DIVISION Tl FINISHES <br />SECTION 0911,E METAL SYSTEMS <br />METAL STUDS <br />A. AT INTERIOR METAL STUD PARTITIONS, UNLESS OTHERWISE SHOWN ON THE DRAWINGS, PROVIDE <br />STANDARD PUNCH STEEL STUDS OF THE SIZES SHOWN ON THE DRAWINGS, EITHER HOT -DIP <br />GALVANIZED OR FACTORY PRE -PAINT: 25 GA. UNLESS SHOWN OTHERWISE ON THE DRAWINGS. 20 <br />GA. AT ALL DOOR OPENINGS. <br />B. ACCESSORIES: PROVIDE ALL ACCESSORIES INCLUDING, BUT NOT NECE55ARILY LIMITED TO, <br />TRACKS, CLIPS, ANCHORS, FASTENING DEVICES, SOUND ATTENUATION PENCIL RODS AND <br />RESILIENT CLIPS, AND OTHER ACCESSORIES REQUIRED FOR A COMPLETE AND PROPER <br />INSTALLATION, AND AS RECOMMENDED BY THE MANUFACTURER OF THE STEEL STUDS USED, <br />C. MEET OR EXCEED MINIMUM REQUIREMENTS OF FEDERAL SPEC. QQ-54098 AND FEDERAL SPEC. <br />QQ-5-115p, CLASS p. <br />METAL TRIM <br />A. FORM FROM GALVANIZE[) STEEL NOT LIGHTER THAN 26 GAUGE, COMPLYING WITH FEDERAL SPEC <br />QQ-5-115, CLASS D. <br />B. CASING BEADS: U.S.G. *200-5. <br />END OF SECTION 0g110 <br />SECTION OW50 GYPSUM WALLBOARD <br />PART 1 GENERAL <br />1.01 GENERAL <br />A. GYPSUM WALLBOARD WORK SHALL CONFORM TO THE GYPSUM ASSOCIATION "RECOMMENDED <br />SPECIFICATIONS FOR THE APPLICATION AND FINISHING OF GYPSUM WALLBOARD." <br />B. EXAMINE SUBSTRATES TO WHICH DRY WALL CONSTRUCTION ATTACHES OR ABUTT5, PRESET HOLLOW METAL <br />FRAMES, CAST-IN-ANCORS, AND STRUCTURAL FRAMING FOR COMPLIANCE WITH REQUIREMENTS FOR <br />INSTALLATION TOLERANCE AND OTHER CONDITIONS AFFECTING PERFORMANCE OF DRY WALL <br />CONSTRUCTION. DO NOT PROCEED WITH INSTALLATION UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN <br />CORRECTED. <br />C. DO NOT TAPE AND FINISH GYPSUM BOARD WHEN THE TEMPERATURE IS BELOW 60 DEGREES FAHRENHEIT. <br />THE TEMPERATURE OF THE ROOMS SHALL BE HELD AT 60 DEGREES FAHRENHEIT FOR 48 HOURS BEFORE <br />TAPING AND FINISHING IS TO BEGIN. MAINTAIN 60 DEGREES FAHRENHEIT DURING AND AFTER INSTALLATION. <br />VENTILATES AS REQUIRED TO REMOVE EXCESS HUMIDITY. <br />1.02 GYPSUM WALLBOARD <br />A. GYPSUM WALLBOARD SHALL BE MANUFACTURED BY U.S. GYPSUM. WALLBOARD IS TO MEET. ASTM C36-84A <br />AND 55-L-30d 1/2 INCHES THICK, 48 INCHES WIDE WITH TAPERED EDGES. <br />B. AT FIRE RATED PARTITIONS INSTALL WALLBOARD TO MEET SEPARATE REQUIREMENTS, USE TYPE 111, GRADE <br />X CLASS I, 5/6 INCHES THICK FIRE RETARDANT WALLBOARD. <br />C. INSTALL GYPSUM BOARD WITH TRUE, EVEN SURFACES AND STRAIGHT, SHARP CORNERS. USE FULL LENGTH <br />BOARDS