Laserfiche WebLink
:)ocuSign Envelope ID: 57BBOB27-E2C4-46E5-A844-3005B71 F9F46 <br />TRUSS TO TOP PLATE, MOISTURE BARRIER/ <br />UNO: BETWEEN MASONRY AND <br />• TRUSS LENGTH > 10 FT NON -PT LUMBER BY OTHERS <br />W/ H8 OR H10 <br />• TRUSS LENGTH </ 10 FT VERT. REINFORCING TO <br />W/ H2.5T OR RT7AT OR HAVE 10" STANDARD <br />SDWC15600 HOOK INTO BOND BEAM <br />• EVERY OTHER STUD TO TOP PLATE <br />W/ SP2 OR SPT24 OR SDWC15600 - <br />MAX 32'. O.C. F11 <br />EVERY KING STUD TO TOP PLATE <br />W/ SP2 OR SPT24 OR SDWC15600 <br />TYPICAL ROOF DECK <br />SHEATHING. SEE TABLE 2: <br />WOOD STRUCTURAL PANEL <br />SHEATHING REQUIREMENTS <br />ON SHEET STA <br />TRUSS OR RAFTER TO BOND <br />BEAM W/ META12 OR HTA16-18 <br />W/ MIN (7) 10d x 1 k" IN TRUSS <br />(NOTE: IF META12 OR HTA16-18 <br />IS IMPROPERLY INSTALLED, <br />ATTACH TRUSS TO BOND <br />BEAM W/ HTSM20 OR HTWM20) <br />FASCIA (SEE <br />ARCHITECTURAL) <br />PROPERLY WIND LOAD RATED <br />SOFFIT MATERIAL <br />CONTINUOUS @ PERIMETER. <br />SEE TABLE 1: COMPONENT <br />AND CLADDING DESIGN <br />PRESSURES ON SHEET ST-1. <br />(1) COURSE CMU BOND <br />BEAM W/ #5 CONTINUOUS <br />WALL SECTION AT ROOF (COMMON HEEL CONDITION) <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />• EVERY OTHER STUD TO BOTTOM PLATE <br />W/ SP1 OR SPT22 OR SDWC15450 <br />• EVERY KING STUD TO BOTTOM PLATE <br />W/ SP1 OR SPT22 OR SDWC15450 <br />2x_ NO. SPF OR BETTER @ MAX 16" O.C. <br />THREADED ROD ANCHOR W/ MIN 4" <br />EMBED W/ NUT & WASHER IN SIMPSON <br />ACRYLIC -TIE OR EQUIVALENT <br />ADHESIVE @ MAX 48" O.C. <br />OR <br />'/2' WEDGE BOLT W/ MIN 4'/2' EMBED W/ <br />WASHER @ MAX 48" O.C. <br />BOTTOM PLATE ANCHOR NOTES <br />■ EACH SILL PLATE SHALL HAVE A MIN. <br />OF (2) BOTTOM PLATE ANCHORS. <br />■ INSTALL ANCHORS WITHIN 12" OF EACH <br />END OF SEGMENT (BUTT JOINTS). <br />INTERIOR LOAD BEARING WALL <br />a <br />\ <br />yNa <br />a d I I <br />a <br />\/\ <br />EXTERIOR WALL <br />TYPICAL WALL SECTION AT FOUNDATION <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />8" PARTIALLY GROUTED <br />EXTERIOR CMU WALL W/ <br />VERTICAL WALL REINFORCING <br />PER STRUCTURAL PLAN, <br />SHEET S r-3 <br />OR ST-2A (IF APPLICABLE) <br />PROVIDE DOWELS TO MATCH <br />VERTICAL WALL <br />REINFORCING W/ MIN 30" LAP <br />(IF DOWEL IS OMITTED OR <br />IMPROPERLY INSTALLED, <br />DRILL AND EPDXY DOWEL OF <br />EQUAL SIZE W/ MIN. 6" <br />EMBEDMENT IN MONOLITHIC, <br />12" EMBEDMENT IN <br />MASONRY) <br />\X/ <br />/ <br />ROOF-] <br />COW <br />2x NO 2 SYP BLOCKING TO FIT TIGHT <br />BETWEEN TRUSSES, (3)10d TOE -NAIL @ <br />EACH END, BLOCKING MAY BE OMITTED <br />FOR HEEL HEIGHTS < 9" <br />FOR MISLOCATIO <br />3/4" BETWEEN TOP OF WOOD PANEL FASTEN 2x6 NO. 2 <br />AND CENTER OF FASTENERS. TO TRUSS W/ MIN <br />MIN 1%2' EXPOSURE 1 PLYWOOD RIM @ RAISED FOR MISLOCATIO <br />HEEL TRUSSES INSTALLED WITH LONG INSTALL NEW MA: <br />DIMENSION PERPENDICULAR TO TRUSS END STRAP TO INSIDE <br />VERTICALS, ATTACH TO TRUSSES AND <br />BLOCKING W/ 10d @ 3" O.C. <br />FASCIA (SEE ARCHITECTURAL) <br />PROPERLY WIND LOAD RATED SOFFIT <br />MATERIAL CONTINUOUS @ PERIMETER. <br />SEE DESIGN CRITERIA AND LOADS: C&C <br />DESIGN PRESSURES ON SHEET ST-1. <br />TRUSS OR RAFTER TO BOND BEAM W/ <br />META12 OR HTA16-18 W/ MIN (7) 10d x 1 <br />IN TRUSS (NOTE: IF META12 OR HTA16-18 <br />IS IMPROPERLY INSTALLED, ATTACH <br />TRUSS TO BOND BEAM W/ HTSM20 OR <br />HTWM20) <br />WALL SECTION AT ROOF (RAISED HEEL CONDITION) <br />THIS DETAIL IS APPLICABLE FOR BOTH 1 & 2 STORY APPLICATIONS <br />GENERAL NOTES APPLICABLE TO ALL: <br />MISLOCATED TRUSS ANCHORS <br />BLOCKING NOT SHOWN FOR CLARITY <br />-CORNERS <br />8" CMU BOND BEAM <br />BOND BEAM REINFORCING <br />AT CORNERS <br />ALTERNATE WALL SECTIONS & TYPICAL DETAILS <br />1. ALL TOP PLATES ARE TO BE BUILT WITH (2)2x_ NO. 2 SYP FASTENED W/ (2) ROWS 10d @ 8" O.C. STAGGERED (UNO). MINIMUM 48" LAP W/ MINIMUM <br />(20)10d IN LAP. ADJUST TYPICAL NAIL SPACING AS NEEDED. <br />2. ALL EXTERIOR BOTTOM PLATES ARE TO BE 2x NO 2 SYP PT. <br />3. ALL INTERIOR BOTTOM PLATES ARE TO BE 2x_ NO 2 SYP PT. <br />4. ALL INTERIOR LOAD BEARING WALL STUDS ARE TO BE MINIMUM 2X4 NO 2 SPF AT 16" O.C. UNLESS NOTED OTHERWISE ON FRAMING PLAN. <br />5. FOR SHEATHING SIZE AND FASTENING REFER TO TABLE 2: WOOD STRUCTURAL PANEL SHEATHING REQUIREMENTS ON SHEET ST-1. <br />6. FOR EXTERIOR WALL STUD SIZE AND SPACING, REFER TO TABLE 3: MAXIMUM EXTERIOR WALL STUD SIZES ON SHEET ST-1. <br />7. FOR EXTERIOR CMU WALL VERTICAL WALL REINFORCING, REFER TO DOWEL PLACEMENT PLAN ON SHEET ST-2A <br />8. FOUNDATION INFORMATION ON THIS PAGE IS FOR GRAPHICAL DEPICTION ONLY. REFER TO FOUNDATION PLAN AND SECTIONS FOR FOUNDATION INFORMATION. <br />9. WALL SECTION AT FOUNDATION AND WALL SECTION AT ROOF ARE TYPICAL FOR ONE AND TWO STORY APPLICATIONS. <br />U <br />0 <br />N <br />0 <br />N <br />STEP DOWN TIE -BEAM <br />DIST. FROM DOOR JAMB <br />MIN. SCREW <br />DIST. FROM DOOR JAMB <br />MIN. SCREW <br />/ WINDOW TO BLOCK <br />LENGTH <br />/ WINDOW TO BLOCK <br />LENGTH <br />3/' OR 11/4' <br />PER MANUF. <br />3" <br />5" <br />11/2, <br />3 /4" <br />3 7/16 <br />5„ <br />115/16 <br />3 3/4' <br />3 3/4 ' <br />6„ <br />2 %4" <br />33/4' IF <br />TITEN OR TAPCONS SCREWS SEE TABLE <br />ABOVE FOR LENGTH: <br />• (2) ROWS %" DIA. @ 30" O.C. STAGGERED <br />• (2) ROWS 3/6' DIA. @ 24" O.C. STAGGERED <br />DOOR JAMB OR WINDOW ATTACH TO <br />1x_ PER MANUFACTURER'S DETAILS <br />DISTANCE FROM BLOCK TO DOOR <br />JAMB OR WINDOW, SEE TABLE <br />ABOVE (SHIM AS NEEDED TO <br />PLUMB JAMB, DO NOT EXCEED '/.") <br />1x_ PT NAILER <br />BUILT UP 2x ATTACHED TO MASONRY, (1) PLY <br />1 x_ OR �6 OSB MATERIAL MAY ATTACH TO WALL <br />DRYWALL <br />8" CMU WALL <br />TYPICAL DOORMINDOW JAMB TO BLOCK <br />(TYPICAL FOR ALL MASONRY OPENINGS, UNO) <br />O <br />O <br />N <br />u7 <br />N <br />O <br />d' <br />O <br />O <br />N <br />N <br />m <br />J <br />LL <br />w <br />J <br />J <br />z <br />O <br />0 <br />Y <br />U <br />0 <br />O <br />w <br />H <br />> <br />J <br />m <br />w <br />w <br />Q <br />Z) <br />f� <br />z <br />w <br />0 <br />w <br />w <br />O <br />O <br />O <br />W <br />t` <br />It <br />LO <br />t` <br />z <br />U) <br />w <br />cn <br />m <br />w <br />w <br />z <br />z <br />w <br />O <br />J <br />LL <br />0 <br />f= <br />O <br />a <br />O <br />U <br />Q <br />0 <br />O <br />J <br />LL <br />Q <br />U <br />z <br />Q <br />O <br />J <br />O <br />z <br />U <br />w <br />x <br />w <br />d <br />Q <br />X <br />m <br />w <br />J <br />O <br />Uj <br />z <br />O <br />1= <br />U- <br />U) <br />C� <br />O <br />J <br />O <br />z <br />U <br />w <br />I— <br />X <br />w <br />Q <br />CMU/METAL CONNECTOR ENGINEERING <br />i1 <br />AX <br />t S <br />SD <br />J` <br />true design studios (D <br />9000 REGENCY SQUARE BLVD. <br />SUITE 100, JACKSONVILLE, FL 32211 <br />(D <br />M <br />W <br />w <br />J <br />0 <br />W <br />X <br />x <br />aLL <br />z <br />0 <br />w <br />H <br />z <br />R <br />0- <br />ILL. <br />w <br />ABBOTT PARK Q <br />U <br />_ (n <br />LOT 024-01 0 <br />w <br />-- - F­ <br />Z <br />C� <br />U) <br />PROJECT NO. <br />w <br />0 <br />2021.006623 <br />LL <br />DRAWN: <br />KME <br />o <br />O <br />U')CHKD <br />MJP <br />cn <br />w <br />J <br />Q <br />U <br />,11111111►11 , <br />1N LA /I✓ jF �,� <br />U) <br />c/) <br />J5� <br />No 85166 <br />Q <br />by:6EF435%�� <br />L_D_Tf,"CCbocus®ned <br />i <br />j <br />0NAi <br />05-17-2021 <br />w <br />REVISIONS: <br />TZ <br />No. <br />Description <br />Date <br />~ <br />w <br />J <br />U <br />c� <br />H <br />-- — <br />O <br />- <br />Z <br />ST=5 <br />