My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7840 Wheat Stone Dr
Zephyrhills
>
Building Department
>
Building Plans
>
7840 Wheat Stone Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 7:52:23 AM
Creation date
2/24/2025 10:14:48 AM
Metadata
Fields
Template:
Building Plans
Street #
7840
Location
Wheat Stone Dr
Contractor
D R Horton
Building Plans - Permit #
2427
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3ocuSign Envelope ID: 57BBOB27-E2C4-46E5-A844-3005B71F9F46 <br />0 <br />ri <br />rn <br />0 <br />N <br />1 st LEVEL FRAMING PLAN <br />1/4" = V-0" WHEN PRINTED ON 22"x34" <br />TRUSS FRAMING GENERAL NOTES <br />SEE SHEET ST-1 & 5 FOR ADDITIONAL GENERAL NOTES <br />• DRAFT STOPPING AT FLOOR TRUSSES TO BE PROVIDED <br />BY BUILDER <br />• UNLESS SPECIFICALLY NOTED ON TRUSS FRAMING PLAN, <br />ALL TRUSS TO WOOD CONNECTIONS SHALL BE ACCORDING <br />• <br />TO THE TYPICAL WALL SECTION, SEE SHEET ST-5. O <br />O <br />REFER TO COMPONENT MANUFACTURER'S LAYOUT FOR N <br />LO <br />TRUSS LABELS & DIMENSIONS <br />OVERFRAMING NOTES <br />0000 <br />• ALL RAFTERS TO BE MIN. 2x6 NO.2 SYP @ 24" O.C. MAX. <br />4 <br />• ALL "SLEEPERS" TO BE PLANK -ORIENTED 2x8 NO.2 SYP MIN. <br />O <br />• FASTEN "SLEEPERS" TO EACH TRUSS/RAFTER W/ (3) 16d <br />i <br />COMMONS MIN. <br />• EACH RAFTER TO "SLEEPER" W/ SIMPSON H3 UPLIFT <br />04 <br />N <br />CONNECTOR. <br />N <br />• ALL RIDGE BOARDS TO BE 2x8 NO.2 SYP MIN. <br />cM <br />• FASTEN 2x6 NO.2 SYP COLLAR TIES FROM RAFTER TO <br />_j <br />RAFTER WHERE APPLICABLE W/ (5) 10d COMMONS MIN. <br />LL <br />O.C. <br />12" <br />16" <br />24" <br />O.C. <br />--12" <br />24" <br />W <br />RAFTER SPAN SCHEDULE <br />J <br />- - - <br />- <br />J <br />LUMBER SIZE <br />5; <br />— - -- <br />Z <br />2x6 <br />2x8 <br />2x10 <br />2x12 <br />0 <br />15'-5" — <br />-19'-11" <br />23'-9" <br />26-0" <br />Y <br />13'-4" <br />17'-3" <br />20'-7" <br />22'-0" <br />a <br />10'-11" <br />14'-1" <br />16--10" <br />19'-9" <br />20 <br />L.L115 D.L. #2 SYP <br />O <br />O <br />CEILING JOIST SPAN SCHEDULE <br />T_ <br />W <br />LUMBER SIZE <br />i- <br />2x4 <br />2x6 <br />2x8 <br />2x10 <br />12'-5" <br />19'-6" <br />25'-8" <br />26-0" <br />11'-3" <br />17'-8" <br />23'-4" <br />26-0" <br />9'-10" <br />15'-6" <br />20'-1" <br />2T-11" <br />m <br />10 L.L./5 D_L_#2 SYP <br />TRUSS FRAMING KEY NOTES <br />a <br />C) <br />NOTES APPLICABLE ONLY WHERE SPECIFIED ON PLAN <br />G7 <br />1. SEE "SHEAR PANEL" DETAIL ON DETAIL SHEET. <br />} <br />U <br />2. TYPICAL BEARING BLOCK <br />Z <br />• BEARING BLOCK TO BE NO.2 SYP, MIN 48" LONG AND TO <br />w <br />0 <br />MATCH DIMENSION OF TRUSS MEMBER. <br />w <br />• ATTACH BEARING BLOCK TO TRUSS VERTICAL OR TRUSS <br />w <br />BOTTOM CHORD W/ (3) ROWS 10d @ 4" O.C. STAGGERED. <br />O <br />O <br />3. LEDGER FRAMING NOTES <br />CD <br />• FASTEN NO.2 SYP LEDGER TO FRAMING/TRUSS VERTICALS <br />ti <br />AT EVERY SUPPORT WITH FASTENING SHOWN BELOW <br />(MAX 24" O.C. SPACING). OR <br />• FASTEN NO.2 SYP PT LEDGER TO MASONRY/CONCRETE <br />w/ FASTENING SHOWN BELOW <br />• ADDITIONAL FASTENERS MAY BE REQUIRED AT SPECIFIED <br />Z <br />LOCATIONS ON PLAN <br />co <br />• SEE TABLE 5 ON SHEET ST-1/S1 FOR FASTENER <br />W <br />PROTECTION AGAINST CORROSION <br />Z <br />• EXTERIOR DECK LEDGERS SHALL BE SECURE TO WALL <br />FRAMING WITH WOOD SCREWS. COMMON NAILS AT FLOOR <br />z <br />LEDGERS ARE FOR INTERIOR USE ONLY. <br />00 <br />ROOF FRAMING LEDGER TO WOOD: <br />X <br />W <br />2x6...................................