REVISIONS <br />BY <br />GENERAL NOTES <br />DESIGN CRITERIA <br />1. THE STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE WITH THE <br />LOADING CRITERIA OF ASCE 1-10, THE FLORIDA BUILDING CODE, <br />2010 EDITION (BUILDING AND EXISTING BUILDING VOLUMES). <br />2. DESIGN LOADS FOR THE STRUCTURE AND ITS COMPONENTS SHALL <br />BE AS FOLLOWS: <br />FLAT ROOF <br />DEAD LOAD = 20 PSF <br />LIVE LOAD = 20 PSF <br />3. WIND CRITERIA FOR THE STRUCTURE SHALL BE AS FOLLOWS- <br />WIND DESIGN METHOD = ALTERNATE ALL -HEIGHT METHOD. <br />ULTIMATE WIND DESIGN SPEED = 135 MPH (3 SECOND WIND GUST) <br />NOMINAL DESIGN WIND SPEED = 105 MPH. <br />RISK CATEGORY OF STRUCTURE = II. <br />WIND EXPOSURE CATEGORY = 5- <br />WIND ENCLOSURE COEFFICIENT = t 0.18 (ENCLOSED). <br />WIND PRESSURES FOR COMPONENT E CLADDING = REFER TO Slb. <br />4. DEFLECTION LIMITS SHALL BE COORDINATED WITH ARCHITECTURAL <br />DRAWINGS BASED ON MATERIALS SPECIFIED BY THE ARCHITECT. <br />MATERIALS THAT REQUIRE DEFLECTION CRITERIA EXCEEDING <br />CODE LIMITS PER THE MANUFACTURER'S AND/OR ARCHITECT'S <br />SPECIFICATIONS SHALL MEET THE CRITERIA SPECIFIED BY THE <br />MANUFACTURER AND/OR THE ARCHITECT. <br />5. CONTRACTOR SHALL INFORM AND SUBMIT TO THE ENGINEER OF <br />RECORD LOADING INFORMATION FOR ALL EQUIPMENT NOT SHOWN, <br />OR DIFFERING FROM THOSE SHOWN, ON THE CONTRACT DRAWINGS. <br />6. DELEGATE ENGINEERS SHALL ACCOUNT FOR SELF WEIGHT OF <br />STRUCTURE IN DESIGN AS REQUIRED. <br />EXISTING STRUCTURE <br />1. CONTRACTOR SHALL FIELD VERIFY EXISTING DIMENSIONS, <br />ELEVATIONS, AND CONDITIONS PRIOR TO CONSTRUCTION. <br />DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE <br />ENGINEER OF RECORD BEFORE BEGINNING OF WORK <br />2. TEMPORARY SHORING OF EXISTING AND NEW CONSTRUCTION SHALL <br />BE THE CONTRACTOR'S RESPONSIBILITY UNTIL THE STRUCTURE IS <br />COMPLETE AND HAS ATTAINED THE SPECIFIED STRENGTH. <br />SHOP DRAWINGS AND SU5MITTALS <br />I. SHOP DRAWINGS AND SUBMITTALS FOR ALL STRUCTURAL FRAMING, <br />ELEMENTS, COMPONENTS, AND SYSTEMS INDICATED ON THE <br />STRUCTURAL DRAWINGS SHALL BE SUBMITTED AND APPROVED BY <br />THE ENGINEER OF RECORD PRIOR TO CONSTRUCTION. <br />2. SHOP DRAWINGS AND SUBMITTALS SHALL BE REVIEWED BY THE <br />ENGINEER OF RECORD FOR OVERALL COMPLIANCE WITH <br />CONTRACT DOCUMENTS. COMMENTS AND/OR CORRECTIONS <br />MARKED ON SHOP DRAWINGS AND SUBMITTALS SHALL NOT <br />ALLEVIATE THE CONTRACTOR FROM CONFORMANCE WITH THE <br />CONTRACT DOCUMENTS. <br />3. CONTRACT DOCUMENTS SHALL PRESIDE OVER SHOP DRAWINGS <br />AND SUBMITTALS UNLESS APPROVED IN WRITING BY THE ENGINEER <br />OF RECORD. <br />4. SPECIAL ENGINEERING COMPONENTS SUCH AS PRE-ENGINEERED <br />WOOD TRUSSES AND GOLD -FORMED STEEL SYSTEMS SHALL BE <br />PROVIDED BY A DELEGATE REGISTERED PROFESSIONAL <br />ENGINEER IN THE STATE OF FLORIDA WHO SHALL BE THE ENGINEER <br />OF RECORD OF THESE SPECIAL ENGINEERING COMPONENTS PER <br />THEFLORIDA <br />L O <br />RIDA ADMINISTRATIVE CODE SECTION 61G15-30.006. <br />SIGNED AND SEALED DRAWINGS AND CALCULATIONS SHALL BE <br />SUBMITTED FOR REVIEW OF GENERAL CONFORMANCE WITH THE <br />DESIGN CRITERIA SPECIFIED BY THE