DIVISION Tl FINISHES
<br />SECTION 0911,E METAL SYSTEMS
<br />METAL STUDS
<br />A. AT INTERIOR METAL STUD PARTITIONS, UNLESS OTHERWISE SHOWN ON THE DRAWINGS, PROVIDE
<br />STANDARD PUNCH STEEL STUDS OF THE SIZES SHOWN ON THE DRAWINGS, EITHER HOT -DIP
<br />GALVANIZED OR FACTORY PRE -PAINT: 25 GA. UNLESS SHOWN OTHERWISE ON THE DRAWINGS. 20
<br />GA. AT ALL DOOR OPENINGS.
<br />B. ACCESSORIES: PROVIDE ALL ACCESSORIES INCLUDING, BUT NOT NECE55ARILY LIMITED TO,
<br />TRACKS, CLIPS, ANCHORS, FASTENING DEVICES, SOUND ATTENUATION PENCIL RODS AND
<br />RESILIENT CLIPS, AND OTHER ACCESSORIES REQUIRED FOR A COMPLETE AND PROPER
<br />INSTALLATION, AND AS RECOMMENDED BY THE MANUFACTURER OF THE STEEL STUDS USED,
<br />C. MEET OR EXCEED MINIMUM REQUIREMENTS OF FEDERAL SPEC. QQ-54098 AND FEDERAL SPEC.
<br />QQ-5-115p, CLASS p.
<br />METAL TRIM
<br />A. FORM FROM GALVANIZE[) STEEL NOT LIGHTER THAN 26 GAUGE, COMPLYING WITH FEDERAL SPEC
<br />QQ-5-115, CLASS D.
<br />B. CASING BEADS: U.S.G. *200-5.
<br />END OF SECTION 0g110
<br />SECTION OW50 GYPSUM WALLBOARD
<br />PART 1 GENERAL
<br />1.01 GENERAL
<br />A. GYPSUM WALLBOARD WORK SHALL CONFORM TO THE GYPSUM ASSOCIATION "RECOMMENDED
<br />SPECIFICATIONS FOR THE APPLICATION AND FINISHING OF GYPSUM WALLBOARD."
<br />B. EXAMINE SUBSTRATES TO WHICH DRY WALL CONSTRUCTION ATTACHES OR ABUTT5, PRESET HOLLOW METAL
<br />FRAMES, CAST-IN-ANCORS, AND STRUCTURAL FRAMING FOR COMPLIANCE WITH REQUIREMENTS FOR
<br />INSTALLATION TOLERANCE AND OTHER CONDITIONS AFFECTING PERFORMANCE OF DRY WALL
<br />CONSTRUCTION. DO NOT PROCEED WITH INSTALLATION UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN
<br />CORRECTED.
<br />C. DO NOT TAPE AND FINISH GYPSUM BOARD WHEN THE TEMPERATURE IS BELOW 60 DEGREES FAHRENHEIT.
<br />THE TEMPERATURE OF THE ROOMS SHALL BE HELD AT 60 DEGREES FAHRENHEIT FOR 48 HOURS BEFORE
<br />TAPING AND FINISHING IS TO BEGIN. MAINTAIN 60 DEGREES FAHRENHEIT DURING AND AFTER INSTALLATION.
<br />VENTILATES AS REQUIRED TO REMOVE EXCESS HUMIDITY.
<br />1.02 GYPSUM WALLBOARD
<br />A. GYPSUM WALLBOARD SHALL BE MANUFACTURED BY U.S. GYPSUM. WALLBOARD IS TO MEET. ASTM C36-84A
<br />AND 55-L-30d 1/2 INCHES THICK, 48 INCHES WIDE WITH TAPERED EDGES.
<br />B. AT FIRE RATED PARTITIONS INSTALL WALLBOARD TO MEET SEPARATE REQUIREMENTS, USE TYPE 111, GRADE
<br />X CLASS I, 5/6 INCHES THICK FIRE RETARDANT WALLBOARD.
