Laserfiche WebLink
�111 I1�11�1�1'I 'mr i Irt ql � <br />J <br />ALL STAIR STRINGERS <br />AND TREADS TO BE <br />#2 SYP (MIN.) <br />THREADS, RISERS, AND <br />3/4" PLYWOOD NOT <br />SHOWN IN DETAIL FOR <br />CLARITY <br />ALL WOOD TO WOOD <br />CONNECTIONS TO BE <br />GLUED (PL 200) AND <br />NAILED (MIN. (2)16d). <br />1 3/4 x 11 <br />J VL <br />2x4 UNDER STRINGER - <br />GLUED AND NAILED TO <br />LANDING <br />2x4 UNDER STRINGER GLUED F <br />NAILED TO LANDING BLOCKING <br />D <br />2x4 PT NOTC <br />INTO STRINGER <br />H D <br />_-2x8 BLOCKING FOR STRAP <br />L-1x4 blocking <br />SIMPSON MSTA21 w/ (16) 10d NAILS E <br />FLAT STRAP NAILED TO RISER AND <br />THEN WRAPPED AROUND STUD <br />PLAN VIEW <br />SCALE- " = 1'-0" <br />NOTE: <br />THESE DETAILS ARE NOT PLAN <br />SPECIFIC. THEY ARE PROVIDED TO <br />YOU AS A STANDARD TO CONSTRUCT <br />STAIRS. REFER TO PLAN DETAILS <br />FOR RISE AND RUN INFORMATION. <br />2x4 SPF NOSING GLUED AND <br />NAILED MATCH NOSING ON <br />OTHER TREADS <br />�6, <br />JOIST <br />SYP <br />2x8 SYP <br />2x8 <br />SYP <br />STRINGER MUST MAKE FULL <br />CONTACT WITH LANDING <br />SIMPSON A35 OR <br />LSC EACH <br />STRINGER <br />2x4 CUT ON BEVEL — <br />DOES NOT BEAR IN <br />WALL GLUED TO <br />2x8 <br />F SE <br />STRINGER MUST MAKE <br />FULL CONTACT WITH LANDING <br />SIMPSON A35 OR <br />LSC EACH <br />STRINGER_At <br />i <br />2x4 CUT ON BEVEL <br />DOES NOT BEAR IN <br />WALL <br />2x SYP CUT TO FIT <br />BEARS IN WALL <br />------2x12 SYP <br />BEARS IN WALL <br />�-2x6 SYP <br />B� <br />2x12 SYP— SCAB 2x4 GLUED AND NAILED (EACH <br />ALIGN THIS STUD WITH STRINGER SIDE) TO BOTTOM EDGE OF 2x12 <br />FACE OF 2ND RISER 3/4" RISER CUT TO FIT STRINGER <br />_ MAINTAIN BETWEEN J" <br />AND J" GAP TOP AND <br />BOTTOM, GLUED AND <br />NAILED TO STRINGER / <br />2x4 BEHIND RISER <br />BLOCKING FOR <br />1x4 GLUED AND NAILED TO STRINGER STRAP GLUED TO <br />2x4 DRAFT RISER AND TREAD <br />STOP <br />2x8 SYP DRYWALL STOP MUST <br />NOT TOUCH STRINGERS <br />LAI <br />`- 2x4 SYP BLOCKING ` <br />2x4 PT NOTCHED INTO STRINGER FOR STRAP <br />AND NAILED TO FLOOR WITH GLUE (SIMPSON MTS12 w/ <br />/ AT STRINGER CONTACT POINTS \ (14) 10d x 1 1/2" NAILS) <br />CTION VIEW "A" <br />SECTION VIEW "B" <br />SCALE: 1" = 1'-0" SCALE: 1" = 1'-0" <br />ALIGN THIS STUD WITH FACE OF 2nd RISER <br />/ 1x4 GLUED AND NAILED TO STRINGER <br />2x4 DRAFT <br />STOP <br />2x8 SYP DRYWALL STOP <br />MUST NOT TOUCH <br />-2x4 BLOCKING FOR 2x12 <br />•2x4 PT UNDER 2x12 C <br />ROVIDE MOISTURE <br />PROTECTION <br />ACH ALL COMPONENTS <br />STAIR TO CONC. W/J" X <br />TAPCONS @ MAX. 32" O.C. <br />ATTACH ALL COMPONENTS 1x4 GLUED AND <br />OF STAIR TO CONC. W/ k X \E2 <br />NAILED TO STRINGER <br />2 T" TAPCONS @ MAX. 32" O.C. / <br />G-1 <br />SECTION VIEW <br />\ SCALE: 1" = 1'-0" <br />TOP OF <br />STRINGER <br />STRINGERS G <br />R <br />2x4 BLOCKING FOR 2x12 SIMPSON A35 <br />2x4 PT UNDER 2x12 OR LSC EACH <br />2x4 SYP BLOCKING <br />FOR STRAP <br />2x4 PT NOTCHED INTO STRINGER (SIMPSON MTS12 w/ <br />(14) 10d x 1 1/2" NAILS) <br />AND NAILED TO FLOOR WITH GLUE / <br />AT STRINGER CONTACT POINTS \ <br />SECTION VIEW "D" SECTION VIEW "E" <br />SCALE: 1" = 1'-0" SCALE: 1" = 1'-0" <br />FILLER STRIPS ADDED <br />GLUED & SCREWED TO <br />PLYWOOD DECKING <br />PLYWOOD <br />2x SYP CUT TO FIT <br />BEARS IN WALL <br />2x12 SYP <br />BEARS IN WALL <br />BULLNOSE DETAIL <br />SCALE: 1" = 1'-0" <br />2x4 GLUED <br />AND NAILED <br />SECTION D-D <br />3/4 PLYWOOD <br />ON DECK <br />3/4" RISER CUT TO FIT <br />2x4 SYP BLOCKING <br />MAINTAIN BETWEEN 1/4" <br />FOR STRAP (SIMPSON <br />AND 112" GAP TOP AND <br />MTS12 w/ (14) 10d x 1 <br />x8 SYP GLUED <br />BOTTOM, GLUED AND <br />1/2" NAILS) <br />AND NAILED TO <br />NAILED TO STRINGER <br />FRAMING <br />2x4 DRAFT 2x12 <br />STOP TREAD <br />2x12 TREAD <br />GLUED <br />GLUED AND <br />AND <br />NAILEDi <br />NAILED <br />2x4 PT NOTCHED INTOspa <br />STRINGER AND TAPCO2x8 SYP DRYWALL STOP MUST <br />INTO FLOOR WITH GLUNED NOT TOUCH STRINGERS <br />STRINGER CONTACT 2x4 BLOCK IN KNEEWALL FOR 2x12 NAILING <br />POINTS IX4 GLUED AND NAILED TO STRINGER <br />E FOR DRYWALL SPACING <br />H SECTION VIEW <br />SCALE:" = 1'-0" <br />2x4 PT NOTCHED INTO <br />STRINGER AND TAPCONED <br />INTO FLOOR WITH GLUE -AT <br />STRINGER CONTACT <br />POINTS <br />SCALE: 1" = 1'-0" <br />2x8 SYP DRYWALL STOP MUST <br />NOT TOUCH STRINGERS <br />L, GLUED AND NAILED TO STRINGER <br />FOR DRYWALL SPACING <br />H <br />E SECTION VIEW <br />SCALE: " = 1'-0" <br />NOTE: 2x8 <br />DRYWALL STOP <br />NOT SHOWN <br />FLOOR TRUSS OR <br />GIRDER, FIELD VERIFY <br />STRINGER <br />OPTION: 2X4 CUT ON (2) LAYER" EDGE GOLD <br />BEVEL GLUED AND OSB OR PLYWOOD <br />NAILED TO SUPPORT OR 1"X16" LVL <br />W/ SIMPSON H3 ATTACHED W/ 12d NAILS <br />@ 6" O.C. TOP, BOTTOM <br />AND VERT. <br />SECTION VIEW "G" <br />SCALE: 1" = V-0" <br />F SECTION VIEW <br />SCALE: " = 1'-0" <br />CONN. TO BOTTOM <br />OF NEWEL POST <br />PER CONTRACTOR <br />a <br />PROVIDE