ENGINEER OF RECORD. <br />51TE WORK <br />1. NO GEOTECHNICAL REPORT WAS PROVIDED TO THE ENGINEER OF <br />RECORD FOR BUILDING FOUNDATION RECOMMENDATIONS BASED <br />ON ACTUAL SOIL CONDITIONS. THE ASSUMED SOIL BEARING <br />PRESSURE = 2000 PSF. <br />2. A COMPLETE SOIL INVESTIGATION SHALL BE CONDUCTED AND <br />COMPLETED BY A REGISTERED GEOTECHNICAL PROFESSIONAL <br />ENGINEER IN THE STATE OF FLORIDA. THE RESULTS SHALL BE <br />PRESENTED TO THE ENGINEER OF RECORD FOR REVIEW IN THE <br />FORM OF A GEOTECHNICAL REPORT. <br />3. NOTIFY THE ENGINEER OF RECORD IMMEDIATELY OF ANY <br />DISCREPANCIES BETWEEN THE ASSUMED SOIL BEARING PRESSURE <br />AND THE ACTUAL SOIL CONDITIONS. CHANGES NECESSARY TO THE <br />CONTRACT DOCUMENTS DUE TO SPECIFIC INFORMATION IN THE <br />GEOTECHNICAL REPORT SHALL BE CONSIDERED ADDITIONAL <br />SERVICES. <br />4. CONTRACTOR SHALL REVIEW THE GEOTECHNICAL REPORT AND <br />MAKE ALL SITE PREPARATION IN ACCORDANCE TO THIS <br />DOCUMENT, <br />5. FILL MATERIAL SHALL BE CLEAN SOIL, FREE OF DEBRIS AND <br />ORGANIC MATERIAL. FILL MATERIAL SHALL BE PLACED IN ONE <br />FOOT LIFTS AND COMPACTED TO A CRITERIA NOT LESS THAN 9590 <br />OF ITS MODIFIED PROCTOR DENSITY. <br />6. CONTRACTOR SHALL COORDINATE ALL BELOW GRADE PIPING <br />ROUTING WITH THE FOUNDATIONS. NO PIPING THROUGH THE <br />FOUNDATIONS SHALL BE ALLOWED. REFER TO CIVIL DRAWINGS FOR <br />MINIMUM PIPING CLEARANCE BELOW THE FOUNDATIONS. <br />1. FOUNDATION WALLS RETAINING SOIL SHALL BE BRACED UNTIL <br />FLOOR SLABS ARE IN PLACE AND HAVE REACHED THEIR <br />SPECIFIED COMPRESSIVE STRENGTH. <br />CAST IN PLACE CONCRETE <br />1. CAST IN PLACE CONCRETE SHALL COMPLY WITH THE <br />REQUIREMENTS OF THE FOLLOWING CODES AND STANDARDS <br />(LATEST EDITIONS): <br />a_ BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE <br />(ACI 318). <br />b. DETAILS AND DETAILING OF CONCRETE REINFORCEMENT (ACI <br />315). <br />c. SPECIFICATION FOR HOT WEATHER CONCRETING (ACI 305). <br />d. SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS <br />(ACI 301). <br />e. CONCRETE REINFORCING STEEL INSTITUTE (CRSI). <br />2. CONCRETE SHALL BE NORMAL WEIGHT UNLESS NOTED OTHERWISE <br />AND SHALL COMPLY WITH ASTM C94 AND THE FOLLOWING: <br />a. PORTLAND CEMENT SHALL CONFORM TO ASTM C150. <br />b. AGGREGATES (3/4" MAX.) SHALL CONFORM TO ASTM C33. <br />c. AIR ENTRAINING AGENT SHALL CONFORM TO ASTM C260. <br />d. WATER REDUCING AGENT SHALL CONFORM t0 ASTM C494. <br />e. FLYASH (2090 MAX.) CLASS F SHALL CONFORM TO ASTM <br />C618-18. <br />f. WATER SHALL BE POTABLE. <br />g. REQUIRED SLUMP RANGE = 3" TO 5"_ <br />3. MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS SHALL BE AS <br />FOLLOWS: <br />SLAB -ON -GRADE = 3000 PSI W/C RATIO = OB5 <br />MASONRY GROUT = 3000 PSI W/C RATIO = 0.55 <br />FOOTINGS = 3000 PSI W/C RATIO = OB2 <br />COLUMNS = 4000 PSI W/C RATIO = 0.45 <br />WALLS = 4000 PSI W/C RATIO = 0.45 <br />BEAMS = 4000 PSI W/C RATIO = 0.45 <br />TIE COLUMNS = 4000 PSI W/C RATIO = 0.45 <br />TIE BEAMS = 4000 PSI W/C RATIO = 0.45 <br />4. REINFORCING STEEL BARS USED SHALL BE DEFORMED BARS <br />GRADE 60 KSI AND SHALL CONFORM TO ASTM Ab15. <br />REINFORCEMENT