<br />C. INSTALL GYPSUM BOARD WITH TRUE, EVEN SURFACES AND STRAIGHT, SHARP CORNERS. USE FULL LENGTH
<br />BOARDS WHERE POSSIBLE. END JOINTS ON THE SAME SIDE OF A WALL SHALL BE STAGGERED AND JOINTS
<br />ON OPPOSITE SIDE SHALL NOT OCCUR OVER THE SAME SUPPORT. DO NOT LOCATE NORMAL END JOINTS AT
<br />EDGE OF OPENINGS. FORM JOINTS NEATLY. BUTT BOARDS TOGETHER BUT DO NOT FORCE INTO PLACE. DO
<br />NOT BUTT EDGES AGAINST TAPERED EDGES. NO JOINT SHALL HAVE A GAP GREATER THAN 1/4 INCH.
<br />D. IN GENERAL, INSTALL GYPSUM BOARD ON CEILING BEFORE WALLS. CONSTRUCT CEILINGS WITH LONG
<br />DIMENSION OF GYPSUM BOARD APPLIED AT RIGHT ANGLES TO SUPPORT.
<br />E. SCREW GYPSUM BOARD TO FRAMING WITH SCREWS NOT OVER 8 INCHES ON CENTER FASTEN GYPSUM
<br />BOARD BEGINNING AT THE CENTER AND WORK TOWARDS OUTER EDGES. HOLD BOARD FIRMLY AGAINST
<br />WOOD FRAMING WHILE FASTENING. FASTENERS AT EDGES OF BOARDS SHALL BE 1/2 INCH FROM THE EDGE.
<br />F. OPENINGS FOR ELECTRICAL DEVICES, PIPING, GRILLS, AND REGISTERS SHALL BE ACCURATELY LOCATED
<br />AND NEATLY MADE TO CLOSELY FIT THE DEVICES AND BE COMPLETELY COVERED BY PLATES AND
<br />ESCUTCHEONS.
<br />1.03 TRIM PIECES
<br />A PROVIDE TRIM ACCESSORIES OF THE SIZES REQUIRED FOR THE WALLBOARD APPLICATION AS
<br />MANUFACTURED BY U.S. GYPSUM. PROVIDE DUR-A-BEAD CORNER BEAD AT EXTERNAL CORNERS AND NO.
<br />200-A METAL CASING BEAD WHERE WALLBOARD ABUTTS OTHER MATERIALS.
<br />1.04 FASTENERS
<br />A. PROVIDE SCREWS, NAILS, CLIPS, TIES, AND OTHER FASTENERS AS RECOMMENDED BY THE GYPSUM
<br />MANUFACTURER
<br />1.05 JOINT TREATMENT SYSTEMS
<br />A. SYSTEM SHALL BE PERFORATED TAPE AND CEMENT RECOMMENDED THE GYPSUM MANUFACTURER
<br />B. APPLY MATERIALS IN STRICT ACCORDANCE TO MANUFACTURER'S RECOMMENDATIONS. FILL JOINTS WITH
<br />JOINT COMPOUND, EMBED PERFORATED TAPE AND APPLY A SKIM COAT OF JOINT COMPOUND OVER TAPE.
<br />APPLY TWO ADDITIONAL COATS OF JOINT COMPOUND ALLOWING AT LEAST 24 HOURS BETWEEN EACH COAT.
<br />SAND EACH COAT. FINISH SURFACES SHALL BE UNIFORMLY SMOOTH, TRUE AND IN SATISFACTORY CONDITION
<br />TO RECEIVE PAINT.
<br />END OF SECTION 09250
<br />SECTION OWOO CERAMIC TILE
<br />PART 1 GENERAL
<br />101 GENERAL
<br />A. CERAMIC AND TYPES ARE INDICATED ON THE DRAWINGS AND ARE FROM A SINGLE MANUFACTURER OTHER
<br />MANUFACTURERS WILL NOT BE CONSIDERED.
<br />B. DELIVER MATERIALS IN ORIGINAL CONTAINERS WITH SEALS UNBROKEN AND LABELS INTACT UNTIL TIME OF
<br />USES. ENGAGE AN EXPERIENCED INSTALLER WHO HAS SUCCESSFULLY COMPLETED TILE INSTALLATIONS
<br />SIMILAR IN MATERIAL, DESIGN, AND EXTENT TO THAT INDICATED FOR THE PROJECT.