SOLID BLOCKING <br />BELOW ALL NEWEL POST <br />FROM JOIST TO JOIST. USE <br />2 X 12 BLOCKS, GLUED AND <br />NAILED TO JOIST. <br />NEWEL POST <br />BLOCKING <br />STAIR CONSTRUCTION DETAILS <br />(IF 11X17 REDUCE SCALE .5) SCALE: AS NOTED <br />SCALE: 1" = 1'-0" <br />rWALL JOINT <br />YWALL TO <br />✓ER JOISTS) <br />STUD NAILED AND <br />)ED TO TOP PLATE <br />CUT INTO RIM BAND, <br />JED AND NAILED TO <br />tRING WALL BELOW <br />(WALLJOINT <br />YWALL TO <br />JER JOISTS) <br />NEWEL POST LET INTO <br />THE BLOCK <br />PROVIDE <br />BLOCKING <br />2X8 BLOCKING <br />FOR NEWEL POST <br />TO ANCHOR TO. <br />(GLUED AND NAILED) <br />TRUSSES <br />H <br />2X STRING R <br />2X B OCKING <br />SIMPSON MTS 2 w/ <br />(14) 10d x 1 1/2" NAILS <br />D OR <br />3 <br />2X BLOC NG <br />RIS R <br />L5� <br />VARIES <br />SECTION VIEW "H" <br />SCALE: 1" = 1'-0" <br />r <br />',fi48, <br />N,XRO <br />INr <br />v CEO <br />•.. ..• <br />i�.. <br />firo4 �POFESS\0�,���\ <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 0th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />co <br />co NLQ `° <br />Q O O � Ol f0 N <br />0 :L—j �� W w <br />-g u- � a a <br />Q 52 aaw�Y <br />z -.0 U) <br />11 m <br />y 2 o m O c <br />W mo��O m��� <br />WaLo <br />0 <br />M W 2ET i W. <br />M <br />N Z U <br />z ° ❑❑❑❑ <br />W <br />Ur 2 <br />87 <br />J C) <br />d N <br />_ M <br />W <br />N z <br />C1 <br />� U <br />_ <br />4--+ <br />� W g <br />o a <br />•0 <br />r U <br />U1 f�- E <br />ZD <br />� � o <br />U 00 <br />eE <br />\ W <br />r <br />s <br />U <br />• <br />Q & <br />S� <br />o <br />co <br />W <br />o <br />Z <br />U_ <br />a E <br />�o <br />a <br />> <br />Z <br />?® <br />V <br />NO <br />Q <br />g0 <br />XU <br />°a <br />Up <br />OU <br />Z <br />O (a <br />°<z <br />�i <br />�az <br />w <br />ao <br />mC, <br />:9' ra <br />N c <br />.. <br />oU <br />° <br />01 <br />Z <br />3 <br />o�° <br />W <br />oF <br />� <br />=_ <br />� <br />N Z <br />S <br />(? F <br />>° <br />IIIIIIIIII� <br />o <br />co <br />m <br />ila <br />a <br />O° 3: <br />0 <br />`N <br />= <br />` <br />> Lo <br />J <br />M <br />14 <br />O <br />^L <br />,W <br />CN <br />.= <br />T <br />> <br />M <br />.-. <br />a <br />o <br />mca <br />W 2 <br />o <br />LO <br />� O <br />Lr) <br />.V � O <br />T <br />NLO <br />= r <br />E <br />Ch N <br />z <br />Z <br />E O N T <br />E <br />m <br />c <br />c <br />d <br />U � Q p <br />JOB <br />NO : 20-0566 <br />SCALE : AS NOTED <br />SHEET NO. <br />ST <br />