SHALL BE BENT AND PLACED IN ACCORDANCE <br />WITH CRSI REQUIREMENTS. <br />5. WELDED WIRE FABRIC USED SHALL CONFORM TO ASTM A185 AND <br />SHALL BE FURNISHED IN FLAT SHEETS, NOT ROLLS. MINIMUM MESH <br />LAP SHALL BE (2) PANELS. <br />6. MOISTURE BARRIER USED SHALL BE 6 MIL POLYETHYLENE. <br />MINIMUM LAP At JOINTS SHALL BE 6". <br />I. REINFORCING BAR COVER SHALL BE AS FOLLOWS: <br />FOOTINGS = 3" <br />SLAB ON GRADE = 3" (BOTTOM) P (TOP) <br />COLUMNS AND TIE COLUMNS = 2" (EXTERIOR) 1 )�" (TYPICAL) <br />SHEAR WALLS = 2" (EXTERIOR) 1 ,�" (TYPICAL) <br />BEAMS AND TIE BEAMS = IV, <br />8. CONTACTOR SHALL INSTALL, IN ACCORDANCE WITH CRSI <br />REQUIREMENTS, TIES, SPACERS, CHAIRS, BOLSTERS, ETC <br />NECESSARY TO HOLD REINFORCEMENT SECURELY DURING <br />CONCRETE PLACEMENT. USE PLASTIC TIPS ON ALL EXPOSED <br />SURFACES. <br />9. CONTRACTOR SHALL COORDINATE LOCATION OF ALL OPENINGS, <br />SLEEVES, RECESSES, EMBEDS, ACCESSORIES, ETC PRIOR TO <br />CONCRETE PLACEMENT. NOTIFY ENGINEER OF RECORD OF ANY <br />CONFLICTS WITH REPAR LOCATIONS. NO OPENING OR SLEEVE <br />SHALL BE ALLOWED IN BEAMS OR COLUMNS UNLESS APPROVED <br />BY THE ENGINEER OF RECORD. <br />10. ALL PROPOSED CONSTRUCTION JOINT LOCATIONS SHALL BE <br />SUBMITTED TO THE ENGINEER OF RECORD FOR REVIEW AND <br />APPROVAL PRIOR TO CONCRETE PLACEMENT. <br />11. CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER DESIGN, <br />CONSTRUCTION, SHORING, RESHORING, AND BACKSHORING OF <br />CONCRETE FORMS. DESIGN SHALL BE PERFORMED BY A <br />REGISTERED PROFESSIONAL ENGINEER IN THE STATE OF FLORIDA. <br />12. CONCRETE FORMS SHALL BE COATED WITH COMMERCIAL <br />COMPOUNDS THAT WILL NOT BOND, STAIN, OR ADVERSELY AFFECT <br />THE CONCRETE SURFACES. FORMS SHALL BE WET BEFORE <br />CONCRETE PLACEMENT. CONCRETE FORMS SHALL REMAIN IN <br />PLACE UNTIL TESTING SAMPLES INDICATE THAT CONCRETE HAS <br />ATTAINED A MINIMUM OF 6790 OF THE SPECIFIED COMPRESSIVE <br />STRENGTH AT 28 DAYS. <br />13. REPAIR AND PATCH DEFECTIVE AREAS AND HONEYCOMBS <br />IMMEDIATELY AFTER REMOVAL OF FORMS WITH A HIGH STRENGTH <br />CEMENT MORTAR NOTIFY THE ENGINEER OF RECORD FOR <br />EVALUATION OF EXPOSED REINFORCING IN DEFECTIVE AREAS. <br />14. CONCRETE SHALL BE CURED IN ACCORDANCE WITH ONE OF THE <br />FOLLOWING OPTIONS: <br />a. APPLY A LIQUID MEMBRANE FORMING A CHEMICAL CURING <br />COMPOUND CONFORMING TO ASTM C309. <br />b. PROVIDE CONTINUOUS MOISTURE TO CONCRETE IN <br />ACCORDANCE WITH ACI 301. <br />16. CONCRETE SHALL BE CONSOLIDATED IN PLACE USING INTERNAL <br />VIBRATORS. <br />11. CONCRETE FINISHES (COLOR, CHAMFERING, ETC) SHALL BE PER <br />ARCHITECTURAL DRAWINGS. <br />15. THE FOLLOWING TESTS SHALL BE PERFORMED ON SITE BY A <br />QUALIFIED TESTING LABORATORY AND COPY OF RESULTS SENT TO <br />OWNER, ARCHITECT, ENGINEER OF RECORD, AND CONTRACTOR: <br />a. COMPRESSIVE STRENGTH TESTS IN ACCORDANCE WITH ASTM <br />C39. FOUR LAB -CURED AND FOUR FIELD -CURED CYLINDERS <br />FOR EACH 50 CUBIC YARDS OR FRACTION THEREOF OF EACH <br />CLASS OF CONCRETE PLACED PER DAY. ONE CYLINDER SHALL <br />BE TESTED AT 1 DAYS AND TWO CYLINDERS AT 26 DAYS. THE <br />FINAL CYLINDER SHALL BE RESERVED AND TESTED, IF <br />NECESSARY, WITH PRIOR APPROVAL FROM THE ENGINEER OF <br />RECORD. <br />b. SLUMP TESTS IN ACCORDANCE WITH ASTM C143. <br />19. CAST IN PLACE CONCRETE SUBMITTALS: <br />a. CONCRETE MIX DESIGN SHALL BE SUBMITTED TO THE ENGINEER <br />OF RECORD FOR REVIEW AND APPROVAL PRIOR t0 CONCRETE <br />PLACEMENT. SUBMITTALS SHALL BEAR MIX NUMBER, EXACT <br />LOCATION WHERE MIX WILL BE PLACED IN THE STRUCTURE, AND <br />BACKUP DATA FROM RECENT FIELD AND LAB CYLINDER TESTS. <br />b. DETAILED SHOP DRAWINGS OF REINFORCING BARS INCLUDING <br />NUMBER, SIZE, LOCATION, BAR LISTS AND BEND DIAGRAMS. <br />STRUCTURAL STEEL <br />I. STRUCTURAL STEEL SHALL COMPLY WITH THE REQUIREMENTS OF <br />THE FOLLOWING CODES AND STANDARDS (LATEST EDITIONS): <br />a. STEEL CONSTRUCTION MANUAL, AMERICAN INSTITUTE OF STEEL <br />CONSTRUCTION (AISC). <br />b. ALLOWABLE STRESS DESIGN (ASD), AMERICAN INSTITUTE OF <br />STEEL CONSTRUCTION (AISC). <br />c. AMERICAN WELDING SOCIETY (AWS). <br />2. STRUCTURAL STEEL USED SHALL BE ACCORDING TO "THE <br />SPECIFICATION FOR DESIGN, FABRICATION, AND ERECTION OF <br />STRUCTURAL STEEL FOR BUILDINGS" AS PUBLISHED BY (AISC) AND <br />CONFORMING TO THE FOLLOWING: <br />a. STRUCTURAL WIDE FLANGE (W) SHAPES SHALL CONFORM TO <br />ASTM A992 WITH MINIMUM YIELD STRENGTH (N) = 50 KSI. <br />b. STRUCTURAL TUBING, RECTANGULAR AND SQUARE (HSS), SHALL <br />CONFORM TO ASTM A500 - GRADE B WITH MINIMUM YIELD <br />STRENGTH (N) = 46 KSI. <br />c. STRUCTURAL PIPE, ROUND (HSS), SHALL CONFORM TO ASTM A53 <br />- GRADE B WITH MINIMUM YIELD STRENGTH (Fy) = 42 KSI. <br />d. ANCHOR BOLTS SHALL CONFORM TO ASTM F1554 WITH MINIMUM <br />YIELD STRENGTH (N) = 36 KSI. <br />e. STRUCTURAL STEEL SHAPES, PLATES, CHANNELS, AND ANGLES <br />SHALL CONFORM TO ASTM A36 WITH MINIMUM YIELD STRENGTH <br />(Fy) = 36 KSI. <br />3. UNLESS NOTED OTHERWISE, OPENINGS SHALL NOT BE ALLOWED IN <br />STEEL MEMBERS. <br />4. SPLICES IN STRUCTURAL STEEL MEMBERS SHALL NOT BE ALLOWED <br />UNLESS SHOWN ON APPROVED SHOP DRAWINGS. <br />5. CONTRACTOR SHALL ERECT ALL BEAMS WITH THE NATURAL <br />CAMBER UPWARD. <br />6. BOLTED CONNECTIONS SHALL BE DESIGNED AND FABRICATED TO <br />CARRY 55% OF THE TOTAL LOAD CAPACITY OBTAINED FROM PART <br />2 OF THE (ASD/AISC) "ALLOWABLE UNIFORM LOADS IN KIPS FOR <br />BEAMS LATERALLY SUPPORTED". <br />-I. BOLTED CONNECTIONS SHALL INCLUDE A MINIMUM OF 2 BOLTS. <br />BOLTS USED SHALL BE 3/4" DIAMETER MINIMUM UNLESS NOTED <br />OTHERWISE ON THE DRAWINGS. <br />8. BOLTS AND BOLTED CONNECTIONS SHALL CONFORM TO <br />"SPECIFICATIONS FOR STRUCTURAL JOINTS USING ASTM A325 OR <br />A490 BOLTS". <br />9. WELDS NOT SPECIFIED SHALL BE FILLET WELD WITH THICKNESS <br />EQUAL TO X6" LESS THE LEAST THICK MEMBER ALL WELDS SHALL <br />BE CLEANED AND PAINTED. <br />10. STRUCTURAL STEEL MEMBERS SHALL RECEIVE At LEAST ONE COAT <br />OF SHOP PRIMER PAINT AS PER THE STEEL STRUCTURES PAINTING <br />COUNCIL (SSPC). REFER TO ARCHITECTURAL DRAWINGS AND <br />SPECIFICATIONS FOR PREFERRED COLOR <br />11. NON -SHRINK GROUT SHALL CONFORM TO ASTM C110-1 WITH MIN. <br />COMPRESSIVE STRENGTH OF 6000 PSI, NON -CORROSIVE AND <br />NON-FERROUS. <br />12. THE FOLLOWING