FIRE RATED PARTITIONS TO RECEIVE 5/6" DUROCK (1/2" MIN),
<br />FROM SLAB TO V-4 3/4" AFF INSTEAD OF GYPSUM BOARD IN TILED AREAS.
<br />ALL NEW & EXISTING NON -FIRE RATED WALLS TO RECEIVE 5/8" DUROCK (1/2" MIN), FROM SLAB TO 24" AFF INSTEAD OF GYPSUM BOARD
<br />IN COOK/KITCHEN/5ERVICE AREAS (5/8" PLYWOOD FROM 24" AFF TO CEILING IN COOK/KITCHEN/SERVICE AREAS). AT FIRE RATED PARTITIONS
<br />DO NOT REPLACE GYP. BOARD WITH DUROCK OR PLYWOOD
<br />- AT FIRE RATED PARTITIONS, G.C. SHALL MAINTAIN INTEGRITY OF FIRE RATED A55EMBLY AND LAMINATE NEW DUROCK BASE WITH GYP. BOARD
<br />OR PLYWOOD ABOVE (A5 SPECIFIED IN NOTE ABOVE) DIRECTLY TO FACE OF FIRE RATED PARTITION
<br />- CAULK MILLWORK TO PARTITIONS AND AT ALL CRACKS AND CREVICES
<br />- G.C. TO REPAIR/REPLACE WINDOW SHADES WHERE AFFICA5LE
<br />- G.C. SHALL FURNISH FIRE -RETARDANT -TREATED WOOD IN ALL ENCLOSED SPACES
<br />- ALL EXPOSED CORNERS ON COUNTERS, SHALL BE ROUNDED
<br />- REFER TO EQUIPMENT PLAN FOR TRENCH DRAIN LOCATIONS @ SERVICE & PREP AREAS
<br />- ALL ROOFING WORK AND PENETRATIONS TO BE PERFORMED BY L.L. ROOF CONTRACTOR @ G.C. EXPENSE. G.C. TO PROVIDE, A5 REQUIRED, VERIFICATION OF EXISTING
<br />STRUCTURE TO CARRY ALL NEW ROOF MOUNTED EQUIPMENT. G.C. TO PROVIDE AS REQUIRED, STRUCTURAL DESIGN FOR, AND ALL NECESSARY ADDITIONAL ROOF REINFORCEMENT & BRACING
<br />- ALL OUTSIDE CORNERS IN KITCHEN & DINING TO RECEIVE STAINLESS STEEL CORNER GUARDS, 5A5E TO 60" AFF (AT TILED AREAS IN DINING, FROM 5A5E TO TOP OF TILE - SEE DETAIL, SHEET A-4)
<br />- WHERE WALL TYPES ARE NOTED AS SIMILAR (SIM), REFER TO FINISH PLAN FOR CLARIFICATION OF WALL FINISHES
<br />1. WORK DESK MILLWORK: G.C. TO FURNISH WHITE PLASTIC LAMINATE (FL-2) COUNTER AND ADJUSTABLE WHITE PLASTIC (FL-2) SHELVING ABOVE. SEE ELEV.,, SHEET A-2
<br />G.C. TO FURNISH 1" METAL CONDUIT, SHOWN DASHED, FROM SANDWICH WALL TO F05 WALL FOR FOS SYSTEM
<br />3. MILLWORK COUNTER - PROVIDE RED CORIAN SOLID SURFACE (C) COUNTERTOP - PROVIDE FRF ON REAR FACE - SEE DETAILS, SHEET A-2 SEE ELEVATIONS, 5HEET A-6
<br />4. NEW HALF HEIGHT PARTITION (HEIGHT VARIES) - SEE INTERIOR ELEVATIONS & PARTITION LEGEND.
<br />5. EXISTING WINDOW/STOREFRONT TO REMAIN (TYF). REKEY D00R5 FER TENANT & PROVIDE PANIC HARDWARE.
<br />6. EXISTING REAR DOOR TO 5E LOCKED IN THE CLOSED POSITION.
