Laserfiche WebLink
STRUCTURAL NOTES: <br />GENERAL: DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE TYPICAL AND APPLY TO <br />SIMILAR SITUATIONS ELSEWHERE, EXCEPT AS OTHERWISE INDICATED. ADAPT REQUIREMENTS OF <br />DETAILS, SECTIONS, PLANS, AND NOTES AT LOCATIONS WHERE CONDITIONS ARE SIMILAR. <br />STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH PROJECT SPECIFICATIONS AND <br />ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, AND SITE DRAWINGS. CONSULT THESE <br />DRAWINGS FOR SLEEVES, DEPRESSIONS, AND OTHER DETAILS NOT SHOWN ON THE STRUCTURAL <br />DRAWINGS. <br />CONTRACTOR SHALL LOCATE ALL BURIED UTILITY PIPES PRIOR TO EXCAVATION FOR BUILDING <br />FOUNDATIONS. THE STRUCTURAL ENGINEER SHALL BE NOTIFIED OF POTENTIAL CONFLICTS <br />BETWEEN FOUNDATIONS AND BURIED UTILITY PIPES. <br />CODE REQUIREMENTS: THE BUILDING STRUCTURE IS DESIGNED IN ACCORDANCE WITH THE 2004 <br />EDITION OF THE FLORIDA BUILDING CODE. FOLLOW ALL APPLICABLE PROVISIONS FOR ALL PHASES <br />OF CONSTRUCTION. <br />TEMPORARY CONDITIONS: THE STRUCTURAL INTEGRITY OF THE COMPLETED STRUCTURE <br />DEPENDS ON INTERACTIONS OF VARIOUS CONNECTED COMPONENTS. PROVIDE ADEQUATE <br />BRACING, SHORING, AND OTHER TEMPORARY SUPPORTS AS REQUIRED TO SAFELY COMPLETE THE <br />WORK. THE STRUCTURE SHOWN ON THE DRAWINGS HAS BEEN DESIGNED FOR STABILITY UNDER <br />FINAL CONFIGURATION ONLY. <br />EXISTING CONDITIONS: ALL EXISTING CONDITIONS, DIMENSIONS, AND ELEVATIONS SHALL BE FIELD <br />VERIFIED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY SIGNIFICANT DISCREPANCIES <br />FROM CONDITIONS SHOWN ON THE DRAWINGS. <br />EXISTING STRUCTURE: INFORMATION SHOWN FOR THE EXISTING STRUCTURE ON THESE <br />DRAWINGS WAS TAKEN FROM THE DRAWINGS ENTITLED: EAST PASCO MEDICAL CENTER, DATED: <br />1982. WORK SHOWN ON THESE PLANS ASSUMES THAT THE ORIGINAL CONSTRUCTION WAS <br />PERFORMED IN ACCORDANCE WITH THE ABOVE INDICATED ORIGINAL DRAWINGS INCLUDING (BUT <br />NOT LIMITED TO) DIMENSIONS, ELEVATIONS, MEMBER SIZES, MATERIALS, SECTIONS, DETAILS, ETC. <br />IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE CONDITIONS RELATING TO <br />THE EXISTING STRUCTURE AND TO NOTIFY THE ENGINEER IMMEDIATELY OF ANY DISCREPANCIES <br />OR CONFLICTS. <br />EXERCISE EXTREME CARE AND CAUTION WHEN EXCAVATING AND FILLING ADJACENT TO EXISTING <br />STRUCTURES. UNDER NO CIRCUMSTANCES SHALL THE STRUCTURAL INTEGRITY OF THE EXISTING <br />STRUCTURES BE IMPAIRED IN ANY WAY BY CONSTRUCTION OPERATIONS AND PROCEDURES. DO <br />NOT EXCAVATE OR DISTURB SOIL ADJACENT TO OR BENEATH EXISTING FOOTINGS. <br />DEMOLITION: THE CONTRACTOR IS REQUIRED TO PROVIDE ALL TEMPORARY SCAFFOLDING, <br />PLATFORMS, BARRICADES, RAILINGS, SCREENING, ETC. NECESSARY TO PROTECT EXISTING <br />FACILITIES, STRUCTURES AND THE PUBLIC DURING DEMOLITION AND ERECTION OF THE NEW <br />CONSTRUCTION, AS WELL AS, FOR JOB