(4) 12d COMMON <br />W <br />2x8...................................(6) 12d COMMON <br />Z <br />2x10.................................(8) 12d COMMON <br />2x12.................................(10) 12d COMMON <br />Z <br />W <br />LEDGER TO CMU (W/ 3" TAPCON OR TITEN): <br />a <br />PT 2x6.......(2) ROWS %4" 0 @ 24" O.C. STAGGERED <br />0 <br />PT 2x8.......(2) ROWS %4" 0 @ 16" O.C. STAGGERED <br />of <br />PT 2x10.....(2) ROWS %4" 0 @ 8" O.C. STAGGERED <br />PT 2x12.....(2) ROWS %4" 0 @ 6" O.C. STAGGERED <br />LLLL <br />Z <br />FLOOR FRAMING LEDGER TO WOOD (W/ NAILS): <br />0 <br />2x6...................................(3) 16d COMMON <br />I- <br />2x8...................................(5) 16d COMMON <br />< <br />2x10.................................(7) 16d COMMON <br />Ix <br />2x12.................................(9) 16d COMMON <br />d <br />fr <br />FLOOR FRAMING LEDGER TO WOOD (W/ SCREWS): <br />O <br />PT 2x6...................................(3) 'W x 4-'/i' LONG #14 WOOD SCREWS <br />U <br />PT 2x8...................................(5) 'W x 4-Y2' LONG #14 WOOD SCREWS <br />PT 2x10.................................(7) 'W x 4-%" LONG #14 WOOD SCREWS <br />Q <br />PT 2x12.................................(9) Y4" x 4-'/z' LONG #14 WOOD SCREWS <br />O <br />4. ANGLE & LATERAL BRACES MAYBE OMITTED FROM GABLE <br />JI.L.L <br />BRACING DETAIL IF PORCH SHEATHING DETAIL IS <br />a <br />PROPERLY APPLIED, SEE DETAIL SHEET ST-6/7. <br />5. IF USING (2) HTSM20, INSTALL (1) STRAP ON EACH FACE OF <br />U <br />Z <br />THE WALL - (2) HTSM20 ON SAME SIDE OF WALL IS NOT <br />PERMITTED AT THIS LOCATION <br />�- <br />6. • (1) 48" & (1) 24" BEARING BLOCK REQ'D <br />OJ <br />• EACH BLOCK TO TRUSS W/ (3) ROWS 10d @ 4" O.C. <br />i <br />STAGGERED <br />Z <br />• TRUSS TO MASONRY BELOW W/ LGT3-SDS2.5 <br />2 <br />w <br />I— <br />X <br />w <br />a. <br />a <br />X <br />m <br />O <br />Q <br />O <br />LL <br />a <br />U) <br />O <br />J <br />O <br />Z <br />U <br />w <br />X <br />W <br />a <br />APEX <br />tds w <br />6 <br />true design studios <br />9000 REGENCY SQUARE BLVD. <br />SUITE 100, JACKSONVILLE, FL 32211 <br />a <br />w <br />LL <br />J <br />O <br />LLI <br />cLii <br />� <br />a <br />� <br />o <br />m <br />w 0 <br />o <br />J w <br />w <br />LIJ <br />X <br />Q <br />L;L, <br />z <br />O <br />0 <br />W <br />_Z <br />Il <br />LL <br />W <br />ABBOTT PARK Q <br />U <br />LOT 024-01 0 <br />W <br />Z <br />U) <br />PROJECT NO: LLI <br />2021.006623 0 <br />LL <br />-- - - - O <br />DRAWN: <br />KME o <br />CHKO: <br />MJP <br />w <br />a <br />U <br />`,`,�tt►t�it�������i cn <br />%% %. <br />DENS '9 .0 <br />• �\ �c'• Z <br />No 85166 <br />• 0 <br />� r 1 <br />i O ;• Tfv1CQRF435: 4U <br />i • <br />= 0 <br />,ORI . Z <br />ii*;Ss;O N A; ; .% <br />05-17-2021p <br />W <br />REVISIONS: <br />No. Description Date w <br />J <br />U <br />Z <br />O <br />0 <br />CMU/METAL CONNECTOR ENGINEERING <br />
The URL can be used to link to this page
Your browser does not support the video tag.