<br />7. PROVIDE 24"W x 18"D x 6"H CONCRETE CURB BENEATH SAFE; CONFIRM LOCATION/51ZE W/ FRANCHISEE PRIOR TO CONSTRUCTION
<br />8. PROVIDE 6" METAL STUDS 9 NEW PARTITION AS NEEDED. HATCHED WALL AT OFFICE INDICATES 6" BEARING WALL (15 GA 6" METAL STUDS (6005162-43) 0 12" O.C.)
<br />9. IN SERVICE AND FKEF AREA5, AT EXISTING CMU REAR WALL G.C. SHALL APPLY ONE LAYER 5/8" DUROCK FROM FLOOR UP TO 24" AFF, W/ ONE LAYER 5/8" PLYWOOD FROM 24" AFF TO CEILING W/ FRF FINISH OVER 7/8"
<br />FURRING (OR 3 5/5" METAL STUDS AT FLUM5ING WALL). AT EXISTING GYF BD LAMINATE ONE LAYER 5/8" DUROCK FROM FLOOR OF TO 24" AFF, W/ ONE LAYER 5/8" PLYWOOD FROM 24" AFF TO CEILING W/ FRF FINISH.
<br />10. APPROXIMATE LOCATION OF 6" FVC SLEEVE (SHOWN DASHED) FOR 5ODA LINE FROM A50VE CEILING TO INSIDE DRINK CABINET. CONFIRM SLEEVE W/ BEVERAGE VENDOR PRIOR TO INSTALLATION.
<br />PROVIDE EXTRA SODA LINES TO RUN BELOW 5LA5.
<br />11. ELECTRICAL PANEL LOCATION - SEE ELECTRICAL DRAWINGS
<br />12. TRENCH DRAIN & FLOOR SINK SHOWN DASHED. SEE FLOOR & EQUIPMENT PLANS AND FLUM5ING DRAWINGS
<br />13. DASHED BOX INDICATES HANDICAP ACCE5515LE FLOOR & APPROACH CLEARANCE (TYP)
<br />14. NEW TELEPHONE BOARD LOCATION - SEE ELECTRICAL DRAWINGS
<br />15. AT PUBLIC AREAS, AT EXISTING CMU WALLS, APPLY 5/8" DUROCK TO 4'-4 3/4" WITH 5/8" GYF BOARD A50VE ON 7/5" FURRING - FINISH WITH CERAMIC TILE AND PAINT (SEE FINISH PLAN AND ELEVATIONS).
<br />16. DASHED LINE INDICATES LOCATION OF NEW WALK-IN COOLER
<br />17. EX15T'G REAR EXIT DOOR TO REMAIN- REKEY PER TENANT, PROVIDE HARDWARE FER SCHEDULE, PROVIDE KICK PLATE ON INTERIOR SIDE.
<br />18. TOILETS AS SHOWN ARE BEING BUILT BY LANDLORD'S CONTRACTOR. SEE ENLARGED TOILET PLANS AND ELEVATIONS ON A-6. PROVIDE ALL FINISHES AND ACCESSORIES NOT PROVIDED BY LANDLORD.
<br />19. PROVIDE 5TAINLE55 STEEL SUPPORT LEG W/ SCREW TYPE LEVELLER @ UNDERSIDE OF MILLWORK COUNTERTOF - FLANGES AT TOP & BOTTOM (SEE PLAN FOR SPACING)
<br />20. EXISTING ONE HOUR FIRE RATED DEM151NG PARTITION (SHOWN HATCHED) TO REMAIN. SEAL ANY OPENINGS W/ UL APPROVED MATERIALS (SEE DETAIL THIS PAGE). LAMINATE 5/8" DUROCK AND 5/5" GYP 51) OR
<br />PLYWOOD OVER DEM151NG PARTITION (SEE BOLD NOTES ABOVE).
<br />21, G.C. TO PROVIDE 5TAINLE55 STEEL FINISH, OVER ONE LAYER 5/5" DUKOCK FROM FLOOR TO CEILING BEHIND COOK LINE HOOD. CONFIRM REQUIRED LENGTH OF 5T. 5TL. W/ EQUIPMENT VENDOR.
<br />5TAINLE55 STEEL FINISH SHALL EXTEND A MINIMUM OF 18" BEYOND HOOD ON EACH SIDE ANY WOOD 5LKG IN WALL OR PLYWOOD ON OFF051TE SIDE OF WALL (WITHIN 15" OF HOOD) SHALL 5E FIRE RETARDANT TREATED.
