My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
2964 Lytton Hall Dr
Zephyrhills
>
Building Department
>
Building Plans
>
2964 Lytton Hall Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 5:16:36 PM
Creation date
2/25/2025 9:35:57 AM
Metadata
Fields
Template:
Building Plans
Street #
2964
Location
Lytton Hall Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
809
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general). In a Flood Zone, all electrical equipment to be at or above DFE. <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 44" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC. <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12, Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2014 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />OWP <br />WEATHERPROOF DUPLEX OUTLET <br />� GFd <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />13 <br />THREE-WAY SWITCH <br />14 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />�P <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />@ <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ICI] <br />ELECTRIC METER <br />ELECTRIC PANEL <br />d <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />C�� <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />69 <br />(1) PHONE LINE, (1) DATA PORT <br />POWER CO. <br />INTERSY <br />BON <br />TERMINATION <br />NEC 14, 250.94 <br />200A INDOOR PANEL <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Doper to lights & outlets <br />opper to 20 amp Me <br />copper" WH <br />copper to Dryer <br />t Alu <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />RECEPT. <br />FOR ALARM <br />SYSTEM <br />11' <br />VERIFY METER <br />LOCATION WITH <br />ENTRY <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: Y4'=1'-0" <br />0 <br />N <br />N <br />v <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drewings comply with the 2017 Florida Building Code - <br />Residential Bth Edition. Engineer's signature and seal <br />Is only for <br />the stnxdurel engineering portions of the drawing pages bearing <br />Ergineers signature and seal. <br />W <br />8 �+ <br />CC,, <br />O <br />— <br />0-isS ' <br />Ih <br />d) <br />oLLN� LL LL C. <br />' . tL N <br />a7 d) li C' d <br />Z <br />vmco <br />W <br />Asa W10 <br />2EcP dc� <br />IL <br />� <br />Z � J <br />° <br />z <br />❑❑❑ <br />W <br />c� <br />z <br />z <br />� <br />M <br />d N <br />(n <br />N <br />� <br />z <br />Ur s <br />LL <br />W <br />o <br />U <br />a <br />0 <br />� <br />'. <br />U <br />_ � <br />V' <br />V o <br />o <br />M <br />M <br />W <br />Z <br />Q <br />E O <br />s <br />o <br />oc <br />Z <br />O E <br />o to <br />N <br />o <br />: <br />do <br />o <br />� L <br />CO CY <br />�O <br />Z' <br />Z <br />a <br />w <br />o <br />W <br />2 <br />8 <br />U <br />az <br />z <br />ZIG <br />U 3 <br />r <br />� <br />> C'7 <br />L <br />O1 <br />B <br />^ <br />� <br />� <br />r <br />Q <br />am <br />co <br />/yQ <br />O0 0 <br />Q <br />00 <br />00 <br />■ t• <br />J Cq <br />Y <br />E00 <br />E <br />T— <br />CN <br />6i <br />o <br />Z <br />r_ <br />A <br />E Q <br />E <br />`o <br />wi <br />` <br />c <br />U <br />p <br />JOB <br />NO: <br />20-3569 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4.0 <br />