Laserfiche WebLink
DEMOLITION KEY NOTES: <br />O1 EXISTING RISER UP TO PATIENT ROOM FAN <br />COIL UNITS. CONTRACTOR SHALL COORDINATE <br />SHUTDOWN OF RISER WITH HOSPITAL TO <br />MINIMIZE IMPACT ON PATIENT CARE. <br />O DEMO AND REWORK CHILLED WATER RETURN <br />AND HOT WATER RETURN PIPING. COORDINATE <br />ALL EQUIPMENT SHUTDOWN WITH HOSPITAL. <br />9 <br />I <br />:ORR(DOR <br />ASSAGE <br />i <br />MECHANICAL PARTIAL <br />SECOND FLOOR PIPING PLAN - DEMOLTION <br />mil 1 0 <br />0' 2' 4' 8' 16, 2 4' <br />u <br />Flo <br />NEW CONSTRUCTION KEY NOTES: <br />1D INSTALL NEW 1.5 TON CRAC UNIT IN NEW CATH LAB <br />EQUIPMENT ROOM WITH CONDENSATE PUMP. <br />O CONNECT TO EXISTING HOT WATER PIPING. <br />O CONNECT TO EXISTING CHILLED WATER PIPING. <br />ROUTE CONDENSATE PIPING TO EXISTING RAIN <br />WATER LEADER. _ <br />O ALL NEW PIPING SHALL BE INSTALLED TIGHT <br />TO STRUCTURE. <br />© CONNECT NEW PIPING TO EXISTING RISERS. <br />O COORDINATE PIPING ROUTING WITH CATH LAB EQUIPMENT <br />UNISTRUT REQUIREMENTS. <br />MECHANICAL PARTIAL <br />SECOND FLOOR PIPING PLAN - NEW CONSTRUCTION <br />i111i 11 i <br />0' 2' 4' 8' 16, 2 4' <br />DEMOLITION LEGEND <br />SYMBOL <br />DESCRIPTION <br />EXISTING TO REMAIN <br />EXISTING TO BE REMOVED <br />DEMO TO THIS POINT <br />NEW CONSTRUCTION LEGEND <br />SYMBOL <br />DESCRIPTION <br />EXISTING TO REMAIN <br />NEW CONSTRUCTION <br />CONNECT TO EXIST. AT THIS POINT <br />FIRE WALL LE <br />SYMBOL <br />DESCRIPTION <br />viewer. <br />- — — — — <br />SMOKE BARRIER <br />— - — - — - <br />I HR. RATED FIRE PARTITION <br />— — • — — <br />1 HR. RATED FIRE/SMOKE PARTITION <br />- • - — - - — <br />2 HR. RATED FIRE PARTITION <br />— — - - — - <br />2 HR. RATED FIRE/SMOKE PARTITION <br />BUILOING SIIrtLi COMPLY WiTh <br />ALL APPLICABLT BUILDING, <br />ELECIMCAL, PLUMBING AND <br />am <br />y <br />ti <br />V <br />t <br />9 <br />Ls <br />O <br />SCE <br />N <br />0 <br />Prnject No. 08009.00 <br />M4,61 <br />02008 BH/PK Architects, Inc. <br />