(\i <br />9 <br />N <br />N <br />0 <br />N <br />01 <br />00 <br />o <br />co <br />0 <br />DIFFUSER, REGISTER AND GRILLE SCHEDULE <br />NOTES: <br />1. UNIT SIZE IS BASED ON AIRFLOW (CFM) AS INDICATED IN THE SCHEDULE BELOW FOR EACH TYPE <br />DESIGNATION. <br />2. THE LISTING OF A PARTICULAR SIZE IN THE SCHEDULE DOES NOT MEAN THAT IT IS ACTUALLY USED <br />ON THIS PROJECT. <br />3. PROVIDE ONLY THOSE UNITS INDICATED BY TYPE AND CFM ON THE PLANS. <br />4. BRANCH DUCT SIZES TO THE DIFFUSERS, GRILLES AND REGISTERS SHALL CONFORM TO THIS SCHEDULE UNLESS NOTED <br />OTHERWISE ON THE PLANS. <br />5. AT THE CONTRACTORS' OPTION, BRANCH DUCTS MAY BE ROUND OR RECTANGULAR. <br />6. FOR ROUND NECK DIFFUSERS THE BRANCH DUCT SIZE SHALL BE EITHER THE NECK SIZE INDICATED OR <br />OR THE EQUIVALENT RECTANGULAR BRANCH SIZE INDICATED. <br />7. FOR SQUARE AND RECTANGULAR DIFFUSERS, GRILLES AND REGISTERS, THE BRANCH DUCT SHALL <br />BE SIZED AS INDICATED, WITH A TRANSITION TO THE ACTUAL NECK SIZE AT THE UNIT. HOWEVER, IF <br />SPACE IS AVAILABLE, THE FULL NECK SIZE MAY BE USED FOR THE ENTIRE BRANCH RUN. <br />8. ROUND BRANCH DUCTS MAY BE USED FOR SQUARE OR RECTANGULAR DIFFUSERS, GRILLES AND REGISTERS <br />PROVIDED A SUITABLE TAPERED TRANSITION IS USED AND THE EQUIVALENT ROUND SIZE FOR <br />THE LISTED BRANCH DUCT SIZE IS USED. <br />9. DUCT SIZES INDICATED ARE THE AIR SIDE OPENING DIMENSIONS. INCREASE SHEET METAL <br />DIMENSIONS AS REQUIRED FOR LINING OR OTHER FACTORS. <br />SERIES:AA <br />MODULAR LOUVERED FACE CEILING DIFFUSER WITH 24"x24" FACE <br />BASED ON TITUS TMS <br />NECK <br />RECTANGULAR <br />MINIMUM <br />MAXIMUM <br />SIZE <br />BRANCH DUCT <br />REMARKS <br />AIRFLOW (CFM) <br />AIRFLOW (CFM) <br />(IN DIA.) <br />(INAN) <br />0 <br />100 <br />6 <br />8x4 <br />105 <br />210 <br />8 <br />10x6 <br />215 <br />370 <br />10 <br />12x8 <br />375 <br />600 <br />12 <br />148 <br />605 <br />900 <br />14 <br />16x10 <br />905 <br />1100 <br />15 <br />18x10 <br />SERIES:FA <br />FIXED BLADE GRILLE, 3/4" SPACING FOR RETURN, EXHAUST OR TRANSFER <br />BASED ON TITUS 350 RL <br />NECK <br />RECTANGULAR <br />MINIMUM <br />MAXIMUM <br />SIZE <br />BRUNCH DUCT <br />REMARKS <br />AIRFLOW (CFM) <br />AIRFLOW (CFM) <br />(in x in) <br />(IN x IN) <br />0 <br />120 <br />6x6 <br />6x6 <br />125 <br />260 <br />8x8 <br />8x8 <br />265 <br />470 <br />10x10 <br />10x10 <br />475 <br />530 <br />12x12 <br />12x10 <br />FRONT BLADE PARALLEL <br />535 <br />730 <br />1414 <br />1410 <br />TO SHORT