SAFETY. JOB SAFETY, CONSTRUCTION AND DEMOLITION <br />PROCEDURES ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR IS <br />REQUIRED TO TAKE ALL PRECAUTIONS TO MINIMIZE VIBRATION, NOISE, DUST AND DEBRIS IN ALL <br />AREAS ADJACENT TO AREAS OF DEMOLITION. <br />THE CONTRACTOR IS REQUIRED TO PERFORM HIS WORK IN A MANNER WHICH WILL NOT CONFLICT <br />WITH ANY OPERATION WHICH IS TO REMAIN FUNCTIONAL DURING THE COURSE OF THE PROJECT, <br />UNTIL SUCH OPERATION IS SCHEDULED TO BE SHUT DOWN. <br />AT ALL LOCATIONS WHERE NEW CONSTRUCTION WILL INTERFACE WITH EXISTING ELEMENTS, CUT <br />THROUGH EXISTING STRUCTURE IN STRAIGHT AND TRUE LINES TO INSURE A NEAT INTERFACE. <br />AT ALL LOCATIONS WHERE THE DEMOLITION OF A CONCRETE MEMBER LEAVES THE ENDS OF <br />REINFORCING STEEL EXPOSED, PROVIDE THE FOLLOWING: <br />CHIP CONCRETE FROM AROUND THE STEEL TO A DEPTH OF 1". <br />CUT OFF REINFORCING STEEL NOT LESS THAN 3/4" BELOW THE CONCRETE SURFACE. <br />FILL THE CAVITY FLUSH WITH A HIGH MODULUS GEL EPDXY. SEE SPECIFICATIONS FOR <br />ACCEPTED MANUFACTURERS. <br />BEFORE DEMOLISHING ANY STRUCTURAL ELEMENT, INSTALL ALL REQUIRED TEMPORARY AND/OR <br />PERMANENT BRACING AND SUPPORTS. <br />UPON COMPLETION OF NEW CONSTRUCTION UNDER EACH PHASE, ALL DEMOLISHED AREAS SHALL <br />BE RESTORED TO ACCEPTABLE USAGE ACCORDING TO THE CONTRACT DOCUMENTS AS <br />DETERMINED BY THE A/E. <br />REMOVE COMPLETELY FROM THE SITE AND LEGALLY DISPOSE OF ALL DEBRIS GENERATED BY THE <br />DEMOLITION WORK AS THE WORK PROGRESSES. STOCKPILING OF DEBRIS AND BURNING OF <br />DEBRIS ON AIRPORT PREMISES IS STRICTLY PROHIBITED. <br />ASSUMED FUTURE CONSTRUCTION: <br />VERTICAL: NONE <br />HORIZONTAL: NONE <br />DESIGN CRITERIA: DESIGN WAS BASED ON STRENGTH AND DEFLECTION CRITERIA OF THE 2004 <br />FLORIDA BUILDING CODE. IN ADDITION TO THE DEAD LOADS, THE FOLLOWING LOADS AND <br />ALLOWABLES WERE USED FOR DESIGN, WITH LIVE LOADS REDUCED PER FBC: <br />ROOF: 20 PSF LL 20 PSF SDL <br />FLOORS: <br />OPERATING ROOM 60 PSF LL 20 PSF SDL <br />LABORATORY 60 PSF LL 20 PSF SDL <br />CORRIDOR 80 PSF LL 12 PSF SDL <br />SUBMITTALS: SHOP DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT PRIOR TO FABRICATION <br />AND CONSTRUCTION REGARDING ALL STRUCTURAL ITEMS INCLUDING THE FOLLOWING: <br />FASTENERS <br />IF THE SHOP DRAWINGS DIFFER FROM OR ADD TO THE DESIGN OF THE STRUCTURAL DRAWINGS, <br />THEY SHALL BEAR THE SEAL AND SIGNATURE OF A STRUCTURAL ENGINEER REGISTERED IN THE <br />STATE OF FLORIDA. ANY CHANGES TO THE STRUCTURAL DRAWINGS SHALL BE SUBMITTED TO THE <br />ARCHITECT AND ARE SUBJECT TO THE REVIEW AND ACCEPTANCE OF THE STRUCTURAL ENGINEER. <br />DESIGN DRAWINGS, SHOP DRAWINGS AND CALCULATIONS FOR THE DESIGN AND FABRICATION OF <br />ITEMS THAT ARE DESIGNED BY OTHERS, INCLUDING: <br />UNISTRUT FRAMING <br />SHALL BEAR THE SEAL AND SIGNATURE OF A STRUCTURAL ENGINEER