My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36403 Well Hill Way
Zephyrhills
>
Building Department
>
Building Plans
>
36403 Well Hill Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 4:14:25 PM
Creation date
2/25/2025 9:40:07 AM
Metadata
Fields
Template:
Building Plans
Street #
36403
Location
Well Hill Way
Contractor
Lennar Homes LLC
Building Plans - Permit #
6702
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
_ - Im 11 i- - I I ILI I I I <br />I <br />I <br />I <br />------------------------------- <br />(2) SIMPSON MSTAM36 STRAPS w/ (7) 10d <br />NAILS & (4) 1/4" x 2 1/4" TITENS CENTERED <br />ON FLOOR SYSTEM TO MASONRY WALL <br />BELOW. IF WOOD WALL IS BELOW USE (2) <br />SIMPSON MSTA36 STRAPS w/ (26) 10d <br />NAILS (G.C. TO INSURE SOLID BLOCKING - <br />IS INSTALLED). <br />EXT. SHEATHING <br />FLUSH W/ TOP <br />SEE FOR 2 OF MASONRY & 8d <br />BLOCKING NAILS T/B FLANGE <br />DETAILS 2x STUDS <br />0 <br />FLOOR SYSTEM <br />SEE PLAN <br />G.C. VERIFY INTERIOR <br />1/2" GYP. BOARD OR <br />EXTERIOR STRUCTURAL <br />SHEATHING (MIN. 7/16") <br />VERIFY W/ PLAN <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />SEE SS FOR RETROFIT <br />CONNECTION IF MSTAM36 <br />SECTION CORNER CAN NOT BE INSTALLED <br />FRAMING ATTACHMENT <br />N.T.S. <br />SEE Q/S4 FOR SIMPSON SP4 w/ (6) 10d x 1 1/2" (USE SP6 FOR <br />AO SIMPSON SP2 w/ (12) 10d NAILS <br />JAMB STUD 2x6 WALL, USE SP8 FOR 2x8 WALL)@ 24" O.C. <br />REQ'D TYP <br />BO SIMPSON LSTA24 w/(18) 10d NAILS <br />of <br />T P. <br />2 - 2 x 4 SPF <br />@)SIMPSON CS16 w/ MIN. 12" END <br />A <br />TOP PLATES <br />LENGTH O N STUDS W/ 11 10d <br />A. <br />NAILS TO STUDS ABOVE & 11 10d <br />( ) <br />NAILS TO STUDS BELOW. <br />C <br />2 x 4 #2 SPF STUDS <br />AT 16" O.C. U.N.O. <br />OD SIMPSON SP1 w/ (10) 10d NAILS <br />2 2x HEADER <br />G <br />SEE PLAN <br />h <br />OE 5/8" A.B. @ 24" O.C. AND 6" FROM <br />EACH END W/ 7" EMBEDMENT. IF <br />N LOCATION, MIN 7" <br />AT STEP DOWN OC <br />2 x SPF <br />EMBEDMENT PAST STEP. <br />BASE PLATE <br />PRE-ENGINEERED SIMPSON SP4 w/ (6) 10d x 1 1/2" (USE <br />F <br />O <br />C <br />B H <br />O <br />C <br />OR SYSTEM SP6 FOR 2x6 WALL, USE SP8 FOR 2x8 <br />FLOOR <br />l <br />EWALL OR <br />BEAM WALL) AT EACH STUD AT HEADER / <br />JAMB CONDITION OR IF BUILT-UP <br />(2) - 2 x 4 SPF <br />STUDS ARE w/IN WALL SYSTEM A.B. TO <br />TOP PLATES <br />BE SPACED W/IN 6" FROM OPENINGS <br />AND MULTIPLE STUD PACKS <br />g <br />I <br />O INTERIOR HEADER <br />2 x 4 #2 SPF STUDS <br />1 2x SILL PLATE W/ (2) 