Laserfiche WebLink
sdo , mill <br />- - - ------ ----- ............ <br />STG EQUIPT <br />4URESRY <br />-- CORRIDOR <br />! !E <br />r� <br />CATH PREP <br />CLEAN HOLD. <br />DEMOLITION LEGEND <br />SYMBOL <br />DESCRIPTION <br />EXISTING TO REMAIN <br />EXISTING TO BE REMOVED <br />DEMO TO THIS POINT <br />Jim =im ...�.� <br />!.. <br />-_- - - , 1 - - JELC-1� - - - - <br />CORRIDOR E , ELC-2 1 EC213=41 <br />rom <br />C2B-5TER LC-12 ELC <br />LA <br />002 , ELC - - -- <br />+' EC213-3 �' ELC-6 ' <br />1i ELC-5 ` <br />, + <br />L2B-40 <br />ELC-10 <br />+ i <br />' OFFICE , ! <br />' 004---� <br />c ELC-11 <br />F___-- - - -- <br />LIFE SAFETY <br />CIRCUIT (120V) re _u OFFICE <br />i 010 <br />1 ---_---+--I! I -- - - - --J-L-- <br />- -�--; <br />b <br />AD.O. CONTROL <br />OOM SRUB ROOM <br />L2B ' <br />I IC <br />CORRIDO 2LC6-14 <br />Ff <br />EQUIPMENT I <br />SECOND FLOOR POWER PLAN - DEMOLITION <br />1111111 I <br />0' 2' 4' 8' 16' 24' <br />O KEY NOTES: <br />1. CONTRACTOR SHALL RELOCATE EXISTING AUTOMATIC DOOR OPENER. REFER TO NEW CONSTRUCITON <br />PLAN FOR NEW LOCATION. <br />LIMIT OF DEMOLITION <br />DISCONNECT AND REMOVE ALL EXISTING ELECTRICAL FIXTURES, DEVICES, PANELBOARDS AND <br />CONNECTIONS TO EXISTING ELECTRICAL EQUIPMENT IN THIS AREA UNLESS OTHERWISE NOTED <br />HERE OR ON OTHER DRAWINGS. REFER TO ELECTRICAL SPECIFICATION SECTION 16010 FOR OTHER <br />REQUIREMENTS. ALL EXISTING RACEWAYS PASSING THROUGH THIS AREA FEEDING OTHER AREAS <br />SHALL REMAIN INTACT AND OPERATIONAL. ALL OTHER RACEWAYS SHALL BE REMOVED. <br />TEMPORARILY REMOVE EXIT SIGNAGE AND RE -DIRECT OTHER EXIT SIGNS PER THE ARCHITECTURAL <br />LIFE SAFETY PLAN FOR APPROPRIATE EGRESS DURING CONSTRUCTION PERIOD. REPLACE EXIT <br />SIGNS PER THE FINAL ARCHITECTURAL LIFE SAFETY PLAN PRIOR TO FINAL INSPECTION. <br />IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO REMOVE AND REINSTALL ANY <br />LIGHT FIXTURES OR CEILING MOUNTED DEVICES THAT NEED TO BE TEMPORARILY REMOVED DUE <br />TO THE RENOVATION OF ANY MECHANICAL OR ELECTRICAL SYSTEMS. THE CONTRACTOR SHALL <br />VERIFY ALL AREAS OF POTENTIAL RE -WORK PRIOR TO BID. <br />CONTRACTOR SHALL MAINTAIN EXISTING FIRE ALARM SYSTEM WITHIN AREA OF DEMOLITION <br />THROUGHOUT CONSTRUCTION PERIOD. PROVIDE SMOKE DETECTOR COVERS DURING WORK <br />HOURS AND REMOVE SMOKE DETECTOR COVERS OUTSIDE OF WORK HOURS. <br />THE ELECTRICAL CONTRACTOR SHALL PROVIDE POWER TO THE NEGATIVE AIR MACHINE UTILIZED <br />DURING THE DEMOLITION AND NEW CONSTRUCTION PHASES FROM THE EQUIPMENT SYSTEM OF <br />THE ESSENTIAL SYSTEM. <br />ELEV. <br />LOBBY <br />■ <br />4URESRY <br />NEW CONSTRUCTION LEGEND <br />SYMBOL <br />DESCRIPTION <br />EXISTING TO REMAIN <br />NEW CONSTRUCTION <br />i-� <br />CONNECT TO EXIST. AT THIS POINT <br />ELEV. <br />LOBBY <br />SECOND FLOOR POWER PLAN - NEW CONSTRUCTION <br />1'1'111 ! <br />0' 2' 4' 8' 16, 24' <br />CATH LAB *3 GENERAL NOTES: <br />I. REFER TO PHILIPS HEALTHCARE DRAWINGS N-SOUO80446, DATED 6/20/08. <br />FURNISH AND INSTALL WIRING, CONDUIT, RACEWAYS, JUNCTION BOXES, CIRCUIT <br />BREAKERS, RELAYS, SHUNT -TRIP PUSH BUTTONS AND ALL OTHER ELECTRICAL <br />ITEMS NOT PROVIDED BY PHILIPS. PULL ALL CABLES FURNISHED BY PHILIPS <br />AND MAKE ALL CONNECTIONS AS DIRECTED BY PHILIPS. <br />2. CONDUCTORS SHALL BE COPPER, AWG STRANDED, TYPE THWN OR THHN, <br />FLEXIBLE, THERMO-PLASTIC COVERED, AND COLOR -CODED. CONDUCTORS <br />SHALL BE CUT TEN FOOT LONG AT OUTLET BOXES, DUCT TERMINATION <br />POINTS OR STUBBED CONDUIT ENDS, UNLESS OTHERWISE SPECIFIED. ALL <br />CONDUCTORS, POWER, SIGNAL, AND GROUND MUST BE RUN IN CONDUIT <br />OR DUCT SYSTEM (SEPARATED BY BARRIERS). CONTRACTOR SHALL RING <br />OUT AND TAG ALL WIRES AT BOTH ENDS. WIRE RUNS MUST BE CONTINUOUS <br />AND FREE FROM SPLICES. <br />3. COORDINATE WITH PHILIPS HEALTHCARE DRAWINGS AND PROVIDE ELECTRICAL <br />DUCT WITH DIVIDERS OR INDIVIDUAL CONDUIT TO PROVIDE SEPARATION FOR THE <br />FOLLOWING CABLE TYPES: <br />(1) 24 VOLT <br />(2) 300 VOLT AND LESS <br />(3) 301-600 VOLTS <br />(4) HIGH TENSION X-RAY CABLES <br />(5) VIDEO CABLES <br />ALL CABLES SHALL BE SEPARATED FOR THEIR ENTIRE RUN. <br />4. EXACT LOCATIONS OF ALL WIREWAYS, CONDUIT RUNS, AND JUNCTION BOXES <br />SHALL BE IN ACCORDANCE AND COORDINATED WITH THE PHILIPS MEDICAL <br />SYSTEMS DRAWINGS. <br />5. FOR CONDUIT SIZES REQUIRED BETWEEN EQUIPMENT REFER TO PHILIPS MEDICAL <br />SYSTEMS DRAWINGS. <br />6. REFER TO PHILIPS HEALTHCARE DRAWINGS FOR THE EXACT LOCATION AND <br />MOUNTING HEIGHTS OF ALL NEW ELECTRICAL DEVICES TO BE INSTALLED. <br />7. EACH CONDUIT SHALL TERMINATE IN A PLASTIC BUSHING. LEAVE 10' WIRE PIGTAIL <br />AT ALL TERMINATION POINTS. <br />8. PHILIPS HEALTHCARE REPRESENTATIVE SHALL PERFORM A LEAKAGE CURRENT <br />TEST IN ACCORDANCE WITH NFPA 99 (2002) CHAPTER 8.4.1.3.5 ON ALL PHILIPS <br />EQUIPMENT TO BE INSTALLED UNDER THE PROJECT SCOPE. UPON COMPLETION OF <br />THE LEAKAGE CURRENT TEST, THE PHILIPS REPRESENTATIVE SHALL SUBMIT THE <br />RESULTS TO THE ELECTRICAL ENGINEER OF RECORD FOR REVIEW AND APPROVAL. <br />THE FINAL OFFICIAL RESULTS OF THE TEST SHALL BE PROVIDED TO THE OWNER'S <br />REPRESENTATIVE, GENERAL CONTRACTOR, AND ELECTRICAL ENGINEER OF RECORD <br />PRIOR TO THE FINAL INSPECTION. <br />9. ELECTRICAL CONTRACTOR SHALL PROVIDE CODE COMPLIANT PENETRATIONS FOR ALL <br />NEW CONDUITS ENTERING/EXITING FIRE RATED WALLS. ALL EXISTING NON -COMPLIANT <br />ELECTRICAL PENETRATIONS IN THE PROJECT SCOPE SHALL BE THE RESPONSIBILITY <br />OF THE ELECTRICAL CONTRACTOR TO CORRECT. <br />a <br />ite <br />52�5� N <br />oedn�ran'n"' <br />kk� � <br />THE ELECTRICAL CONTRACTOR SHALL PERFORM AND PROVIDE AT FINAL <br />INSPECTION AN EQUIPOTENTIAL GROUNDING TEST IN ALL PATIENT <br />ROOMS AS FOLLOWS: <br />EQUIPOTENTIAL GROUNDING TEST: <br />THE ELECTRICAL CONTRACTOR SHALL TEST THE EFFECTIVENESS OF <br />THE GROUNDING SYSTEM BY VOLTAGE AND IMPEDANCE MEASUREMENTS. <br />MAKE THE MEASUREMENTS AS REQUIRED BY NFPA 99, SECTION 4.3.3. <br />RECORD AND TABULATE THE RESULTS MAKING THEM AVAILABLE TO THE <br />AUTHORITIES HAVING JURISDICTION AT THE TIME OF FINAL INSPECTION. <br />TESTING SHALL INCLUDE: <br />1. CORRECTING ANY WIRING FOUND DEFICIENT. <br />2. PROVIDE *10 AWG BOND WIRING WHERE REQUIRED (IN ACCORDANCE <br />WITH MANUFACTURER) TO SATISFY GROUNDING REQUIREMENTS. <br />3. TESTS SHALL BE PERFORMED AND CERTIFIED BY A MASTER <br />ELECTRICIAN LICENSED IN THE JURISDICTION. <br />CATH LAB *3 GROUNDING NOTES: <br />1. GROUNDING SHALL COMPLY WITH NFPA 70 (2005) ARTICLE 517 AND NFPA 99 (2002). <br />ALL EQUIPMENT SHALL HAVE REDUNDANT A GROUND PATH. <br />2. ALL NIPPLES REQUIRE GROUND STUDS AND ALL DUCT WORK REQUIRES GROUND JUMPERS <br />AT ALL JOINTS. <br />3. ALL PHILIPS CABINETS MUST BE CONNECTED TO THE DUCT OR JUNCTION BOXES WITH <br />DIRECT BONDING OR JUMPER WIRES. <br />4. OVERHEAD TUBE OR TV MONITORS MUST HAVE A GROUND WIREF ROM THE DUCT OR <br />JUNCTION BOX TO THE TV MONITOR OR X-RAY TUBE UNIT. <br />O KEY NOTES: <br />1. MEDGAS FLOOR PEDESTAL. REFER TO 'FLOOR MOUNTED SERVICE PEDESTAL' DETAIL ON SHEET <br />E6.1 FOR ELECTRICAL INSTALLATION REQUIREMENTS. TO BE PROVIDED BY DIVISION 15. REFER <br />TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION. <br />2. NEW POWER PANEL AS REQUIRED BY PHILIPS HEALTHCARE DRAWING ED4. REFER TO PARTIAL <br />ELECTRICAL RISER DIAGRAM ON SHEET E5.1 FOR PANEL TYPE AND ORDERING II4PbM9MR.AN(s) HAVE BEEN RI <br />BY 3. FURNISH AND INSTALL NEW SHUNT TRIP 'EMERGENCY OFF' PUSHBUTTON. MOUN& BOVH E� MU FIRE SHAL's <br />LIGHT SWITCHES. REFER TO PHILIPS DRAWING ED4 FOR CONNECTION DETAILS. Reviewer. <br />4. CONNECTION TO EXISTING 480/277V CRITICAL BRANCH PANEL ECDIAG. REFER TO PARTIAL <br />ELECTRICAL RISER DIAGRAM ON SHEET E5.1 FOR FEEDER SIZE. <br />5. POWER CONNECTION FOR PYXIS. VERIFY APPROPRIATE MOUNTING HEIGHT OF RECEPTACLE <br />WITH OWNER. <br />6. MOUNT INDICATED RECEPTACLES ABOVE COUNTER. <br />7. CRAC-1 SHALL BE INSTALLED ABOVE CEILING. REFER TO MECHANICAL DRAWINGS FOR EXACT <br />LOCATION. <br />8. NEW LOCATION OF EXISTING AUTOMATIC DOOR OPENER. EXTEND EXISTING LIFE SAFETY CIRCUIT. <br />>I <br />9. FURNISH AND INSTALL NEW FUSED DISCONNECT. PROVIDE (1) CLASS RK5-TIME DELAY 15A FUSE <br />FOR PHASE CONDUCTOR ONLY. DO NOT FUSE NEUTRAL. FIELD VERIFY APPROPRIATE LOCATION <br />TO MOUNT DISCONNECT IN COMPUTER ROOM 002. <br />BUILOING SHr.LL PL� WI`i�: <br />ALL APPLICABLE 3UILDINI G, <br />ELEC t RICAL, PLUMBING AND <br />'� (,-1 1 ,7 CAi (00 S <br />a <br />°0 <br />a <br />A <br />� <br />Project No. 08009.00 <br />E3,91 <br />©8008 BH/PS Architects, Inc. <br />