Laserfiche WebLink
)ocuSign Envelope ID: FC94054D-7E43-4269-B70C-400359B309DD <br />V1.0 <br />GENERAL FOUNDATION NOTES: <br />OP <br />8'-0" 59'-10" 0' <br />■ ■ - - - - - - - - - ■ ■ ■ I ■ 1 ■ ■ ■ , ■ ■ <br />■ - - - - - - - - - - - - - - - - - - - - - - - - - - 1- - - - - - - - - - - - - - - - - - - - - - - - -' - - - <br />i" � <br />H <br />:....:. .... ..... .... .....- <br />NI <br />I NI T-2.D C?l I■ <br />I <br />I I C?I <br />1 <br />-4" I oil <br />I I <br />B ■ 1 I I I _ 1 I■ <br />■ Imo/—I--------151-11'-—--- �2'-6oil <br />_ _■ I _ 6 -1 oil <br />T T-2.D OPT 1 N1 <br />— — — — I <br />z I 1 1 I■ .� ■ ■— <br />\ I 1 T-2.D -I— -- I <br />U) <br />I�0 I I o A I <br />I 100 I 1 <br />I � 1 I OPT T 2.D 64" 5.0„ <br />Iwo — — J -- <br />r-I r--------- ■ ■ v ■ <br />ry <br />I 1 1/2" 1 I I I I■ <br />I I I I 4 5 I■ <br />■( 1 I I T-2.D T-2.D <br />I T-2. D 1 1 1 <br />C? ;\ <br />r—————— — — — — —- <br />I ;:........... I T-2.D <br />oil 4" <br />J EO --- A <br />.. ........................... <br />I 1 UNDER DOOR <br />I I t- <br />1 <br />I I <br />1 I 1 1 9 1/2" <br />1 4W 1/2" ——4'-6"— — _Z-1" — — — — — — 11'-5" — — — — — 2'-4 1/2" 20'-8 1/2" <br />I T-2.D I <br />--- <br />T-2.D — \\ <br />I I � <br />VERIFY AC COND 29'-6" 5'-0" 14'-0" I <br />LOCATION W/ - - — -- <br />SITE PLAN ■ I I I of, <br />T-0" -0' 1 <br />T-2.D 1 I 4 <br />5 <br />O I I N1 : M I I I I■ <br />— — — — — — — — — — — — — — — — — — — — — — — <br />o <br />5 SIM 9" CURB <br />T-2.D VERIFY AC COND <br />-�9 LOCATION W/ <br />SITE PLAN <br />3'-0" <br />FOUNDATION PLAN <br />1/4" = V-0" WHEN PRINTED ON 22"x34" <br />N <br />0 <br />is <br />• CONCRETE SLAB ON GRADE SHALL BE MINIMUM 3 1/2" THICK AND a <br />HAVE MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 2500 PSI UNO. O77 O <br />• EARTH AND EARTH FILL SUPPORTING SLABS CI GRADE 0 � APEX <br />ASSUMED TO HAVE A MINIMUM BEARING CAPACITY OF 2,000 psf, AND C <br />SHALL BE FREE OF ORGANIC MATERIAL AND COHESIVE SOILS. N U <br />COMPACT THE FILL IN 12" LIFTS TO AT LEAST 95% OF MODIFIED op (D <br />PROCTOR MAXIMUM DRY DENSITY. IT IS THE OWNER'S OR <br />CONTRACTOR'S RESPONSIBILITY TO CONFIRM THESE ASSUMPTIONS. O a) <br />• IF CONTRACTOR OR BUILDING OFFICIAL DETERMINES THAT THE O Q <br />SOIL IS NOT SUITABLE FOR 2,000 PSF BEARING CAPACITY, CONTACT ' <br />EOR. ADDITIONAL FOUNDATION WORK MAY BE REQUIRED. <br />• SLIDING GLASS DOOR