<br />C. COMPLY WITH PARTS OF ANSI 108 SERIES OF FINE INSTALLATION STANDARDS INCLUDED UNDER "AMERICAN
<br />NATIONAL STANDARD SPECIFICATIONS FOR THE INSTALLER OF CERAMIC TILE" THAT APPLY TO TYPE OF
<br />SETTING AND GROUT MATERIALS AND METHODS INDICATED. TILE MAY BE THIN -SET.
<br />ID2 MORTAR AND GROUT
<br />A. MORTAR SHALL BE PORTLAND CEMENT ASTM C150, TYPE 1. GROUT SHALL BE ACID RESISTANT UPCO
<br />HYDROMENT, TYPE AS RECOMMENDED BY THE MANUFACTURER FOR THE SPECIFIC TYPE OF TILE AND
<br />METHOD OF INSTALLATION. COLR FOR FLOOR TILE IS SPECIFIED ON THE DRAWINGS.
<br />B. DO NOT GROUT TILE UNTIL TILE IS FIRMLY SET. SOAK OR DAMPEN JOINTS OF THE TILE TO BE GROUTED WITH
<br />PORTLAND CEMENT GROUT. SOAK OR DAMPEN OTHER JOINTS AS RECOMMENDED BY THE GROUT
<br />MANUFACTURER FORCE GROUT INTO JOINT LINES COMPLETELY IDLING JOINTS WITH COMPACTED GROUT AND
<br />COVERING MORTAR FINISH JOINTS OF SQUARE EDGED TILE FLUSH WITH SURFACE. STRIKE OFF TOOL JOINTS
<br />OF CUSHION EDGED TILE TO DEPTH OF CUSHION. FILL GAPS AND SKIPS, AND RETOOL.
<br />1.03 CLEANING
<br />A UPON COMPLETION OF THE PLACEMENT AND GROUTING, CLEAN TILE SURFACE 50 THAT THEY ARE FREE OF
<br />FOREIGN MATTER. REMOVE LATEX-PORTLAND CEMENT GROUT RESIDUE FROM TILE AS SOON AS P05515LE
<br />UNGLAZED TILE MAY BE CLEANED WITH ACID SOLUTIONS ONLY WHEN PERMITTED BY TILE AND GROUT
<br />MANUFACTURER'S PRINTED INSTRUCTIONS, BUT SOONER THAN 14 DAYS AFTER INSTALLATION. FLUSH SURFACE
<br />WITH CLEAN WATER BEFORE AND AFTER CLEANING.
<br />END OF SECTION Oe300
<br />DIVISION S FINISHES (CONT.)
<br />SECTION 09511 ACOUSTIC PANEL CEILINGS
<br />PART 1 GENERAL.
<br />1.01 GENERAL
<br />A. COORDINATE LAYOUT AND INSTALLATION OF ACOUSTICAL CEILING UNITS AND SUSPENSION SYSTEH
<br />COMPPONENTS WITH OTHER CONSTRUCTION THAT PENETRATES CEILINGS OR 15 SUPPORTED BY THEM,
<br />INCLUDING LIGHT FIXTURES AND HVAG EQUIPMENT.
<br />1.02 MINERAL -FIBER ACOUSTICAL PANELS
<br />A. PROVIDE ACOUSTICAL PANELS AS MANUFACTURED BY ARMSTRONG CIRRUS ANGLED TEGULAR
<br />24 INCHES BY 24 INCHES 3/4 INCHES THICK WHITE, REFER TO DRAWINGS FOR LIMITS OF TILE
<br />INSTALLATION,
<br />B, INSTALL IN STRICT ACCORDANCE WITH THE MANUFACTURER'S PRINTED INSTRUCTIONS. ARRANGE
<br />ACOUSTICAL UNITS AND ORIENT DIRECTIONAL PATTERN OF TILES FOR A UNIFORM APPEARANCE. REST
<br />PANELS ON FLANGES OR INVERTED TEES WITH TILE UNITS FITTING NEATLY AGAINST BUTTING SURFACE
<br />AND SUPPORT BY WALL ANGLES.
