Search
7983 Wheat Stone Dr
Zephyrhills
>
Building Department
>
Building Plans
>
7983 Wheat Stone Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 12:23:05 AM
Creation date
2/24/2025 10:15:41 AM
Metadata
Fields
Template:
Building Plans
Street #
7983
Location
Wheat Stone Dr
Contractor
D R Horton
Building Plans - Permit #
1924
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
7ocuSign Envelope ID: FC94054D-7E43-4269-B70C-400359B309DD <br />EXISTING EXTERIOR CMU = <br />MIN. 3" EDGE DISTANCE <br />STRIP OF WWF FROM F.F.E. TO <br />MIN. 6" BELOW GRADE. WWF TO <br />EXISTING FOUNDATION FACE w/ p p - - - - - o -- <br />--- ,I <br />(2) ROWS OF 3/s' DIA. TAPCONS / D D p <br />OR CUT NAILS @ 24" O.C. COVER <br />FLUSH w/ 3000psi CONCRETE. 9 <br />D - EXISTING FOUNDATION. <br />D p <br />p D <br />D \ \ p <br />p <br />D <br />8" CMU WALL OVERHANGS LESS THAN 1" <br />GROUT BOTTOM 3 COURSES <br />OF EXISTING CMU WALL FOR <br />LENGTH OF OVERHANG. FILL <br />TO BOTTOM OF WINDOW SILL <br />WHERE NEEDED <br />dill'":IsTel■ <br />STRIP OF WWF FROM F.F.E. TO <br />BOTTOM OF FTG. WWF TO <br />EXISTING FOUNDATION FACE w/ <br />(2) ROWS OF 3/6" DIA. TAPCONS <br />OR CUT NAILS @ 24" O.C. COVER <br />FLUSH w/ 3000psi CONCRETE.- <br />r <br />p � � <br />STING FOUNDATION <br />8" CMU WALL OVERHANGS 2.5" OR LESS <br />NOTES: <br />• IF EXISTING REBAR DOES NOT MEET 3" EDGE DISTANCE REQUIREMENT, <br />REMOVE INSIDE FACE SHELL OF EXISTING CMU WALL AT ADJECENT CELL <br />AND DRILL & EPDXY NEW FULL HT. VERTICAL #5 DOWEL W/ 12" EMBED INTO <br />EXISTING FOUNDATION AND 4" EMBED INTO EXISTING BOND BEAM. <br />• IF MORE THAN (3) BARS DO NOT MEET THE REQUIRED 3" EDGE DISTANCE, <br />CONTACT EOR. <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />° 4 <br />A ° <br />SEE ARCH <br />- - - (MAX 20" <br />° DEEP) <br />a 4„ <br />4" EXTENSION <br />UNDER BRICK VENEER <br />12" UNDER 1 STORY WALL VAPOR BARRIER <br />16" UNDER 2 STORY WALL <br />*-EARING CURB STEP SECTION <br />CONCRETE SLAB w/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />-n--,- - -- --- e -- -a <br />4 ° 4 �, \ <br />iC. <br />VAPOR BARRIER <br />*aEARING WALL FOOTING SECTION <br />12" <br />2- <br />LAP #5 CONTINUOUS BAR AS <br />NEEDED, MIN 12" LAP AS SHOWN <br />NO.5 BAR BEND 90 DEGREE <br />L I __ <br />L - - - - - <br />CONTINUOUS CONCRETE <br />FOOTING, SEE PLAN <br />TYPICAL STEP IN FOOTING DETAIL, <br />CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />- <br />8" CMU CHAIR <br />TOP OF SLAB <br />BLOCK W/ (1) #4 OR #5 CONT. <br />of <br />VAPOR BARRIER <br />/\\_ <br />o <br />LO <br />#4 OR #5 VERT REINFORCING �%/\�%/ <br />UP TO 3 COURSES: 72" O.C. \/\ /\/\ <br />4 TO 5 COURSES: 48" O.C. > / /�\/ Z�/\. <br />L <br />FOOTING TO BEAR ON FIRM /�\ j \' \\/ #5IN ONAL BIRICK EDGE <br />UNDISTURBED SOIL <br />VERTICAL REINFORCEMENT - 4" OPT BRICK LEDGE <br />TO HAVE 6" BEND AT BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />C STEMWALL SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />0'-0" A.F.F. Iih <br />(BEYOND) <br />FLOATING CONCRETE w U-BLOCK W/ <br />SLAB W/ 6x6 W1.4xW1.4 v J (1) #4 OR #5 <br />WF OR FIBERMESH > ti Q Q w CONT <br />W <br />• --- - - s J U) o: <br />` FINISH <br />O GRADE <br />LO <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C. <br />4 TO 5 COURSES: 48" O.C. o <br />o <br />FOOTING TO BEAR ON FIRM /\ <br />UNDISTURBED SOIL - ADDITIONAL #4 OR <br />#5 IN BRICK LEDGE <br />VERT REINFORCEMENT TO <br />HAVE 6" BEND @ BOTTOM 4" OPT BRICK LEDGE <br />NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS - <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />7 STEMWALL CURB SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />CMU STEMWALL MONOLITHIC SLAB 3 %2' CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR FIBERMESH <br />8" CMU CHAIR BLOCK W/ (1) #5 <br />-\I 4 <br />CONTINUOUS TO EXTEND MIN 24" MINIM 24" (1) #4 OR #5 90° BEND @ 48" O.C. <br />INTO MONOLITHIC THICKENED EDGE (1) #4 OR #5 CONT. <br />MIN 24" LAP <br />VARIES PER <br />36" MAX -° - - - -- - - - <br />ARCH PLANS <br />4" CONCRETE SLAB W/ ° 4 <br />6x6 W1.4 x W1.4 WWF <br />- - - 0_._ ..__ _� - _,- - - - --"-° OR FIBER MESH \\/ j\\/j\// \ 2\MIN �� ° \\ <br />° ✓�'�/ VAPOR BARRIER <br />U) - - - - - - - ° a ° ° ° ° $ #4 OR #5 \\/�\\//\ \ /\// /` 4" V/ FOOTUNDING <br />TO B SOIL <br />ON FIRM <br />0 � j 9 ° ° ° °° REINFORCING PER \/\\/\ \/, / \ <br />Z ° o ° MONOLITHIC FOOTING <br />Q ! ° ° SECTION 6" OPT. EXTENSION b <br />M � • a <br />° . a IN BRICK LOCATIONS <br />° FOOTING TO BEAR ON FIRM ON FND PLAN <br />° ° ° UNDISTURBED SOIL 12" UNDER 1 STORY WALL W% (2) <br />\�\ °\ \ ° \ ADDITIONAL NO. 4 OR NO. 5 #4 OR (2) #5 CONT <br />° ° ° MIN12" ///�\/�\/////\ BAR IN BRICK LEDGE 16" UNDER 2 STORY WALL W/ (3) <br />° _ -A #4 OR (2) #5 CONT - - <br />\\/\\/\\/\\/ \\/\\/\\/\\/\\\ \\,\\ MONOLOTHIC FOOTING SECTION - 36 MAX DEPTH <br />STEMWALL FOOTING TO EXTEND MIN <br />12" BELOW MONOLITHIC FOOTING 'NOTE': IT IS ACCEPTABLE TO SUBSTITUTE THIS "1A" FTG DETAIL FOR THE "1.. <br />//\//\//\//\//\\// • ADDITIONAL #4 OR #5 VERTICAL TO BE <br />FTG DETAIL SPECIFIED ON THE FDN PLAN @ ANY LOCATIONS THAT THE FTG <br />.// LOCATED WITHIN TRANSITION ZONE DEPTH EXCEEDS 28". <br />LOCATE VERTICAL AND TIE INTO STEMWALL FOOTING REINFORCEMENT IN LAST REINFORCEMENT IF GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY FROM STRUCTURE <br />STEMWALL CELL STEEPER THAN 1'-0" VERTICALLY PER T-0" HORIZONTALLY, CONTRACTOR HAS <br />TWO CHOICES: <br />1. PRIOR TO CONSTRUCTION, SEEK GUIDANCE OF FOR TO PREVENT EROSION <br />CMU STEMWALL TO MONOLITHIC TRANSITION DETAIL OF SOIL. <br />2. USE STEMWALL FOOTING <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />b ° - <br />v <br />VAPOR BARRIER �\\' <br />FOOTING TO BEAR ON <br />FIRM UNDISTURBED <br />SOIL <br />SEE NOTES (MAX 16") v <br />0 <br />STUCCO OR DIRECTLY ADHERED <br />STONE CLADDING FINISH - MIN 6" Q, <br />O <br />N <br />rp"A�w <br />ALL OTHER EXTERIOR WALL <br />O <br />12" UNDER 1 STORY WALL w/ M <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO.4 OR NO. 5 J +, <br />BAR IN BRICK LEDGE LIL <br />16" UNDER 2 STORY WALL w/ u j <br />(2) #5 OR (3) #4 CONTINUOUS J <br />t S <br />J � <br />true design studios <br />T <br />NOLITHIC FOOTING SECTION z <br />TACT FOR PRIOR TO CONSTRUCTION IF ANY OF THEOWING OCCUR: Y <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" U 9000 REGENCY SQUARE BLVD. <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY Q SUITE 100, JACKSONVILLE, FL 32211 <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY 0 <br />PER T-0" HORIZONTALLYfO PREVENT EROSION OF SOIL. O <br />O 4- <br />CONCRETE SLAB w/ 6x6 <br />(2) #4 OR (2) #5 CONTINUOUS W1.4 x W1 A WWF OR W cy <br />cy <br />FIBERMESH F- <br />- - -° - - -A <br />- - - g- - - -- B,R+HOMDN ` N <br />° ° a 4 L <br />m <br />W <br />16" ;\\\; \ <br />VAPOR BARRIER Q <br />C� <br />U <br />3 BEARING WALL FOOTING SECTION Z <br />W <br />0 <br />W <br />CONCRETE SLAB W/ 6x6 if <br />W1.4 x W1.4 WWF OR O <br />FIBERMESH O <br />-- - 0'-0" A.F.F. O <br />SEE ARCH \ti <br />„ 4 ° <br />DETAILS LLO <br />4 i\ <br />8" MIN O r �J ^ <br />° J <br />Z w <br />8"x8" THICKENED 8" t(D LL L <br />FTG AT W <br />STEP-DOWN, SEE VAPOR BARRIER Z <br />PLAN W J Z W <br />4 CURB STEP SECTION m LLJ O w <br />w <br />8" UNDER MASONRY WALL Z < G <br />O 6"UNDER WOOD WALL (D Q <br />CONCRETE SLAB �-�--{ _J Z W Q <br />6x6 W1.4 x W1.4 WWF <br />I I W W <br />OR FIBERMESH VARIES ° 0 Q <br />SEE ARCH <br />° 4 (MAX 16") W UjLL <br />Z Z <br />VAPOR BARRIER \� j ° 4 �/\ \\'\\/\\//�\//�\//i\//\ 0 O <br />\> < <br />IY W <br />6" OPT. EXTENSION IN BRICK 0 (~ <br />LOCATIONS ON FND PLAN IZ Z <br />Of <br />d <br />12" UNDER 1 STORY WALL w/ O I' <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 U iy <br />BAR IN BRICK LEDGE - <br />16" UNDER 2 STORY WALL w/ ¢ W <br />� J <br />(2) #5 OR (3) #4 CONTINUOUS Abbott Park Q <br />5 GARAGE EXT WALL CURB SECTION OJ -- - <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE Q LOT 004-03 <br />FOLLOWING OCCUR: -- - LU <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" <br />U Z <br />•GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY Z <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY _0 <br />PER 3'-0" HORIZONTALLYfO PREVENT EROSION OF SOIL. W <br />PROJECT NO: W <br />CONCRETE SLAB W/ 6x6 O 2021.003498 O <br />W1.4 x W1.4 WWF OR <br />FIBERMESH Z - - - 0 <br />0'-0" A.F.F. SEE ARCH U DRAWN: LDG o <br />�-°-- - - - - -- (MAX 20" <br />DEEP) CHKD: MJP <br />\ --� ° ° <br />CL <br />EXTENSION x U <br />UNDER BRICK VENEER Q ,,��;N LA►�,�,�� co <br />12" UNDER 1 STORY WALL �" ��'JSi(,•E ►\/ N <br />w/ (2) #4 OR (2) #5 CONT VAPOR BARRIER m : •.••�,� `S$' Z <br />' DwQ5igaed-by 3: <br />16" UNDER 2 STORY WALL I. <br />w/ (3) #4 OR (2) #5 CONT Z <br />- _ 0 <br />BEARING CURB STEP SECTION O : 'S'YA � / <br />6 _- - <br />O STATE OF : ��/ <br />W U) <br />Q ,� 5D 435... z <br />TYPICAL REINFORCING <br />BARS AT THICKENED <br />FOOTING, SEE PLAN <br />MIN 24" LONG #4 OR #5 <br />BAR SET AT MID -DEPTH <br />OF SLAB, TYP ALL <br />RE-ENTRANT CORNERS <br />I - <br />,HOUSE SLAB <br />RE-ENTRANT CORNER DETAIL <br />(RECOMMENDED) <br />PLAN VIEW, DETAIL TYPICAL @ ALL <br />RE-ENTRANT CORNERS <br />Q <br />_O 03-23-2021 p <br />I- W <br />U REVISIONS: <br />Q No. Description Date <br />- W <br />(� Q <br />O- -- - --- - - H <br />ZO -- - -- Z <br />= O <br />U � <br />W <br />x <br />W ST=2mD <br />11 <br />CMU/METAL CONNECTOR ENGINEERING <br />