Laserfiche WebLink
RR'll' I11viIIII "IrIF11"IMIFw I<IW1MrWIRIII if-, <br />-8" <br />A a S3 <br />35-SH <br />59'-4" <br />V-0" <br />16'-3" 5'-0" <br />H.B. <br />W LU d - - - - - - - <br />0 Z -r z _ I <br />_3 J I <br />c,4 LU <br />�N Cj ILE, <br />30'-0" in 4-la' '-3" PO6 <br />�I <br />ENTRY <br />8'-0" FLAT CLG. <br />15'-0" <br />1MILY ROOM VAULT.VAULT. CLG. CARPET� ��!=1111III_1111�111111111�11_IIr'�.�1111111111111_111�11111111[��111� <br />CARPET <br />.� <br />Lj <br />©002:12 SLOPE <br />- ----�� <br />LO <br />Li <br />to <br />rl91-01. 1 <br />- �- <br />- uu ® .wwwru•www, FIB .� EDGE OF SLAB 2" <br />■ ! ' �. <br />n ` -• • • ' i <br />■■ ■I <br />24 <br />WN <br />NEW <br />■I mom <br />0-1111 <br />OWN R'S <br />1 CARPET <br />.I�i �■ <br />• <br />SHOWER <br />- <br />- • <br />FIBERGLASS <br />4068 B.F. <br />RROUND <br />/-_ <br />uj <br />U') <br />4068 B.F <br />004 p - <br />i 0 us <br />MENNEN <br />0 <br />- •.: I• _ <br />- <br />1 I��- u 1=1 <br />50 <br />/ BEDROOM <br />.•• •• BEDROOM <br />- <br />- <br />- ' / • 1 - <br />I a -CARPET <br />�1111111111111111111[:111��Ii1i1111111CI1111111111111111CI11111111111111111CI1111111C1�[71111111111I7'1=1111111111111_11111111��Ii11=1111111111111111111111=11111111 <br />e O O <br />30'- <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H 1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2600 PSI <br />H6 <br />(2) -1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2600 PSI <br /><e> <br />LVL 2.0E Fb=2600 PSI <br />H8 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2600 PSI <br />(2) - 2X4 #2 SYP W/ 1/2" Follow Q/S4. See Plan for <br />R.A.G. FLITCH PLATE Bearing Wall Call Out When <br />Straps are Required <br />" VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20 X 26 <br />18 j X 25 } <br />S.H. <br />13 <br />20 X 38 j <br />18 } X 37 1 <br />S.H. <br />14 <br />20 X 501 <br />18 j X 50 <br />S.H. <br />15 <br />20 X 63 <br />18 j X 62 } <br />S.H. <br />16 <br />20X72 <br />18}X71} <br />S.H. <br />1 H2 <br />27 1/4 X 26 <br />26 X 25 j <br />S.H. <br />11­13 <br />27 114 X 38 j <br />26 x 371 <br />S.H. <br />1 H4 <br />27 J X 501 <br />26 x 50 <br />S.H. <br />1H5 <br />27jX63 <br />26X621/2 <br />S.H. <br />1H6 <br />27jX72 <br />26X711/2 <br />S.H. <br />22 <br />37 J X 26 <br />36 J X 25 1/2 <br />S.H. <br />23 <br />37 j X 38 j <br />36 j X 37 3/4 <br />S.H. <br />24 <br />37 J X 501 <br />36 1 X 50 <br />S.H. <br />25 <br />37 J X 63 <br />36 } X 62 1/2 <br />S.H. <br />26 <br />37 J X 72 <br />36 } X 71 1/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 J WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 } X 25 } <br />S.H. <br />33 <br />54 X 381j <br />52 j X 37 j <br />S.H. <br />34 <br />54 X 501 <br />52 } X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 } X 62 j <br />S.H. <br />36 <br />54 X 72 <br />52 } X 71 } <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection. <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection. Openings from a private garage <br />directly into a room used for sleeping purposes shall not be <br />permitted. Door between garage and residence shall be equipped <br />with solid doors not less than 1 3/8" in thickness, solid or <br />honeycomb -core steel doors not less than 1 3/8" thick, or <br />20-minute fire -rated doors. <br />R302.5.2 Duct Penetration. Ducts in the garage and ducts <br />penetrating the walls or ceilings separating the dwelling from the <br />garage shall be constructed of a minimum No. 26 gage (0.48 mm) <br />sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl <br />duct board, or other approved material and shall have no openings <br />into the garage. <br />R302.5.3 Other Penetrations. Penetrations