Laserfiche WebLink
I I I I �11n Ili,l�rn I <br />n <br />CROSS BRACING DETAIL (TYP.) <br />SCALE: N.T.S. <br />TRUSS NOTES: <br />CONV. FRAMED RIDGE <br />1. WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSUTPl-2014 MAY BE NAILED <br />(TRUSS PLATE INSTITUTE) NOTE THAT THE COMBINED WIND AREA IS GREATER w/ MIN. (4) 12d WHEN <br />BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE IT LANDS NEXT TO <br />INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST PRE-ENG. TRUSS <br />COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES <br />OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD <br />SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & <br />SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION <br />OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED <br />ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER <br />A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. <br />2. ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS <br />LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTER ALL LATERAL BRACING <br />SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20'-0" <br />O.C. MAXIMUM. <br />3. ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED w/ (3) 12d <br />NAILS AT EACH TRUSS INTERSECTION. CB <br />4. ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS <br />DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT <br />ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. Dg <br />5. PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS <br />DEPTH EXCEEDS STANDARD HEEL HEIGHT SEE TYP TRUSS BLOCKING DETAILS <br />TYP. HAND FRAMING ABOVE TRUSS <br />2X4 STUDS & PLATES AT 2'-0" O.C. <br />EACH DIRECTION TYP. U.N.O. <br />2x8 BLOCKING NAILED @ <br />- EACH SIDE w/ (3) 12d NAILS <br />WHEN REQUIRED w/ (2) <br />SIMPSON HTS20 w/ (24) 10d x <br />1 1/2" NAILS EACH <br />TB <br />PRE-ENG. TRUSS <br />2X4 DIAGONAL AT 8'-0" O.C. 2X4 BLOCKING <br />MAX &EACH END ALTERNATE BETWEEN EA. TRUSS CONT. ROOF SHEATHING AT TRUSS TOP — <br />1 A CHORD AT ALL HAND FRAMED AREAS TYP. <br />DIRECTION TYP. <br />_--z—WOOD TRUSS <br />A <br />TYP. WOOD TRUSS BLOCKING DETAIL <br />SCALE: N.T.S. <br />PORCH SLAB SEE <br />FOUNDATION PLAN <br />4" <br />EXTEND <br />SLAB 1 1/2" <br />(2) #5's CONT. T&B w/ <br />#3 STIRRUPS AT 4'-0" <br />WHEN DEPTH <br />EXCEEDS 30" <br />GRADE <br />CV <br />PORCH SILL 15 <br />SCALE: N.T.S. <br />DIAGONAL <br />AT 8'-0" <br />MAX <br />WOOD <br />TRUSS <br />VERTICAL SCAB 2 x 6 <br />#2 SPF 48" O.C. W/ (4) <br />10d TOP & BOTTOM <br />OR SIMPSON H2.5A w/ <br />(10) 8d NAILS <br />COLLAR TIE <br />EVERY 3rd <br />RAFTER <br />2X4 SPF 2 (2) #7X 3-1/2" <br />WOOD SCREW EACH <br />TRUSS OR SIMPSON <br />H2.5A w/ (10) 8d NAILS <br />AT 48" O.C. <br />BEVEL CUTS <br />(OPTIONAL) <br />2x8 #2 SPF RIDGE BEAM <br />k k 2x6 RAFTERS FOR SPANS 4FT TO 8FT <br />2X4 RAFTERS FOR SPANS LESS THAN <br />4FT @ 2'-0"O.C. MAX. w/ (3) 10d <br />COMMON TOENAILS TO BEAM <br />2X4 