<br />22. PROVIDE H05E BIB CENTERED ON BACK WALL OF WALK-IN AT 18" 5ELOW WALK-IN CEILING (COODINATE WITH WALK-IN SHOP DRAWINGS)
<br />23. NEW 4" THICK CONCRETE SLAB TO 5E PROVIDED AT REAR 10' WIDE SLOCKOUT. NEW 5LA5 TO ALIGN W/ EXISTING ADJACENT 5LA5. NEW 5LA5 TO 5E 3000 F51 CONCRETE (MIN) OVER 10 MIL VAPOR BARRIER, REINFORCED W/
<br />WIRE MESH. DOWEL INTO EXISTING ADJACENT SLAB 6" DEEF W/ #4 BARS 0 4'-0" O.C.
<br />DOOR SCHEDULE
<br />NO. LOCATION SIZE DOOR FRAME RATING HARDWARE / REMARKS
<br />TYPE FINISH MATL FINISH
<br />lOOA
<br />ENTRY DOOR
<br />EXIST'G
<br />„
<br />3 -0 x 7 D
<br />1
<br />ALUM & TEMP
<br />GLASS
<br />EXIST'G
<br />EXTRUDED
<br />ALUM
<br />EXIST'G
<br />-----
<br />-
<br />REKEY FER TENANT; PROVIDE PANIC
<br />HARDWARE
<br />G.C. TO ENSURE THAT:
<br />100E
<br />ENTRY POOR
<br />EXIST'G
<br />1
<br />ALUM & TEMP
<br />EXI5T'G
<br />EXTRUDED
<br />EX15T'G
<br />-----
<br />3'-0" x 7'-0"
<br />GLA55
<br />ALUM
<br />A. THRE51HOLD5 DO NOT EXCEED 1/2"
<br />B. DOOR FU5H FULL FORCE DOE5 NOT
<br />EXI5T'G
<br />ALUM &
<br />G
<br />EX15T'G
<br />EXTRUDED
<br />EXIST'G
<br />-----
<br />IOOC
<br />PATIO D00R
<br />3'-0" x 7-0"
<br />1
<br />GLA55
<br />ALUM
<br />EXCEEED 8-1/2 1_135.
<br />MODEL 5CF-CAFE A5 MFD. 5Y ELIA50N, W/
<br />KITCHEN
<br />5TAINLE55
<br />ALL ARE & ACCESSORIES 5TAINLE55
<br />101
<br />COUNTER GATE
<br />FK 1" x 1'-6"W x 2'-2"H
<br />EXT. 5C WI)
<br />5TL
<br />_---
<br />----
<br />-----
<br />5TL F A 5H
<br />5TKAIGHT CUT, MOUNT TO COUNTER
<br />MODEL 5CG-3 AS MFD. BY ELIA50N, W/
<br />15TEEL
<br />5TAINLE55
<br />5TAINLE55
<br />9"X14" WINDOW. FULL LENGTH 5TAINLE55
<br />102A
<br />PREP ROOM
<br />PR 1" x 1'-6" x 6'-8"
<br />3
<br />EXT. 5C WE)
<br />5TL
<br />H.M.
<br />5TL
<br />-----
<br />FANEL5 50TH SIDES. ALL HARDWARE
<br />& ACCESSORIES 5TAINLE55 5TL
<br />1028
<br />REAR EXIT
<br />EX15T'G
<br />4
<br />H.M.
<br />FAINT F-4 0
<br />H M
<br />FAINT F-4 0
<br />INTERIOR
<br />-----
<br />REPLACE W/ HARDWARE SET #2
<br />3-0 x 7-0
<br />INTERIOR
<br />102C
<br />PREP ROOM
<br />3'-0" x 7'-0"
<br />2
<br />H.M.
<br />PAINT F-4
<br />H.M.
<br />PAINT F-4
<br />-----
<br />HARDWARE SET #3
<br />G
<br />ND/OR
<br />103
<br />MEN'5 TOILET
<br />31-011 11
<br />3 -0 x 7 -0
<br />2
<br />H.M.
<br />FAINT F-4
<br />H.M.
