Laserfiche WebLink
w <br />A <br />a <br />a <br />a <br />a <br />! <br />M O <br />Q0 <br />co <br />w <br />QO <br />PLUMBING <br />LEGEND <br />DEMOLITION NOTES <br />NOTE: NOT ALL SYMBOLS SHOWN MAY BE REQUIRED FOR THIS PROJECT <br />1. THE CONTRACTOR SHALL REMOVE ALL PLUMBING FIXTURES, <br />TRIM, CARRIERS, SUPPLIES, PIPING, VALVES, EQUIPMENT, ETC. <br />SYMBOL <br />DESCRIPTION ABBREVIATION <br />SYMBOL <br />DESCRIPTION <br />THAT IS OBSOLETE DUE TO CHANGES IN THE BUILDING. <br />SANITARY SEWER <br />SAN <br />o FD <br />FLOOR DRAIN <br />2. WHERE EXISTING CONDITIONS ARE SHOWN, THEY HAVE BEEN <br />DERIVED FROM AVAILABLE DRAWINGS AND REPRESENT THE <br />— — — — — — — — — <br />VENT <br />V <br />o VTR <br />VENT THRU ROOF <br />ENGINEER'S BEST ESTIMATE OF ACTUAL CONDITIONS BUT HAVE <br />STORM <br />ST <br />o FCO <br />CLEANOUT (FLOOR) <br />NOT IN ALL CASES BEEN VERIFIED BY FIELD INVESTIGATION. <br />- <br />COLD WATER <br />CW <br />o GCO <br />CLEANOUT (GRADE) <br />3. THE CONTRACTOR SHALL NOT ASSUME THAT EXISTING CONDITIONS <br />LPCW <br />"LOW" (STREET) PRESSURE COLD WATER <br />LPCW <br />WCO <br />CLEANOUT (WALL) <br />( <br />SHOWN ON THE DRAWINGS ARE COMPLETE AND ACCURATE <br />REPRESENTATIONS OF THE EXISTING PLUMBING SYSTEMS. THE <br />HPCW <br />"HIGH" (PUMP) PRESSURE COLD WATER <br />HPCW <br />WCO <br />CLEANOUT (WALL) <br />CONTRACTOR SHALL VISIT THE JOB SITE AND BECOME FAMILIAR <br />- - <br />HOT WATER <br />HW <br />WITH THE SITE CONDITIONS BEFORE SUBMITTING A BID. ANY ADDITIONAL <br />(E) / EXIST <br />EXISTING <br />WORK CAUSED DUE TO LACK OF KNOWLEDGE OF EXISTING SYSTEMS <br />- - - <br />HOT WATER RETURN <br />HWR <br />UR <br />URINAL <br />SHALL BE DONE AT NO ADDITIONAL EXPENSE TO THE OWNER. IF <br />FLOW - IN DIRECTION OF ARROW <br />AGREEABLE TO THE OWNER, THE CONTRACTOR CAN ESTABLISH LINE <br />L <br />LAVATORY <br />ITEM COSTS FOR POSSIBLE DEMOLITION ITEMSTHAT ARE UNABLE TO <br />c <br />RISER DOWN (ELBOW) <br />SH <br />SHOWER <br />BE IDENTIFIED WITH REASONABLE INVESTIGATION. <br />RISER UP (ELBOW) <br />S <br />SINK <br />E— <br />RISE OR DROP <br />HB <br />HOSE BIBB <br />BRANCH - TOP CONNECTION <br />� <br />WH <br />WALL HYDRANT <br />.. <br />BRANCH - BOTTOM CONNECTION <br />ES <br />EMERGENCY SHOWER <br />—c-Fo <br />BALANCING VALVE <br />BFP <br />BACKFLOW PREVENTER <br />D-4— <br />SHUTOFF VALVE <br />I.E. <br />PIPE INVERT ELEVATION <br />10 <br />GAS COCK <br />F.F.E. <br />FINISH FLOOR ELEVATION <br />_9 <br />PRESSURE GAUGE <br />T.O.F. <br />TOP OF FOOTER ELEVATION <br />-� <br />SECOND STAGE GAS PRESSURE REGULATOR <br />B.O.F. <br />BOTTOM OF FOOTER ELEVATION <br />—— <br />PRESSURE REDUCING VALVE <br />OFCI <br />OWNER FURNISHED <br />RELIEF OR SAFETY VALVE <br />CONTRACTOR INSTALLED <br />A <br />SOLENOID VALVE <br />C <br />LIMIT OF REMOVAL / DEMOLITION <br />C>+ <br />VALVE IN RISER <br />NEW TO EXISTING <br />CAP <br />PIPING TO BE REMOVED <br />—��— <br />UNION <br />X <br />PLUMBING DETAIL / RISER NUMBER <br />XX <br />DRAWING NUMBER <br />GENERAL NOTES <br />1. THE FOLLOWING NOTES ARE GENERAL IN NATURE AND PERTAIN TO <br />THE ENTIRE PROJECT. WHERE THERE ARE EXCEPTIONS, ADDITIONS, <br />OR REVISIONS TO THESE NOTES SUCH EXCEPTIONS, ADDITIONS OR <br />REVISIONS ARE SO NOTED ON THE PARTICULAR DRAWING THEY OCCUR. <br />2. PIPING IS SHOWN IN SCHEMATIC FORM. <br />ALL WORK SHALL BE COORDINATED WITH ALL TRADES INVOLVED. <br />3. REFER TO ARCHITECTURAL PLANS FOR LOCATION OF ALL EQUIPMENT. <br />4. ACCESS PANELS SHALL BE PROVIDED, WHERE REQUIRED, <br />TO SERVICE VALVES AND OTHER MECHANICAL EQUIPMENT. <br />5. ALL VALVES IN CORRIDORS SHALL BE LOCATED 1'- 0" AWAY <br />FROM WALLS CLEAR OF SOFFITS UNLESS NOTED OTHERWISE. <br />6. STORM AND SANITARY PIPING 3" AND LARGER SHALL BE <br />SLOPED AT 1/8" PER FOOT UNLESS NOTED OTHERWISE. <br />7. VERIFY ALL EQUIPMENT CONNECTIONS WITH MANUFACTURERS <br />CERTIFIED DRAWINGS. FIELD VERIFY AND COORDINATE ALL <br />DIMENSIONS PRIOR TO FABRICATION. <br />8. FIELD VERIFY ALL EXISTING CONDITIONS DURING DEMOLITION <br />AND REROUTE PIPING CONFIGURATIONS AS NECESSARY. <br />9. UNLESS NOTED OR OBVIOUS OTHERWISE, PIPE RUNS SHOWN <br />OCCUR IN THE CEILING SPACE OF THE LEVEL INDICATED ON PLANS. <br />DRAWING INDEX <br />SHEET <br />NUMBER TITLE <br />PP.1 <br />PLUMBING LEGEND, NOTES & SCHEDULES <br />PDA <br />PLUMBING DEMOLITION PLAN - UNDERSLAB <br />PD.2 <br />PLUMBING DEMOLITION PLAN - GROUND FLOOR <br />PUA <br />PLUMBING PLAN - UNDERSLAB <br />PS.1 <br />PLUMBING PLAN - GROUND FLOOR <br />PLUMBING FIXTURE CONNECTION SCHEDULE <br />SYMBOL <br />DESCRIPTION <br />FIXTURE / FITTING <br />FLUSH VALVE / FAUCET <br />STRAINER / DRAIN / TRAP <br />SUPPLY STOP(S) <br />SUPPORTS <br />WASTE <br />TRAP <br />VENT <br />CW <br />HW <br />REMARKS / OPTIONS <br />WC-1 <br />WATER CLOSET - ADA COMPLIANT <br />AMERICAN STANDARD "FLOWISE" #3461.001 <br />ZURN Z6000AV.WS1 <br />4" <br />INTEGRAL <br />2" <br />1" <br />--- <br />L-1 <br />LAVATORY - ADA COMPLIANT <br />AMERICAN STANDARD "LUCERNE #0356.015 <br />T & S BRASS #13-0865-04 <br />McGUIRE #155A / #138912 <br />McGUIRE #2165CCLK <br />ZURN #Z1231 <br />2" <br />12" X 12" <br />2 <br />2" <br />2" <br />TRUEBRO LAV-GUARD MODEL #102 <br />S-1 <br />SINK <br />ELKAY LR-1720-3 (14" X 14" X 7Y8") <br />T & S BRASS #13-0865-04 <br />ELKAY LK-35 / McGUIRE #68912 <br />McGUIRE #2165CCLK <br />SELF RIMMING <br />2" <br />1 2" X 12" <br />2" <br />2" <br />" <br />FCO <br />FLOOR CLEANOUT <br />ZURN #ZN-1400 CAST IRON WITH POLISHED NICKLE BRONZE TOP <br />SEE PLANS <br />--- <br />--- <br />-_ <br />--- <br />CO <br />CLEANOUT <br />ZURN #ZN-1400 CAST IRON CLEANOUT WITH FERRULE PLUG <br />SEE PLANS <br />--- <br />--- <br />--- <br />--- <br />SA <br />SHOCK ARRESTOR <br />PPP INC. SC SERIES <br />--- <br />-_ <br />--- <br />-_ <br />-- <br />INSTALL IN UPRIGHT POSITION <br />U <br />C <br />U) <br />4- J <br />N <br />Q <br />N <br />N 4 <br />co <br />i <br />CD Q� <br />N� N <br />U <br />_O Cn <br />•- cc � o <br />0- L aU <br />aD o v <br />0) `L rn o <br />2 E2a,z <br />_ N <br />U �' N vi <br />� <br />NLL <br />co <br />dJ <br />0 <br />m <br />wN <br />cn <br />O <br />� I <br />Q O a <br />3 <br />m <br />o` <br />U) <br />L`- <br />0- <br />^ <br />W <br />N <br />cz <br />Lu Q <br />O <br />C) <br />Tw CZ <br />i <br />rU o o <br />LL <br />06 <br />U) <br />w <br />�-- (3) <br />O <br />z a) <br />U <br />z <br />w a <br />r <br />r <br />w <br />�C/( <br />(� tV <br />V <br />z m <br />m o <br />U) <br />:D CI- <br />E <br />Project No. 09005.00 <br />$DATE$ $TIME$ $FILER$ <br />02012 BWPK Architects, Inc. <br />