WHERE POSSIBLE. END JOINTS ON THE SAME SIDE OF A WALL SHALL BE STAGGERED AND JOINTS <br />ON OPPOSITE SIDE SHALL NOT OCCUR OVER THE SAME SUPPORT. DO NOT LOCATE NORMAL END JOINTS AT <br />EDGE OF OPENINGS. FORM JOINTS NEATLY. BUTT BOARDS TOGETHER BUT DO NOT FORCE INTO PLACE. DO <br />NOT BUTT EDGES AGAINST TAPERED EDGES. NO JOINT SHALL HAVE A GAP GREATER THAN 1/4 INCH. <br />D. IN GENERAL, INSTALL GYPSUM BOARD ON CEILING BEFORE WALLS. CONSTRUCT CEILINGS WITH LONG <br />DIMENSION OF GYPSUM BOARD APPLIED AT RIGHT ANGLES TO SUPPORT. <br />E. SCREW GYPSUM BOARD TO FRAMING WITH SCREWS NOT OVER 8 INCHES ON CENTER FASTEN GYPSUM <br />BOARD BEGINNING AT THE CENTER AND WORK TOWARDS OUTER EDGES. HOLD BOARD FIRMLY AGAINST <br />WOOD FRAMING WHILE FASTENING. FASTENERS AT EDGES OF BOARDS SHALL BE 1/2 INCH FROM THE EDGE. <br />F. OPENINGS FOR ELECTRICAL DEVICES, PIPING, GRILLS, AND REGISTERS SHALL BE ACCURATELY LOCATED <br />AND NEATLY MADE TO CLOSELY FIT THE DEVICES AND BE COMPLETELY COVERED BY PLATES AND <br />ESCUTCHEONS. <br />1.03 TRIM PIECES <br />A PROVIDE TRIM ACCESSORIES OF THE SIZES REQUIRED FOR THE WALLBOARD APPLICATION AS <br />MANUFACTURED BY U.S. GYPSUM. PROVIDE DUR-A-BEAD CORNER BEAD AT EXTERNAL CORNERS AND NO. <br />200-A METAL CASING BEAD WHERE WALLBOARD ABUTTS OTHER MATERIALS. <br />1.04 FASTENERS <br />A. PROVIDE SCREWS, NAILS, CLIPS, TIES, AND OTHER FASTENERS AS RECOMMENDED BY THE GYPSUM <br />MANUFACTURER <br />1.05 JOINT TREATMENT SYSTEMS <br />A. SYSTEM SHALL BE PERFORATED TAPE AND CEMENT RECOMMENDED THE GYPSUM MANUFACTURER <br />B. APPLY MATERIALS IN STRICT ACCORDANCE TO MANUFACTURER'S RECOMMENDATIONS. FILL JOINTS WITH <br />JOINT COMPOUND, EMBED PERFORATED TAPE AND APPLY A SKIM COAT OF JOINT COMPOUND OVER TAPE. <br />APPLY TWO ADDITIONAL COATS OF JOINT COMPOUND ALLOWING AT LEAST 24 HOURS BETWEEN EACH COAT. <br />SAND EACH COAT. FINISH SURFACES SHALL BE UNIFORMLY SMOOTH, TRUE AND IN SATISFACTORY CONDITION <br />TO RECEIVE PAINT. <br />END OF SECTION 09250 <br />SECTION OWOO CERAMIC TILE <br />PART 1 GENERAL <br />101 GENERAL <br />A. CERAMIC AND TYPES ARE INDICATED ON THE DRAWINGS AND ARE FROM A SINGLE MANUFACTURER OTHER <br />MANUFACTURERS WILL NOT BE CONSIDERED. <br />B. DELIVER MATERIALS IN ORIGINAL CONTAINERS WITH SEALS UNBROKEN AND LABELS INTACT UNTIL TIME OF <br />USES. ENGAGE AN EXPERIENCED INSTALLER WHO HAS SUCCESSFULLY COMPLETED TILE INSTALLATIONS <br />SIMILAR IN MATERIAL, DESIGN, AND EXTENT TO THAT INDICATED FOR THE PROJECT. <br />C. COMPLY WITH PARTS OF ANSI 108 SERIES OF FINE INSTALLATION STANDARDS INCLUDED UNDER "AMERICAN <br />NATIONAL STANDARD SPECIFICATIONS FOR THE INSTALLER OF CERAMIC TILE" THAT APPLY TO TYPE OF <br />SETTING AND GROUT MATERIALS AND METHODS INDICATED. TILE MAY BE THIN -SET. <br />ID2 MORTAR AND GROUT <br />A. MORTAR SHALL BE PORTLAND CEMENT ASTM C150, TYPE 1. GROUT SHALL BE ACID RESISTANT UPCO <br />HYDROMENT, TYPE AS RECOMMENDED BY THE MANUFACTURER FOR THE SPECIFIC TYPE OF TILE AND <br />METHOD OF INSTALLATION. COLR FOR FLOOR TILE IS SPECIFIED ON THE DRAWINGS. <br />B. DO NOT GROUT TILE UNTIL TILE IS FIRMLY SET. SOAK OR DAMPEN JOINTS OF THE TILE TO BE GROUTED WITH <br />PORTLAND CEMENT GROUT. SOAK OR DAMPEN OTHER JOINTS AS RECOMMENDED BY THE GROUT <br />MANUFACTURER FORCE GROUT INTO JOINT LINES COMPLETELY IDLING JOINTS WITH COMPACTED GROUT AND <br />COVERING MORTAR FINISH JOINTS OF SQUARE EDGED TILE FLUSH WITH SURFACE. STRIKE OFF TOOL JOINTS <br />OF CUSHION EDGED TILE TO DEPTH OF CUSHION. FILL GAPS AND SKIPS, AND RETOOL. <br />1.03 CLEANING <br />A UPON COMPLETION OF THE PLACEMENT AND GROUTING, CLEAN TILE SURFACE 50 THAT THEY ARE FREE OF <br />FOREIGN MATTER. REMOVE LATEX-PORTLAND CEMENT GROUT RESIDUE FROM TILE AS SOON AS P05515LE <br />UNGLAZED TILE MAY BE CLEANED WITH ACID SOLUTIONS ONLY WHEN PERMITTED BY TILE AND GROUT <br />MANUFACTURER'S PRINTED INSTRUCTIONS, BUT SOONER THAN 14 DAYS AFTER INSTALLATION. FLUSH SURFACE <br />WITH CLEAN WATER BEFORE AND AFTER CLEANING. <br />END OF SECTION Oe300 <br />DIVISION S FINISHES (CONT.) <br />SECTION 09511 ACOUSTIC PANEL CEILINGS <br />PART 1 GENERAL. <br />1.01 GENERAL <br />A. COORDINATE LAYOUT AND INSTALLATION OF ACOUSTICAL CEILING UNITS AND SUSPENSION SYSTEH <br />COMPPONENTS WITH OTHER CONSTRUCTION THAT PENETRATES CEILINGS OR 15 SUPPORTED BY THEM, <br />INCLUDING LIGHT FIXTURES AND HVAG EQUIPMENT. <br />1.02 MINERAL -FIBER ACOUSTICAL PANELS <br />A. PROVIDE ACOUSTICAL PANELS AS MANUFACTURED BY ARMSTRONG CIRRUS ANGLED TEGULAR <br />24 INCHES BY 24 INCHES 3/4 INCHES THICK WHITE, REFER TO DRAWINGS FOR LIMITS OF TILE <br />INSTALLATION, <br />B, INSTALL IN STRICT ACCORDANCE WITH THE MANUFACTURER'S PRINTED INSTRUCTIONS. ARRANGE <br />ACOUSTICAL UNITS AND ORIENT DIRECTIONAL PATTERN OF TILES FOR A UNIFORM APPEARANCE. REST <br />PANELS ON FLANGES OR INVERTED TEES WITH TILE UNITS FITTING NEATLY AGAINST BUTTING SURFACE <br />AND SUPPORT BY WALL ANGLES. <br />123 METAL SUSPENSION SYSTEM <br />A. PROVIDE