<br />FAINT P-4
<br />-----
<br />REPLACE W HA DWAKE 5ET #
<br />EXIST'G
<br />EXISTING HARDWARE -ADD AND/OR
<br />104
<br />WOMEN'S TOILET
<br />3'-0" x 7,-0"
<br />H.M.
<br />FAINT P-4
<br />H.M.
<br />PAINT F-4
<br />REPLACE W/HARDWARE SET #1
<br />REPLACE
<br />HARDWARE SET #3
<br />105
<br />OFFICE
<br />3'-0" x 7'-0"
<br />2
<br />H.M.
<br />PAINT P-4
<br />H.M.
<br />FAINT P-4
<br />_____
<br />PROVIDE 1" UNDERCUT
<br />HARDWARE SET #3
<br />106
<br />OFFICE
<br />3'-0" x 7'-0"
<br />2
<br />H.M.
<br />PAINT F-4
<br />H.M.
<br />PAINT P-4
<br />-----
<br />FROVIIDE 1" UNDERCUT
<br />NOTES:
<br />1. ALL DOOR HARDWARE SHALL BE HANDICAP ACCE5113LE (ADA APPROVED)
<br />W/ MAX EFFORT TO 5E 5 L135 INTERIOR; 81/2 LB5 EXTERIOR.
<br />2. LOCK5ET5 TO MFD 5Y 5CHLAGE, "AL 5EKIE5 5ATUKN" DE51GN HANDICAP ACCE515LE LEVER
<br />3. ALL HARDWARE 5HALL 5E HEAVY DUTY COMMERCIAL GRADE.
<br />4. CENTERLINE OF HARDWARE MOUNTING HEIGHT 5HALL BE BETWEEN 33'' AND 44" AFF
<br />5. REKEY ALL EXI5TING HARDWARE - PROVIDE MA5TER KEY FOR ALL DOOK5.
<br />6. ALL HARDWARE 5HALL HAVE FIN15H #U526D (SATIN CHROMIUM PLATED)
<br />7. EACH DOOR LEAF TO HAVE:
<br />a. 51LENCER5 A5 MFD BY TRIMCO OR EQ
<br />b. DOOR 5TOP5 A5 MFD BY TRIMCO OR EQ
<br />8. AT 5TOREFKONT DOOR5 #100A 1008 & 100C PROVIDE 51GNAGE IN 1" HIGH LETTER5 ON
<br />CONTKA5TING BACKGROUND TO READ "THIS DOOR TO REMAIN UNLOCKED WHEN THE BUILDING 15 OCCUPIED"
<br />9. AT 5TOKEFKONT DOOK5 #100A & 1005 PROVIDE PANIC HARDWARE TO MATCH DOOR MFR STANDARD
<br />10. ALL DOOR5 TO REMAIN KEYLE55 IN THE DIRECTION OF EGRE55
<br />11. PROVIDE 1" UNDERCUT AT OFFICE DOOR5 #105 AND #106
<br />HARDWARE SETS
<br />HARDWARE 5ET #1
<br />a. HINGE5 -11/2 PR, 5TEEL, BALL BEARING TYPE
<br />D. PRIVACY LOCK5ET (ADA ACCE5515LE)
<br />c. C1_05EK -HEAVY DUTY
<br />d. DIAMOND PLATE KICK PLATE- 34" H (BOTH 51DE5)
<br />e. ADA APPROVED 51GNAGE
<br />HARDWARE 5ET #2
<br />a. HINGE5 -11/2 PR, 5RA55, BALL BEARING TYPE
<br />W/ NON -REMOVABLE PIN5
<br />b. PU5H BAR EXIT DEVICE W/ ENTRY LOCK5ET TRIIM
<br />c. CL05ER - HEAVY DUTY
<br />d. ALARM - DETEX V40xE13 W/08-13KN-689 OUT5IDE TRIM\
<br />e. DIAMOND PLATE KICK PLATE- 34" H (INTERIOR 51DE)
<br />f. FEEPHOLE & BUZZER
<br />#1
<br />#2
<br />#3
<br />3'_21/2"
<br />n__r , ,ALE
<br />PANIC DEVICE
<br />(9 INTERIOR)
<br />KICK PLATE
<br />(TYF)
<br />45'-4"
<br />FLOOR PLAN
<br />A-1 f 5CALE:1/4" = 1'-0"
<br />ONE HOUR PARTITION A55EM13LY - UL PE51GN #U465
<br />25 MSG. 3 50' W/ 1 1/4" LEGS (MIN) FLOOR AND CEILING
<br />RUNNERS ATTACHED TO FLOOR AND CEILING W/ FASTENERS AT
<br />24" O.C. (MAX). ONE LAYER 50' TYFE'X' GYF5UM WALLBOARD
<br />ATTACHED TO EACH SIDE OF FLOOR AND CEILING RUNNERS AND
<br />25 MSG. 3 5/8" W/ 1 1/4" LEG5 (MIN) METAL 5TUD5 W/ 50' LIPS
<br />(MIN), 5FACED 24" O.C. WITH 1" TYFE'5' DRYWALL SCREWS 8" O.C.