12dTOENAILS. <br />( ) <br />I. <br />AT 16 O.C. U.N.O. <br />(2) 2x HEADER <br />G <br />EXTERIOR HEADERS <br />E <br />F <br />I ( <br />TYP <br />PLAN <br />(1) 2x SILL PLATE W/ (2) 12d TOENAILS. <br />l <br />l <br />FSEE <br />F <br />2 x 4 P.T. <br />OPENING LARGER THAN 4 ft (2) 2x SILL PLATE <br />D <br />BASE PLATE <br />W/ SIMPSON LS30 w/ (6) 10d x 1 1/2" EACH SIDE <br />1 <br />6 <br />1 SEE FOUND. PLAN FOR FTG. REQ. <br />HO STUDS UNDER 2nd FLOOR HEADER ARE <br />NOT REQ'D TO HAVE CONNECTIONS. <br />ATTACH STUDS w/ (3) 12d TOENAILS T&B <br />2 STORY INT. BEARING WALL <br />PROVIDE EXTERIOR SHEATHING <br />AND EXTERIOR <br />ATTACHED PER NAILING SCHEDULE <br />rj <br />FOR EXTERIOR 2 STORY WALLS ONLY. <br />SHEATHING CAN STOP ONCE UNDER <br />SCALE: N.T.S. <br />LOWER ROOF. <br />SEE 8/D-2 FOR ALT. CONDITION. DETAIL TO BE <br />FOLLOWED IF DOWN SET OR BOX HEADER IS USED <br />OTHERWISE DETAIL CAN BE IGNORED <br />SIMPSON LSTA30 w/ (22) 10d <br />SIMPSON SP4 w/ (6) 10d x 1 1/2" (USE SP6 FOR <br />NAILS BENT OVER TOP PLATE <br />2x6 WALL, USE SP8 FOR 2x8 WALL) @ 24" O.C. <br />THEN DOWN THE FACE OF <br />HEADER/ STUDS <br />(2) 2X SPF TOP PLATE <br />2x CRIPPLES @ 16" O.C. <br />(2) 2x HEADER SEE PLAN <br />W/ (2) 12d TOENAILS T/B <br />INTERIOR HEADER <br />(1) 2x SILL PLATE W/ (2) 12dTOENAILS. <br />(2) 10d TOENAILS AT EACH <br />EXTERIOR HEADERS <br />END OF SILL OPENING <br />(MAX.X. <br />(1) 2x SILL PLATE W/ (2) 12d TOENAILS. OPENING <br />WIDTH 4 FEET). OPENING -� <br />LARGER THAN 4 ft (2) 2x SILL PLATE W/ SIMPSON <br />IS GREATER THAN 4 FEET <br />LS30 w/ (6) 10d x 1 1/2" EACH SIDE <br />BUT NOT EXCEEDING 6 FEET, <br />A SIMPSON LS30 w/ (6) 10d x 1 <br />MIN (3) 2x #2 SPF STUDS @ END <br />1/2" IS TO BE INSTALLED AT <br />OF HEADER SEE Q/S4 FOR <br />EACH END <br />REQ'D JAMB INFO <br />2x CRIPPLE AT EACH <br />SIMPSON LSTA30 w/ (22) 10d NAILS <br />END OF OPENING <br />CENTERED <br />NAILED TO STUD PACK j <br />FLOOR DECK <br />W/ 10d NAILS @ 8"o.c. <br />FLOOR TRUSS/ I -JOIST SEE PLAN <br />SEE PLAN FOR BEAM <br />SIZE & CONNECTIONS <br />HEADER CONN. <br />@ 2nd FLOOR <br />W/ HIGH BM <br />r9 <br />SCALE: N.T.S. <br />(2)- 12d <br />TOENAILS 2x4 <br />TO TRUSS TOP_ <br />GABLE END FLOOR <br />TRUSS SEE R/S6 FOR <br />CONNECTION INFO TO <br />MASONRY WALL <br />DA BELOW AND ALT. <br />BLOCKING INFO O <br />A <br />1. APPLY SUB <br />FLOOR <br />ADHESIVE TO <br />2x4 CONTACT <br />SURFACE <br />I <br />U 2x4 #2 BLOCKING <br />NOTE: VERIFY WITH FLOOR <br />B 2x4 SIDE BRACE <br />FRAMING PLAN FOR I -JOIST <br />AT 