Laserfiche WebLink
�1 <br />/ <br />1211 <br />L. <br />/ 1 <br />/ <br />/ <br />/ I <br />/ I <br />EX. 4" VTR <br />/ 11211 1 <br />I <br />11 2,� I <br />JIL I <br />I 1 <br />/ <br />211i+�G4G <br />6 i 1 <br />EX. 2" VTR <br />—\11 <br />JIL <br />I 3 <br />I <br />I \ <br />I <br />21 I <br />1211 <br />/ <br />f <br />1 ' \ <br />I ' <br />/' I <br />12" /' 1211 <br />11 211 <br />/ <br />I . / 1 t0 - <br />U 2 <br />i " 2" X. 2" VTR <br />I 12 I I EX. 2" VTR <br />< <br />� 1 JIL JjL <br />/ \ <br />411 \1- -•• I 1 \\ I <br />3„ I 1211 \\\ I <br />EWU-Ill \ \ 211 <br />I / <br />1 1 211 <br />I 1211 \ / <br />211 1 \\v/<� <br />1 <br />I I :2 <br />1 <br />11 11 1L � 11 <br />\\\� 211 ' <br />3„ <br />L / <br />3" <br />WCo- <br />IG-1H <br />Y� <br />PLUMBING KEY NOTES <br />Ol CONNECT NEW 2" VENT PIPING TO EXISTING 2" VENT <br />PIPING ABOVE FIRST FLOOR CEILING. (VERIFY EXACT <br />LOCATION). <br />O2 NEW 2" VENT PIPING UP IN NEW WALL FROM FIRST FLOOR <br />CEILING. <br />O3 CONNECT NEW 2" VENT PIPING TO EXISTING 2" VENT <br />PIPING ABOVE SECOND FLOOR CEILING. (VERIFY EXACT <br />LOCATION). <br />® CONNECT NEW 4" VENT PIPING TO EXISTING 4" VENT <br />PIPING ABOVE FIRST FLOOR CEILING. (VERIFY EXACT <br />LOCATION). <br />O5 NEW 4" VENT PIPING UP IN NEW WALL FROM FIRST FLOOR <br />CEILING. <br />O6 CONNECT NEW 4" VENT PIPING TO EXISTING 4" VENT <br />PIPING ABOVE SECOND FLOOR CEILING. (VERIFY EXACT <br />LOCATION). <br />O CONNECT NEW 2" VENT PIPING TO EXISTING 4" VENT <br />PIPING ABOVE SECOND FLOOR CEILING. (VERIFY EXACT <br />LOCATION). <br />® EXISTING 2" VENT PIPING UP IN EXISTING WALL FROM <br />FIRST FLOOR <br />O9 NEW 4" SANITARY PIPING DOWN TO FIRST FLOOR SEE <br />PARTIAL FIRST FLOOR PLAN. <br />NEW 3" WASTE PIPING DOWN TO FIRST FLOOR SEE <br />PARTIAL FIRST FLOOR PLAN. <br />11 NEW 2" VENT PIPING ABOVE FIRST FLOOR CEILING. <br />12 NEW 4" VENT PIPING ABOVE FIRST FLOOR CEILING. <br />13 CONNECT NEW 4" SANITARY PIPING TO EXISTING 4" <br />SANITARY PIPING BELOW BLAB. (VERIFY EXACT <br />LOCATION). CUT t PATCH FLOOR AS REQUIRED. <br />14 CONNECT NEW 311 WASTE PIPING TO EXISTING 4" <br />SANITARY PIPING BELOW SLAB. (VERIFY EXACT <br />LOCATION). CUT t PATCH FLOOR AS REQUIRED. <br />15 REPAIR EXISTING 2" VENT THRU ROOF. <br />JGI PLUMBING SMITAW RISER - -,ado •........•••'�. <br />SCALE: NONE '���i..__ <br />REVISIONS <br />9Y <br />E <br />o <br />U <br />� U <br />Y to <br />Y co a <br />�w <br />�x E <br />Ew <br />CQ <br />1� o C <br />Q V -0 <br />Q E ti <br />Q m <br />3N <br />" <br />o x X <br />Cn <br />tiN <br />N t` <br />r• <br />✓ ti <br />N <br />1 <br />- a <br />Lu <br />V F Y `Lu <br />o <br />O <br />A <br />C Z 0� <br />C �R� <br />C � <br />W co <br />E" <br />�5 <br />�a <br />U <br />C <br />W <br />>p dm <br />Q ampc <br />g'� <br />.E Q ii R <br />U_ <br />Z L <br />_ 0 <br />J O <br />L v <br />Z 3 <br />J N � <br />N O <br />U 4 _ LL. <br />Q c <br />'?LJJ <br />L <br />v <br />m M 0 �. <br />0 <br />m <br />C Q E 0000 N <br />M <br />O= <br />J <br />Li <br />Date: 02. 09. 11 <br />Scale: AS NOTED <br />Project Mgr: RT <br />Drawn: VK <br />%Job: 10-65 <br />sheet <br />P5 <br />