SYSTEM AS MANUFACTURED BY ARMSTRONG SUSPENSION SYSTEM SHALL BE EXPOSED <br />TEE -GRID, DOUBLE -WEB, INTERMEDIATE DUTY (ASTM C635), ELECTROGALVANIZED, COLD -ROLLED STEEL, <br />15/16 INCHES WIDE, CAPPED BOTTOM FLANGE. WHITE IN COLOR SYSTEM TO INCLUDE ALL CROSS TEES, <br />BRIDGING TREES, INTERSECTION CLIPS, SPLICES, COMPLETE EXPOSED GRID SYSTEM. <br />B. LAY OUT PATTERN IN ACCORDANCE WITH THE DRAWINGS, LEVEL, TRUE TO PLANE, AND AT THE REQUIRED <br />ELEVATION. FRAME AROUND ALL OPENINGS IN CEILING LIGHTS AND GRILLES WITH MAIN RUNNERS. HANGERS <br />ARE TO BE SPACED AT 4'-0" ON CENTER MAXIMUM. PROVIDE ADDITIONAL HANGERS AS REQUIRED TO <br />SUPPORT LIGHT FIXTURES AND HVAC REGISTERS AND GRILLES AND INTERFERENCES OF DUCT WORK. <br />C, SECURES WIRES BY LOOPING AND WIRE -TYING, EITHER DIRECTLY TO STRUCTURES OR TO INSERTS, EYE <br />SCREWS, OR OTHER DEVICES APPROPRIATE FOR SUBSTRATE. SCREW ATTACH EDGE MOLDINGS TO <br />SUBSTRATE AT INTERVALS NOT OVER I6 INCHES ON CENTER AND NOT MORE THAN 3 INCHES FROM ENDS. <br />LEVEL GRID TO A TOLERANCE OF 1/8" IN 12 FEET. <br />END OF SECTION 09511 <br />SECTION 09650 VINYL COMPOSITION TILE <br />PART 1 GENERAL <br />1.01 SUMMARY <br />A. PROVIDE TYPE AND STYLE AS SCHEDULED IN THE FINISH MATERIAL SCHEDULE. <br />B. ADHESIVES. <br />1. PROVIDE WHITE LATEX CARPET ADHESIVE SUCH A$ W.W. HENRY COMPANY NO 356, ROBERTS <br />COMPANY NO. 41-0504, OR AN EQUAL APPROVED BY THE ARCHITECT AND RECOMMENDED <br />FOR THE PURPOSE BY THE MANUFACTURER OF THE SELECTED CARPET. <br />2. PROVIDE SEAM ADHESIVE SUCH AS W.W. HENRY COMPANY NO.246, ROBERTS COMPANY NO. <br />41-0502, OR AN EQUAL APPROVED BY THE ARCHITECT AND RECOMMENDED FOR THE PURPOSE <br />BY THE MANUFACTURER OF THE SELECTED CARPET. <br />C. AT INTERSECTION OF CARPET AND FLOOR TILE, PROVIDE ROPPE COMPANY, INC. VINYL TILE CARPET JOINER <br />188 OR EQUIVALENT. <br />D. PROVIDE OTHER MATERIALS, NOT SPECIFICALLY DESCRIBED BUT REQUIRED FOR A COMPLETE AND <br />PROPER INSTALLATION, AS SELECTED BY THE CONTRACTOR, SUBJECT TO THE APPROVAL OF THE <br />ARCHITECT. <br />E. ALLOW THE OWNER TO INSPECT AND SELECT FROM SCRAP CARPET REMAINING AFTER THE INSTALLATION. <br />BUNDLE, WRAP IN BURLAP, AND DELIVER TO THE OWNER THE CARPET SCRAPS SO SELECTED. <br />SECTION 096W CARPETING <br />PART 1 GENERAL <br />1.01 CARPETING <br />A, PROVIDE TYPE AND STYLE AS SCHEDULED IN THE FINISH MATERIAL SCHEDULE. <br />B. ADHESIVES, <br />I. PROVIDE WHITE LATEX CARPET ADHESIVE SUCH AS W.W. HENRY COMPANY