REGISTERED IN THE STATE <br />OF FLORIDA, AND SHALL BE SUBMITTED TO THE ARCHITECT PRIOR TO FABRICATION. <br />CALCULATIONS SHALL BE INCLUDED FOR ALL CONNECTIONS TO THE STRUCTURE, CONSIDERED <br />LOCALIZED EFFECTS ON THE STRUCTURAL ELEMENTS INDUCED BY THE CONNECTION LOADS. <br />DESIGN SHALL BE BASED ON THE REQUIREMENTS OF THE 2004 FBC. <br />STRUCTURAL ANCHORING: WEDGE STYLE ANCHORS SHALL BE USED IN SOLID CONCRETE <br />APPLICATIONS. WEDGE ANCHORS ARE A 1 (ONE) PIECE STUD ANCHOR WITH STEEL CLIP <br />(EXPANDING RING) CONFORMING TO FEDERAL SPECIFICATION FF-S-325, GROUP 11, TYPE 4, CLASS I. <br />ANCHORS SHALL BE TESTED TO ASTM E488 AND ICBO ACOI. ICBO AND/OR SBCCI CODE <br />COMPLIANCE ARE REQUIRED IN APPROPRIATE AREAS. METRO-DADE COMPLIANCE AND/OR <br />FLORIDA BUILDING CODE COMPLIANCE ARE REQUIRED IN FLORIDA. ACCEPTED ANCHORS ARE ITW <br />RED -HEAD TRUBOLTS, HILTI KWIK-BOLT 11, OR ENGINEER APPROVED SUBSTITUTION. <br />CARBON STEEL ANCHORS SHALL BE ZINC PLATED IN ACCORDANCE WITH ASTM B633 OR <br />HOT -DIPPED GALVANIZED ACCORDING TO ASTM A153. PERMANENTLY EXPOSED ANCHORS SHALL <br />BE HOT -DIPPED GALVANIZED OR STAINLESS STEEL. USE 316 STAINLESS STEEL FOR SERVICING <br />EQUIPMENT AND FOR ALUMINUM AND FIBERGLASS STRUCTURES AND ASSEMBLIES. <br />ANCHOR BOLTS SHALL CONFORM TO ASTM A307 OR A36. <br />W <br />ti <br />CHEMICAL ADHESIVE ANCHORING AND DOWELING TO CONCRETE: ADHESIVE ANCHORS (EPDXY <br />STYLE) SHALL BE USED IN SOLID CONCRETE OR GROUT -FILLED APPLICATIONS FOR STRUCTURAL <br />ANCHORING AND REBAR DOWELING. ANCHORS SHALL BE TESTED TO ASTM E488 AND ICBO AC58. <br />ICBO AND/OR FLORIDA BUILDING CODE COMPLIANCE IS REQUIRED IN APPROPRIATE AREAS. <br />METRO- DADE COMPLIANCE AND/OR FLORIDA BUILDING CODE COMPLIANCE ARE REQUIRED IN <br />FLORIDA. ACCEPTED PRODUCTS ARE ITW RED -HEAD GRANITE 5, ACRYLIC 7, ALLIED A1000+, <br />BRINKER BROWN 20/20 OR ENGINEER APPROVED SUBSTITUTION. <br />ADHESIVE SHALL BE MOISTURE INSENSITIVE (ALLOWING INSTALLATIONS IN DAMP OR <br />WATER -FILLED HOLES). ADHESIVE SHALL HAVE A FULL -CURE LOAD OF 2 HOURS OR LESS AT 70"F <br />FOR SAFETY ISSUES. <br />THREADED STUDS SHALL CONFORM TO ASTM A36 (STANDARD CARBON STEEL), UNLESS NOTED <br />OTHERWISE. PERMANENTLY EXPOSED STUDS SHALL BE STAINLESS STEEL. NUTS AND WASHERS <br />SHALL CONFORM TO THE SAME SPECIFICATIONS AS THE SUPPLIED ANCHOR RODS. <br />INSTALLATION SHALL BE IN CONFORMANCE WITH MANUFACTURER'S PRINTED LITERATURE. <br />INSTALLATION SHALL ALSO INCLUDE BRUSHING AND CLEANING OF DRILLED HOLES WITH <br />COMPRESSED AIR AS INSTRUCTED. INSTALLERS SHALL BE TRAINED BY THE MANUFACTURER'S <br />REPRESENTATIVE. EMBEDMENTS SHALL BE INDICATED ON THE STRUCTURAL DRAWINGS. <br />STRUCTURAL STEEL: STRUCTURAL STEEL SHALL CONFORM TO ASTMA992, GRADE 50. PLATES <br />AND ANGLES SHALL CONFORM TO ASTM A36. TUBES SHALL CONFORM TO ASTM A500, GRADE B (Fy <br />- 