<br />123 METAL SUSPENSION SYSTEM
<br />A. PROVIDE SYSTEM AS MANUFACTURED BY ARMSTRONG SUSPENSION SYSTEM SHALL BE EXPOSED
<br />TEE -GRID, DOUBLE -WEB, INTERMEDIATE DUTY (ASTM C635), ELECTROGALVANIZED, COLD -ROLLED STEEL,
<br />15/16 INCHES WIDE, CAPPED BOTTOM FLANGE. WHITE IN COLOR SYSTEM TO INCLUDE ALL CROSS TEES,
<br />BRIDGING TREES, INTERSECTION CLIPS, SPLICES, COMPLETE EXPOSED GRID SYSTEM.
<br />B. LAY OUT PATTERN IN ACCORDANCE WITH THE DRAWINGS, LEVEL, TRUE TO PLANE, AND AT THE REQUIRED
<br />ELEVATION. FRAME AROUND ALL OPENINGS IN CEILING LIGHTS AND GRILLES WITH MAIN RUNNERS. HANGERS
<br />ARE TO BE SPACED AT 4'-0" ON CENTER MAXIMUM. PROVIDE ADDITIONAL HANGERS AS REQUIRED TO
<br />SUPPORT LIGHT FIXTURES AND HVAC REGISTERS AND GRILLES AND INTERFERENCES OF DUCT WORK.
<br />C, SECURES WIRES BY LOOPING AND WIRE -TYING, EITHER DIRECTLY TO STRUCTURES OR TO INSERTS, EYE
<br />SCREWS, OR OTHER DEVICES APPROPRIATE FOR SUBSTRATE. SCREW ATTACH EDGE MOLDINGS TO
<br />SUBSTRATE AT INTERVALS NOT OVER I6 INCHES ON CENTER AND NOT MORE THAN 3 INCHES FROM ENDS.
<br />LEVEL GRID TO A TOLERANCE OF 1/8" IN 12 FEET.
<br />END OF SECTION 09511
<br />SECTION 09650 VINYL COMPOSITION TILE
<br />PART 1 GENERAL
<br />1.01 SUMMARY
<br />A. PROVIDE TYPE AND STYLE AS SCHEDULED IN THE FINISH MATERIAL SCHEDULE.
<br />B. ADHESIVES.
<br />1. PROVIDE WHITE LATEX CARPET ADHESIVE SUCH A$ W.W. HENRY COMPANY NO 356, ROBERTS
<br />COMPANY NO. 41-0504, OR AN EQUAL APPROVED BY THE ARCHITECT AND RECOMMENDED
<br />FOR THE PURPOSE BY THE MANUFACTURER OF THE SELECTED CARPET.
<br />2. PROVIDE SEAM ADHESIVE SUCH AS W.W. HENRY COMPANY NO.246, ROBERTS COMPANY NO.
<br />41-0502, OR AN EQUAL APPROVED BY THE ARCHITECT AND RECOMMENDED FOR THE PURPOSE
<br />BY THE MANUFACTURER OF THE SELECTED CARPET.
<br />C. AT INTERSECTION OF CARPET AND FLOOR TILE, PROVIDE ROPPE COMPANY, INC. VINYL TILE CARPET JOINER
<br />188 OR EQUIVALENT.
<br />D. PROVIDE OTHER MATERIALS, NOT SPECIFICALLY DESCRIBED BUT REQUIRED FOR A COMPLETE AND
<br />PROPER INSTALLATION, AS SELECTED BY THE CONTRACTOR, SUBJECT TO THE APPROVAL OF THE
<br />ARCHITECT.
<br />E. ALLOW THE OWNER TO INSPECT AND SELECT FROM SCRAP CARPET REMAINING AFTER THE INSTALLATION.
<br />BUNDLE, WRAP IN BURLAP, AND DELIVER TO THE OWNER THE CARPET SCRAPS SO SELECTED.
<br />SECTION 096W CARPETING
<br />PART 1 GENERAL
<br />1.01 CARPETING
<br />A, PROVIDE TYPE AND STYLE AS SCHEDULED IN THE FINISH MATERIAL SCHEDULE.