NO 356, R05ERTS <br />COMPANY NO.41-0504, OR AN EQUAL APPROVED BY THE ARCHITECT AND RECOMMENDED <br />FOR THE PURPOSE BY THE MANUFACTURER OF THE SELECTED CARPET. <br />2. PROVIDE SEAM ADHESIVE SUCH AS W.W. HENRY COMPANY NO.246, R05ERTS COMPANY NO. <br />41-0502, OR AN EQUAL APPROVED BY THE ARCHITECT AND RECOMMENDED FOR THE PURPOSE <br />BY THE MANUFACTURER OF THE SELECTED CARPET. <br />C. AT INTERSECTION OF CARPET AND FLOOR TILE, PROVIDE ROPPE COMPANY, INC. VINYL TILE CARPET JOINER <br />168 OR EQUIVALENT. <br />D. PROVIDE OTHER MATERIALS, NOT SPECIFICALLY DESCRIBED BUT REQUIRED FOR A COMPLETE AND <br />PROPER INSTALLATION, AS SELECTED BY THE CONTRACTOR, SUBJECT TO THE APPROVAL OF THE <br />ARCHITECT. <br />E. ALLOW THE OWNER TO INSPECT AND SELECT FROM SCRAP CARPET REMAINING AFTER THE INSTALLATION. <br />BUNDLE, WRAP IN BURLAP, AND DELIVER TO THE OWNER THE CARPET SCRAPS 50 SELECTED. <br />END OF SECTION 09560 <br />SECTION 09900 PAINTING <br />PART I GENERAL <br />1.01 GENERAL <br />A. IT 15 THE INTENT OF THIS SPECIFICATION TO PRODUCE A PREMIUM JOB, WHICH WILL PROVIDE THE MAXIMUM <br />DURABILITY, WHICH CAN REASONABLY BE EXPECTED FROM A PAINTED SURFACE. <br />B. "PAINT" INCLUDES COATING SYSTEMS MATERIALS, PRIMERS, EMULSIONS, ENAMELS, STAINS, SEALERS, AND <br />FILLERS, AND OTHER APPLIED MATERIALS WHETHER USED AS PRIME, INTERMEDIATE, OR FINISH COAT. <br />C. SPECIFIED PRODUCTS BELOW ARE MANUFACTURED BY SHERWIN WILLIAMS, EXCEPT WHERE OTHER <br />MANUFACTURERS ARE INDICATED, AND ESTABLISH A STANDARD OF QUALITY. EQUIVALENT PRODUCTS OF <br />OTHER ACCEPTABLE MANUFACTURERS MAY NOT BE USED UNLESS APPROVED BY ARCHITECT, <br />D. PROVIDE BEST GRADE AND QUALITY MATERIALS AND PRODUCTS MANUFACTURED BY SHERWIN WILLIAMS. <br />MATCH COLORS AS INDICATED ON THE DRAWINGS, USE PREMIXED PAINTS INSOFAR AS POSSIBLE. THIN ONLY <br />AS PERMITTED ANY MANUFACTURER'S LABEL INSTRUCTIONS, AND AVOID UNNECESSARY THINNING. <br />E. PROTECT FINISHED SURFACES, WORK OF OTHER TRADES, AND PROPERTY OF THE OWNER FROM DAMAGE AND <br />DEFACEMENT. COVER FLOORS AND FIXED EQUIPMENT WITH DROP CLOTHS. <br />F. PREPARE SURFACES ACCORDING TO PAINT MANUFACTURER'S INSTRUCTIONS. EXAMINE FACTORY FINISHED <br />AND PRIMED SURFACES TO BE PAINTED, AND VERIFY COMPATIBILITY OF EXISTING MATERIAL WITH PAINT TO <br />BE APPLIED. APPLY PAINT IN STRICT ACCORDANCE WITH THE MANUFACTURER'S PRINTED INSTRUCTIONS <br />ONLY TO SURFACES WHICH ARE THOROUGHLY DRY, SMOOTH, EVEN, CLEAN, FREE OF DUST AND PROPERLY <br />PREPARED TO RECEIVE THE INTENDED FINISH. <br />1.02 PAINTING <br />A. ACCEPTABLE MATERIALS <br />1. ALL PAINTING TO BE SCHEDULED IN THE FINISH SCHEDULE. <br />2. EQUIVALENT PRODUCTS OF THE FOLLOWING ARE ALSO ACCEPTABLE: <br />PRATT 4 LANBERTT <br />GLIDDEN <br />PORTER <br />BENJAMINE MOORE <br />B. UNDERCOATS AND THINNERS <br />I. PROVIDE UNDERCOAT PAINT PRODUCED BY THE SAME MANUFACTURER <br />OF FIN15H COAT, <br />2. USE ONLY THINNERS RECOMMENDED BY THE PAINT MANUFACTURER AND USE ONLY <br />THE RECOMMENDED LIMITS. <br />C. COLOR SCHEDULES <br />I. PROVIDE PAINTING AS SCHEDULED IN THE FINISH MATERIALS SCHEDULE. <br />a. ON GYPSUM DRYWALL, USE: <br />1. FIRST COAT - PIGMENTED PRIMER/SEALER <br />2. SECOND COAT - ACRYLIC LATEX ENAMEL <br />3. THIRD COAT - ACRYLIC LATEX ENAMEL <br />b. ON FERROUS METAL, USE: <br />1. FIRST COAT - RUST INHIBITIVE ALKYD METAL PRIMER <br />2. SECOND COAT - SEMI -GLOSS ALKYD ENAMEL <br />3. THIRD COAT - SEMI -GLOSS ALKYD ENAMEL <br />c. ON WOOD DOORS, USE: <br />I. FIRST COAT - STAIN (SEE FINISH SCHEDULE) <br />2. SECOND COAT - STAIN (SEE FINISH SCHEDULE) <br />3. THIRD COAT - VARNISH LOW SHEEN "RUBBED EFFECT" <br />END OF SECTION OS900 <br />DIVISION S FINISHES (CONT.) <br />SECTION 09960 STUCCO FINISH <br />PART I GENERAL <br />IDI SUMMARY <br />A. MATERIALS AND INSTALLATION OF CEMENT STUCCO ON HOLLOW MASONRY, EXTERIOR GRADE PLYWOOD AND <br />METAL LATH ALSO FURNISH AND INSTALL METAL, LATH, STUCCO WRAP AND ACCESSORIES. <br />1.02 DELIVERY, STORAGE AND HANDLING <br />A. DELIVER ALL CEMENT MATERIALS IN ORIGINAL CONTAINERS BEARING MANUFACTURERS NAME AND <br />IDENTIFICATION. <br />B. DELIVER NEW, FLAT STRUCTURAL METAL LATH IN ORDINAL PACKAGING. <br />C. PROTECT PRODUCTS FROM MOISTURE AND HUMIDITY. STORE UNDER COVER OFF GROUND IN A DRY <br />LOCATION, <br />1.03 SUBMITTALS <br />A. MANUFACTURERS SPECIFICATION AND PRODUCT DATA FOR STUCCO APPLICATIONS. <br />B. STUCCO WRAP STRUCTURAL METAL LATH AND ACCESSORIES, SUCH AS COMER BEAD, CONTROL JOINTS, ETC. <br />PART 2 PRODUCTS <br />2.01 JOB MIXED INGREDIENTS <br />A. PORTLAND CEMENT, ASTMC 150 TYPE I, MIXED IN ACCORD WITH MANUFACTURERS INSTRUCTIONS. <br />B. WATER: CLEAN AND POTABLE. <br />C. METAL LATH <br />1. STRUCTURAL METAL LATH SHALL BE 3A POUND EXPANDED METAL SHEET WITH SOLID PARALLEL RIBS. <br />2. METAL LATH SHALL BE 3A POUND DIAMOND MESH METAL LATH. <br />3. ACCESSORIES FURNISHED BY SAME MANUFACTURER FOR STUCCO APPLICATION. <br />D. MECHANICAL FASTENERS <br />I. NAILS, 8d RING SHANK HOT DIP GALVANIZED OF SUFFICIENT LENGHTH TO PENETRATE PLYWOOD BACKING <br />I INCH. <br />2. WHERE LIGHT METAL FRAMING OCCURS: MINIMUM NOB SELF DRILLING CORROSION RESISTANT SCREWS OF <br />SUFFICIENT LENGTH TO PENTRATE METAL 3/8 INCH. <br />E. STUCCO WRAP <br />I. BY "TYVEK" FOR USE OVER PLYWOOD AND/OR DENSGLASS FACINGS/SHEATHINGS. <br />F. STUCCO ACCESSORY TRIM, BEADS, AND CONTROL JOINTS SHALL BE VINYL. <br />PART 3 EXECUTION <br />3.01 INSTALLATION <br />A INSTALL MECHANICAL FASTENERS ON 6 INCH CENTERS ALONG SEAMS AND 12 INCH CENTERS ALONG <br />INTERIORS. <br />B. STUCCO INSTALLATION SHALL BE TWO COAT APPLICATION. APPLY BASE COAT WITH FIRM PRESSURE TO <br />FORM GOOD BOND THEN DOUBLE BACK TO PROVIDE THICKNESS. LEAVE ROUGH ENOUGH TO PROVIDE BOND <br />FOR FINISH COAT. FINISH COAT SHALL BE OF TEXTURE AS CALLED FOR ON THE BUILDING ELEVATION <br />DRAWINGS. <br />C. CURING: CURE STUCCO BY USE OF POLYETHYLENE FILM, OR BY USE OF FINE SPRAY. <br />3.02 PROTECTION <br />A. PROTECT STUCCO DURING AND UPON COMPLETION FROM WATER INFILTRATION, DUST, DIRT, PRECIPITATION, <br />EXCESSIVE DRYING UNTIL STUCCO HAS SET. <br />END OF SECTION 099roO <br />DIVISION 10 SPECIALTIES <br />SECTION k522 FIRE EXTINGUISHERS <br />PART I GENERAL <br />101 SUBMITTALS <br />A PRODUCT DATA: 1'61.1IRED <br />B. SHOP DRAWINGS: ,IOT REQUIRED <br />C. SAMPLES: NOT F4&IRED <br />PART 2 PRODUC46 <br />2.01 MANLFACTURER5/PR.ODUCTS <br />A COORDINATE WITWOCAL MUNICIPALITIES AND PROVIDE FIRE EXTINGUISHERS. <br />B. FIRE EXTINGUISHE S: SEE DRAWINGS FOR SPECIFICATIONS. <br />PART 3 EXECUTION <br />3.01 SCHEDULES <br />A INSTALL AS REQUIRED. <br />END OF SECTION 10522 <br />SECTION 10800 TOILET ACCESSORIES <br />PART I GENERAL <br />1.01 SUBMITTALS <br />A. PRODUCT DATA: NON -REQUIRED <br />B. SHOP DRAWINGS: NON -REQUIRED <br />C. SAMPLES: NON -REQUIRED <br />PART 2 PRODUCTS <br />2.DI MANUFACTURERS/PRODUCTS <br />A ACCESSORIES SHALL BE AS MANUFACTURED BY "BRADLEY" OR EQUAL BY "BOBRICK" SEE DRAWINGS <br />FOR SPECIFICATIONS. <br />PART 3 EXECUTION <br />3.01 SCHEDULES <br />A COORDINATE WITH DRAWINGS. <br />END OF SECTION 10600 <br />SECTION 10WO MISCELLANEOUS SPECIALTIES <br />PART I GENERAL <br />101 RELATED DOCUMENTS <br />A REQUIREMENTS OF DIVISION I APPLY TO ALL WORK HEREUNDER <br />1.02 SCOPE <br />A PROVIDE MISCELLANEOUS SPECIALTIES AND RELATED ITEMS AS REQUIRED TO COMPLETE WORK <br />INDICATED ON DRAWINGS AND SPECIFIED HEREIN. <br />1.03 QUALITY