<br />ALONG EDGES OF BOARD AND 12" O.C. IN FIELD OF BOARD.
<br />JOINTS ORIENTED VERTICALLY AND STAGGERED ON OFF051TE
<br />SIDES OF THE A55EMBLY. JOINT COMPOUND APPLIED IN TWO
<br />COATS TO JOINTS AND SCREW HEADS. PAPER TAPE 2" WIDE
<br />EMBEDDED IN FIRST LAYER OF COMPOUND OVER ALL JOINTS
<br />THICKNE55: 4 7/8" (MIN)
<br />LIMITING HEIGHT: PER 5TUD5
<br />AFFROX WEIGHT: 6 1'5F
<br />ERIC J. SAFFRAN
<br />ARCHITECT
<br />Preston Ridge Commons
<br />3155 North Point Parkway
<br />Building E - Suite 200
<br />Alpharetta, Georgia 30005
<br />Tel 770 619 5916
<br />Fax 770 619 5919
<br />LIC # AR 12885
<br />cC
<br />W
<br />AOL
<br />W
<br />U
<br />�.
<br />Ln
<br />z
<br />M
<br />M
<br />CL W
<br />LL O_joC
<br />_
<br />N
<br />O
<br />�mLL.
<br />0Ln>-
<br />U
<br />CL
<br />N
<br />d
<br />W
<br />N
<br />REVISIONS
<br />NO.
<br />DATE
<br />REVISION
<br />INDEMNIFICATION CLAUSE
<br />THE OWNER SHALL RELEASE,
<br />HOLD HARMLESS, AND INDEMNIFYTHE
<br />ARCHITECT WITH RESPECT TO: ANY
<br />CHANGES MADETOTHE CONSTRUCTION
<br />DOCUMENTS BYANYONE OTHER THAN
<br />THE ARCHITECT, OR CHANGES IN ANY
<br />ASPECT OFTHE WORK, OR FAILURE BY
<br />THE CONTRACTOR TO BUILD IN
<br />ACCORDANCE WITH THESE
<br />CONSTRUCTION DOCUMENTS
<br />COPYRIGHT 2010
<br />ERIC J. SAFFRAN,
<br />ARCHITECT
<br />THIS DRAWING IS THE PROPERTY OF
<br />ERIC J. SAFFRAN, ARCHITECT
<br />AND IS NOT TO BE REPRODUCED OR
<br />COPIED IN WHOLE OR IN PART.
<br />UNAUTHORIZED USE OF ANY KIND,
<br />INCLUDING USE ON ANY OTHER
<br />PROJECT IS PROHIBITED. IT ISTO BE
<br />RETURNED UPON REQUEST.
<br />SHEET TITLE
<br />FLOOR PLAN
<br />PROJECT SHEET NO.
<br />NO
<br />1030
<br />HARDWARE 5ET #3
<br />a. HINGES - 1 1/2 PR, BRA55, BALL BEARING TYPE
<br />b. CLO5ER -HEAVY DUTY
<br />c. DIAMOND PLATE KICK PLATE - 34'' H (50TH 51DE5)
<br />d. OFFICE LOCK5ET (ADA ACCE5515LE)
<br />DOOR TYPES
<br />DRAWN BY
<br />EJ5
<br />DATE
<br />11-23-10I 1 OF 8
<br />
|