TESTS SHALL BE PERFORMED BY A QUALIFIED <br />TESTING LABORATORY AND COPY OF RESULTS SENT TO OWNER, <br />ARCHITECT, ENGINEER OF RECORD, AND CONTRACTOR: <br />a. INSPECT ALL STRUCTURAL STEEL MEMBERS. <br />b. INSPECT VISUALLY ALL BOLTED CONNECTIONS. <br />c. TEST AT LEAST 25% OF BOLTED CONNECTIONS. <br />d. TEST AT LEAST 50% OF FULL PENETRATION WELDS. <br />e. TEST 10096 OF STRUCTURAL STEEL TRUSS CONNECTIONS. <br />13. STRUCTURAL STEEL SUBMITTALS: <br />a. DETAILED SHOP DRAWINGS SHOWING ALL STRUCTURAL STEEL <br />LAYOUTS AND DETAILS, MEMBERS SIZES, STEEL GRADE, <br />BOLTED AND WELDED CONNECTIONS, ETC NECESSARY TO <br />FABRICATE AND ERECT STRUCTURAL STEEL FRAMING. <br />b. DETAILED SHOP DRAWINGS FOR ALL CONNECTIONS NOT SHOWN <br />ON THE CONTRACT DOCUMENTS SIGNED AND SEALED BY A <br />REGISTERED PROFESSIONAL ENGINEER IN THE STATE OF <br />FLORIDA. <br />c. DETAILED SHOP DRAWINGS FOR STEEL STAIRS SIGNED AND <br />SEALED BY A REGISTERED PROFESSIONAL ENGINEER IN THE <br />STATE OF FLORIDA. <br />CONCRETE MASONRY UNITS <br />I. CONCRETE MASONRY UNITS SHALL COMPLY WITH THE <br />REQUIREMENTS OF THE FOLLOWING CODES AND STANDARDS <br />(LATEST EDITIONS): <br />a. BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES <br />(ACI 530 AND TMS 402). <br />In. SPECIFICATION FOR MASONRY STRUCTURES (ACI 530.1 AND TMS <br />602). <br />2. CONCRETE MASONRY UNITS SHALL COMPLY WITH ASTM C90 AND <br />SHALL BE HOLLOW LOAD BEARING CONCRETE MASONRY UNITS <br />WITH THE FOLLOWING MINIMUM PROPERTIES: <br />a. NORMAL WEIGHT, TYPE (I. <br />b. NET AREA COMPRESSIVE STRENGTH OF CONCRETE MASONRY <br />UNITS = 1,900 PSI <br />c_ NET AREA COMPRESSIVE STRENGTH OF MASONRY (F'm) = 1,500 <br />PSI <br />3. MORTAR SHALL BE TYPE M OR S AND SHALL COMPLY WITH ASTM <br />C2-I0. <br />4. GROUT USED IN ALL FILLED CELLS AND MASONRY BEAMS SHALL <br />BE COARSE GROUT AND SHALL COMPLY WITH ASTM C41ro WITH THE <br />FOLLOWING MINIMUM PROPERTIES: <br />a. MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS SHALL BE 3000 <br />PSI. <br />b. MAXIMUM AGGREGATE SIZE SHALL BE 3/s". <br />c. REQUIRED SLUMP RANGE = 8" TO 11". <br />5. PROVIDE 4" x 4" CLEANOUT HOLES IN THE BOTTOM COURSE OF <br />MASONRY FOR EACH GROUT POUR WHEN THE GROUT POUR HEIGHT <br />EXCEEDS 5 FT. REMOVE DEBRIS FROM CLEANOUT HOLES PRIOR TO <br />CAPPING. TOP OF GROUT POUR SHALL BE TERMINATED Y2" BELOW <br />TOP OF MASONRY UNITS TO DEVELOP SHEAR KEY FOR CONTINUED <br />GROUTING. <br />6. CONSOLIDATE GROUT AT THE TIME OF PLACEMENT BY USE OF A <br />LOW SPEED MECHANICAL VIBRATON. RECONSOLIDATE BY A LOW <br />SPEED MECHANICAL VIBRATION AFTER INITIAL WATER LOSS AND <br />SETTLEMENT HAS OCCURRED. <br />-I. MASONRY UNITS CONSTRUCTION SHALL BE PLACED IN RUNNING <br />BOND WITH 3/s" FACE SHELL BEDDING MORTAR JOINTS VERTICALLY <br />AND HORIZONTALLY. <br />8. REINFORCING STEEL BARS USED SHALL BE DEFORMED BARS <br />GRADE 60 KSI AND SHALL CONFORM TO ASTM A615. <br />S. HORIZONTAL REINFORCEMENT SHALL BE LADDER TYPE MASONRY <br />WALL JOINT REINFORCEMENT TYPE DUR-O-WAL (OR EQUIVALENT) <br />AND SHALL COMPLY WITH ASTM A82. HORIZONTAL REINFORCEMENT <br />SHALL BE 9 GAUGE WIRE MINIMUM PLACED AT 