CONT. AT—/ CONC. MASONRY <br />T & B CHORD STEEL OR WOOD <br />BEARING SUPPORT <br />SEE ROOF <br />PLAN 7 SHEATHING <br />2X4 BLOCKING <br />BETWEEN TRUSSES <br />SECT. A -A <br />G.T. <br />ADD 2X4 ALONGSIDE <br />TOP CHORD WHEN REQ'D <br />TO PREVENT PLYWOOD <br />SPAN FROM EXCEEDING <br />MAX 24" SPAN (EITHER <br />SIDE OR BOTH IF REQ'D) <br />PROVIDE 2X4 MIN. BLOCKING AT <br />CL OF HIP/RIDGE, TYP.BETWEEN <br />TRUSSES W/ (2) 12D NAILS EACH <br />END TO TRUSS TOP CHORD <br />TYP. <br />�A TRUSS <br />SSES <br />(2) 12D NAILS <br />AT 12" O.C. MAX <br />HIP/RIDGE BLOCKING DETAIL r2 <br />SCALE: N.T.S. <br />z <br />0 <br />Q <br />w <br />J <br />w <br />w <br />w <br />U) <br />HIP <br />G.T <br />WOOD OR MASONRY ABOVE <br />MASONRY PIER SEE FLOOR PLAN <br />WOOD POST. SEE FLR <br />PLAN FOR SIZE & BASE <br />CONNECTION <br />PORCH SLAB SEE <br />FOUNDATION PLAN <br />V-4" <br />SEE <br />PLAN <br />EXTEND <br />SLAB 1 1/2" <br />(2) #5's CONT. T&B w/ <br />#3 STIRRUPS AT 4'-0" <br />WHEN DEPTH <br />EXCEEDS 30" <br />K_aRADE <br />CV ZC <br />T C <br />ENTRY PORCH SILL 14 <br />SCALE: N.T.S. <br />FOR COLUMN INFO <br />WOOD OR MASONRY <br />INTEGRATE MASONRY <br />ABOVE MASONRY <br />KNEEWALL INTO CMU BASE OR <br />PIER SEE FLOOR <br />MAIN HOUSE PER ELEVATION IF <br />PLAN FOR COLUMN <br />REQUIRED <br />INFO <br />MASONRY KNEE WALL MAX 3 <br />COURSES w/ TOP K.O. COURSE <br />CMU BASE W/ (1) #5 <br />W/ (1) #5 CONT. FILLED CELL <br />VERTICAL EACH <br />REQ'D @ MID SPAN MAX 6'-8" <br />CORNER FILLED <br />MAX 3 <br />SOLID. SEE ELEV. <br />COURSE FOR BASE SIZE <br />(3) #5's EA. WAY— <br />v <br />TOP COURSE TO <br />BE CHAIR BLOCKS. <br />ENTIRE BASE TO <br />BE FILLED SOLID <br />SEE ELEV. FOR <br />BLK HGT. <br />I I <br />1 I #5 REBAR CONT <br />@ SLAB LEVEL <br />I I EXTEND SLAB <br />1 I 1 1/2" BEYOND <br />BLOCK FACE <br />• — • o0 <br />EXTEND <br />8" SLAB 1 1/2" <br />SLAB PORCH SLAB SEE <br />LEVEL FOUNDATION PLAN <br />(2) #5's CONT. T&B w/ iv z <br />CONTRACTOR TO INSTALL SEE CUT • <br />MIN 3" x 3" WEEP HOLE SECTION FOR #3 STIRRUPS AT 4'-0" T <br />MORE INFO WHEN DEPTH <br />ALONG w/ PITCHING SLAB <br />EXCEEDS 30" 1'-4" <br />TO DRAIN WATER <br />KNEEWALL OPT. (ELEV TO INDICATE) MASONRY COLUMN <br />ENTRY PORCH SILL rl6 <br />SCALE: N.T.S. <br />f r L <br />I II <br />t <br />I II <br />I I <br />I <br />I <br />I <br />I <br />I <br />I P <br />I <br />SIMPSON LSTA18 SEE PLAN <br />A -A ALTERNATE BLOCKING w/ (12) 10d NAILS — — — — — — SIMPSON HUC410 w/ (14) r— — — — — — — -I ( FOR CANT. <br />CENTERED AT 16d INTO HEADER & (6) <br />DETAIL INTERIOR BEARING SPLIT TO TIE I <br />@ BEAMS TOGETHER I I 10d INTO BEAM - SEE <br />3 ROOF PLAN FOR MORE I I I I I <br />I I <br />I INFO <br />SCALE: N.T.S. I I I I I <br />PROVIDE BLOCKING AT ALL TRUSS BEARING <br />SUPPORT WHERE TRUSS DEPTH EXCEEDS <br />STANDARD HEEL HEIGHT <br />SEE FLOOR PLAN V SEE PLAN FOR <br />FOR BRG. OR REQ'D STAIR INFO. <br />NON-BRG. WALL IF CONCRETE