<br />B. ADHESIVES,
<br />I. PROVIDE WHITE LATEX CARPET ADHESIVE SUCH AS W.W. HENRY COMPANY NO 356, R05ERTS
<br />COMPANY NO.41-0504, OR AN EQUAL APPROVED BY THE ARCHITECT AND RECOMMENDED
<br />FOR THE PURPOSE BY THE MANUFACTURER OF THE SELECTED CARPET.
<br />2. PROVIDE SEAM ADHESIVE SUCH AS W.W. HENRY COMPANY NO.246, R05ERTS COMPANY NO.
<br />41-0502, OR AN EQUAL APPROVED BY THE ARCHITECT AND RECOMMENDED FOR THE PURPOSE
<br />BY THE MANUFACTURER OF THE SELECTED CARPET.
<br />C. AT INTERSECTION OF CARPET AND FLOOR TILE, PROVIDE ROPPE COMPANY, INC. VINYL TILE CARPET JOINER
<br />168 OR EQUIVALENT.
<br />D. PROVIDE OTHER MATERIALS, NOT SPECIFICALLY DESCRIBED BUT REQUIRED FOR A COMPLETE AND
<br />PROPER INSTALLATION, AS SELECTED BY THE CONTRACTOR, SUBJECT TO THE APPROVAL OF THE
<br />ARCHITECT.
<br />E. ALLOW THE OWNER TO INSPECT AND SELECT FROM SCRAP CARPET REMAINING AFTER THE INSTALLATION.
<br />BUNDLE, WRAP IN BURLAP, AND DELIVER TO THE OWNER THE CARPET SCRAPS 50 SELECTED.
<br />END OF SECTION 09560
<br />SECTION 09900 PAINTING
<br />PART I GENERAL
<br />1.01 GENERAL
<br />A. IT 15 THE INTENT OF THIS SPECIFICATION TO PRODUCE A PREMIUM JOB, WHICH WILL PROVIDE THE MAXIMUM
<br />DURABILITY, WHICH CAN REASONABLY BE EXPECTED FROM A PAINTED SURFACE.
<br />B. "PAINT" INCLUDES COATING SYSTEMS MATERIALS, PRIMERS, EMULSIONS, ENAMELS, STAINS, SEALERS, AND
<br />FILLERS, AND OTHER APPLIED MATERIALS WHETHER USED AS PRIME, INTERMEDIATE, OR FINISH COAT.
<br />C. SPECIFIED PRODUCTS BELOW ARE MANUFACTURED BY SHERWIN WILLIAMS, EXCEPT WHERE OTHER
<br />MANUFACTURERS ARE INDICATED, AND ESTABLISH A STANDARD OF QUALITY. EQUIVALENT PRODUCTS OF
<br />OTHER ACCEPTABLE MANUFACTURERS MAY NOT BE USED UNLESS APPROVED BY ARCHITECT,
<br />D. PROVIDE BEST GRADE AND QUALITY MATERIALS AND PRODUCTS MANUFACTURED BY SHERWIN WILLIAMS.
<br />MATCH COLORS AS INDICATED ON THE DRAWINGS, USE PREMIXED PAINTS INSOFAR AS POSSIBLE. THIN ONLY
<br />AS PERMITTED ANY MANUFACTURER'S LABEL INSTRUCTIONS, AND AVOID UNNECESSARY THINNING.
<br />E. PROTECT FINISHED SURFACES, WORK OF OTHER TRADES, AND PROPERTY OF THE OWNER FROM DAMAGE AND
<br />DEFACEMENT. COVER FLOORS AND FIXED EQUIPMENT WITH DROP CLOTHS.
<br />F. PREPARE SURFACES ACCORDING TO PAINT MANUFACTURER'S INSTRUCTIONS. EXAMINE FACTORY FINISHED
<br />AND PRIMED SURFACES TO BE PAINTED, AND VERIFY COMPATIBILITY OF EXISTING MATERIAL WITH PAINT TO
<br />BE APPLIED. APPLY PAINT IN STRICT ACCORDANCE WITH THE MANUFACTURER'S PRINTED INSTRUCTIONS
<br />ONLY TO SURFACES WHICH ARE THOROUGHLY DRY, SMOOTH, EVEN, CLEAN, FREE OF DUST AND PROPERLY
<br />PREPARED TO RECEIVE THE INTENDED FINISH.