FRAMES MUST BE RECESSED INTO THE SLAB 04 <br />04 <br />IN ACCORDANCE WITH THE BUILDING CODE. CONSULT N <br />ARCHITECTURAL PLANS FOR LOCATION OF SLIDING GLASS DOORS. c? <br />• MASONRY STEMWALL AND MONOLITHIC FOOTINGS ARE � d C, <br />INTERCHANGEABLE. SEE SHEET ST-2D FOR ALTERNATE STEMWALL <br />SECTIONS. <br />• 24" LONG #4 BAR IS RECOMMENDED TO BE INSTALLED AT ALL _j t S <br />RE-ENTRANT CORNERS, SEE "RE-ENTRANT CORNER DETAIL" ON J a)SHEET ST-2D. true design studios <br />Z <br />_ O <br />FOUNDATION KEYNOTES: DC1 U 9000 REGENCY SQUARE BLVD.'' <br />NOTES APPLICABLE ONLY WHERE SPECIFIED ON PLAN SUITE 100, JACKSONVILLE, FL 32211 <br />OI <br />EDGEDEEP <br />w (P) #4THICKENED <br />D B COLDEEP FTG UMN, FTG TO BER BOX O c`a <br />PROJECTED MIN 6" AS SHOWN W <br />24"SQx20" DEEP FTG a)C 16"SQx12" DEEP FTG DI w/ (3) #4 EW U) DoRsHOMON' <br />N <br />30"SQx20" DEEP FTG F 36"SQx20" DEEP FTG 0 s <br />E w/ (4) #4 EW w/ (4) #4 EW _I <br />00 <br />L#5 VERTICAL DOWEL TYP <br />I 48"SQx24" DEEP FTG W e <br />I w/ (5) #4 EW, T&B l H AS SHOWN, SEE MASONRY ~- <br />NOTES ON ST-1 < <br />CI 1 1/2" SLAB EXTENSION <br />AT FULL ROUGH <br />OPENING WIDTH ) <br />N <br />Z <br />W <br />(D <br />W <br />O <br />O <br />O <br />***NOTE TO CONTRACTOR*** <br />- - <br />DR HORTON DOES NOT ALLOW FIBERMESH AS AN <br />ALTERNATIVE TO WWF AS SPECIFIED IN THIS PLAN SET I�f)>= <br />BORA-CARE OR OTHER DR HORTON APPROVED WOOD DESTROYING z a <br />ORGANISM TREATMENT TO BE APPLIED AS DIRECTED BYPRODUCT w <br />MANUFACTURER AND DR HORTON. U U. N <br />- - w L.L <br />z J Z w <br />00 <br />LU O Cn <br />w <br />w Q Z_ <br />(D > Q Q <br />w w o <br />o � -w LU <br />LLI w <br />,d. <br />J X <br />LL <br />LL <br />O OZ <br />W <br />d z <br />O a- <br />U IL <br />w <br />Abbott Park C <br />0 <br />U_ LOT 004-03 0 <br />H <br />_z z <br />PROJECT NO: w <br />2021.003498 w <br />= DRAWN: LDG o <br />�A U O <br />51_ Ljj CHKD: - — L0 <br />Ild ~ MJP <br />� X <br />w LU <br />gP�oN\ 1 Q `�rrrrri��►���� U) <br />-110 <br />A/V <br />5 ♦ <br />1 0 • �ceSi��edby <br />Z <br />P� V w O ,r MATE OF : �k/� <br />Is <br />Q �, 5If 4 6 Iq I D ♦♦ 435... z <br />'bo�_O 03-23-2021 p <br />vV ~ w <br />REVISIONS: LU <br />L U_ _ T_ <br />Q No. Description Date <br />w <br />J <br />SANITARY ISOMETRIC 1 __ o <br />= o <br />U <br />w <br />x <br />w <br />ST=2 <br />CMU/METAL CONNECTOR ENGINEERING <br />