STAIRS <br />FORMED & POURED <br />W/ (1) #5 EACH STEP <br />,2 <br />\ • w <br />4" Z U <br />¢I - <br />PORCH SLAB SEE <br />FOUNDATION PLAN <br />(2) #5's CONT. T&B <br />W/ #3 STIRRUPS AT <br />4'-0" WHEN DEPTH <br />EXCEEDS 30" <br />. <br />a <br />w <br />Uj <br />U)2 <br />N <br />z <br />LOWER OR <br />N z <br />T <br />GARAGE SLAB <br />1'-4" SEE PLAN <br />LARGE STEP DOWN 17 <br />SCALE: N.T.S. <br />SEE FLOOR PLAN FOR <br />COLUMN SIZE & BASE I I I —7/16" OSB FLITCH PLATE <br />SEE FLOOR PLAN I CONNECTION INFO I I REQ'D ONLY WHEN <br />FOR COLUMN SIZE — —Ij <br />—I INDICATED ON BM. <br />& ADDITIONAL INFO. L� — — — — — — — — — — SCHEDULE/PLAN <br />7/16" OSB FLITCH PLATE SEE FLOOR PLAN FOR <br />REQ'D ONLY WHEN COLUMN SIZE & BASE <br />OPTION A SC EDULDE/PLANM OPTION B CONNECTION INFO OPTION C <br />EXTERIOR SHEATHING COMMON BM. TO POST ATTACHMENT A <br />ATTACHED PER <br />SEE ROOF PLAN <br />NAILING SCHEDULE <br />2x4 STUDS w/ SIMPSON FOR BEAM SIZE & SCALE: N.T.S. <br />SP1 w/ (10) 10d NAILS CONNECTION INFO. BM. SPLICE OVER <br />AT BASE SEE J/S6 FOR CENTER OF POST <br />MORE INFO. A A <br />SEE PLAN FOR <br />TOP OF_qEAM <br />2x4 BASE PLATE W/ o 0 o <br />SIMPSON LSTA30 w/ <br />(22) 10d NAILS OR <br />SIMPSON MTS12 w/ <br />- (14) 10d x 1 1/2" NAILS SIMPSON (2) HTS20 w/ (14) <br />TO FLOOR GIRDER 10d NAILS TYP. U.N.O. SEE PLAN FOR <br />BELOW @ 16" O.C. CANT. IF <br />SEE FLOOR PLAN FOR INDICATED <br />COLUMN SIZE & <br />ADDITIONAL INFO. <br />(WOOD COLUMN SHOWN) <br />16" FLOOR SYSTEM FLOOR GIRDER MIDDLE <br />SEE PLAN FOR SEE PLAN FOR <br />DIRECTION CONNECTION <br />CORNER SEE FOUNDATION <br />SECTION @ FLOOR PLAN FOR MORE INFO <br />5 X/ <br />CONNECTION 22 COMMON BM. ATTACHMENT 18 <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />WOOD WALL <br />OR TRUSS. <br />SEE PLAN <br />STRUCTURAL SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />VARIES W/ <br />ROOF SLOPE <br />2X4 CONT. W/ (2) <br />16d COMMONS <br />NAILS EACH <br />STUD TYP. T&B <br />TRUSS OR <br />ROOF SYSTEM <br />SHEAR TRANSFER <br />EXTERIOR. WALLr7 <br />SCALE: N.T.S. <br />2x4 #2 SYP NAILER. NA <br />TO STUDS w/ (3) 16d @ <br />EACH STUD - TOENAIL <br />EACH TRUSS TO <br />NAILER w/ (3) 10d <br />IF 2x DOUBLE LEDGER, <br />ATTACH FIRST PLY <br />w/ (4) 16d NAILS TO EA. <br />END OF TRUSS THEN <br />ATTACH SECOND PLY w/ <br />(3) ROWS OF 16d NAILS <br />AT 24" O.C. <br />ROOF AND EXTERIOR SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />SEE 2ND FLOOR WALL SECTION <br />FOR ADDITIONAL INFORMATION <br />VERIFY FLOOR JOIST W/ RIM <br />BOARD OR FLOOR GABLE W/ <br />FRAMING PLAN <br />SIMPSON LUS26 w/ (8) 10d H <br />NAILS OR IF 2 PLY TRUSS SEE FLOOR FRAMING PLAN <br />SIMPSON LUS26-2 w/ (8) 16d AND J/S6 FOR MORE INFO. <br />NAILS TO LEDGER VERIFY WITH PLAN FOR <br />2X8 #2 SYP CONT. LEDGER W/ LOCATION AND DIRECTION <br />(4) 16d NAILS ATTACH NAILS (IF PARALLE SEE 2/D2 FOR <br />INTO END OF EACH FLOOR BLOCKING INFO) <br />TRUSS, 24" O.C. MAX. (AT