INSTALL WDW. SCREW ANCHOR --I <br />INTO ARCH BLKG. PER <br />INSTALLATION DETAILS <br />BLOCK HEADER <br />1 X 4 FURRING <br />8d NAILS @ 8" O.C. AT BUCK <br />PROVIDE 2 x 8 DIAG. BRACE Bl <br />VERT. BRACES WHEN HGT. OF <br />BRACE EXCEEDS 24" <br />2 x 8 VERT. BRACE(S) <br />BUILT UP PLWD. BUCK - <br />SCRIBE (NOTCH) BACKSIDE <br />TO FIT ARCH CONNECT W/ <br />8d NAILS <br />INSTALL WDW, SCREW--' <br />ANCHOR INTO ARCH BLKG. <br />PER INSTALLATION DETAILS <br />1/4" MAX <br />R SOLID BLKG. AT TOP BTWN. <br />ARCH BLKG. & BUCK --- <br />DOOR JAMB (REFER 1x4 1/2" DRYWALL <br />DOOR JAMB (REFER <br />1x4 1/2" DRYWALL <br />DOOR JAMB (REFER <br />TO PRODUCT <br />1x4 <br />1/2" DRYWALL <br />TO PRODUCT <br />P.T. <br />TO PRODUCT <br />APPROVAL FOR CONN. <br />APPROVAL FOR CONN. <br />APPROVAL FOR CONN. <br />1x4 <br />1 X 4 <br />3-1/4" LONG X 3/16"0 <br />1x4 P.T. <br />FURRING <br />3/16"0 X 3" LONG <br />TAPCONS <br />FURRING <br />(2) ROWS 3/16" x 3-1/2" <br />FURRING <br />TAPCON. INTO <br />STAGGERED @ 16" <br />TAPCON 16" O.C. & 4" <br />2X8 <br />BLOCK@ SPACING „ <br />1 <br />DETAIL <br />O.C. 2-ROWS INTO <br />1x8 P.T. <br />FROM EACH END w/MIN. <br />2" EDGE DIST. ATTACH <br />1X8 <br />PER MANUFACTURE <br />MASONRY THROUGH 1-1/2" DETAIL <br />1x8 w/ (2) ROWS 8d NALS <br />" <br />3 DETAIL <br />1x4 P.T. & 1x8 P.T. <br />STAGGERED @ 12" O.C. <br />3/16" x 3 -1/2" <br />1x4 P.T. <br />DOOR JAMB (REFER <br />TAPCON @ 16" <br />TO PRODUCT <br />O.C. & 4" FROM <br />DOOR JAMB (REFER <br />APPROVAL FOR CONN. <br />YWALL <br />DOOR JAMB (REFER <br />EACH END W/ MIN <br />TO PRODUCT <br />TO PRODUCT <br />2" EDGE DIST. <br />APPROVAL FOR CONN. <br />2x8 P.T. w/ (2) ROWS 3/16" <br />APPROVAL FOR CONN. <br />(2) ROWS 3/16" x 3-1/2 <br />x 3-1/2" TAPCON @ 16"1x4 <br />O.C. & 4" FROM EACH <br />rlx4l/2"DI <br />TAPCON @ 16" O.C. & <br />END w/ MIN. 2" EDGE DIST.FURRIN( <br />4" FROM EACH END w/ <br />2x8 P.T. <br />ATTACH SECOND PLY w/ <br />2x P.T. AS REQ'D <br />MIN. 2" EDGE DIST. <br />(2) ROWS 10dx3" <br />x <br />2x DETAIL <br />2 1/4" <br />DETAIL <br />STAGGERED @ 12" O.C. <br />3-1/4" DETAIL <br />BUILDOUT @ OVER SIZE DOOR -WINDOW ROUGH OPENINGS CC <br />SCALE: N.T.S. SS <br />2x8 P.T. BUCK -CONNECT TO BLOCK <br />W/ 1/4" x 31/4" TAPCON ( 1 1/4" MIN. <br />EMBEDMENT INTO BLK.) <br />1 X 4 FURRING <br />BLOCK HEADER <br />1/2" DRYWALL <br />8d NAILS AT 8" O.C. AT BUCK <br />2 x 8 45^ DIAGONAL (4)10d NAILS INTO <br />BRACE(S) 7/16" OSB 2 x 8 BRACE/ BLKG. <br />BUILT UP PLWD. BUCK ARCH PANEL CUT HOLE IN O.S.B. FOR <br />SCRIBE (NOTCH) POLY -CELL IN THIS AREA <br />BACKSIDE TO FIT ARCH (4)10d NAILS