<br />1.02 PAINTING
<br />A. ACCEPTABLE MATERIALS
<br />1. ALL PAINTING TO BE SCHEDULED IN THE FINISH SCHEDULE.
<br />2. EQUIVALENT PRODUCTS OF THE FOLLOWING ARE ALSO ACCEPTABLE:
<br />PRATT 4 LANBERTT
<br />GLIDDEN
<br />PORTER
<br />BENJAMINE MOORE
<br />B. UNDERCOATS AND THINNERS
<br />I. PROVIDE UNDERCOAT PAINT PRODUCED BY THE SAME MANUFACTURER
<br />OF FIN15H COAT,
<br />2. USE ONLY THINNERS RECOMMENDED BY THE PAINT MANUFACTURER AND USE ONLY
<br />THE RECOMMENDED LIMITS.
<br />C. COLOR SCHEDULES
<br />I. PROVIDE PAINTING AS SCHEDULED IN THE FINISH MATERIALS SCHEDULE.
<br />a. ON GYPSUM DRYWALL, USE:
<br />1. FIRST COAT - PIGMENTED PRIMER/SEALER
<br />2. SECOND COAT - ACRYLIC LATEX ENAMEL
<br />3. THIRD COAT - ACRYLIC LATEX ENAMEL
<br />b. ON FERROUS METAL, USE:
<br />1. FIRST COAT - RUST INHIBITIVE ALKYD METAL PRIMER
<br />2. SECOND COAT - SEMI -GLOSS ALKYD ENAMEL
<br />3. THIRD COAT - SEMI -GLOSS ALKYD ENAMEL
<br />c. ON WOOD DOORS, USE:
<br />I. FIRST COAT - STAIN (SEE FINISH SCHEDULE)
<br />2. SECOND COAT - STAIN (SEE FINISH SCHEDULE)
<br />3. THIRD COAT - VARNISH LOW SHEEN "RUBBED EFFECT"
<br />END OF SECTION OS900
<br />DIVISION S FINISHES (CONT.)
<br />SECTION 09960 STUCCO FINISH
<br />PART I GENERAL
<br />IDI SUMMARY
<br />A. MATERIALS AND INSTALLATION OF CEMENT STUCCO ON HOLLOW MASONRY, EXTERIOR GRADE PLYWOOD AND
<br />METAL LATH ALSO FURNISH AND INSTALL METAL, LATH, STUCCO WRAP AND ACCESSORIES.
<br />1.02 DELIVERY, STORAGE AND HANDLING
<br />A. DELIVER ALL CEMENT MATERIALS IN ORIGINAL CONTAINERS BEARING MANUFACTURERS NAME AND
<br />IDENTIFICATION.
<br />B. DELIVER NEW, FLAT STRUCTURAL METAL LATH IN ORDINAL PACKAGING.
<br />C. PROTECT PRODUCTS FROM MOISTURE AND HUMIDITY. STORE UNDER COVER OFF GROUND IN A DRY
<br />LOCATION,
<br />1.03 SUBMITTALS
<br />A. MANUFACTURERS SPECIFICATION AND PRODUCT DATA FOR STUCCO APPLICATIONS.
<br />B. STUCCO WRAP STRUCTURAL METAL LATH AND ACCESSORIES, SUCH AS COMER BEAD, CONTROL JOINTS, ETC.
<br />PART 2 PRODUCTS
<br />2.01 JOB MIXED INGREDIENTS
<br />A. PORTLAND CEMENT, ASTMC 150 TYPE I, MIXED IN ACCORD WITH MANUFACTURERS INSTRUCTIONS.
<br />B. WATER: CLEAN AND POTABLE.
<br />C. METAL LATH
<br />1. STRUCTURAL METAL LATH SHALL BE 3A POUND EXPANDED METAL SHEET WITH SOLID PARALLEL RIBS.
<br />2. METAL LATH SHALL BE 3A POUND DIAMOND MESH METAL LATH.
<br />3. ACCESSORIES FURNISHED BY SAME MANUFACTURER FOR STUCCO APPLICATION.
