My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3108 Lytton Hall Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3108 Lytton Hall Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 9:35:27 AM
Creation date
2/25/2025 9:37:47 AM
Metadata
Fields
Template:
Building Plans
Street #
3108
Location
Lytton Hall Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
22763
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general). In a Flood Zone, all electrical equipment to be at or above DFE. <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 44" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC. <br />8, Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2014 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />wP <br />WEATHERPROOF DUPLEX OUTLET <br />�&GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />frl�.v <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />� 4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />{-� <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />200A INDOOR PANEL <br />CENTER <br />NEMA 1 <br />200 AMP <br />METER <br />MAIN <br />O <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED --- <br />INTERSYSTEM <br />BONDING O <br />TERMINATION PER 71 <br />NEC 14, 250.94 ��J// <br />copper to lights & outlets <br />copper to 20 amp ckts <br />2 copper to WH <br />3 copper to Dryer <br />or 4/0 SER Alu <br />Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />WP DISC. <br />GFI H. <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />unman non cn�r1c <br />O <br />EXHAUST FAN <br />--- <br />j <br />W.H. VERIFY LOCATION <br />�OGFI <br />_ _ _ _ _ <br />_ _ _ _ _ <br />_3 <br />ELECTRICAL PANEL <br />,, <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />1111111111-11111 <br />RECEPT. METIM <br />CH <br />CHIMES (OPTIONAL) <br />FOR ALARM VERIFY METER <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />SYSTEM LOCATION WITH <br />BUILDER <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />©2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />owl <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G T <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />ELECTRICAL PLAN - ELEV-Bl I <br />SCALE:1/4"=1'-0" <br />0 <br />N <br />0 <br />N <br />N <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and <br />seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />000 <br />v <br />Q <br />_ <br />� - <br />N 0W <br />N <br />V <br />O CD O 0) <br />O r N C <br />M N 0J <br />to J J <br />Lo N LL LL <br />eo <br />® <br />N <br />0) co m D <br />-J <br />� <br />J *k uj Lu <br />LL _j'Jct <br />Q <br />N <br />ii <br />0L <br />Lu W - M <br />a. rY O <br />Z <br />> <br />acna' <br />0 ❑g <br />0m0❑ <br />C N <br />m <br />W <br />Z <br />�E�rn <br />¢❑EL <br />O _ <br />Z <br />NaMZ <br />° Q <br />Q <br />V F J <br />❑❑❑❑ <br />W <br />C' <br />N <br />z o <br />z � QNQ <br />z Q <br />— <br />�1 M <br />� o <br />!� <br />z <br />vim_ <br />LL <br />1l <br />r <br />fQ <br />�% Y <br />W n <br />j� <br />O <br />lN <br />M <br />uJ F- <br />c o <br />wa <br />U m <br />u, c <br />allr— <br />2 E <br />— o 8 <br />=f <br />Q <br />soy <br />o <br />co <br />w <br />M <br />CO <br />�z <br />zo s <br />z <br />�Q <br />� <br />Q E <br />E <br />_� <br />M_ 0- <br />z <br />zZo <br />" 0 <br />pa <br />co <br />m <br />to <br />_ <br />o <br />❑ O <br />❑ <br />z <br />CN <br />~O <br />�o <br />Q <br />- <br />ww <br />r <br />�O L <br />- ra <br />Cy <br />❑ <br />m � <br />o <br />o0 <br />- <br />J <br />mo <br />z <br />rz <br />ziZ <br />N <br />¢ ° <br />s� <br />o <br />t? <br />oW <br />U <br />a <br />N <br />U � <br />� <br />F <br />J Z <br />= N <br />>O <br />o <br />co <br />w� <br />za <br />a <br />Ova <br />0 <br />CV <br />= <br />> d- <br />J <br />L <br />� <br />rn <br />W <br />m <br />0 <br />.> <br />rl-. <br />O <br />> <br />0 <br />O <br />Al m <br />co <br />2 <br />r <br />C3) <br />•� <br />J N <br />r <br />T <br />O <br />In <br />O N <br />M <br />Or <br />M <br />T <br />M 1- <br />o <br />Z <br />Z <br />E O <br />�; c1 <br />M <br />cc <br />a <br />E <br />0 _j <br />a <br />¢ o <br />� <br />c <br />3 <br />JOB <br />NO: <br />20-1133 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.