46ksi). PIPES SHALL CONFORM TO ASTM A53, GRADE B. DESIGN, FABRICATION, AND ERECTION <br />SHALL BE IN ACCORDANCE WITH THE "AISC SPECIFICATION FOR THE DESIGN, FABRICATION, AND <br />ERECTION OF STRUCTURAL STEEL BUILDINGS". BOLTS SHALL CONFORM TO ASTM SPECIFICATION <br />FOR A325 OR A490, HIGH STRENGTH BOLTS. WELDING SHALL CONFORM TO THE AWS CODES FOR <br />ARC AND GAS WELDING IN BUILDING CONSTRUCTION. WELDS SHALL BE MADE USING E70XX <br />ELECTRODES AND SHALL BE 3/16" MINIMUM UNLESS NOTED OTHERWISE. WELDING SHALL BE BY <br />AWS CERTIFIED WELDERS. PREQUALIFIED WELDING PROCEDURES ARE TO BE USED, UNLESS AWS <br />QUALIFICATION IS SUBMITTED TO THE ENGINEER PRIOR TO FABRICATION. STEEL TO RECEIVE ONE <br />SHOP COAT AND ONE FIELD TOUCH-UP COAT OF APPROVED PAINT, EXCEPT WHERE GALVANIZING <br />IS INDICATED ON THE DRAWINGS. <br />ALL BOLTED CONNECTIONS SHALL CONSIST OF A MINIMUM 3/4 INCH DIAMETER ASTM A325 HIGH <br />STRENGTH BOLTS. BEAM CONNECTIONS SHALL BE DESIGNED BY THE FABRICATOR FOR THE <br />REACTIONS SHOWN ON THE DRAWINGS. IF NOT SHOWN, THE FABRICATOR SHALL DESIGN THE <br />BEAM CONNECTIONS TO SUPPORT AN END REACTION OF 1/2 THE ALLOWABLE UNIFORM LOAD <br />CAPACITY WITH A MINIMUM OF TWO BOLTS. <br />ANCHOR BOLTS SHALL CONFORM TO ASTM A307 OR A36. <br />UNISTRUT FRAMING: PROVIDE AND INSTALL A COMPLETE ENGINEERED UNISTUT SYSTEM AS <br />INDICATED ON PLANS AND SECTIONS. SYSTEM SHALL BE TRUE, PLUMB, AND LEVEL WITH NO MORE <br />THAN 11720 DEFLECTION OF ANY SPAN IN EITHER DIRECTION BASED ON MAXIMUM LOADING <br />CONDITIONS. ALL MATERIALS SHALL BE PROTECTED FROM CORROSION WITH A FACTORY APPLIED <br />FINISH. <br />SUBMIT SHOP DRAWINGS SIGNED AND SEALED BY FLORIDA PROFESSIONAL ENGINEER DETAILING <br />THE COMPLETE SYSTEM INCLUDING PLANS, SECTIONS, AND DETAILS INCLUDING ALL <br />MANUFACTURED PARTS, CATALOG NUMBERS, FASTENERS, AND HARDWARE. <br />INSTALLER SHALL ASSURE ALL FRAMING CAN BE INSTALLED ACCORDING TO THE SHOP DRAWINGS. <br />ANY INTERFERENCE SHALL BE REPORTED TO THE ARCHITECT. <br />STRUCTURAL DRAWING LIST <br />SHEET NO. <br />TITLE <br />SCALE <br />S-1 <br />STRUCTURAL NOTES <br />NONE <br />S-2 <br />EXISTING PARTIAL SECOND FLOOR PLAN <br />Y4" = V-W <br />S-3 <br />EXISTING PARTIAL THIRD FLOOR PLAN <br />Y4" = 1'-W <br />I r, C**. 600 r <br />CONSULTING ENGINEERS <br />7680 Universal Boulevard, Suite 580 <br />Orlando, Florida 32819 <br />407.363.1201 " FAX 407.363.1204 <br />E-MAIL: info@tkwonline.com <br />Engineering Certification # 5762 <br />Survey LB # 734 <br />gI,JBNIITTED PLAN(S) <br />MARS AL'S <br />N RI <br />BY ZEPHYRHILL <br />Reviewer. <br />VA -LAM 211� T6 � 14L <br />BUILDING SHALL COSIPLY WITh K 12 19- wo• lot 0 4 <br />ALL APPLICABLE BUILDING, <br />ELECTRICAL, PLUMBING AND <br />,4ECkUNNI C e�' CODES <br />am 40-m&I <br />hojCd No. 0109.00 <br />S-1 <br />W <br />ti <br />Q <br />©n013WM AnM%c%1w. <br />