INTO 2 x 8 <br />CONNECT W/ 8d NAILS BRACE/ BLKG. <br />2 x 4 SOLID BLKG. (FULL WIDTH OF WALL) BTWN. OSB <br />ARCH FACES W (4)10d NAILS THRU OSB INTO 2 x 8 <br />A -A PROVIDE TAPCON PER WDW. INSTALLATION DETAILS OR THRU —\ <br />1-1/2" THK. OR MORE BUCK WITHIN 6" MIN. OF START OF ARCH <br />ARCH DETAIL J <br />SCALE: N.T.S. SS <br />2'-0" <br />2 x 8 BUCK - CONNECT TO BLOCK <br />WITH 1/4" x 3 1/4" TAPCON (1 1/4" MIN. <br />/1/4" MAX EMBEDMENT INTO <br />�F SOLID BLKG. AT TOP BTWN. ARCH <br />BLKG. & BUCK <br />2 x 8 VERT. W/ (2) 10d <br />NAILS AT EA. END <br />LEAVE A CUT OUT IN O.S.B. ON T <br />INSIDE TO ALLOW FOR INSULATION <br />TO BE INSTALLED <br />7/16" OSB ARCH PANEL <br />2 x4 SOLID BLKG. (FULL WIDTH OF WALLS) <br />BTWN. OSB ARCH FACES W/ (4) 10d NAILS EQUAL <br />THRU OSB INTO 2 x 8 <br />B-B ARCH DETAIL rK <br />SCALE: N.T.S. SS <br />— SECTION <br />A -A <br />8" <br />1/4" x 3 1/4" TAPCONS <br />LEAVE A CUT OUT IN O.S.B. ON THE <br />INSIDE TO ALLOW FOR INSULATION <br />TO BE INSTALLED <br />2 x 8 45 DIAGONAL BRACE AT EA. <br />FACE OF ARCH W/ (3)10d NAILS <br />AT EA. END <br />PROVIDE TAPCON WITHIN <br />4" MIN. OF BRACE <br />START OF ARC <br />4' MAX. RAID. <br />SECTION <br />B-B <br />8" <br />PROVIDE 2x <br />PROVIDE (2) MIN. CONT. W/ (3) <br />TAPCON AT EA. SIDE 12d NAILS <br />BUCK - (1) WITHIN 4" <br />MIN. OF START OF <br />ARCH <br />START OF ARC <br />EQUAL 4' MAX. RAD. <br />PROPER INSTALLATION MAX. 8" <br />FILL SOLID <br />BOTH CELLS <br />#5 REBj <br />(TYP,) <br />STD. 90' <br />HOOK (1 <br />r 77- <br />t5^ <br />NOTCH WEB AT <br />FIRST 2 COURSI <br />UPLIFT CAPACITY = 805 # FOR 1 STRAP <br />=1610 # FOR 2 STRAPS <br />1 PLY PRE-ENGINEERED TRUSS <br />SIMPSON HM9KT w/ (4)1/4"x1 1/2" SDS <br />SCREWS & (5)1/4" x 21/4" TITEN (IF TRUSS <br />IS 2 PLY INSTALL SIMPSON LGT2 w/ (16) 16d <br />SINKERS AND (7) 1/4"x2 1/4" TITEN = 2150 #) <br />BOND BEAM OR CAST IN PLACE BEAM <br />RETROFIT TRUSS DETAIL <br />N.T.S. <br />2X6 SYP #2 CONT. (MATCH TRUSS DEPTH <br />IF TRUSSES USED) W/ (3) #6 X 4'h" WOOD <br />SCREWS @ 16" O.C. MAX. OR IF MASONRY WALL <br />USE (1) SIMPSON 1/2" HD TITEN (CENTERED) w/ / <br />MIN. 4" EMBEDMENT AT 16" O.C. <br />12 <br />JACK TRUSS PROVIDED BY SEE / <br />TRUSS COMPANY OR PLAN <br />2x6 #2 SYP @ 24" O.C. <br />ROOF SHEATHING ATTACHED ' <br />PER NAILING SCHEDULE ALL <br />(5) 12d NAILS SIMPSON / <br />2X6 TO 2X4 H2.5A w/ (10) <br />8d NAILS <br />/ <br />JACK TRUSS PROVIDED BY <br />TRUSS COMPANY OR 2x4 <br />#2 SYP @ 24" O.C. / <br />4'-0" MAX SEE PLAN 00, <br />2X4 SYP #2 CONT (MATCH TRUSS DEPTH <br />NOTE: <br />SHED ROOF ENDS TO BE <br />GABLE