<br />D. MECHANICAL FASTENERS
<br />I. NAILS, 8d RING SHANK HOT DIP GALVANIZED OF SUFFICIENT LENGHTH TO PENETRATE PLYWOOD BACKING
<br />I INCH.
<br />2. WHERE LIGHT METAL FRAMING OCCURS: MINIMUM NOB SELF DRILLING CORROSION RESISTANT SCREWS OF
<br />SUFFICIENT LENGTH TO PENTRATE METAL 3/8 INCH.
<br />E. STUCCO WRAP
<br />I. BY "TYVEK" FOR USE OVER PLYWOOD AND/OR DENSGLASS FACINGS/SHEATHINGS.
<br />F. STUCCO ACCESSORY TRIM, BEADS, AND CONTROL JOINTS SHALL BE VINYL.
<br />PART 3 EXECUTION
<br />3.01 INSTALLATION
<br />A INSTALL MECHANICAL FASTENERS ON 6 INCH CENTERS ALONG SEAMS AND 12 INCH CENTERS ALONG
<br />INTERIORS.
<br />B. STUCCO INSTALLATION SHALL BE TWO COAT APPLICATION. APPLY BASE COAT WITH FIRM PRESSURE TO
<br />FORM GOOD BOND THEN DOUBLE BACK TO PROVIDE THICKNESS. LEAVE ROUGH ENOUGH TO PROVIDE BOND
<br />FOR FINISH COAT. FINISH COAT SHALL BE OF TEXTURE AS CALLED FOR ON THE BUILDING ELEVATION
<br />DRAWINGS.
<br />C. CURING: CURE STUCCO BY USE OF POLYETHYLENE FILM, OR BY USE OF FINE SPRAY.
<br />3.02 PROTECTION
<br />A. PROTECT STUCCO DURING AND UPON COMPLETION FROM WATER INFILTRATION, DUST, DIRT, PRECIPITATION,
<br />EXCESSIVE DRYING UNTIL STUCCO HAS SET.
<br />END OF SECTION 099roO
<br />DIVISION 10 SPECIALTIES
<br />SECTION k522 FIRE EXTINGUISHERS
<br />PART I GENERAL
<br />101 SUBMITTALS
<br />A PRODUCT DATA: 1'61.1IRED
<br />B. SHOP DRAWINGS: ,IOT REQUIRED
<br />C. SAMPLES: NOT F4&IRED
<br />PART 2 PRODUC46
<br />2.01 MANLFACTURER5/PR.ODUCTS
<br />A COORDINATE WITWOCAL MUNICIPALITIES AND PROVIDE FIRE EXTINGUISHERS.
<br />B. FIRE EXTINGUISHE S: SEE DRAWINGS FOR SPECIFICATIONS.
<br />PART 3 EXECUTION
<br />3.01 SCHEDULES
<br />A INSTALL AS REQUIRED.
<br />END OF SECTION 10522
<br />SECTION 10800 TOILET ACCESSORIES
<br />PART I GENERAL
<br />1.01 SUBMITTALS
<br />A. PRODUCT DATA: NON -REQUIRED
<br />B. SHOP DRAWINGS: NON -REQUIRED
<br />C. SAMPLES: NON -REQUIRED
<br />PART 2 PRODUCTS
<br />2.DI MANUFACTURERS/PRODUCTS
<br />A ACCESSORIES SHALL BE AS MANUFACTURED BY "BRADLEY" OR EQUAL BY "BOBRICK" SEE DRAWINGS
<br />FOR SPECIFICATIONS.
<br />PART 3 EXECUTION
<br />3.01 SCHEDULES
<br />A COORDINATE WITH DRAWINGS.
<br />END OF SECTION 10600
<br />SECTION 10WO MISCELLANEOUS SPECIALTIES
<br />PART I GENERAL
<br />101 RELATED DOCUMENTS
<br />A REQUIREMENTS OF DIVISION I APPLY TO ALL WORK HEREUNDER
<br />1.02 SCOPE
<br />A PROVIDE MISCELLANEOUS SPECIALTIES AND RELATED ITEMS AS REQUIRED TO COMPLETE WORK
<br />INDICATED ON DRAWINGS AND SPECIFIED HEREIN.