DIMENSION <br />735 <br />810 <br />16x16 <br />16x10 <br />815 <br />960 <br />18x18 <br />18x10 <br />965 <br />1100 <br />20x20 <br />20x10 <br />1115 <br />1375 <br />2424 <br />2410 <br />1380 <br />1570 <br />30x24 <br />30x10 <br />1575 <br />1690 <br />36x24 <br />30x10 <br />1695 <br />1830 <br />42x24 <br />30x10 <br />1835 <br />2100 <br />48x24 <br />3410 <br />HOT WATER REHEAT COIL SCHEDULE <br />MAX <br />AIR <br />WATER <br />BASIS OF DESIGN <br />COIL SIZE <br />FACE <br />MARK <br />CFM <br />(W'x H") <br />VEL <br />CAPEAT <br />LAT <br />MAX PD <br />FLOW <br />EWT <br />LWT <br />MAX PD <br />MANUFACTURER AND <br />REMARKS <br />FPM <br />(MBH) <br />(OF) <br />(OF) <br />(IN WG) <br />GPM <br />(OF) <br />(OF) <br />(FT) <br />MODEL NUMBER <br />RHC-1 <br />300 <br />14 X 8 <br />700 <br />13.2 <br />55 <br />95 <br />1.0 <br />1.3 <br />160 <br />140 <br />10 <br />EXISTING COIL <br />EQ CLEAN -PROVIDE NEW CONTROL VALVE <br />AND WIRING TO BAS CONTROLLER <br />RHC-2 <br />1,000 <br />18 X 12 <br />700.0 <br />44.0 <br />55 <br />95 <br />1.0 <br />4.4 <br />160 <br />140 <br />10 <br />TRANE TYPE T <br />STORAGE NORTH <br />RHC-3 <br />1,000 <br />18 X 12 <br />700.0 <br />44.0 <br />55 <br />95 <br />1.0 <br />4.4 <br />160 <br />140 <br />10 <br />TRANE TYPE T <br />STORAGE CENTER <br />RHC4 <br />1,000 <br />18 X 12 <br />700.0 <br />44.0 <br />55 <br />95 <br />1.0 <br />4.4 <br />160 <br />140 <br />10 <br />TRANE TYPE T <br />STORAGE SOUTH <br />RHC-5 <br />600 <br />14 X 9 <br />700.0 <br />26.4 <br />55 <br />95 <br />1.0 <br />2.6 <br />160 <br />140 <br />10 <br />TRANE TYPE T <br />MANAGER 118 <br />RHC-6 <br />400 <br />14 X 9 <br />700.0 <br />17.6 <br />55 <br />95 <br />1.0 <br />1.8 <br />160 <br />140 <br />10 <br />TRANE TYPE T <br />CONFERENCE/LIBRARY 115 <br />RHC-7 <br />400 <br />14 X 9 <br />700.0 <br />17.6 <br />55 <br />95 <br />1.0 <br />1.8 <br />160 <br />140 <br />10 <br />TRANE TYPE T <br />NURSE OFFICE 114 <br />RHC-8 <br />1,000 <br />18 X 12 <br />700.0 <br />44.0 <br />55 <br />95 <br />1.0 <br />4.4 <br />160 <br />140 <br />10 <br />TRANE TYPE T <br />WAITING EAST <br />RHC-9 <br />1,000 <br />18 X 12 <br />700.0 <br />44.0 <br />55 <br />95 <br />1.0 <br />4.4 <br />160 <br />140 <br />10 <br />TRANE TYPE T <br />WAITING / RECEPTION 101 <br />RHC-10 <br />500 <br />14 X 9 <br />700.0 <br />22.0 <br />55 <br />95 <br />1.0 <br />2.2 <br />160 <br />140 <br />10 <br />TRANE TYPE T <br />STEREOTACTIC / DEXA <br />RHC-11 <br />500 <br />14 X 9 <br />700.0 <br />22.0 <br />55 <br />95 <br />1.0 <br />2.2 <br />160 <br />140 <br />10 <br />TRANE TYPE T <br />ULTRASOUND 135 <br />RHC-12 <br />500 <br />14 X 9 <br />700.0 <br />22.0 <br />55 <br />95 <br />1.0 <br />2.2 <br />160 <br />140 <br />10 <br />TRANE TYPE T <br />TECHS AREA 129 <br />RHC-13 <br />400 <br />14 X 9 <br />700.0 <br />17.6 <br />55 <br />95 <br />1.0 <br />1.8 <br />160 <br />140 <br />10 <br />TRANE TYPE T <br />PHYSICIAN OFFICE 137 <br />RHC-14 <br />500 <br />14 X 9 <br />700.0 <br />22.0 <br />55 <br />95 <br />1 <br />2.2 <br />160 <br />140 <br />10 <br />TRANE TYPE T <br />VESTIBULES, CORRIDOR <br />SUPPLY DUCT / INSULATED FLEXIBLE <br />_ METAL DUCT DIAMETER'D' <br />o AS INDICATED ON <br />VOLUME a o BRANCH DUCT DRAWINGS <br />DAMPER U- <br />a U) _ <br />BEARING w _ QUADRANT LOCKING LEVER <br />�114�v \ \ <br />45 EXIT TRANSITION Q' \ <br />PROVIDE CORNER PIECES TO ROUND <br />TO CLOSE OPENINGS <br />EA, RA FLOW f `--► <br />SA FLOW <br />TRUNK DUCT - <br />EXHAUST/ RETURN/ SUPPLYAIR <br />DUCT BRANCH DETAIL <br />NO SCALE <br />SQUARE THROAT W RADIUS ELBOW <br />ELBOW WITH <br />VANES <br />(CENTERLINE R = 32 = STD RADIUS) <br />NOTE: DUCTWORK HAS BEEN SHOWN USING SQUARE ELBOWS. RADIUS OR RADIUS <br />WITH VANES MAY BE USED AT CONTRACTOR'S OPTION. <br />NOTE: PROVIDE REQUIRED ELBOWS AND <br />TRANSITIONS TO CONNECT TO <br />BRANCHES. MINIMUM DUCT WIDTH SHALL <br />NOT BE LESS THAN 4". <br />RADIUS ELBOW <br />WITH VANES <br />VOLUME DAMPERS <br />TYPICAL ELBOWS AND SPLITTER DETAIL <br />NO SCALE <br />TRANSITION AS REQUIRED <br />MAXIMUM SLOPE 3:1 <br />REHEAT COIL <br />ACCESS DOOR ON <br />UPSTREAM SIDE <br />OF COIL <br />SEAL ALL <br />PENETRATIONS <br />W <br />AIR FLOW REHEAT COIL DETAIL <br />5 NO SCALE <br />SUSPEND COILS INDEPENDENTLY <br />WITH VIBRATION ISOLATORS <br />FLEXIBLE PIPE <br />CONNECTION <br />STRAINER WITH <br />BLOW DOWN <br />PLUG ONLY <br />SHUT OFF VALVE <br />PRESSURE AND <br />TEMPERATURE <br />TEST PLUG <br />IENDENT <br />CEILING DIFFUSER <br />TYPICAL FLEXIBLE <br />METAL DUCT TO <br />2 CEILING DIFFUSER <br />NO SCALE <br />TR) <br />IF F <br />i/. <br />/_ CEILING <br />ROUND - SQUARE OR <br />RECTANGULAR DUCT <br />AS INDICATED - HARD <br />CONNECTION TO AIR <br />DEVICE <br />- CEILING <br />T- <br />VLtLt1Y� DIFFUSER <br />TYPICAL DUCT TO DIFFUSER CONNECTION <br />NO SCALE <br />Project No. 09005.00 <br />M41 <br />$DATE$ $TIME$ $FILEA$ <br />02012 DH/PK Architects, Inc. <br />