HANGER ROD. PROVIDE A SECTION OF HIGH <br />COMPRESSION STRENGTH <br />INSULATION AT EACH HANGER <br />POINT. INSULATION MAY BE <br />HALF ROUND OR FULL ROUND <br />AND EXTEND 2" BEYOND <br />GALVANIZED SHIELD EACH WAY. <br />-------------------- <br />WATER PIPING HANGER <br />THERMAL EXPANSION TANK <br />SUPPORTED FROM STRUCTURE <br />OR ON FLOOR <br />VACUUM RELIEF VALVE <br />CHECK VALVE <br />(TYP) <br />HOT WATER 3 <br />RECIRC PUMP. <br />SEE & DETAIL <br />SCHEDULE <br />4" HIGH GPILV r%IYLLLU <br />PAN W/ DRAIN. <br />ELECTRIC WATER HEATER <br />GALVANIZED <br />SHIELD <br />UNISTRUT <br />CHANNEL <br />CUTOFF VALVE <br />(TYP) <br />-THERMOMETER <br />-UNION <br />(TYP) <br />DRAIN LINE, PIPE FULL <br />SIZE TO FLOOR DRAIN <br />197► <br />IPE <br />SL PRESS. <br />SIZE TO <br />#IN <br />VE <br />WATER HEATER <br />SCHEDULE <br />SYSTEM <br />TYPE <br />NO <br />REQ D <br />MFGR. <br />MODEL <br />N0. <br />EWT <br />LWT <br />STORAGE <br />CAPACITY <br />FLOW <br />B.T.U. <br />REMARKS <br />TANK TYPE <br />E.W.H.-1 <br />ELECT. <br />1 <br />A.O. SMITH <br />DEN-80 <br />60 <br />110 <br />80 GAL. <br />63 GPH <br />N/A <br />LIGHT COMMERCIAL <br />DOMESTIC <br />WATER HEATER <br />THERMAL EXPANSION TANK: <br />AMTROL MODEL ST-12-C, 6.4 GAL TOTAL VOLUME, 12" DIA. x 16" TALL. <br />GENERAL PLUMBING NOTES <br />1. EQUIPMENT AND MATERIALS SPECIFIED AND/OR SHOWN ON DRAWINGS <br />SHALL BE FURNISHED (EXCEPT AS NOTED) COMPLETELY INSTALLED, <br />ADJUSTED, AND SHALL BE LEFT IN A SAFE AND SATISFACTORY <br />OPERATING CONDITION. ALL ACCESSORIES, PARTS, AND CONNECTIONS <br />NECESSARY FOR THE OPERATION OF THE EQUIPMENT SHALL BE <br />FURNISHED AND INSTALLED. <br />2. ALL MATERIALS, EQUIPMENT, AND APPARATUS SHALL BE NEW, EXCEPT ITEMS <br />THAT ARE CALLED FOR AS BEING REUSED OR FURNISHED BY OTHERS. <br />3. ALL EXISTING LOCATIONS ARE TAKEN FROM EXISTING DRAWINGS. IT <br />WILL BE WITHIN THE CONTRACTOR'S SCOPE OF WORK TO VERIFY EXISTING <br />SERVICES AND THE EXACT LOCATION OF PIPES, TO MAKE ALL OFFSETS; <br />AND TO ADD NEW PIPING SYSTEMS TO THE EXISTING PIPING SYSTEMS AS <br />PART OF THE PROJECT CONTRACT. <br />4. CONTRACTOR SHALL CONNECT WATER AND WASTE PIPING TO EQUIPMENT <br />FURNISHED BY THE OWNER OR IN ANOTHER DIVISION OF THIS CONTRACT <br />AS REQUIRED FOR COMPLETE OPERATION. <br />5. MAKE ALL OFFSETS REQUIRED AS PER JOB CONDITIONS. <br />6. CONTRACTOR SHALL COORDINATE AT SITE WITH EXISTING STRUCTURE <br />AND OTHER TRADES BEFORE INSTALLATION OF PLUMBING WORK. <br />7. THE CONTRACTOR SHALL KEEP A SET OF MARKED UP DRAWINGS <br />AS THE JOB PROGRESSES. NO MAJOR CHANGE SHALL BE MADE TO <br />PLUMBING DESIGN/ENGINEERING UNLESS IT HAS BEEN COORDINATED, <br />DRAWN, AND SUBMITTED FOR APPROVAL TO THE ARCHITECT. <br />8. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING <br />PIPING, FIXTURES OR EQUIPMENT DUE TO NEW CONSTRUCTION AND <br />HE SHALL RESTORE EXISTING WORK TO ITS ORIGINAL CONDITION AT NO <br />COST TO THE OWNER. <br />9. ALL PLUMBING WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE FLORIDA <br />BUILDING CODE, 2007 EDITION WITH THE 2009 SUPPLIMENTS AS WELL AS LOCAL <br />ORDINANCES AND IN COMPLIANCE WITH THE ENERGY CONSERVATION CODE. <br />10. CONTRACTOR SHALL FURNISH AND INSTALL SHOCK ABSORBERS ON PIPING <br />SERVING FIXTURES AND EQUIPMENT WITH QUICK CLOSING VALVES. SIZE OF <br />SHOCK ABSORBERS SHALL BE ACCORDING TO PDI STANDARDS. <br />11. CONTINUITY OF SERVICES: EXISTING BUILDING WILL REMAIN IN USE DURING <br />CONSTRUCTION OPERATIONS. WHEN AN INTERRUPTION OF AN EXISTING SERVICE <br />IS NECESSARY, CONTRACTOR SHALL COORDINATE WITH AUTHORIZED HOSPITAL <br />PERSONNEL BEFORE MAKING THE NECESSARY INTERRUPTION. <br />12. ALL PENETRATIONS THROUGH WALLS AND FLOORS SHALL BE SLEEVED <br />AND/OR PATCHED AS DIRECTED BY THE SPECIFICATIONS. PATCHING <br />SHALL MATCH EXISTING FINISH. (SEE ARCH. DRAWINGS). <br />13. CONTRACTOR SHALL PROVIDE TRAP PRIMERS ON ALL NEW FLOOR DRAINS <br />NOT RECEIVING CONSTANT DISCHARGE FROM FIXTURES AND/OR <br />EQUIPMENT, OR AS REQUIRED BY STATE AND LOCAL CODES. <br />14. ALL VENT TERMINALS SHALL BE A MINIMUM OF 25'-0" AWAY FROM A/C AIR <br />INTAKES, WINDOWS AND DOORS. <br />SWEAT TYPE CONNECTION <br />PRESSURE <br />GAUGE W/ <br />PET COCK <br />(TYP) <br />PIPE FROM <br />SYSTEM <br />BALL VALVE <br />(TYP) <br />SUPPORT PUMP AS REQ'D. <br />FROM WALL OR FLOOR <br />IN -LINE <br />PUMP <br />CIRCULATING <br />M OTO R <br />WALL BRACKETS <br />AS REQUIRED <br />PIPE FROM <br />SYSTEM <br />WATER PUMP SCHEDULE <br />IDENTITY <br />SYSTEM TYPE <br />MANUFACTURER / <br />QTY. <br />FLOW <br />H.P. <br />VOLTAGE <br />REMARKS <br />MODEL NO.G.P.M. <br />ELECTRIC <br />ARMSTRONG <br />115 <br />DOMESTIC <br />H.W.R.P.-1 <br />IN -LINE <br />ASTRO <br />1 <br />2 G.P.M. <br />1/25 <br />-1- <br />H.W. RECIRC.. <br />25B0505 T <br />60 <br />PUMP <br />FIXTURE CONNECTION SCHEDULE <br />IDENTITY <br />FIXTURE <br />C. W. <br />H . W. <br />WASTE <br />P-1 <br />WATER CLOSET (PUBLIC - FLOOR MTD. - F.V. - BARRIER FREE) <br />1" <br />- <br />4" <br />P-2 <br />LAVATORY (WALL HUNG - BARRIER FREE - PUBLIC) <br />1/211 <br />1/2" <br />11/4" <br />P-3 <br />PLASTER INTERCEPTOR <br />-- <br />-- <br />11/211 <br />P-4 <br />RELOCATED SINGLE COMPARTMENT SINK <br />1/211 <br />1/2" <br />11/2" <br />P-5 <br />RELOCATED DOUBLE COMPARTMENT SINK <br />1/211 <br />1/211 <br />11/211 <br />P-6 <br />SERVICE SINK <br />1/211 <br />1/211 <br />3" <br />P-7 <br />FLOOR DRAIN (EQUIPMENT ROOMS) <br />-- <br />-- <br />AS NOTED <br />P-8 <br />TRAP PRIMER <br />1/2" <br />-- <br />-- <br />P-9 <br />RELOCATED DRINKING FOUNTAIN (WALL HUNG - DUAL HEIGHT) <br />1/2" <br />1/211 <br />11/411 <br />FIXTURE NOTES: <br />1. ALL WALL HUNG LAVATORIES SHALL HAVE FLOOR MOUNTED LAVATORY CARRIERS WHICH ARE RATED <br />TO WITHSTAND AN APPLIED VERTICAL MINIMUM LOAD OF 250 LBS. ON FRONT OF THE FIXTURE. <br />2. PROVIDE NEW STOPS AND "P" TRAPS FOR ALL RELOCATED FIXTURES IF UNABLE TO RE -USE EXISTING. <br />SEE SPECIFICATIONS FOR MFG. AND MODEL NUMBERS. <br />PLUMBING LEGEND <br />SYMBOL <br />DESCRIPTION <br />SYMBOL <br />DESCRIPTION <br />- <br />COLD WATER <br />BALL VALVE <br />-- <br />HOT WATER <br />BALANCING VALVE (B.V.) <br />— --- <br />HOT WATER RECIRCULATION <br />CHECK VALVE (C.V.) <br />— — ®— — <br />COLD WATER (BELOW FLOOR) <br />E2 <br />EXTERIOR CLEANOUT <br />W <br />WASTE OR SOIL PIPING <br />P-1,ETC <br />FIXTURE INDENTIFICATION <br />— — V— — <br />VENT PIPE <br />- <br />CAP ON END OF PIPE <br />CD <br />CONDENSATE DRAIN <br />19 <br />CONNECTION TO EXISTING <br />01 <br />PIPE TURNED UP <br />PIPE TURNED DOWN <br />PLUMBING ABBREVIATIONS <br />C.W <br />COLD WATER <br />F.D. <br />FLOOR DRAIN <br />H.W. <br />HOT WATER <br />R.P.B.P. <br />REDUCED PRESS. BACKFLOW PREY. <br />H.W.R. <br />HOT WATER RECIRC <br />A.FF <br />ABOVE FINISHED FLOOR <br />V. <br />VENT <br />B.V. <br />BALANCING VALVE <br />W. <br />WASTE <br />T.P. <br />TRAP PRIMER <br />V.T.R. <br />VENT THRU ROOF <br />E.C.O. <br />-EXTERIOR CLEANOUT <br />C.D. <br />CONDENSATE DRAIN <br />C.O. <br />CLEANOUT ABOVE CEILING <br />E.W.H. <br />ELECTRIC WATER HEATER <br />W.C.O. <br />WALL CLEANOUT <br />H.W.R.P. <br />HOT WATER RECIRC PUMP <br />F.C.O. <br />FLOOR CLEANOUT <br />PLUMBING DEMOLITION NOTES <br />1) CONTRACTOR SHALL REMOVE INACTIVE EXISTING SERVICES <br />TO FIXTURES AND EQUIPMENT THAT HAS BEEN OR WILL BE <br />REMOVED TO ALLOW FOR THIS NEW CONSTRUCTION. <br />CONTRACTOR SHALL CAP BELOW FLOORS, SO AS NOT TO <br />INTERFERE WITH NEW ARRANGEMENT OF RENOVATED AREA. <br />2) WHERE EXISTING EQUIPMENT, PLUMBING FIXTURES, AND RELATED <br />ITEMS ARE TO BE REMOVED, CONTRACTOR SHALL SUBMIT COMPLETE <br />LIST TO THE OWNER. ALL ITEMS THAT THE OWNER WISHES TO <br />RTAIN SHALL BE DELIVERED TO BUILDING STORAGE WHERE <br />DIRECTED BY OWNER. ITEMS THAT OWNER DOES NOT WISH TO <br />RETAIN SHALL BE DISPOSED OF LEGALLY. <br />3) CONTRACTOR IS RESPONSIBLE FOR ALL CUTTING AND PATCHING <br />REQUIRED BY HIS WORK. RESTORE FINISHES TO MATCH EXISTING <br />SURFACES IN COLOR, TEXTURE AND APPEARANCE. <br />PLUMBING INDEX <br />SHEET <br />NO. <br />SHEET TITLE <br />P0.1 <br />PLUMBING SCHEDULES, NOTES, LEGENDS, DETAILS AND SHEET INDEX <br />P2.1 <br />UNDERGROUND PLUMBING PLAN - DEMOLITION <br />P2,2 <br />FIRST FLOOR PLUMBING PLAN - DEMOLITION <br />P3.1 <br />UNDERGROUND PLUMBING PLAN - NEW CONSTRUCTION <br />P3.2 <br />FIRST FLOOR PLUMBING PLAN - NEW CONSTRUCTION <br />Project No. 09002.00 <br />Poo 1 <br />$DATE$ $TIME$ $FLEA$ <br />© 2009 BHIPK Architects, <br />