ONLY, CORNERS <br />SHALL NOT BE FRAMED AS <br />HIP. <br />DESIGNED ONLY FOR THE <br />INSTALLATION OF SHINGLE <br />AND METAL ROOF FINISH <br />I <br />GLASS BLOCK INSTALLATION NOTES <br />A) COVER SILL AREA WITH A HEAVY COAT OF ASPHALT EMULSION. ALLOW EMULSION TO DRY <br />AT LEAST 2 HOURS BEFORE PLACING MORTAR. <br />B) ADHERE EXPANSION STRIPS TO JAMBS AND HEAD. MAKE CERTAIN EXPANSION STRIP <br />EXTENDS TO SILL. <br />C) SET A FULL MORTAR BED JOINT, APPLIED TO SILL. <br />D) SET LOWER COURSE OF BLOCK. MAINTAIN A UNIFORM JOINT WIDTH OF 3/8" PLUS OR MINUS <br />1/8". ALL MORTAR JOINTS MUST BE FULL AND NOT FURROWED. ALL MORTAR SHALL BE <br />TYPE "S" OR "N". STEEL TOOLS MUST NOT BE USED TO TAP BLOCKS INTO POSITION. (PLACE <br />EXPANSION STRIP <br />A RUBBER CRUTCH TIP ON END OF TROWEL TO TAP BLOCK INTO POSITION.) DO NOT <br />20 ga. PANEL <br />REALIGN, TAP, OR OTHERWISE MOVE BLOCK AFTER INITIAL PLACEMENT. FOR SOLID GLASS <br />BLOCK IT MAY BE NECESSARY TO USE WEDGES IN THE MORTAR JOINTS OF THE LOWER <br />ANCHOR <br />COURSES TO PREVENT THE MORTAR FROM BEING "SQUEEZED" OUT. <br />1/4" EXPANSION BOLT (2 <br />E) INSTALL PANEL REINFORCING IN EVERY OTHER MORTAR BED HORIZONTALLY AND IN JOINTS <br />9 ga. PANEL <br />PER ANCHOR) <br />IMMEDIATELY ABOVE AND BELOW ALL OPENINGS WITHIN PANELS. (THE SAME SPACING <br />REINFORCING <br />SHALL APPLY TO PANEL ANCHORS WHEN USED AT JAMBS AND HEADS IN LIEU OF CHANNEL <br />(EVERY OTHER <br />OR CHASE SURROUNDS.) RUN REINFORCING CONTINUOUSLY FROM END TO END OF PANELS. <br />COURSE) <br />EXPANSION STRIP <br />LAP REINFORCING NOT LESS THAN 6 INCHES WHENEVER IT IS NECESSARY TO USE MORE <br />THAN ONE LENGTH. DO NOT BRIDGE EXPANSION JOINTS WITH REINFORCING. INSTALL <br />REINFORCING AS FOLLOWS: <br />* PLACE LOWER HALF OF MORTAR IN BED JOINT. DO NOT FURROW. <br />_ <br />SEALANT <br />* PRESS PANEL REINFORCING INTO PLACE. <br />' <br />„ 6 MIN. LAP SPLICE W/ <br />* COVER PANEL REINFORCING WITH UPPER HALF OF MORTAR BED AND TROWEL <br />REINFORCING PANEL <br />SMOOTH. DO NO FURROW. <br />F) PLACE FULL MORTAR BED FOR JOINTS NOT REQUIRING PANEL REINFORCING - DO NOT <br />FURROW. MAINTAIN UNIFORM JOINT WIDTH. <br />6" MIN. LAP <br />G) SET SUCCEEDING COURSE OF BLOCKS. SPACE AT HEAD OF PANEL AND JAMBS MUST <br />SPLICE <br />REMAIN FREE OF MORTAR. <br />NOTE: <br />H) STRIKE JOINTS SMOOTH WHILE MORTAR IS STILL PLASTIC AND BEFORE FINAL SET, AT THIS <br />SEE GLASS BLOCK INSTALLATION NOTES. <br />TIME RAKE OUT ALL SPACES REQUIRING SEALANT TO A DEPTH EQUAL TO THE WIDTH OF THE <br />SEALANT <br />SPACES. REMOVE SURPLUS MORTAR FROM FACES OF GLASS BLOCKS AND WIPE DRY. <br />GLASS BLOCK DETAIL <br />TOOL JOINTS SMOOTH AND CONCAVE, BEFORE MORTAR TAKES FINAL SET. (REMOVE <br />WEDGES FROM LOWER COURSES OF SOLID BLOCKS AND POINT THE VOIDS WITH MORTAR.) <br />GLASS BLOCK SHALL BE INSTALLED PER THE FLORIDA BUILDING CODE RESIDENTIAL SECTION R160 <br />1) AFTER FINAL MORTAR SET (APPROX. 