<br />1.03 QUALITY ASSURANCE
<br />A FIELD MEASUREMENTS: TAKE FIELD MEASUREMENTS PRIOR TO PREPARATION OF SHOP DRAWINGS
<br />AND FABRICATION WHERE NECESSARY TO ENSURE PROPER FITTING OF WORK
<br />B. B, INSERTS AND ANCHORAGE'S: FURNISH INSERTS AND ANCHORING DEVICES WHICH MUST BE SET IN
<br />CONCRETE OR MASONRY FOR INSTALLATION OF UNIT. PROVIDE SETTING DRAWINGS, TEMPLATES,
<br />INSTRUCTIONS AND DIRECTIONS FOR INSTALLATION OF ANCHORAGE DEVICES. COORDINATE
<br />DELIVERY WITH OTHER WORK TO AVOID DELAY.
<br />PART 2 PRODUCTS
<br />2.01 MANUFACTURERS/PRODUCTS
<br />A. MFRS' NAMES AND PRODUCT NUMBERS LISTED IN SPECIALTIES SCHEDULE ARE FOR DESCRIPTIVE
<br />PURPOSE AND ALL, UNLESS SPECIFICALLY PROHIBITED THEREIN, SHALL BE SUBJECT
<br />TO REQUESTS FOR APPROVAL FOR EQUAL PRODUCTS IN CONFORMANCE WITH SECTION 01600.
<br />PART 3 EXECUTION
<br />3.01 INSTALLATION
<br />A INSTALLATION OF MISCELLANEOUS ITEMS SHALL BE IN COMPLIANCE WITH MFR'S CURRENT PRINTED
<br />RECOMMENDATIONS AND AS MAY BE SHOWN ON DRAWINGS AND SPECIFIED HEREINAFTER
<br />PART 4 SPECIALTIES
<br />421 MISCELLANEOUS SPECIALTIES SCHEDULE
<br />A PROVIDE FOLLOWING ITEMS:
<br />1. RESIDENTIAL KITCHEN EQUIPMENT
<br />a. REFRIGERATOR
<br />IUKENMORE MODEL NO.46-1W42, 18 CU.. FT. REFRIGERATOR/FREEZER WITH AUTOMATIC ICE MAKER -
<br />COLOR - WHITE ON WHITE.
<br />B. MICROWAVE
<br />I. KENMORE MODEL NO.20-69301.
<br />C. COUNTERTOP ICEMAKER
<br />I. DCM - 210 BAH, I6 S/16" x 24 3/16" x 31 1/8" BY HOSHIZAKI AMERICA INC. (800) 345-1325
<br />END OF SECTION 10S50
<br />DIVISION 11 EQUIP'MENT
<br />NONE SPECIFIED
<br />DIVISION 12 FURNISHI�
<br />NONE SPECIFIED
<br />DIVISION 13 SPECIAL CONSTRUCTION
<br />a 11 1A e
<br />DIVISION 14 CONVEYING-$ SYSTEMS
<br />NONE SPECIFIED
<br />DIVISION 15 MECHANICAL
<br />SEE MECHANICAL
<br />DIVISION 16 ELECTRICAL
<br />REVISIONS BY
<br />v.
<br />� N 00
<br />N
<br />C",
<br />o u
<br />o
<br />E ti o
<br />c�
<br />�1
<br />w
<br />00
<br />N
<br />� o
<br />o �
<br />Q
<br />o #
<br />G
<br />a u
<br />0ZW
<br />O J F-
<br />CL U Z a)
<br />L+J Ld p .D
<br />C Q N O
<br />a UW �``
<br />O 0�N
<br />v.tn
<br />o �U
<br />C F-
<br />-C
<br />a
<br />�QWp001V
<br />2 OM
<br />�:3 J
<br />m LJ_
<br />Date: 06. 12. 12
<br />Scale: AS NOTED
<br />Project Mgr: AAY
<br />Drawn: AZP
<br />Job: 10-61
<br />Sheet
<br />N2
<br />H,\Projects\Projects 2010\1061 - FMC Urgent Care\04-CD\01-CD.A\04-Architectural\N-SPECS.dwg, 6/13/2012 2:04:14 PM, Adobe PDF.pc3
<br />r
<br />SEE ELECTRICAL
<br />
|