Laserfiche WebLink
'R1-N�IAI�t� <br />GOOF TOP UNT SCHEDULE <br />ROOF TOIL UNu u ^ <br />RTU-1 <br />RTU-2 <br />RTU-3 <br />RTU-4 <br />MANUFACTURER <br />- <br />CARRIER <br />CARRIER <br />CARRIER <br />CARRIER <br />MODEL <br />- <br />50TC-AO&A2A5 <br />50TC-A05A2A5 <br />50TC-AO5A2A5 <br />50TC-A06A2A5 <br />SUPPLY <br />CFM <br />2000 <br />1600 <br />1600 <br />2000 <br />OUTSIDE AIR <br />CFMI <br />100 <br />200 <br />200 <br />100 <br />ENTERING AIR <br />DB/WB <br />18/61 <br />16/61 <br />18/61 <br />18/61 <br />LEAVING AIR <br />D5/W5 <br />56.4/55.8 <br />562/55.5 <br />562/555 <br />56A/55.8 <br />CAPACITY <br />TONS <br />5.0 <br />4.0 <br />4.0 <br />5.0 <br />TOTAL COOLING <br />MBH <br />(01,900 <br />41,600 <br />41b00 <br />61,900 <br />SENSIBLE COOLING <br />MBH <br />41,100 <br />34200 <br />34200 <br />41,100 <br />EXT. S.P. <br />IN. H 20 <br />5" <br />5" <br />5" <br />b" <br />TOTAL S.P. <br />IN. Hp <br />I.DI" <br />1.01" <br />1.01" <br />1.01" <br />ELECTRIC HEAT <br />KWN. <br />1.9/208V. 3P. <br />12.0/208V. 3P. <br />6.5/208V. 3P. <br />12.0/208V. 3P. <br />EVAPORATOR FAN <br />HP/FLA <br />2.4 - 5B <br />12 - 5.1 <br />12 - 5.1 <br />2,4 - 5.5 <br />COMPRESSOR <br />NOJRLA <br />I - 15.6 <br />1 - 13.1 <br />1 - 13.1 <br />1 - 15.6 <br />CONDENSING FAN <br />NO)FLA <br />1 - 1.5 <br />1 - 1.5 <br />1 - 1.5 <br />1 - 1.5 <br />ELECTRICAL DATA <br />V/0 <br />208/23OV. 3P. <br />208/23OV. 3P. <br />208/23OV. 3P. <br />208/23OV. 3P. <br />MCA <br />AMPS <br />33.9 <br />41.9 <br />28.8 <br />453 <br />FUSE/MOCP <br />- <br />40 <br />50 <br />30 <br />50 <br />EFFICIENCY <br />SEER/EER <br />13.0 <br />13.0 <br />13.0 <br />13.0 <br />WE IGHT <br />LBS. <br />1 585 <br />1 565 <br />565 <br />1 586 <br />NOTES <br />PER BELOW <br />1 1-6 1 <br />1-6 <br />1-6 <br />1 1-(0 <br />NOTES: I. HVAC CONTRACTOR SHALL COORDINATE ELECTRICAL DATA WITH ELECTRICAL <br />CONTRACTOR PRIOR TO ORDER OF EQUIPMENT. <br />2. UNIT SHALL HAVE A SINGLE POINT ELECTRICAL CONNECTION. <br />3. PROVIDE MANUFACTURER STANDARD 14" HIGH CURB. <br />4. PERMANENTLY LABEL ALL SYSTEMS WITH THE RTU DESIGNATION. <br />5. PROVIDE FACTORY 0-2596 OUTSIDE AIR HOOD. <br />6. INSTALL FILTERS IN UNIT PRIOR TO START UP AND PROVIDE <br />NEW SET OF FILTERS AT COMPLETION OF CONSTRUCTION. <br />(no 1ROOF-TOF UNIT SCHEDULE <br />SCALE: NONE <br />j <br />j/ <br />ROOFT P UNIT ,4 <br />)RAIN PAN / <br />DUCT <br />FACTORY CURB <br />GASKET 4 WEATHERSEAL <br />REMOVABLE CAP W/ 1/4"RND HOLE <br />DRILLED IN CAP. FOR CLEAN -OUT, <br />VENT OF DRAIN PIPING, <br />TH <br />P-TRAP <br />TT r <br />T= 3" <br />H= 111/2 ROUTE TO NEAREST ROOF DRAIN <br />X= I" OR TO DOWNSPOUT. PROVIDE <br />DRYWELL BENEATH AS REQUIRED. <br />ROOF INSULATION <br />ROOF DECK <br />COUNTERFLASHING <br />STRIP. <br />MARK <br />MANUFACTURER <br />MODEL NUMBER <br />SIZE <br />CFM <br />NECK <br />LOCATION <br />MATERIAL <br />NOTES: <br />A <br />PRICE <br />ASPD <br />24 X 24 <br />SEE PLAN <br />SEE PLAN <br />CEILING <br />ALUMINUM <br />1) <br />B <br />PRICE <br />80 <br />24 X 24 <br />SEE PLAN <br />24 X 24 <br />CEILING <br />ALUMINUM <br />1,2,3 <br />C <br />PRICE <br />ACVD <br />10 X 6 <br />SEE PLAN <br />110 X 6 <br />1 CEILING <br />ALUMINUM <br />1,2,4,5 <br />/400/101RND <br />SIZE THROW CFM J <br />NECK)FLEX CONNECTION SIZE <br />NOTES: <br />1. PROVIDE MANUAL VOLUME DAMPER AT MAIN TRUNK FOR BALANCING. <br />2. DIFFUSER FINISH SHALL BE OFF-WHITE. <br />3. GRILLE FACE SHALL BE 11/2" x 1i2" ALUMINUM CUBE CORE. <br />4. PROVIDE PRE-FAB R-6 INSULATED GRILLE BOX WITH TAB COLLAR <br />5. GRILLE FACE SHALL BE ADJUSTABLE CURVED BLADE, NO STAMPED GRILLES ACCEPTED. <br />101 A« D ISTRI13UTION-5C:HEDULE <br />MARK MANUFACTURER MODEL AREA TYPE C.F.M. R.P.M. SONES S.P. WATTS VOLTS PHASE NOTES <br />EF-1� 3,4,5 COOK-GEMINI GsC-120 TOIL/JAN CEILINCsEXHAl1Si 50 1200 1.1 25 35 120v. 1P='. 1-4 <br />NOTES: <br />I. PROVIDE BACKDRAFT DAMPER <br />2. FACTORY PLUG DISCONNECT. <br />3. EXTEND TO DISCHARGE POINT AS SHOWN ON MI. <br />4. FAN SHALL BE CONTROLLED BY ROOM LIGHT SWITCH. <br />0IFAN SCHEDULE <br />SCALE: NONE <br />HANGER SUPPORTS: - <br />8'O.C. = 0-35" DUCTS <br />6'O.C. = 36 -59" DUCTS <br />INSULATED ROUND FLEXIBLE <br />DUCT (MAX. I6-0" LONG) <br />SUPPORT BOTH ROUND METAL d <br />FLEX DUCT EVERY FOUR FEET <br />WITH 2" 24 GA. STEEL STRAP. <br />?AB COLLAR WITH <br />MANUAL DAMPER <br />INSULATION <br />SUPPLY DUCT RIGID ROUND METAL <br />SADDLE: 22 GAUGE BRANCH DUCT <br />AS APPLICABLE. <br />CEILING CEILING DIFFUSER <br />- HANGER SUPPORTS SHALL BE AS NOTED ABOVE FOR DUCT WIDTHS UP <br />TO 24" AND WITH TRAPEZE HANGERS FOR DUCTS 25" AND ABOVE. <br />J(DI CEILING DIFFUSER RUN -OUT DETAIL <br />ICI)IIRTU,DONDENSATE DETAIL I <br />6' -0" <br />SPACING <br />$CH. 40 PVC <br />EXTRA LAYER OF <br />ROOF INSULATION <br />METAL DECK - <br />PVC PIPE STRAP: FACTORY <br />FABRICATED, FASTENED TO <br />WOOD SUPPORT W/ GALV. <br />WOOD SCREWS <br />SLOPE W/ ROOF <br />11 <br />PRESSURE TREATED BLOCK: <br />MINIMUM 2" THK <br />'PANDUIT' OR 'ZIP' - <br />STRAP OVER INNER <br />CORE OF FLEX. <br />THERMAL INSULATION <br />OVER THE TOP <br />OF THE DIFFUSER <br />(AS APPLICABLE) <br />SUPPLY AIR <br />� <br />F XI 1, � LE BLEUCT D <br />CEILING DIFFUSER <br />CEILING <br />NOTES: <br />- TAPE INNER COIL OF FLEX TO THE DIFFUSER <br />COLLAR TAPE COMPLETELY AROUND TO ASSURE <br />AN AIR TIGHT SEAL OR USE 'ZIP' STRAP <br />AROUND INNER CORE OF FLEX. USE METAL BAND <br />CLAMP WHERE REQUIRED BY LOCAL AUTHORITY. <br />- PULL