16" o.c. MINIMUM LAP <br />LENGTH AT SPLICE SHALL BE b". <br />10. VERTICAL REINFORCEMENT BARS SHALL BE HELD IN POSITION AT <br />TOP AND BOTTOM WITH Y4" MINIMUM CLEARANCE TO THE MASONRY <br />WALLS AND ONE BAR DIAMETER BETWEEN BARS. VERTICAL <br />REINFORCEMENT SHALL EXTEND FROM FOUNDATION TO CONCRETE <br />BEAM OR TIE -BEAM. <br />11. PROVIDE MASONRY CONTROL JOINTS AT LOCATIONS INDICATED ON <br />ARCHITECTURAL DRAWINGS WITH MAXIMUM SPACING OF 34'-0". <br />12. MASONRY CONSTRUCTION SHALL BE INSPECTED IN ACCORDANCE <br />WITH ALL APPLICABLE CODE PROVISIONS. <br />13. CONCRETE MASONRY UNITS SUBMITTALS: <br />a. TYPE OF CONCRETE MASONRY UNITS AND COMPRESSION <br />STRENGTH TEST RESULTS. <br />b. MASONRY GROUT MIX DESIGN SHALL BE SUBMITTED TO THE <br />ENGINEER OF RECORD FOR REVIEW AND APPROVAL PRIOR TO <br />GROUT PLACEMENT. SUBMITTALS SHALL BEAR MIX NUMBER, <br />EXACT LOCATION WHERE MIX WILL BE PLACED IN THE <br />STRUCTURE, AND BACKUP DATA FROM RECENT FIELD AND LAB <br />CYLINDER TESTS. <br />c. DETAILED SHOP DRAWINGS OF REINFORCING BARS INCLUDING <br />NUMBER, SIZE, LOCATION, BAR LISTS AND BEND DIAGRAMS. <br />STEEL 5AR JOISTS AND JOIST GIRDERS <br />1. STEEL BAR JOISTS AND JOIST GIRDERS SHALL COMPLY WITH THE <br />REQUIREMENTS OF THE FOLLOWING CODES AND STANDARDS <br />(LATEST EDITIONS): <br />a. STEEL JOIST INSTITUTE (SJI). <br />b. STANDARD SPECIFICATIONS FOR OPEN WEB STEEL JOISTS. <br />c. STANDARD SPECIFICATIONS FOR LONGSPAN STEEL JOISTS AND <br />DEEP LONGSPAN STEEL JOISTS. <br />d. STANDARD SPECIFICATIONS FOR JOIST GIRDERS. <br />e. CODE OF STANDARD PRACTICE FOR STEEL JOISTS AND JOIST <br />GIRDERS. <br />2. STEEL BAR JOISTS AND JOIST GIRDERS MANUFACTURER SHALL BE <br />A MEMBER OF THE STEEL JOIST INSTITUTE (SJI). <br />3. K-SERIES STEEL BAR JOISTS SHALL BEAR 4" MINIMUM ON <br />MASONRY AND 2,�" MINIMUM ON STEEL U.N.O. <br />4. ROOF STEEL BAR JOISTS AND BRIDGING SHALL BE DESIGNED FOR <br />THE NET ROOF UPLIFT FORCES INDICATED ON THE DRAWINGS <br />DESIGN SHALL BE CARRIED BY A DELEGATE REGISTERED <br />PROFESSIONAL ENGINEER IN THE STATE OF FLORIDA HIRED BY THE <br />STEEL BAR JOISTS AND JOIST GIRDERS MANUFACTURER TO <br />GENERATE SIGNED AND SEALED DOCUMENTS FOR THE DESIGN AND <br />DETAILING. <br />5. STEEL BAR JOISTS BRIDGING SHALL BE PROPERLY INSTALLED <br />PRIOR TO CONSTRUCTION LOADS APPLICATION. <br />6. BOTTOM CHORD CEILING EXTENSIONS SHALL BE PROVIDED WHERE <br />INDICATED ON ARCHITECTURAL DRAWINGS. <br />1 STEEL BAR JOISTS, JOIST GIRDERS AND ALL RELATED <br />ACCESSORIES SHALL RECEIVE ONE SHOP COAT OF PAINT. COLOR <br />SHALL BE AS INDICATED ON ARCHITECTURAL DRAWINGS. <br />8. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE AND WEIGHT <br />OF ALL EQUIPMENT OR UNIQUE LOADS PRIOR TO JOISTS OR <br />GIRDERS FABRICATION. <br />S. STEEL BAR JOISTS AND JOIST GIRDERS SUBMITTALS: <br />a. DETAILED SHOP DRAWINGS INCLUDING LAYOUT OF STEEL BAR <br />JOISTS, JOIST GIRDERS, BRIDGING, CONNECTIONS AND <br />ACCESSORIES. <br />b. SIGNED AND SEALED CALCULATIONS FOR SPECIAL JOISTS <br />(SP-JST) CARRIED OUT BY A DELEGATE REGISTERED <br />PROFESSIONAL ENGINEER IN THE STATE OF FLORIDA SHALL BE <br />SUBMITTED FOR