Laserfiche WebLink
FURNISHED AND <br />INSTALLED BY <br />ELECTRICAL <br />CONTRACTOR <br />0 <br />r- <br />tV <br />FOUR (4)- <br />ANCHOR BOLTS <br />SUPPLIED WITH <br />POLES. <br />m <br />CONCRETE _3 <br />BASE, POURED <br />IN PLACE BY <br />ELECTRICAL �r 67 <br />CONTRACTOR <br />(FREE OF FORM <br />MAWS) L J <br />I <br />A 2'-4"0 A <br />DENLARGED CROWN DETAIL <br />NOT TO SCALE <br />03 TIES- <br />12" O C_ <br />6% -- <br />VERTICAL <br />L-2-1/2" <br />SECTION <br />A -A <br />SQUARE TAPERED STEEL <br />POLE FINISHED DARK <br />BRONZE POWDER COATED. <br />SEE FIXTURE SCHEDULE <br />AND POLE SPECIFICATION <br />FOR POLE SELECTION_ <br />ACCESS HOLE WITH COVER <br />AND GROUND LUG BEHIND <br />COVER 4 $ <br />BASE COVER <br />CROWN, TOP OF CONCRETE <br />BASE TO SHED WATER <br />INFORCING STEEL <br />SH GRADE <br />-INSTALL CONDUIT BELOW <br />GRADE (MIN_ 3/4" C) <br />3/4"AV-0" COPPER O <br />GROUND ROD (DRIVEN). <br />CONDUIT AND WIRING TO <br />OTHER FIXTURES. <br />POLE t"10UNTED '55' FOLE 3,45E DETA L <br />NOT TO SCALE <br />POLE DETAIL NOTES: O <br />I_ PROVIDE A 21' SQUARE TAPERED STEEL POLE FOR FIXTURE TYPES 55_ THE <br />POLES AND BASE, COMPLETE WITH MOUNTING DEVICE AND LUMINARIES IN <br />PLACE, SHALL BE CAPABLE OF WITHSTANDING A SUSTAINED WIND VELOCITY <br />OF NOT LESS THAN 150 MILES PER HOUR FOR A CATEGORY 2 STRUCTURE PER <br />THE 2010 FBC PROVIDE SIGNED AND SEALED DRAWINGS BY A FLORIDA <br />STATE LICENSED PROFESSIONAL STRUCTURAL ENGINEER <br />2. PROVIDE REQUIRED BRACKET ARM AND ACCESSORIES COMPATIBLE WITH <br />POLE DESIGN. <br />3. PROVIDE GROUND WIRE ATTACHED TO GROUND LUG OR THROUGH BOLT ON <br />BRACKET ARM, AND TO GROUND LUG ON LUMINAIRE. <br />4. STANDARD HANDHOLE WITH METAL COVER ATTACHED WITH STAINLESS STEEL <br />MACHINE SCREWS. MAKE CIRCUIT SPLICES IN THIS HANDHOLE. <br />5_ IF PRE -CAST POLE BASES ARE USED, BACKFILL WITH CONCRETE. 3000 PSI <br />MIN, <br />6. PROVIDE CONDUIT ENTRANCE BELOW GRADE, <br />1. PROVIDE 10 AMP FNQ SLOW BLOW FUSE IN EACH PHASE CONDUCTOR <br />8_ SPLICE GROUND WIRES INSIDE HANDHOLE AND SECURELY BOND GROUND <br />WIRES TO THE POLE AND A CONTINUOUS STEEL BAR IN THE BASE_ <br />s- PROVIDE 3/4 " DIA. X 10'-0" COPPER GROUND ROD AT EACH POLE_ PROVIDE <br />MO AUG, CU BARE GROUND WIRE FROM EACH LUMINAIRE AND BONDED TO <br />GROUND ROD (TYPICAL)_ PROVIDE THE STEEL POLE WITH A 04 AWG STRANDED <br />BARE COPPER CONDUCTOR BONDED TO STEEL BAR IN POLE AND TO <br />GROUND ROD_ <br />ELECTRICAL SIM PLAN <br />SCALE-- 1/16" • P-0" <br />KEYED NOTES <br />DRAWING NOTES <br />I. 120/205 VOLT UTILITY TRANSFORMER <br />COORDINATE SERVICE INSTALLATION WITH <br />UTILITY COMPANY. COORDINATE AID TO <br />CONSTRUCTION COSTS REQUIRED WITH <br />OWNER <br />2, CT METER BASE TO UTILITY COMPANY <br />SPEC, MOUNT TO CONCRETE PYLON <br />ADJACENT TO UTILITY TRANSFORMER <br />3. EXTEND (1) 2"PVC TO STREET FOR INCOMING <br />TELEPHONE SERVICE. COORDINATE EXACT <br />LOCATIONS WITH PHONE COMPANY AND <br />TELECOMM VENDOR <br />4. EXTEND (1) 2"PVC TO STREET FOR INCOMING <br />CATV SERVICE. COORDINATE EXACT <br />LOCATIONS WITH CATV COMPANY AND <br />TELECOMM VENDOR <br />REVISIONS <br />BY <br />�00 <br />00 <br />► M N <br />�w <br />ti <br />o <br />V <br />ti <br />Q � o <br />ti <br />1 <br />�1 <br />1 <br />f <br />w <br />a <br />9t N <br />c � N <br />J <br />W <br />I <br />L- <br />OZ� <br />,J l— <br />a <br />Z <br />UW <br />w vN <br />� <br />-v J U r <br />C Q N O <br />a U W .� LL. <br />_ <br />O <br />} W v �- <br />;�U�L <br />O <br />Cr QZ oN <br />00 <br />W M <br />a)— <br />c C7 <br />p Q� <br />_v <br />J D <br />m L _ <br />Date: 06. 12. 12 <br />Scale: AS NOTED <br />Project Mgr: AAY <br />Drawn: WR <br />Job: 10-61 <br />Sheet <br />ES1 <br />