EACH <br />SIDE OF G.T. INSTALL (4) NAILS MASONRY WALL <br />EACH SIDE) (TYPICAL) <br />SECTION AT LOW ROOF 9 <br />SCALE: 1/2" = V-0" <br />COMMON TRUSS <br />W/ INTERIOR BRG. <br />SEE PLAN FOR <br />CONNECTIONS <br />V INFO. <br />--TRUSS/ <br />d�fO_P WALL <br />EE PLAN <br />Y2" CDX PLYWOOD OR %6" O.S.B. F MIN. (2) 2x8 #2 SYP <br />SHEATHING REQ'D FROM BOTTOM <br />OF WALL TO ROOF SHEATHING HEADER. SEE Q/S4 FOR <br />REQ'D CONNECTIONS <br />ABOVE W/ 8d NAILS @ 4" O.C. IN <br />FIELD, EDGES & BOUNDARIES--------� <br />2x4 #2 SPF STUDS @ <br />12" O.C. W/ USP SPT22 <br />— @ BASE & SPT24 @ <br />TOP <br />2x4 #2 SYP P.T. PLATE W/ <br />EPDXY ANCHOR OR <br />J-BOLT OR Y2" TITEN HD <br />SEE PLAN MAX. 2 ANCHOR @ 24" O.C. W/ <br />24" STEPS MIN. 6" EMBEDMENT <br />ay <br />SEE PLAN FOR OPT. - ° -- -- ° <br />STAIR INFO. IF <br />CONCRETE STAIRSI <br />° d ° <br />FORMED & POURED a MAIN HOUSE <br />W/ (1) #5 EACH STEP d SLAB <br />d b d i <br />(2) #5's CONT. T&B <br />A w/ #3 STIRRUPS AT <br />4'-0" WHEN DEPTH <br />a <br />d d <br />-- ° - -- d EXCEEDS 30" <br />d A d d. d. d 9 E <br />GARAGE OR r a <br />i e g <br />LOWER SLAB <br />SEE PLAN ° <br />1'4' <br />SECTION 0 GARAGE MONO 2� <br />SCALE: N.T.S. <br />QV. <br />C <br />0 <br />a)U a <br />W <br />� <br />o <br />H C LA_ a <br />C13® <br />z 3 rc <br />� <br />N <br />T. <br />fn <br />..Ld <br />{1i <br />To the best of the Engineers knowledge, information and belief, <br />the structural <br />plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineers signature and seal is only for <br />the structural <br />engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />N <br />W O* EE <br />4 0 8 <br />N 0 <br />V <br />0'. <br />Q) N <br />0 -W 2 <br />e) (n r r <br />J` <br />H drNiv <br />4 C J LL W <br />J U_a <br />0 W <br />— o a Y <br />Z m E d u> <br />A 0 o <br />' C'4 0 <br />W�2pjO' m <br />un0LOMatJ <br />� <br />N r <br />O V U U <br />Z <br />W ❑cn <br />❑ <br />Z N (7 <br />oLj; <br />z o � <br />Q Q <br />U) <br />�N v <br />� w <br />C_ <br />Q) O <br />w a <br />ul C_ <br />�rz <br />U <br />W J <br />E <br />C <br />Q 0 <br />�Q <br />N <br />o <br />J< <br />w <br />M <br />M <br />� C <br />sZ^ <br />o <br />Z <br />Z <br />f <br />U_ <br />cowz <br />ry <br /><o <br />C:)- O <br />E U <br />Z <br />oa <br />�o <br />o E <br />CO rd <br />a` <br />OQ <br />a z <br />Z <br />Qzo <br />z <br />Qo <br />ox <br />m� <br />Z° <br />Z <br />m <br />maw <br />o� <br />�' <br />go <br />W�� <br />aw <br />m <br />o <br />as <br />;o <br />d <br />M <br />C) <br />g <br />�O <br />6 <br />C <br />qt <br />CU <br />cD <br />/� <br />L <br />(10 <br />T <br />00 <br />LO <br />O = <br />0 <br />CM <br />L.n <br />LO <br />MO N <br />I— <br />r- <br />Q CD IUD <br />d) <br />C7 ` <br />LO <br />o <br />Z <br />M <br />7 p Li <br />Z <br />T <br />c <br />a <br />U _j Q 0 <br />-� <br />JOB <br />NO: 23-06114 <br />SCALE: AS NOTED <br />SHEET NO. <br />D 1 <br />