REVIEW OF GENERAL CONFORMANCE WITH THE <br />DESIGN CRITERIA SPECIFIED BY THE ENGINEER OF RECORD. <br />STEEL ROOF DECK <br />1. STEEL ROOF DECK SHALL COMPLY WITH THE REQUIREMENTS OF <br />THE FOLLOWING CODES AND STANDARDS (LATEST EDITIONS): <br />a. STEEL DECK INSTITUTE (SDI) <br />b. AMERICAN WELDING SOCIETY (AWS). <br />2. STEEL ROOF DECK SIZE AND PROFILE SHALL BE AS INDICATED ON <br />THE DRAWINGS AND AS MANUFACTURED BY VULCRAFT (OR <br />EQUIVALENT). <br />3. STEEL ROOF DECK SHALL BE GALVANIZED AND INSTALLED IN (3) <br />SPANS SEGMENTS MINIMUM. <br />4. MINIMUM DESIGN YIELD STRENGTH OF STEEL ROOF DECK SHALL BE <br />Fy = 33 KSI. <br />5. ALL WELD SHALL BE CLEANED, PAINTED AND PERFORMED BY <br />CERTIFIED WELDERS. <br />6. STEEL ROOF DECK SUBMITTALS: <br />a. DETAILED SHOP DRAWINGS INCLUDING LAYOUT, TYPE, <br />FASTENING PATTERN AND ALL ACCESSORIES OF STEEL ROOF <br />DECK <br />COLD -FORMED STEEL STRUCTURAL FRAMING <br />I. COLD -FORMED STEEL STRUCTURAL FRAMING SHALL COMPLY WITH <br />THE REQUIREMENTS OF THE FOLLOWING CODES AND STANDARDS <br />(LATEST EDITIONS): <br />a_ SPECIFICATION FOR THE DESIGN OF GOLD -FORMED STEEL <br />STRUCTURAL MEMBERS (AISI). <br />b. AMERICAN WELDING SOCIETY (AWS). <br />2. MINIMUM DESIGN YIELD STRENGTH OF 20 AND 18 GAUGE SHALL BE <br />Fy = 33 KSI AND SHALL COMPLY WITH ASTM A446, GRADE A. <br />MINIMUM DESIGN YIELD STRENGTH OF 16, 14 AND 12 GAUGE SHALL <br />BE Fy = 50 KSI AND SHALL COMPLY WITH ASTM ,A44(o, GRADE D. <br />3. MEMBERS GALVANIZED FINISH SHALL COMPLY WITH ASTM A525, <br />GbO. <br />4. STANDARD STEEL TRACKS, CLIPS, BRACINGS, BLOCKINGS, LINTELS, <br />WEB STIFFNERS, SCREWS AND ACCESSORIES SHALL BE PROVIDED <br />AS NEEDED PER THE MANUFACTURER'S RECOMMENDATIONS TO <br />COMPLETE THE FRAMING. <br />5. BRIDGING SHALL BE PROVIDED AND INSTALLED AS PER THE <br />MANUFACTURER'S RECOMMENDATIONS. MEMBERS SPLICING SHALL <br />NOT BE PERMITTED. <br />6. COLD -FORMED STEEL STRUCTURAL FRAMING MEMBERS ARE <br />SPECIFIED AS MANUFACTURED BY DIETRICH METAL FRAMING (OR <br />EQUIVALENT). MEMBERS SHALL COMPLY WITH MINIMUM FOLLOWING <br />PROPERTIES: <br />4" 20 GA. CSJ STUDS A = 0211 Ix = 0.699 Sx = 0349 <br />6" 20 GA. CSJ STUDS A = 0346 Ix = 1.808 Sx = 0.603 <br />6" 16 GA. CSJ STUDS A = OBB-I Ix = 2.863 Sx = 0.954 <br />-1. ALL WELD SHALL BE CLEANED, PAINTED AND PERFORMED BY <br />CERTIFIED WELDERS. <br />8. COLD -FORMED STEEL STRUCTURAL FRAMING SUBMITTALS: <br />a. DETAILED SHOP DRAWINGS INCLUDING LAYOUT, FRAME MEMBER <br />SIZE AND SPACING, MATERIAL SPECIFICATIONS AND <br />CONNECTIONS. <br />POST -INSTALLED ANCHORS <br />I. POST -INSTALLED ANCHORS SHALL COMPLY WITH THE <br />REQUIREMENTS OF THE FOLLOWING CODES AND STANDARDS <br />(LATEST EDITIONS): <br />a. QUALIFICATION OF POST -INSTALLED MECHANICAL ANCHORS IN <br />CONCRETE E COMMENTARY (ACI 3552). <br />b. INTERNATIONAL CODE COUNCIL EVALUATION SERVICE (ICC-ES). <br />2. THE SPECIFIED PRODUCTS ARE THE DESIGN BASIS FOR THIS <br />PROJECT. SUBSTITUTION REQUESTS FOR PRODUCTS OTHER THAN <br />THOSE LISTED BELOW MAY BE SUBMITTED BY THE CONTRACTOR <br />t0 THE ENGINEER -OF -RECORD (EOR) FOR REVIEW. SUBSTITUTIONS <br />WILL ONLY BE