ASSURANCE <br />A FIELD MEASUREMENTS: TAKE FIELD MEASUREMENTS PRIOR TO PREPARATION OF SHOP DRAWINGS <br />AND FABRICATION WHERE NECESSARY TO ENSURE PROPER FITTING OF WORK <br />B. B, INSERTS AND ANCHORAGE'S: FURNISH INSERTS AND ANCHORING DEVICES WHICH MUST BE SET IN <br />CONCRETE OR MASONRY FOR INSTALLATION OF UNIT. PROVIDE SETTING DRAWINGS, TEMPLATES, <br />INSTRUCTIONS AND DIRECTIONS FOR INSTALLATION OF ANCHORAGE DEVICES. COORDINATE <br />DELIVERY WITH OTHER WORK TO AVOID DELAY. <br />PART 2 PRODUCTS <br />2.01 MANUFACTURERS/PRODUCTS <br />A. MFRS' NAMES AND PRODUCT NUMBERS LISTED IN SPECIALTIES SCHEDULE ARE FOR DESCRIPTIVE <br />PURPOSE AND ALL, UNLESS SPECIFICALLY PROHIBITED THEREIN, SHALL BE SUBJECT <br />TO REQUESTS FOR APPROVAL FOR EQUAL PRODUCTS IN CONFORMANCE WITH SECTION 01600. <br />PART 3 EXECUTION <br />3.01 INSTALLATION <br />A INSTALLATION OF MISCELLANEOUS ITEMS SHALL BE IN COMPLIANCE WITH MFR'S CURRENT PRINTED <br />RECOMMENDATIONS AND AS MAY BE SHOWN ON DRAWINGS AND SPECIFIED HEREINAFTER <br />PART 4 SPECIALTIES <br />421 MISCELLANEOUS SPECIALTIES SCHEDULE <br />A PROVIDE FOLLOWING ITEMS: <br />1. RESIDENTIAL KITCHEN EQUIPMENT <br />a. REFRIGERATOR <br />IUKENMORE MODEL NO.46-1W42, 18 CU.. FT. REFRIGERATOR/FREEZER WITH AUTOMATIC ICE MAKER - <br />COLOR - WHITE ON WHITE. <br />B. MICROWAVE <br />I. KENMORE MODEL NO.20-69301. <br />C. COUNTERTOP ICEMAKER <br />I. DCM - 210 BAH, I6 S/16" x 24 3/16" x 31 1/8" BY HOSHIZAKI AMERICA INC. (800) 345-1325 <br />END OF SECTION 10S50 <br />DIVISION 11 EQUIP'MENT <br />NONE SPECIFIED <br />DIVISION 12 FURNISHI� <br />NONE SPECIFIED <br />DIVISION 13 SPECIAL CONSTRUCTION <br />a 11 1A e <br />DIVISION 14 CONVEYING-$ SYSTEMS <br />NONE SPECIFIED <br />DIVISION 15 MECHANICAL <br />SEE MECHANICAL <br />DIVISION 16 ELECTRICAL <br />REVISIONS BY <br />v. <br />� N 00 <br />N <br />C", <br />o u <br />o <br />E ti o <br />c� <br />�1 <br />w <br />00 <br />N <br />� o <br />o � <br />Q <br />o # <br />G <br />a u <br />0ZW <br />O J F- <br />CL U Z a) <br />L+J Ld p .D <br />C Q N O <br />a UW �`` <br />O 0�N <br />v.tn <br />o �U <br />C F- <br />-C <br />a <br />�QWp001V <br />2 OM <br />�:3 J <br />m LJ_ <br />Date: 06. 12. 12 <br />Scale: AS NOTED <br />Project Mgr: AAY <br />Drawn: AZP <br />Job: 10-61 <br />Sheet <br />N2 <br />H,\Projects\Projects 2010\1061 - FMC Urgent Care\04-CD\01-CD.A\04-Architectural\N-SPECS.dwg, 6/13/2012 2:04:14 PM, Adobe PDF.pc3 <br />r <br />SEE ELECTRICAL <br />