48" O.C. <br />OR FLOOR TRUSS FOR <br />BETWEEN JOISTS <br />CORRECT BLOCKING <br />w/ (3) 12d EA. END <br />REQUIREMENTS <br />TO HORIZ. <br />BLOCKING <br />1-1/8" RIM BOARD <br />JOIST SEE PLAN <br />8d NAILS @ 3" O.C. <br />WALL SHEATHING <br />(2) 12d TOE NAILS TOP <br />TO RIM BOARD <br />& BOTT. CHORD <br />AJS BLOCKING PANEL @ 24" <br />O.C. (MAX) AND @ EACH <br />GABLE END RIM JOIST <br />END OF WALL UNDER <br />SEE R/S6 FOR <br />CORNERS <br />CONNECTION INFO TO <br />(2) - 10d TOE NAILS <br />MASONRY WALL <br />EACH SIDE <br />BLOCKING <br />DETAIL 2 <br />SCALE: N.T.S. <br />SEE SS FOR RETROFIT SEE 8/D-2 FOR ALT. CONDITION. DETAIL TO BE <br />CONNECTION IF MSTAM36 FOLLOWED IF DOWN SET <br />OR BOX HEADER IS USED <br />CAN NOT BE INSTALLED OTHERWISE DETAIL CAN BE IGNORED <br />SIMPSON SP4 w/ (6) 10d x 1 1/2" (USE SP6 FOR <br />(1) SIMPSON LSTA30 w/ (22) 10d <br />2x6 WALL, USE SP8 FOR 2x8 WALL) @ 24" O.C. <br />NAILS BENT OVER TOP PLATE <br />(2) - 2X SPF TOP PLATE <br />THEN DOWN THE FACE OF <br />HEADER/ STUDS <br />(2) 2x HEADER SEE PLAN <br />INTERIOR HEADER <br />(1) 2x SILL PLATE W/ (2) 12dTOENAILS. <br />MIN (3) 2x #2 SPF STUDS @ <br />EXTERIOR HEADERS <br />END OF HEADER SEE Q/S4 FOR ,, <br />(1) 2x SILL PLATE W/ (2) 12d TOENAILS. <br />REQ'D JAMB INFO h <br />OPENING LARGER THAN 4 ft (2) 2x <br />SILL PLATE w/ SIMPSON LS30 w/ (6) <br />2x CRIPPLES @ 16" O.C. <br />10d x 1 1/2" EACH SIDE <br />W/ (2) 12d TOENAILS T/B <br />(2) 10d TOENAILS AT EACH END OF <br />SILL (MAX. OPENING WIDTH 4 FEET). <br />IF OPENING IS GREATER THAN 4, <br />2X CRIPPLE AT EACH END OF <br />FEET BUT NOT EXCEEDING 6 FEET, <br />OPENING NAILED TO STUD <br />A SIMPSON LS30 w/ (6) 10d x 1 1/2" IS <br />PACK W/ 10d NAILS @ 8"O.C. <br />TO BE INSTALLED AT EACH END. <br />PLYWOOD ATTACHED PER <br />TYPICAL BLOCK WALL ---------_NAILING <br />SCHEDULE <br />FLOOR TRUSS/ I -JOIST SEE PLAN <br />SIMPSON MSTAM36 W/ (7) <br />TIE BEAM <br />10d NAILS & (4) 1/4"x2 1/4" <br />TAPCONS <br />PROVIDE BLOCKING <br />BELOW JAMBS <br />HEADER CONN. @ 2nd FLOOR <br />SYSTEM 42 SCALE: N.T.S. <br />SEE SS FOR RETROFIT <br />SEE 8/D-2 FOR ALT. CONDITION. DETAIL TO BE <br />CONNECTION IF MSTAM36 FOLLOWED IF DOWN SET OR BOX HEADER IS USED <br />CAN NOT BE INSTALLED <br />OTHERWISE DETAIL CAN BE IGNORED <br />(2) SIMPSON LSTA30 w/ (22) <br />SIMPSON SP4 w/ (6) 10d x 1 1/2" (USE SP6 FOR <br />10d NAILS BENT OVER TOP <br />2x6 WALL, USE SP8 FOR 2x8 WALL) @ 24" O.C. <br />PLATE THEN DOWN THE <br />(2) 2x HEADER SEE PLAN <br />FACE OF HEADER/STUDS <br />2x CRIPPLES @ 16" O.C. <br />W/ (2) 12d TOENAILS T/B <br />INTERIOR HEADER <br />MIN (3) 2x #2 SPF STUDS <br />(1) 2x SILL PLATE W/ (2) 12dTOENAILS. <br />@ END OF HEADER. SEE <br />EXTERIOR HEADERS <br />Q/S4 FOR REQ'D JAMB <br />(1) 2x SILL PLATE W/ (2) 12d TOENAILS. <br />INFO. <br />OPENING LARGER THAN 4 ft (2) 2x <br />SILL PLATE w/ SIMPSON LS30 w/ (6) <br />2x CRIPPLE AT EACH END OF <br />10d x 1 1/2" EACH SIDE <br />OPENING NAILED TO STUD <br />PACK W/ 10d NAILS <br />(2) 10d TOENAILS AT EACH END OF <br />SILL (MAX. OPENING WIDTH 4 FEET). <br />TYPICAL BLOCK WALL <br />IF OPENING IS GREATER THAN 4, <br />FEET BUT NOT EXCEEDING 6 FEET, <br />A SIMPSON LS30 w/ (6) 10d x 1 1/2" IS <br />SIMPSON (2) MSTAM36 w/ (7) <br />TO BE INSTALLED AT EACH END. <br />10d NAILS & (4) 1 /4"x2 1/4" <br />; <br />TAPCONS <br />FLOOR DECK <br />PROVIDE BLOCKING <br />FLOOR TRUSS/ I -JOIST SEE PLAN <br />BELOW JAMBS TIE BEAM <br />2X CONT. RIBBON <br />HEADER <br />CONN. @ 2nd <br />FLOOR <br />[DOUBLE STRAP] rj� <br />SYSTEM 42 SCALE: N.T.S. <br />SEE SS FOR RETROFIT <br />CONNECTION IF MSTAM36 <br />CAN NOT BE INSTALLED <br />(3) 2x # SPF <br />STUDS w/ 10d @ <br />8" O.C. EACH SIC <br />U.N.O. ON PLAN <br />2X CONT. RIBBON - <br />TYPICAL BLOCK <br />WALL <br />(2) SIMPSON MSTAM36 w/ <br />(7) 10d NAILS & (4) 1/4"x2 <br />1/4" TITENS <br />GIRDER/COL. CONN. <br />)R 2 PLY GIRDER <br />IUSS. SEE PLAN FOR <br />)NNECTION. <br />=E PLAN FOR CONN. <br />- 2x SPF TOP PLATE <br />FLOOR DECK <br />FLOOR TRUSS/ <br />I -JOIST SEE PLAN <br />TIE BEAM <br />PROVIDE BLOCKING <br />BELOW JAMBS <br />2nd FLOOR <br />SCALE: N.T.S. <br />EE PLAN FOR CONN. <br />SEE PLAN FOR <br />COL. SIZE <br />NAILING AREA (TYP.) <br />(2) SIMPSON MST37 <br />STRAPS w/ (42) 16d NAILS <br />FLOOR SYSTEM OR <br />2-STY. FRAMING <br />BAND JOIST & BLKG. <br />OR LVL GIRDER <br />r <br />(BLOCK SOLID) <br />SEE PLAN FOR <br />COL. SIZE <br />SIMPSON HTT4 w/ (18) <br />16d NAILS & 5/8" <br />ANCHOR BOLT w/ <br />.. <br />MIN. 6" EMBEDMENT <br />e IPa ° <br />• I, a <br />L, <br />SEE FOUNDATION PLAN <br />FOR FTG. REQ. <br />2 STORY COL. a0 GIRDER r7 <br />SCALE: N.T.S. <br />2x4 STUDS <br />PER PLAN <br />3 <br />DOUBLE 2x4 <br />TOP PLATE <br />2 WS 10d @ <br />3"O/ A�rFN <br />O <br />TOP SPLICE <br />MiN A <br />PROVIDE 2x4 ON <br />TOP OF 2x8 TO ° <br />BLOCK OUT TOP <br />PLATE ATTACH <br />W/ (2) 10d NAILS <br />@ 3" O.C. 2x4 BEYOND DOUBLE <br />AGAINST 2x8 2x8 TOP <br />STUDS PLATE <br />2x8 STUDS <br />PER PLAN 2x4 W/ 2 ROWS <br />NOTE: OF 10d NAILS <br />PLATE LENGTHS MUST BE @ 3" O.C. <br />AT LEAST 4'-0" LONG. TYPICAL <br />TOP PLATE SPLICE DETAIL <br />SCALE: N.T.S. <br />(1) SIMPSON LSTA30 w/ (22) <br />10d NAILS BENT OVER TOP <br />SIMPSON SP4 w/ (6) 10d x 1 1/2" <br />PLATE THEN DOWN THE <br />(USE SP6 FOR 2x6 WALL, USE SP8 <br />FACE OF HEADER/STUDS <br />FOR 2x8 WALL) <br />@ 24" O.C. <br />2x CRIPPLES @ 16" O.C. <br />(2) 2x SPF TOP PLATE <br />W/ (2) 12d TOENAILS T/B <br />(2) 2x HEADER SEE PLAN <br />(2) 10d TOENAILS AT EA. <br />INTERIOR HEADER <br />END OF SILL. MAX. <br />(1) 2x SILL PLATE W/ (2) 12d TOENAILS. <br />OPENING WIDTH 4 FEET. <br />EXTERIOR HEADERS <br />IF OPENING IS GREATER , <br />(1) 2x SILL PLATE W/ (2) 12d TOENAILS. <br />THAN 4 FEET BUT NOT <br />OPENING LARGER THAN 4 ft (2) 2x <br />EXCEEDING 6 FEET. <br />SILL PLATE w/ SIMPSON LS30 w/ (6) <br />A SIMPSON LS30 w/ (6) 10d <br />10d x 1 1/2" CLIP EACH SIDE <br />x 1 1/2" CLIP IS TO BE <br />INSTALLED AT EA. END <br />MIN (3) 2x #2 SPF STUDS @ END OF <br />HEADER SEE Q/S4 FOR REQ'D JAMB <br />INFO <br />2x CRIPPLE AT EA. <br />END OF OPENING <br />SIMPSON LSTA30 w/ (11) 10d <br />NAILED TO STUD <br />TO STUDS ABOVE PLATE <br />PACK w/10d NAILS <br />FLOOR DECK <br />@ 8"o.c. <br />FLOOR TRUSS/ I -JOIST SEE PLAN <br />SIMPSON LSTA30 FROM <br />WINDOW JAMB TO <br />FLOOR TRUSS/ SOLID <br />BLOCKING BELOW. SEE 8/D-2 <br />FOR ALT. CONDITION. DETAIL TO BE <br />FOLLOWED IF <br />DOWN SET OR BOX HEADER IS USED <br />OTHERWISE DETAIL CAN BE IGNORED <br />HEADER CONN. <br />@ 2nd FLOOR 4 <br />SCALE: N.T.S. <br />2x6 / 2x8 CRIPPLES @ 16" O.C. <br />NOTCHED AT HEADER LOCATION <br />SEE INFO BELOW ON CONNECTION <br />OF CRIPPLES IF LONGER THAN 8" <br />TALL. (CONTRACTOR MAY USE RTT <br />CLIPS) NAIL BACK LEG OF CIPPLE TO <br />HEADER w/ (2) 12 TOENAILS <br />HEADER FLUSH TO OUTSIDE <br />DOUBLE 2x6 OR 2x8 TOP <br />PLATE SEE PLAN <br />12d NAILS AT 6" <br />O.C. TYP T & B \ <br />SYP U.N.O. <br />2xCONT.T&B --' <br />(2) 2x8 OR (2) 2x6 TOP <br />PLATE SEE PLAN <br />(2) 2x HEADER TO SIT <br />FLUSH w/ THE OUTSIDE <br />SEE PLAN FOR SIZE <br />0/1 V��'zx_ 2x6 / 2x8 WALL BEYOND SEE <br />FLOOR PLAN FOR HEADER <br />i <br />I I CONNECTION <br />— SEE STANDARD HEADER <br />CONNECTION DETAILS FOR <br />MORE INFORMATION <br />SIMPSON SP6 w/ (6) 10d x <br />1 1/2" (USE SP8 FOR 2x8 <br />WALL) @ 24" O.C. <br />I <br />BOX HEADER <br />(2) SIMPSON LSTJ2 w/ (10) 10d (2) 2x TOP PLATE <br />NAILS WRAPPED UP AND 2x CRIPPLES @ 16" O.C. w/ <br />OVER TOP PLATE SIMPSON SP2 w/ (12) 10d NAILS AT <br />TOP AND SIMPSON SP1 w/ (10) 10d <br />- <br />- - \ NAILS AT BASE <br />r1 J *PROVIDE (2) CRIPPLES BELOW <br />—4—L <br />TO ANY GIRDER TRUSS IN THIS <br />SITUATION. CONNECT G.T. TO <br />2x CRIPPLES TO <br />MATCH JACK <br />STUDS w/ (2) SIMPSON HTS20 w/ <br />STUDS BELOW <br />(24) 10d x 1 1/2" NAILS AT TOP AND <br />BOTTOM TO HEADER <br />(IF CRIPPLES ARE LESS THAN 8" <br />LONG NO STRAPS ARE REQ'D) <br />j� <br />ADDITIONAL STRAPS <br />SEE STANDARD HEADER REQUIRED AT TOP PLATE <br />CONNECTION DETAILS FOR TO STUDS TO MATCH <br />MORE INFORMATION HEADER STRAPS <br />(2) SIMPSON LSTA24 w/ (18) 10d NAIL (2) 2x HEADER SEE PLAN <br />MIN (3) 2x #2 SPF STUDS @ END OF HEADER <br />SEE Q/S4 FOR REQ'D JAMB INFO <br />SIMPSON LS30 w/ (6) 10d x 1 1/2" NAILS AT EACH END TYP. <br />*FOR OPENINGS LESS THAN 4'-0" WIDE, SILL MAY BE <br />ATTACHED w/ (2) 16d TOENAILS AT EACH END <br />(2) 2x SILL PLATE <br />2x STUDS @ 16" O.C. <br />ALT. HEADER ANCHOR <br />SCALE: N.T.S. <br />' N <br />0 <br />N <br />7 W <br />ii GCS M <br />�•, C I9 f> CS <br />C'V <br />— m <br />cco r <br />N O c4 <br />N X <br />3= <br />d a- w <br />r -:zc <br />C.7 <br />r r. 3 <br />l <br />e <br />,;aaa+ltllrr/rrr/ <br />T C) <br />,< <br />0 <br />F L. <br />Ff <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />N <br />W �E <br />0 <br />a 8 <br />�8 <br />OCN <br />y <br />J <br />0 <br />vi NMv w <br />Q LI_ <br />W <br />J u- a <br />S W o @ N � <br />W 7 x <br />0��� m w <br />LL Z <br />Z N OU <br />0 <br />W ❑ ❑ <br />V M C> <br />� M <br />N MO <br />� N <br />z o � <br />M <br />� z <br />( o <br />Q) w <br />a-, <br />O w S <br />V) N <br />�N J <br />U) <br />� e— <br />— E <br />S � � <br />U o <br />Q N M <br />o <br />w <br />M <br />Cl*) <br />¢ <br />z <br />U_ <br />ca E <br />zo <br />oo <br />yN <br />Zo <br />Q� <br />Q <br />o- o <br />E V <br />w� <br />Z <br />oa <br />H D <br />g 0 <br />O <br />�ru <br />0`o� <br />Q <br />Z <br />t�9 <br />t <br />woa <br />o <br />wZ <br />w <br />U <br />O <br />Zma <br />} <br />J <br />2 <br />�m< <br />o <br />g <br />W <br />cn <br />T <br />w w <br />a z <br />z <br />N <br />o <br />wa <br />-� <br />s�Q <br />Qo <br />° <br />o O <br />Ln <br />c� <br />co <br />T <br />Cfl <br />Q <br />r `° <br />T <br />U) 3:LO <br />N <br />m <br />LO <br />M <br />Q± <br />04 <br />N <br />Ltd <br />0 N <br />T <br />T <br />E <br />r � M <br />7 LI1 / <br />o <br />Z <br />E T u <br />c <br />il <br />0 _j a o <br />JOB <br />NO: 23-06114 <br />SCALE : AS NOTED <br />SHEET NO. <br />D2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.