CONSIDERED FOR PRODUCTS HAVING A CODE <br />REPORT RECOGNIZING THE PRODUCT FOR THE APPROPRIATE <br />APPLICATION. SUBSTITUTION REQUESTS SHALL INCLUDE <br />CALCULATIONS THAT DEMONSTRATE THE SUBSTITUTED PRODUCT IS <br />CAPABLE OF ACHIEVING THE EQUIVALENT PERFORMANCE VALUES <br />OF THE DESIGN BASIS PRODUCT. CONTRACTOR SHALL CONTACT <br />MANUFACTURER'S REPRESENTATIVE FOR PRODUCT INSTALLATION <br />TRAINING AND A LETTER SHALL BE SUBMITTED TO THE FOR <br />INDICATING TRAINING HAS TAKEN PLACE. SPECIAL INSPECTIONS <br />ARE REQUIRED PER THE IBC AND [CC -ES REPORTS. <br />3. FOR ANCHORING INTO CONCRETE <br />a. MECHANICAL ANCHORS SHALL HAVE BEEN TESTED AND <br />QUALIFIED FOR USE IN ACCORDANCE WITH AC13552 AND [CC -ES <br />AC193. PRE -APPROVED ANCHORS INCLUDE: <br />I. SIMPSON STRONG -TIE "TITEN-HD" ([CC -ES ESR-2-113). <br />II. SIMPSON STRONG -TIE "STRONG -BOLT 2" (ICC-ES ESR-3037). <br />b. ADHESIVE ANCHORS SHALL HAVE BEEN TESTED AND QUALIFIED <br />FOR USE IN ACCORDANCE WITH AC1355A AND ICC-ES AC308. <br />PRE -APPROVED ANCHORS INCLUDE: <br />I. SIMPSON STRONG -TIE "SET-XP" (ICC-ES ESR-2508). <br />4. FOR ANCHORING INTO SOLID -GROUTED CONCRETE MASONRY <br />a. MECHANICAL ANCHORS SHALL HAVE BEEN TESTED AND <br />QUALIFIED FOR USE IN ACCORDANCE WITH (CC -ES AC01 OR <br />ICC-ES ACI06. PRE -APPROVED ANCHORS INCLUDE: <br />I. SIMPSON STRONG -TIE "TITEN-HD" (ICC-ES ESR-1056). <br />II. SIMPSON STRONG -TIE "WEDGE -ALL" (ICC-ES ESR-1396). <br />b. ADHESIVE ANCHORS SHALL HAVE BEEN TESTED AND QUALIFIED <br />FOR USE IN ACCORDANCE WITH ICC-ES AC58. PRE -APPROVED <br />ANCHORS INCLUDE: <br />1. SIMPSON STRONG -TIE "SET" (ICC-ES ESR-1112). <br />5. FOR ANCHORING INTO HOLLOW CONCRETE MASONRY <br />a. MECHANICAL ANCHORS SHALL HAVE BEEN TESTED AND <br />QUALIFIED FOR USE IN ACCORDANCE WITH [CC -ES AC106. <br />PRE -APPROVED ANCHORS INCLUDE: <br />I. SIMPSON STRONG -TIE "TITEN-HD". <br />b. ADHESIVE ANCHORS WITH SCREEN TUBES SHALL HAVE BEEN <br />TESTED AND QUALIFIED FOR USE IN ACCORDANCE WITH ICC-ES <br />AC58. THE APPROPRIATE SCREEN TUBE SHALL BE USED AS <br />RECOMMENDED BY THE ADHESIVE MANUFACTURER <br />PRE -APPROVED ANCHORS WITH SCREEN TUBES INCLUDE: <br />I. SIMPSON STRONG -TIE "SET" (ICC-ES ESR-1-1 12). <br />E <br />0 <br />co <br />U <br />L. <br />> <br />0 <br />CO <br />o <br />U U <br />cu <br />N C G.CO <br />O N <br />O U Co <br />Q Iv <br />-- : <br />0 <br />qJ <br />>; N 3 <br />ti <br />a7 N <br />LO <br />m <br />ti <br />ti <br />N <br />ti. <br />0 <br />a <br />SEAL <br />, <br />MOUCHIR <br />S. CHENOUDA <br />PE <br /># 69180 <br />�00M <br />W <br />L+ O co <br />moo <br />N <br />LL <br />Q <br />U <br />is D 00 <br />w <br />;_ N <br />O <br />0 u <br />J <br />W <br />N <br />m ;v <br />Y oo v <br />_ <br />g�2 <br />L� <br />0> <br />6 <br />Q <br />00 <br />W <br />z r! <br />g�v <br />v <br />00 CO <br />Lu <br />ZW <br />,0 (,) Z <br />W ° <br />oJVm� <br />v Q �0 <br />>UW1cr <br />CQU)y <br />N Lu <br />y <br />� L <br />,cC ~ :2 m <br />.� 0 `? N <br />m-o <br />OM <br />JD <br />Date: 06. 12. 12 <br />Scale: AS NOTED <br />Project Mgr: MSC <br />Drawn: <br />Job: 10-61 <br />Sheet <br />sla <br />