FLEX INSULATION AND OUTER COVER DOWN <br />OVER GRILLE COLLAR AND SECURE TO GRILLE <br />WITH TAPE ONLY. DO NOT USE STRAP OR <br />OTHER METHOD WHICH WILL COMPRESS INSULATION. <br />- STRETCH FLEX TIGHT BETWEEN DUCT AND DIFFUSER <br />TO AVOID KINKS. SUPPORT EVERY FOUR FEET <br />WITH 2" STEEL STRAP OR OTHER APPROVED HANGER <br />OIROOF CONDENSATE DETAIL J(DI CEILING DIFFUSER DETAIL <br />SCALE: NONE SCALE:NONE I <br />I6 GAUGE BY 2" <br />STAINLESS STEEL <br />STRAP SECURED TO <br />UNIT FRAME WITH 3/4" <br />SCREWS AND TO CURB <br />WITH 211/2" SCREWS. <br />PROVIDE WASHERS <br />BETWEEN SCREWS <br />AND STRAPS, TYP. <br />METAL ROOF DECK <br />WITH STEEL SUPPORTS. <br />(EXISTING) <br />PACKAGED AIR - <br />CONDITIONER <br />NEW CURB ADAPTER <br />J ALTERNATE: SECURE RTU <br />TO CURB WITH "'14 <br />SCREWS WITH WASHERS. <br />PROVIDE THREE PER <br />LONG SIDE AND TWO <br />PER SHORT SIDE. <br />NOTES: - SET PACKAGED AIR CONDITIONER ON CURB ADAPTER <br />AND SECURE AS INDICATED ABOVE WITH AT LEAST <br />THREE STRAPS/SCREWS PER LONG SIDE OF UNIT AND <br />TWO PER SHORT SIDE OF UNIT. <br />- THIS DETAIL IS PROVIDED FOR FLORIDA <br />HURRICANE 146 MPH TIE -DOWN COMPLIANCE. <br />- PROVIDE WASHERS BETWEEN SCREWS/TAPCONS <br />AND STRAPS, TYPICAL. <br />EXISTING ROOF CURB <br />SECURED TO STRUCTURE. <br />- EXISTING CURBS MAY SUPPORT THE NEW CARRIER EQUIPMENT SPECIFIED WITHOUT <br />THE USE OF A CURB ADAPTER THIS MUST BE VERIFIED PRIOR TO BID SUBMISSION. <br />DRTU TIE -DOWN DETAIL <br />SCALE: NONE <br />DCE IL INCH EX,� AUST FAN DETAIL <br />SCALE: NONE <br />EXHAUST DUCT. <br />SEE PLAN FOR SIZE. <br />RUSKIN ELF-6315DXD <br />LOUVER, 18x12. <br />CEILING <br />EXTERIOR WALL <br />REVISIONS <br />BY <br />0 <br />t, CO <br />v-a`D <br />� <br />Q <br />N cG l� U <br />5�ti <br />U <br />O U • N .: <br />E ti <br />Q o <br />- ao 3 <br />ti <br />. <br />0CQ <br />ti U <br />c <br />N <br />1 <br />w <br />as <br />pppp a0000 <br />°°° <br />° e <br />F <br />00o a ° o lb o <br />° 1 <br />° o <br />e <br />° <br />° -2-1 <br />o'0 °° STATEo o <br />6- ORIDoo ` <br />0oo°o <br />°°° <br />o����D00000ppp°° <br />N <br />Lr)m <br />N O <br />Um oC14-t <br />Z o�Z <br />V1M O N U <br />Q O Z n .� <br />L <br />O �v Fn x <br />V)E a <br />a 0� �co <br />J q) <br />M N <br />LLcj��Q <br />=.s. <br />_c CO r <br />C N M <br />, <br />C] N N, C n j <br />U-) o C^ O <br />�N W U <br />d O <br />0 <br />Z <br />w ao <br />-� z <br />..V_ C4 <br />o 0 c a� <br />°oM <br />}JEiLLi <br />-°vV�°00 <br />m'i <br />w <br />m Ld J 0O� <br />L Q <br />` <br />Z <br />m � M Q t CL <br />C � L. <br />tV <br />WZ a <br />0 IV <br />-J <br />Date: 05. 12. 14 <br />Scale: AS NOTED <br />Project Mgr: AAY <br />Drawn: BMD <br />Job: 14-20 <br />Sheet <br />M2 <br />