My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38135 Market Square (6)
Zephyrhills
>
Building Department
>
Building Plans
>
38135 Market Square (6)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 4:23:33 PM
Creation date
2/25/2025 9:44:22 AM
Metadata
Fields
Template:
Building Plans
Street #
38135
Location
Market Square
Contractor
Bobby Hilton Construction
Building Plans - Permit #
14634
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Z <br />MARK <br />MANUFACTURER <br />MODEL NUMBER <br />SIZE <br />CFM <br />NECK <br />LOCATION <br />MATERIAL <br />NOTES: <br />A <br />TITUS <br />TDC <br />24 X 24 <br />SEE PLAN <br />SEE PLAN <br />CEILING <br />ALUMINUM <br />1,2,4 <br />B <br />TITUS <br />r::,C)F= <br />24 X 24 <br />SEE PLAN <br />24 X 24 <br />CEILING <br />4LUMINUI" I <br />2,3,5 <br />4m/im"RND <br />�ir,tcc. SIZE THROW::: /C;FM—/NECK/FLEX CONNECTION SIZE <br />I. PROVIDE MANUAL VOLUME DAMPER AT MAIN TRUNK FOR BALANCING. <br />2. DIFFUSER FINISH SHALL BE OFF-WHITE. <br />3. GRILLE FACE SHALL BE 11/2" x %" EGGCRATE STYLE, <br />4. GRILLE FACE SHALL BE FOUR -GONE TYPE TO MATCH EXISTING ON SITE. <br />5. GRILLE FACE SHALL BE ADJUSTABLE CURVED BLADE. NO STAMPED GRILLES ACCEPTED. <br />AIR 1)I5TIRI5UTION SC,4EDULE <br />SCALE: NONE <br />8 <br />KEYED NOTES: 0 <br />EXISTING DIFFUSER TO REMAIN. BALANCE TO LISTED CFM. <br />EXISTING DIFFUSER TO BE RELOCATED AS INDICATED. VERIFY <br />EXISTING FLEX RUN IS OF SUFFICIENT LENGTH PRIOR TO BID AND <br />REPLACE WITH SAME SIZE AS REQUIRED. <br />Ij I EXISTING DIFFUSER TO BE RELOCATED AS INDICATED. REPLACE <br />EXISTING FLEX WITH NEW. VERIFY SIZE PRIOR TO BID. <br />®NEW LAY- IN TYPE PLENUM RETURN GRILLE. REFER TO AIR <br />DISTRIBUTION SCHEDULE FOR ADDITIONAL INFORMATION. <br />®EXISTING VAV THERMOSTAT TO BE RELOCATED TO THIS LOCATION <br />BY BUILDING CONTROLS COMPANY. COORDINATE WITH THE <br />BUILDING ENGINEER PRIOR TO BID. <br />OMECHANICAL RENOVTION PLAN <br />SCALE: 3/16" = 1'-0" <br />i VAC: GENERAL NOTES <br />I. DUCT SIZES ARE CLEAR INSIDE DIMENSIONS. VERIFY ALL DIMENSIONS <br />AND LOCATIONS PRIOR TO FABRICATION OR INSTALLATION. ALL DUCT <br />SHALL BE CONSTRUCTED AND INSTALLED PER SMACNA <br />REQUIREMENTS. <br />2. ALL NEW FLEXIBLE DUCT CONNECTIONS SHALL BE CLASS ONE TYPE. <br />PROVIDE TAB COLLARS AT MAIN DUCT WITH MANUAL VOLUME DAMPER <br />WITH LOCKING QUADRANT. <br />3. VERIFY THAT EXISTING DIFFUSERS HAVE A MANUAL VOLUME <br />DAMPER INSTALLED AT THE MAIN TRUNK AND PROVIDE IF <br />NOT CURRENTLY INSTALLED. <br />4. HVAC CONTRACTOR SHALL SURVEY SITE PRIOR TO BID <br />SUBMISSION TO FAMILIARIZE HIMSELF WITH EXISTING <br />CONDITIONS. VERIFY EXISTING LOCATIONS AND SIZES <br />INDICATED ON PLANS. <br />5. NEW SPECIFIED DIFFUSER AND RETURNS MATCH EXISTING TYPE <br />AND QUALITY CURRENTLY INSTALLED. ALTERNATE <br />MANUFACTURERS MUST BE APPROVED PRIOR TO BID <br />SUBMISSION. <br />6. DEVIATION