through the separation <br />required in Section R302.6 shall be protected as required by <br />section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated from the dwelling as per the <br />following: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills. <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools, Section R4501.17.1.9 <br />All doors and windows providing direct access from the home to <br />the pool shall be equipped with an exit alarm complying with UL <br />2017 that has a minimum sound pressure rating of 85 db at 10 <br />feet. Any deactivation switch shall be located at least 54 inches <br />above the threshold of the access. Separate alarms are not <br />required for each door or window if sensors wired to a central <br />alarm sound when contact is broken at any opening. <br />M1507.2 Recirculation of Air. <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />recirculated within a residence or to another dwelling unit and shall <br />be exhausted directly to the outdoors. Exhaust air from bathrooms <br />and toilet rooms shall not discharge into an attic, crawl space or <br />other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above flr. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />OPENING PRESSURES <br />ENCLOSED-EXPOSURE"C" <br />A <br />+29.7 / -30.8 <br />© <br />+29.7 / -39.2 <br />© <br />+28.3 / -30.8 <br />OD <br />+28.3 / -36.4 <br />DE <br />+26.6 / -28.0 <br />OF <br />+26.6 / -32.2 <br />OG <br />SEE SN SHEET OH SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />1 +34.0 / -44.8 <br />WALL LEGEND <br />MASONRY HGT. @ V-0" A.F.F. <br />TYP. 2x FRAME WALL <br />INTERIOR BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR BEARING <br />ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND <br />REQUIRES NO UPLIFT CONNECTORS TO FLOOR <br />SYSTEM <br />AREA TABULATION <br />1ST FLOOR LIVING AREA 1817 <br />LIVING TOTAL 1817 <br />GARAGE 427 <br />FRONT ENTRY 32 <br />TOTAL AREA 2276 <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED <br />FLOOR PLAN ELEV B 1 EXT FRAME 2 x 6 R-1KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />SCALE: 1/4"-1'-0" GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />,�,�1��1gf1►11tuf/f����, <br />N NV_6 <br />,,... <br />U ,• Cho . ,>�,� <br />\o .. <br />' <br />6 0- 2 <br />16. <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Reeidential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />E o) <br />cs ``P"° <br />N <br />o 2 <br />M N r ro LL LL <br />��c <br />' <br />LL LL a a' <br />LL <br />(n N C, W h Q. <br />NCLL as UM, O <br />Z <br />0) 0IX o <br />°o <br />W <br />_ <br />-ro o � 'O ¢ ¢ p <br />i Ea rn d <br />Z <br />Z <br />0 <br />CY) N OR O N <br />WCq <br />NaG�Z°_ <br />Ov ❑❑❑❑ <br />C <br />z N <br />Z <br />Q� <br />J <br />N <br />z M <br />v <br />u- <br />_0 <br />Gn <br />LU <br />o <br />N <br />�N <br />W <br />c <br />� <br />� o <br />vC13d <br />0 <br />_ <br />Q � <br />4 <br />W <br />_ <br />o1 <br />1 <br />z0¢• <br />E <br />l-Q <br />oQ on <br />z <br />N <br />az <br />o <br />Kz <br />wO <br />m= <br />O <br />ZLL <br />ZC13C <br />rn J <br />< • <br />2 <br />O <br />W <br />N <br />a <br />v 3 <br />$q� <br />az <br />yW <br />�� <br />�� <br />N <br />O <br />aF <br />y0 <br />zla <br />a <br />U <br />.4 CV <br />= <br />ai <br />L <br />0) <br />.ica <br />c <br />CD <br />JCD <br />O <br />�1 <br />a <br />C o <br />-0 <br />CD <br />0 <br />T <br />N <br />0)� <br />•� <br />Z M <br />r <br />T <br />� <br />E <br />Z CD <br />M r <br />c <br />Z <br />Z <br />E 0 <br />Eo <br />h <br />• <br />Qj <br />`m <br />c <br />U � <br />Q <br />JOB <br />NO: <br />20-0556 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />1 <br />