24 HOURS), INSTALL PACKING TIGHTLY BETWEEN <br />GLASS BLOCK PANEL AND JAMB AND HEAD CONSTRUCTION. LEAVE SPACE FOR SEALING. <br />J) APPLY SEALANT EVENLY TO THE FULL DEPTH OF RECESSES IN ACCORDANCE WITH THE <br />MANUFACTURER'S APPLICATION MANUAL AND INSTRUCTIONS. <br />K) A MAXIMUM OF 60 SQUARE FEET OF GLASS BLOCK MAY BE INSTALLED IN ANY OPENING. <br />FOR WIND SPEEDS UP TO 110 MPH*, PER PITTSBURG CORNING RECOMMENDATIONS FOR <br />INSTALLATION OF GLASS BLOCK. <br />IF TRUSSES USED) W/ (2) #6 X 4%," WOOD <br />SCREWS @ 16" O.C. MAX. OR IF MASONRY <br />WALL USE (2) 1/4" X 31/2" TAPCONS AT 16" <br />O.C. <br />SECTION @ ENTRY L <br />SCALE: 3/4" = V-0" SS <br />MASONRY WALL. SEE PLAN FOR <br />REINFORCING. PROVIDE LOWER <br />HOOKED DOWEL <br />W.W.M. AT PERIMETER <br />(1) #5 BARS CONT. WHERE THIS CONDITION <br />TOP WITH MIN. 3" OCCURS <br />COVER 6-0" <br />° <br />C <br />D D II�II—ffF <br />—I I I�TI— <br />o <br />n I�� <br />GRADE <br />M p <br />z <br />&4 �C <br />' (2) #5 REBAR. MIN. 3" <br />16" MIN. 01COVER EA. WAY <br />SECTION AT DEEP MONO FOUNDATION <br />SCALE: 3/4" = V-0" <br />`— FILLED CELL PER <br />FOUNDATION PLAN <br />UNACCEPTABLE INSTALLTION <br />DO NOT DO THIS <br />2"x BOT. PLATE W/ (2) 10d @ 6" O.C. <br />#5 REBAR (TYP) '' <br />kR <br />3/4" PLYWOOD DECKING GLUED <br />AND NAILED W/ 8d COMMON @ <br />6" O.C. EDGES AND 12" O.C. FIELD <br />ATTACHED WALL SHEATHING TO <br />2X BOTTOM PLATE W/ 8d @ 4" <br />O.C., 2 ROWS STAGGERED <br />TD. 90° HOOK (TYP,) <br />/� <br />2x BAND JOIST W/ FACE NAIL 10d <br />@TOP & BTTM CHORD, AND (8) <br />YP•) <br />FACE NAILS 10d @ TRUSS VERT. <br />WEB <br />METAL SEAT PLATE <br />El <br />NOTE: <br />LAP SHEATHING TO <br />BOTTOM OF BAND <br />JOIST TYPICAL <br />' <br />` <br />SIMPSON HGAMIOKTA @ 12" O.C. <br />w/ (4) 1/4x1 1/2" SDS SCREWS <br />NOTC <br />' +2 F� @ FIRST COURSE <br />` <br />THE ' ` <br />:S <br />INTO BAND JOIST & (4) 1/4"x2 3/4" <br />TITEN INTO K.O. BLOCK <br />41## <br />—z <br />FILLED CELL INSTALLATION H <br />RETROFIT FOR MISSING <br />EMBEDDED STRAP <br />SCALE: N.T.S. <br />�SS <br />SEE TYP. 2-STORY WALL SECTION FOR ADDL. <br />INFO SCALE: N.T.S. <br />SEE ARCH PLAN AND <br />PRE-ENG TRUSS DESIGN <br />OCC MIl1TC A oar !l\A! <br />BRG WALL TYPE — — <br />PER PLAN <br />2x2 #2 P.T. MIN, <br />FASTENED PER NOTE <br />2 BELOW <br />CONT 2x4 NAILED TO <br />BLOCKING w/ 2-12d NAILS (**) <br />ALUM DRIP EDGE <br />2x SUB FASCIA <br />' CONT VENTED OR SOLID SOFFIT <br />2x BLOCKING NAILED TO TOP <br />CHORD EVERY OTHER TRUSS <br />w/ 3-12d NAILS, TYP. (**) <br />1. G.C./ BUILDER TO VERIFY/PROVIDE SOFFIT MATERIAL SPAN CAPACITIES BASED <br />ON THE DESIGN PRESSURES SPECIFIED FOR COMPONENTS AND CLADDING <br />LISTED IN THE DESIGN CRITERIA ON SHEET SN. <br />2. 2x2 #2 MIN. P.T. w/ J-CHANNEL SECURED @ 24" O.C. FASTEN TO: <br />- CMU w/ 3" LONG T-NAILS @ 24" O.C. <br />WOOD w/ 0.148"x 3 1/4" @ 16" O.C. <br />3. [F] CHANNEL APPLICATION: 2X2 NOT REQUIRED SEE (PA) INSTALLATION GUIDE <br />STRUCTURAL SOFFIT <br />S FO 1 SCALE: 3/4" = V-0" (**) FOR SOFFITS V-4" & GREATER <br />REV. 02.01.2021 BLOCKING REQUIRED, FOR SOFFITS LESS <br />THAN 1'4" MID BLOCKING NOT REQUIRED <br />*REFER TO THE PRODUCT APPROVAL FOR INSTALLATION DETAILS.* <br />2 X 4 #2 SYP SCAB TO SIDE OF <br />TRUSS AS SHOWN FOR O.H. UP TO Z-6" <br />* DOUBLE 2x4 SCAB FOR 2'-6" TO 4'-0" O.H. <br />X (2)10d NAILS @ 8" O.C. <br />OV�RygN TO TRUSS TOP CHORD <br />CF <br />+ + �C'T/y PLYWOOD SHEATHING <br />+ + <br />+ BLOCKING AS <br />�+. REQUIRED <br />TO SUPPORT <br />TRUSS + SOFFIT <br />2X4 SYP . e s + <br />EACH TRUSS <br />CONNECTOR <br />SEE LINTEL <br />SCHED. <br />CENTER SOFFIT - <br />PRECAST LINTEL <br />SEE ELEVATION <br />FOR OVER HANG <br />(MAX. 4'-0") <br />SECTION @ ROOF EXTENSION M <br />SCALE: 3/4" = V-0" <br />SS <br />OFF 4HFFT nq ANTI <br />SIMPSON HTT4 w/ (18)10d x 1 <br />1/2" NAILS TO STUDS & (1) - <br />5/8" DIA. ALL THREAD ROD <br />EPDXIED w/ SIMPSON "SET" <br />EPDXY MIN. 6" EMBEDMENT E <br />3" MIN, EDGE DISTANCE <br />RETROFIT FOR MISSING MSTAM STRAP <br />SCALE: 3/4" = V-0" <br />z <br />O <br />O <br />w <br />U <br />Cn <br />FILL 1st 4 COURSES <br />SOLID W/GROUT <br />a. <br />FOR OVERHANGS BETWEEN OVER 1 1/2" <br />CONTACT ENGINEER OF RECORD FOR <br />FURTHER INSTRUCTIONS. ' °- <br />OVERHAN <br />° <br />° <br />RETROFIT WALL OVERHANG DETAIL (NTS <br />FOR OVERHANGS BETWEEN 3/4" TO 1 1/2" <br />NOTE: FOR OVERHANGS LESS THAN 314" - NO REPAIR REQ'D. <br />1'-0" 5'-0" <br />ISH F <br />• lyp' Y <br />• ° #5 BAR xx <br />>' ° I> e Q <br />p. 10 • b ° CENTERED W/ g <br />IN TOP o <br />KNOCKOUT / 2.t <br />CHAIR BLOCK <br />MONO FOOTING ' D <br />SIZE AND REINF. PER PLAN A' ", • <br />AND SECTION DETAILS -I <br />CLEAN FILL Ile.o • ' <br />DIRT �' Z <br />,• ° STANDARD o <br />0 99 HOOK N <br />#5 BAR IN <br />FILLED CELL , <br />L, - <br />STEMWALL FOOTING SIZE AND <br />MONO TO STEMWALL FOOTING REINF. AND STEMWALL <br />SECTIONN DDETAETAILS <br />SCALE: 3/4" = V-0" <br />NOTE: IF RETROFIT FILLED CELL CONDITIONS EXCEED (3) PER PROJECT, <br />CONTACT ENGINEER OF RECORD FOR ADDITIONAL INSTRUCTION. <br />EXISTING BOND BEAM. <br />DRILL 3/4"x5" MIN. HOLE SET BAR IN <br />EPDXY CAP TO PREVENT LEAKAGE <br />TOP SPACE BETWEEN EXISTING GROUT & NEW GROUT <br />MUST BE PACKED WITH NON -SHRINK GROUT (USUALLY ± 2") <br />#5x6' EMBEDDED INTO EXISTING BOND BEAM <br />FILL CELL FULL HEIGHT W/ <br />NON SHRINK GROUT. <br />#5x6 EMBEDDED INTO <br />EXISTING FOOTING <br />DRILL 3/4"x5" MIN. HOLE <br />SET BAR IN EPDXY <br />EXISTING FOOTING <br />RETROFIT FILLED CELL DETAIL <br />,I; u=.11-1, rr.r <br />4" SAW CUT <br />A SECTION <br />j SCALE: N.T.S. <br />SCALE: N.T.S. <br />N <br />O <br />N <br />O <br />o <br />�F_W <br />KU'r� �� <br />PGE N S�`s��'. <br />F r , .. <br />w <br />* <br />: Lu <br />' OF t <br />J ' <br />J>>,•'.��ti <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />- <br />0 <br />F W <br />' <br />Q <br />v E r- <br />o o m at <br />N NO LL <br />C <br />m <br />Y <br />gn���`a <br />' N <br />�r� ° Lu - <br />u_ a <br />�i <br />Z <br />o"- <br />—ate O <br />Y' <br />O J <br />7 <br />1 W <br />M <br />��mrn Q< <br />k Z <br />IL <br />N z <br />C0 � rn p <br />6 _ � <br />z <br />oC <br />W <br />00❑ <br />M � <br />Z N M <br />o � <br />10 <br />z g N <br />z g :� <br />J <br />N <br />M <br />Ln <br />z <br />� <br />� o <br />(� <br />w m <br />n <br />V <br />O <br />o <br />V) <br />w <br />�cn <br />U <br />U o N <br />Q <br />N <br />S� <br />ti <br />C <br />W <br />MZ <br />M <br />U_ <br />o <br />„ <br />Q o <br />EU <br />w <br />�o <br />O <br />w= <br />Z <br />Q v <br />Z® <br />ca <br />Q�0 <br />OU <br />6 <br />X <br />&a <br />0 OU <br />o� <br />O <br />N <br />Q Z <br />o <br />W z <br />¢ <br />W <br />L <br />(q <br />C/) <br />Q O <br />z <br />0 Y <br />.0 <br />Z <br />J <br /><m <br />�w <br />co <br />N <br />o_ <br />O <br />wLL <br />¢ U <br />az <br />�w <br />U 3 <br /><o <br />dz <br />�k <br />CD�F <br />J Z <br />>O <br />I� <br />C.0 <br />w¢ <br />o< <br />a <br />°3 <br />0 <br />O <br />= <br />E <br />> L(') <br />0 <br />0) <br />T <br />Cca <br />L <br />� <br />0 <br />d' <br />N <br />Q <br />x <br />> <br />O <br />O <br />�1 <br />L.L <br />0 <br />C: ca <br />O <br />n1 <br />CN <br />r <br />o <br />CN <br />Lid <br />r <br />0) <br />T <br />rn <br />M <br />o <br />c <br />N <br />Z <br />of <br />z <br />:3N <br />E <br />N <br />0 <br />E <br />U _j <br />o <br />Q p <br />JOB <br />NO: <br />21-2030 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />SS <br />I <br />A <br />