FROM MATERIALS, MtTNODS, OR PROCEDURES SET <br />FORTH HEREIN MUST BE APPROVED, IN WRITING, BY ENGINEER <br />PRIOR TO SUBMISSION OF BID, ORDER, FABRICATION OR <br />INSTALLATION. <br />1. ANY AND ALL QUESTIONS AS TO THE INTENT OF OR <br />PROCEDURES SET FORTH IN THESE DRAWINGS MUST BE <br />BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO <br />SUBMISSION OF A BID. LACK OF KNOWLEDGE OR <br />UNDERSTANDING OF THE PLANS SHALL NOT JUSTIFY ANY <br />CLAWS OR ADDITIONAL COMPENSATION. <br />5-INSTALLATION SHALL COMPLY WITH ALL APPLICABLE LAWS, <br />GODES AND ORDINANCES. <br />9. THE MECHANICAL CONTRACTOR SHALL RETAIN THE <br />SERVICES OF AN INDEPENDENT TEST AND BALANCE <br />AGENCY TO TEST AND BALANCE ALL HVAG SYSTEMS AND <br />DEVISES IN THIS PROJECTS SCOPE OF WORK. FINAL VALUES <br />SHALL BE WITHIN TEN PERCENT OF LISTED DESIGN VALUES. <br />SUBMIT REPORT TO THE ARCHITECT AND ENGINEER FOR <br />REVIEW. PROVISIONS SHALL BE MADE FOR ADJUSTMENTS AS <br />DEEMED NECESSARY BY THE ENGINEER. TESTING AGENCY <br />SHALL BE AABC OR NEBB CERTIFIED. <br />i' VAC; LEGEND <br />NEW SUPPLY DIFFUSER <br />NEW CEILING RETURN <br />EXISTING SUPPLY DIFFUSER <br />EXISTING RETURN GRILLE <br />I <br />VOLUME DAMPER <br />NEW RIGID DUCT <br />EXISTING RIGID DUCT <br />NEW CLASS I FLEXIBLE DUCT <br />EXISTING FLEXIBLE DUCT <br />THERMOSTAT <br />PLAN NOTES: <br />I. VAV BOXES ARE EXISTING TO BE REUSED. THE HVAC CONTRACTOR <br />SHALL VERIFY THE OPERATION OF EXISTING VAV'S AND ADVISE THE <br />BUILDING ENGINEER OF ANY REQUIRED DEFIECIENCIES AND/OR <br />MAINTENANCE/REPAIRS REQUIRED. <br />2. DUCTWORK IS EXISTING TO REMAIN. SOME DIFFUSER FLEX RUNS ARE <br />TO BE REMOVED. PATCH OPENINGS PER DETAIL ON SHEET MI <br />UNLESS THIS EXISTING OPENING CAN BE MODIFIED OR EXPANDED <br />TO ACCOMMODATE THE NEW FLEX RUN SHOWN BEING RUN FROM THE <br />AREA OF EXISTING FLEX REMOVAL. <br />REVISIONS <br />BY <br />r � � <br />! 00 <br />U '�D <br />�-• p E, <br />�zti <br />N <br />o ,-U <br />i <br />U N <br />E c <br />rn 0 o <br />3 ti 3 <br />ti <br />--� E o <br />0 <br />ti 0. <br />r <br />N <br />Cn <br />r� <br />1 <br />N � <br />Via':. <br />o / 4 a <br />0 8-1 —13 0 <br />s fE OF <br />0� <br />��y°° <br />�®U�� �� <br />00000 <br />o <br />to M <br />• N <br />N M <br />U 0] p� .- <br />Z m1^ o <br />N � <br />���I � •" C0 Z <br />-�� <br />ON � <br />�oa <br />'01_ooLz <br />0 —Q) L r, <br />J Qmmo <br />CO, <br />z0j+ <br />(0,13 t <br />U N Q) rh <br />Q � O <br />� U <br />a O <br />L <br />o U <br />4..N <br />C qt <br />W Lo <br />m <br />U Z M <br />U_ <br />Cr a <br />o Q� M <br />LLJ <br />�D0 <br />� •— L Li <br />L W —J <br />0� a•-� �; <br />'r <br />z M _ <br />mQ LOr <br />C LLJ M L <br />oo s <br />Mm <br />°OZ <br />•E i N <br />a Li <br />a. <br />Date: 08. 13, 13 <br />Scale: AS NOTED <br />Project Mgr: AAY <br />Drawn: TAF <br />Job: 13-46 <br />Sheet <br />M L <br />