My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38021 Market Square (2)
Zephyrhills
>
Building Department
>
Building Plans
>
38021 Market Square (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 10:57:10 AM
Creation date
2/25/2025 9:42:44 AM
Metadata
Fields
Template:
Building Plans
Street #
38021
Location
Market Square
Contractor
Wallace and Associates
Building Plans - Permit #
14023
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
72
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DUCT <br />KEYED NOTES: <br />QI REFER TO THE ARCHITECTURAL DRAWINGS FOR WALL CONSTRUCTION AND RATING, <br />0 THE FIRE DAMPER MANUFACTURER'S INSTALLATION DETAILS AND INSTRUCTIONS AS TESTED AND <br />APPROVED BY U.L. MUST BE USED IN LIEU OF THIS DETAIL WHERE APPLICABLE. <br />Q 165'F FUSIBLE LINK <br />CLEARANCE REQUIREMENTS FOR DAMPER SLEEVES WITHIN A WALL OPENING ARE BASED UPON <br />1/8" PER FOOT OF WIDTH OR HEIGHT UNLESS OTHERWISE NOTED IN THE MANUFACTURER'S <br />INSTRUCTIONS. COORDINATE ALL OPENINGS WITH THE GENERAL CONTRACTOR PRIOR TO <br />INSTALLING THE DAMPER AND SLEEVE. <br />Q5 REFER TO SMACNA, NFPA 90A, AND THE MANUFACTURER'S INSTRUCTIONS FOR SLEEVE <br />GAUGES. <br />CONNECT THE DUCT TO THE SLEEVE WITH AN APPROVED BREAKAWAY -TYPE CONNECTION. <br />AFTER THE SLEEVE HAS BEEN CONNECTED TO THE DUCTWORK WITH THE BREAKAWAY <br />CONNECTION AND THE DUCTWORK 18 PROPERLY SUPPORTED, REMOVE THE CONSTRUCTION <br />SCREWS FROM THE BREAKAWAY CONNECTION, SEAL THE DUCTWORK, AND INSULATE AS <br />REQUIRED. <br />Q SECURE RETAINING ANGLES TO THE SLEEVE ON 6" CENTERS WITH ONE OF THE FOLLOWING <br />METHODS: 1/4" BOLTS AND NUTS, NO. 10 STEEL SCREWS, 1/2" LONG WELDS, OR 3/16" STEEL <br />RIVETS. <br />® THE RETAINING ANGLES (MINIMUM 1-1/2"xl-1/2"x1(o GAUGE) MUST OVERLAP THE STRUCTURAL <br />H SIDES OF WALL (TYP.) OPENING ON ALL FOUR SIDES OF THE SLEEVE AND DAMPER BY A MINIMUM OF ONE INCH AND <br />COVER THE CORNERS OF THE OPENINGS ON BOTH SIDES OF THE RATED WALL. <br />O9 MULTIPLE DUCTS PENETRATING A SECTION OF RATED WALL SHALL HAVE A MINIMUM <br />SEPARATION OF SIX INCHES (6") BETWEEN THE DUCTS. <br />THE ACCESS PANEL SHALL BE INSTALLED FOR THE PRESSURE CLASSIFICATIONS AND <br />CONSTRUCTION STANDARDS REQUIRED AND SHALL BE LARGE ENOUGH TO PERMIT <br />MAINTENANCE AND RESETTING OF THE DEVICES WITH TWO HANDS. PROVIDE TWO ACCESS <br />PANELS IF NECESSARY. THE ACCESS PANEL LOCATION SHALL BE FREE OF OBSTRUCTIONS <br />AND FULLY ACCESSIBLE. <br />AT1405-1214 <br />NOTE: <br />THE MECHANICAL CONTRACTOR SHALL PROVIDE A <br />HONEYWELL AT145-1214 TRANSFORMER, BELIMO <br />LF24-SR-E-US ACTUATOR FOR AN OUTSIDE AIR <br />DAMPER WITH A MINIMUM POSITIONER AND <br />CONNECT TO OUTSIDE AIR DAMPER, AND A <br />HONEYWELL C-1232A/5 SPACE CO2 SENSOR WITH <br />DISPLAY. <br />24 VOLT <br />Oj DYNAMIC FIRE PAMPER (WALL) DETAIL O DEMA1ND CONTROL VENTILATION WIRING IAGFZAM <br />NOT To SCALE NOT TO SCALE <br />IO IORYWELL DETAIL <br />NOT TO <br />24VAC <br />HOT <br />HOT <br />BLACK 24VAC <br />COMM <br />WHITE Yl <br />INPUT <br />GREEN I U <br />ORANGE <br />N/O <br />GREEN <br />YELLOW <br />BROWN <br />OUT - <br />RED 24VAC <br />HOT <br />BLACK 24VAC <br />COMM <br />LF24-5R-E-U5 <br />ACTUATOR FOR OA <br />DAMPER WITH A <br />MINIMUM POSITIONER <br />Cl232,4/B <br />SPACE CO2 SENSOR <br />WITH DISPLAY. <br />REVISIONS <br />BY <br />f� <br />00 <br />00 <br />~~ U CO Ch <br />MN <br />p <br />o� o <br />/ u cd ti U <br />U <br />p • U <br />p � • N i-, <br />E <br />o x <br />�Cn� <br />� G <br />0 <br />N <br />•e <br />w <br />U° O " <br />z w cr,t <br />ARC ►-� <br />O O ul- � <br />'1 t <br />I� <br />� 71 •o <br />TAT®� <br />® E O F- 4rd <br />•° <br />�w <br />oV)Wo � � <br />o - <br />"€ <br />�a <br />0 0m <br />d C Q o <br />m <br />C vv" <br />�L u� <br />C � m <br />C 0 T <br />C O � <br />W E <br />C9 2 <br />U `H <br />yY <br />m <br />UZ <br />U d�C m <br />N <br />Q m n <br />00 m <br />m <br />a <br />m '@ <br />ii s <br />2 <br />MU <br />� V <br />o —� <br />W <br />v J �-- <br />a V Z <br />w W v� <br />—� V <br />C Q V) 0 <br />a VW <br />�LA- <br />0 0 Q �' <br />W0 o <br />v <br />o <br />c I— a <br />�0W�r� <br />M <br />C <br />Oj <br />m Ly <br />Date: 06. 12. 12 <br />Scale: AS NOTED <br />Project Mgr: AAY <br />Drawn: <br />Job: 10-61 <br />Sheet <br />M6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.