Laserfiche WebLink
N <br />N <br />NN <br />v <br />a <br />0 <br />a <br />0 <br />GV <br />CN <br />N <br />0 <br />En <br />w <br />m <br />> <br />0 <br />V) <br />ATTIC VENTILATION CALCULATIONS - B1 (TRB) <br />ATTIC VENTILATION REQUIRED <br />UPPER VENTILATION PROVIDED <br />1/150 Rule <br />1/300 Rule <br />Ridge <br />Off -Ridge <br />(No Upper Ventilators <br />(Must Provide Upper Ventilators) <br />Vent Amt <br />Amt. <br />Req.) <br />(Ft.) <br />Total <br />Ventilation <br />ATTIC <br />Provided <br />SPACE <br />SQ. FT. <br />Total SQ. <br />SQ. FT. <br />SQ. IN. of <br />by Upper <br />SQ. IN. of <br />of vented <br />IN. of <br />of <br />ventilation to <br />SQ. IN. of <br />SQ. IN. of <br />Ventilators <br />ventilation <br />soffit <br />ventilation <br />vented <br />be provided <br />Ventilation <br />Ventilation <br />(See Elev) <br />required <br />needed <br />required <br />soffit <br />by upper <br />needed <br />ventilators <br />Main <br />21.00000 <br />2.000000 <br />Floor <br />2377 <br />2282 <br />326 <br />1141 <br />81 <br />570 <br />0 <br />591.0 <br />315.0 <br />276.0 <br />(Zone 1) <br />**NOTE** <br />GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS <br />REQUIRED BY FBC 6th ED. RESIDENTIAL. <br />ROOF PLAN - ELEV-B1 <br />SCALE: %4"=V-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated. Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />-CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN** <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />�ryyr C A/ <br />"ISE - <br />� A <br />r <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />N <br />E v r- 00 <br />❑ N (O <br />O O O m co N J J <br />O N N C Z N lL LL <br />� � <br />Cr, <br />, <br />..�. CO J * W W <br />'7 L- LL LJL d c- <br />aLu <br />N Vl M W <br />W <br />W a s <br />Z <br />Z <br />>. [Y Y <br />-a coC 0 <br />cc m o 0 m 0 <br />C N r C0 J❑ <br />W <br />E� rn a 2 <br />Z <br />J❑ <br />NQC,)Z Q O Q_Q <br />Z <br />U ❑❑❑❑ <br />W <br />M <br />V M <br />—n <br />Z N O <br />� O <br />O N <br />z iz <br />J M <br />d N <br />M <br />v <br />U_ <br />.O <br />Gn x <br />w o <br />o a <br />N <br />E <br />0 <br />U 00 <br />w m <br />r— m <br />0 8 <br />= <br />a IPI <br />it III I <br />O < y <br />c � O <br />01 m <br />Aft <br />O <br />G,,3 <br />3 <br />w <br />z <br />z <br />o� <br />U_ <br />0_ <br />E Ov <br />W O <br />� <br />�O <br />cu <br />cu B <br />Cl <br />R0 <br />tt G <br />00 <br />0 <br />O <br />N¢ <br />i <br />o <br /><z <br />w W <br />°? <br />CnY <br />_ ❑ <br />U <br />Nm <br />mo <br />O� <br />zr <br />ZQT <br />J <br />Q W <br />2Z <br />fn <br />� <br />Q� <br />2 <br />�� <br />az <br />oZ <br />O <br />as <br />=3 <br />c9 <br />�o <br />GOO <br />w <br />zl< <br />d = <br />0 3 <br />�N <br />0 <br />= <br />` <br />J <br />L <br />O1 <br />cc <br />V <br />I\/ <br />■ — <br />O <br />/ <br />� <br />L_ <br />O <br />O <br />Q <br />CD <br />m <br />co <br />T <br />2 <br />V <br />T <br />■ � <br />J CN <br />0 <br />L , ,T^ <br />r <br />1� <br />o N <br />r <br />0 <br />T f <br />ui <br />M <br />CM ` <br />N <br />6 <br />Z <br />co <br />Z <br />E C7 <br />co <br />d <br />E <br />U _ <br />Q p <br />� <br />JOB <br />NO: <br />20-1133 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />5 <br />