Laserfiche WebLink
111-5" 21'-10" <br />EXISTING B40 (36"x17") <br />PARTIAL EXISTING SECOND FLOOR PLAN �7., <br />SCALE: Yam =1'-0" <br />m r +&Ar <br />CONSULTING ENGINEERS <br />7680 Universal Boulevard, Suite 580 <br />Orlando, Florida 32819 <br />407.363.1201 • FAX 407.363.1204 <br />E-MAIL: info@tkwonline.com <br />Engineering Certification # 5762 <br />Survey LB # 734 <br />PLAN NOTES: <br />EXISTING FLOOR IS CONVENTIONALLY REINFORCED CONCRETE <br />WITH 3" THICK SLAB, 6"x14" JOIST AT T-Ow O.C. TYP. (14"x6"x30" PANS), <br />AND BEAMS. <br />NEW EQUIPMENT BY PHILLIPS. INSTALLATION AND LOCATION AS <br />El INDICATED PER THEIR DRAWINGS AND SPECIFICATIONS. <br />AD7 UNIVERSAL FLOOR PLATE BY PHILLIPS FOR MSA. ANCHOR TO <br />EXISTING CONCRETE BEAM B31 WITH 4-HILTI Y4"0 x 8 Y4"THREADED <br />HIS INSERTS WITH %4 fd HAS-E THREADED RODS, NUTS AND <br />WASHERS AND HIT HY-150 EPDXY ADHESIVE. <br />NON-STRUCTURAL PARTITION WALLS FOR ROOMS SUPPORTED BY <br />F±1 SECOND FLOOR. SEE ARCH. DWGS FOR LOCATION. <br />BUILL)ING SfLi.LL ';Olv_iPLY W17rh <br />ALL APPLICABLE BUILD?NG, <br />ELECTRICAL, PLUMBING AND <br />SUBMITTED PLANS) HAVE BEEN REv ►e:'"' G> <br />BY ZEPHYRHII-LS FIRE'RSHAL' S OFFit= <br />Date: <br />Reviewer: <br />U�ftAUteZ.N��rt � PE. <br />PtojedNo. 08009.00 <br />S-2 <br />